}

Jodhpur Façade Lighting Work Of Samrat Ashok Udhyan, - Electric Work, Jodhpur-Rajasthan

Jodhpur Development Authority has published Jodhpur Façade Lighting Work Of Samrat Ashok Udhyan, - Electric Work. Submission Date for this Tender is 19-05-2025. Decoration Work Tenders in Jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49110815
Jodhpur Façade Lighting Work Of Samrat Ashok Udhyan, - Electric Work
Open Tender
Indian
Rajasthan
Jodhpur
19-05-2025

Tender Documents

Tender Details

Jodhpur Façade Lighting Work Of Samrat Ashok Udhyan, - Electric Work; 1 1.4.2 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 mm 1200 R. Mtr. 56.00 67200.00 2 4.1.6 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 2 x 2.5 sq.mm 1200 Mtr. 61.00 73200.00 3 4.1.12 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 3 x 4.00 sq.mm 700 Mtr. 137.00 95900.00 4 11.2.5. 3 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 25.0 Sq. mm 3.5 core 250 Mtr. 285.00 71250.00 5 5.2.5 P & F in position frame made out of M.S. angle (riveted or welded) finished with two coats of red oxide and two coats enamel paint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 50mm x 50mm x 6mm 10 Mtr. 551.00 5510.00 6 5.5.3 P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 6.4 mm thick 4 Sq.m m 1291.00 5164.00 JODHPUR DEVELOPMENT AUTHORITY, JODHPUR G-SCHEDULE Name of work :- Façade lighting work of Samrat Ashok Udhyan, Jodhpur. As per Electric BSR 2022 7 8.1 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- (a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 8 (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. (f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 12 Sq. Mtr. 5975.00 71700.00 9 8.2.1 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade 4 Kg. 542.00 2168.00 10 8.14.2. 5 Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 4 pole Power contactors with following AC 1 Rating 63 Amp 1 Each 4045.00 4045.00 11 8.8.1 Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . a) Red/yellow/Green colour 3 Each 170.00 510.00 12 8.8.2 b) Blue / white Colour 3 Each 260.00 780.00 13 8.20.3 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2- 7 etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . One day & week reserve (digital type ) 1 Each 4100.00 4100.00 14 9.3.1.1 SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 3 pole MCCB 8 Each 1698.00 13584.00 15 9.3.3.1 4 pole MCCB With Thermal Magnetic release up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 1.00 Each 2215.00 2215.00 16 6.1.1.2 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898- 1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 48.00 Each 187.00 8976.00 17 8.3.3. Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Three phase Ammeter with Inbuilt Selector Switch 1.00 Each 1689.00 1689.00 18 8.3.4 Three phase Voltmeter with Inbuilt Selector Switch 1 Each 1689.00 1689.00 19 8.5.2 Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . Voltage Between Phases & Individual Phases to Neutral with OFF ( 7 Position ) 1 Each 692.00 692.00 20 8.6 Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi- metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 1 Each 384.00 384.00 21 14.3 Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 2.00 Set 15144.00 30288.00 22 14.5.1 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 20mm x 3mm copper strip 20.00 Mtr. 781.00 15620.00 476664.00 S.No BSR Code Item Qty. Unit Rate Amount (Rs.) Total (G SCHEDULE) H-Schedule 1 Non BSR SITC of exterior rated LED RGBW flood light luminaires with dedicated optics and 4 Colour with each single LED for architectural lighting with Glue less technology. Luminaire has a choice of architectural flood lighting optics with beam angle of 20-60°, Wattage not exceeding 120 Watt, UV and temperature-resistant lens system. Symmetric distribution, Luminaire luminous flux range 3500-4200Lm . Lumens will be measured in White colour with all 4 channels in ON conditions, with inbuilt decoder .Lumens will be measured in White colour with all 4 channels in ON conditions and IP68 connector. Luminaire Controlled through Wi Fi / DMX/Ethernet controller, Controller can achieve 16.7M colors. Rated input supply of AC 220V constant voltage. Luminaire without control unit. Light color RGBW.Optics to be selected as per the application requirement Mean rated service life L70 (tq 25 °C) > 50,000 burning hrs. Luminaire body of Die-Cast aluminum alloy housing with heat resistant tempered glass cover & Double Powder Coating, outdoor grade, anti-UV