| 1 | Dismantling and removing the weathering course and preseed tiles including all labour charges etc completed |
| 2 | Dismantling and removing the Reinforced cement concrete including all labour charges etc completed |
| 3 | Dismantling and removing the Brick work including all labour charges etc completed |
| 4 | Removing andDamaged Doors and Windows including removal of frames, hinges and fastenings including labour charges etc completed. |
| 5 | Dismantling the Fully Damaged Floor finish including all labour charges etc completd. |
| 6 | Dismantling the Fully Damaged Plain cement concrete including all labour charges etc completd. |
| 7 | Conveyance of dismantling debris and clear away from the site including loading, unloading and all labour charges etc, complete |
| 8 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil,wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may bedirectedexceptinhardrockrequiring blastinginclusive of shoring shuttering, ,and baling out water and cleaning and levelling the site etc.,complete 10 m3 |
| 9 | Supplying and filling in foundation andbasement with filling M-sandin layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification. |
| 10 | Supplying and filling in foundation andbasement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 11 | Plain Cement Concrete 1:4:8 (one cement fourfine aggregates and Eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying water carrying with all leads of good water compacting and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 12 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38Column |
| 13 | Plinth Beam Grade Beam alround |
| 14 | Slab and Beam Lintel |
| 15 | Providing and laying in position, standardised concrete Mix M-20 Grade in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 Cum.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cum.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 Cum) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). up to basement |
| 16 | Above ground floor |
| 17 | Supplying and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors. |
| 18 | Fly ash in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using fly ash bricks of size 230 x 110 x 70mmincluding finishing, curing, etc., complete complying with standard specification up to basement |
| 19 | Above basement |
| 20 | Brick partition walls using best quality using CountryBricks of size 8-3/4\" x 4-1/4\" X2-3/4\" in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 21 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers |
| 22 | Plastering with cement mortar (1:5),12 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 23 | Painting two coats for Interior surface with approved Interior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. |
| 24 | Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coatincluding the cost all materials etc.,complete, in all floors. |
| 25 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 26 | R.C.C.Jolly by a new of followingsize in M20 Concrete using 20mm gauge hard broken granite stone jelly and river sand excluding cost of reinforcement but includingcharges,fabrication chargescuring neat finishing and labour charges for fixing the jolly in position with standard spefication |
| 27 | Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelain low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting |
| 28 | Providing granolithic floor finish of 25mm thickness with plain cement concrete 1:2:4 (One Cement, Two crushed sand (M-Sand) and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) |
| 29 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement |
| 30 | Dadooing walls withGlazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 31 | Paving the Top of roof with Solar refelective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by the Executive Engineer before use on works) |
| 32 | Supplying and fixing fine polished cuddapah slab of following thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct. |
| 33 | Wiring with 2x1.5 sq.mm. PVC insulated SCunsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5AFT switch and making good of the concealed portion with suitable colour for PVC concealed light/fan point (5points per coil) (SD-25) |
| 34 | Wiring with 2x1.5sq.mm PVCinsulated SC unsheathedFRL Scopper conductorof1100VgradeinsuitablePVCrigidpipeconcealedinwallandceilingwithPVCaccessoriesinflushwithwallwith150mmx100mmx113mmTWswitchboxwith3mmthickhylemsheetcoverfor5A3pinnoninterlockingwallsocketwith5Aflushtypeswitchwithcontinuousearthwireconnectionof1.5sq.mmcopperwireandmakinggoodoftheconcealedportionwithsuitablecolour for concealed PVC plug point SD-38) |
| 35 | Supply and fixing of 1200mm (48\")Ac ceiling fan complete with stepped electronic 300Wregulatorwith300mmdownrod on the existing clamp SD-110 |
| 36 | Supply and fixing of 20 w 4\"LED light fitting including all labour charges etc complted |
| 37 | Supply and run of 2of1.5sq.mm. PVC insulated Scunsheathed FRLS copper conductorof1100Vgradeon7/20GIbearer wire for service connection mains sd -64 |
| 38 | Supply and run of 2x1.5sq.mm.PVC insulated Scunsheathed FRLS copperconductorof1100Vgradein25mmdiaGI pipe (Class \"B\") suitably bent at both ends with necessary angle iron upright and end supports for mains sd -69 |
| 39 | Supply and delivery and fixing of HDPE tank (1000 liter)as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., |
| 40 | Supply and fixing of PVC Pipe and specials including cost and conveyance of standard specification 32mm PVC pipe |
| 41 | 32mm PVC Elbow |
| 42 | 20mm pvc Tap |
| 43 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 44 | Providing rain water harvesting using 6 No.of RCC well rings of 90cm inner dia (clear) with 5cm wall thickness made out of cement concrete 1:2:4 using 20mm hard broken jelly to a height of 30cm each supplying and fabricating 16 No. of 6mm dia MS rod vertically and 3 No. of 6mm dia MS rod circumferentially tied together with 18 guage binding wire for well rings including necessary earth work excavation 1m dia toa depth of 1m, supplying and filling 40mm HBG inside the erected well ring to a depth of 90cm, and top covered with RCC circular perforated cover slab of 1m dia and 5cm thick which inclusive of cost and fabrication of 6mm M.S reinforcement at 15 cm spacings on both directions and one 6mm M.S rod ties at the edge of the slab circumferentially including cost of moulding, curing, finishing and well placing in position and disposing off excavated earth with all initial leads and lifts in places as shown by the Departmental officers etc., complete in all respects. |
| 45 | Supplying and fixing in position best quality cuddapah sink of following sizes including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets.[The sink and specials should be got approved by the Executive Engineer before use on works] |
| 46 | Goods and Service Tax @ 18% |