glassingress protection rating > IP66 and impact rating 07. The LED system with separate control gear unit is suitable for operation on direct voltage supply grid. Driver Efficiency: >85%, Operating Temperature: -10°C to +50°C, Operating Humidity : 10%-90% The luminanes should have options for various bearm angles i.e. from 20° to 60° actual will depends on the approved design/as per site requirement. Housing to have adjustable base bracket for angle adjustment so that light direction can be adjusted to illumnatedesired structural elements. The LED luminaires and external driver should be CE/BIS certified. The proposed fixture must have passed LM-79 & LM-80 report from NABL laboratory. The must be submitted prior to the supply of material.The work includes all accessories, connectors, wire etc. complete in all respect. (with Three years warranty)The make of LEDCREE/OSRAM/NICHIA/SEOUL MAKE of Lumnaires Philips /Surya /Wipro/ Crompton 16 Each 2 Non BSR SITC of exterior rated LED RGBW flood light luminaires with dedicated optics and 4 Colour with each single LED for architectural lighting with Glue less technology. Luminaire has a choice of architectural flood lighting optics with beam angle of 20-60°, Wattage not exceeding 30 Watt, UV and temperature-resistant lens system. Symmetric distribution, Luminaire luminous flux range 900-1050 Lm . Lumens will be measured in White colour with all 4 channels in ON conditions, with inbuilt decoder .Lumens will be measured in White colour with all 4 channels in ON conditions and IP68 connector. Luminaire Controlled through Wi Fi / DMX/Ethernet controller, Controller can achieve 16.7M colors. Rated input supply of AC 220V constant voltage. Luminaire without control unit. Light color RGBW.Optics to be selected as per the application requirement Mean rated service life L70 (tq 25 °C) > 50,000 burning hrs. Luminaire body of Die-Cast aluminum alloy housing with heat resistant tempered glass cover & Double Powder Coating, outdoor grade, anti-UV glassingress protection rating > IP66 and impact rating 07. The LED system with separate control gear unit is suitable for operation on direct voltage supply grid. Driver Efficiency: >85%, Operating Temperature: -10°C to +50°C, Operating Humidity : 10%-90% The luminanes should have options for various bearm angles i.e. from 20° to 60° actual will depends on the approved design/as per site requirement. Housing to have adjustable base bracket for angle adjustment so that light direction can be adjusted to illumnate-desired structural elements. The LED luminaires and external driver should be CE/BIS certified. The proposed fixture must have passed LM-79 & LM-80 report from NABL laboratory. The must be submitted prior to the supply of material.The work includes all accessories, connectors, wire etc. complete in all respect. (with Three years warranty)The make of LEDCREE/OSRAM/NICHIA/SEOUL MAKE of Lumnaires Philips /Surya /Wipro/ Crompton 75 Each 3 Non BSR SITC of Color Changing Linear wall washer Light RGBW 18 to 20 Watt 4 in 1, 4 Colour with each single LED for architectural lighting with Glue less technology, 4 pixel LED Linear Light suitable for facade Lighting. Surfacemounted for outdoor applications. Luminaire optic consists of highly efficient, UV and temperature- resistant lens system. Symmetric distribution, Luminaire luminous flux range 540 - 600 Lm Lumens will be measured in White colour with all 4 channels in ON conditions, with inbuilt decoder and IP68 connector. Luminaire Controlled through Wi Fi / DMX/Ethernet controller, Controller can achieve 16.7M colors. Rated input supply of AC 220V constant voltage. Luminaire without control unit. Light color RGBW.Optics to be selected as per the application requirement Mean rated service life L70(tq 25 °C) > 50,000 burning hrs. Luminaire body of DieCast aluminum/EXtruded aluminium alloy housing with heat resistant tempered glass cover & Double Powder Coating, outdoor grade, anti- UV glassingress protection rating IP66 and impact rating 07. The LED system with separate control gear unit is suitable for operation on direct voltage supply grid. Driver Efficiency: >85%, Operating Temperature: -10°C to +50°C, Operating Humidity : 10%-90% The luminanes should have options for various bearm angles i.e. from 8° to 80° actual will depends on the approved design/as per site requirement. Housing to have adjustable base bracket for angle adjustment so that light direction can be adjusted to illumnate-desired structural elements. . The proposed fixture must have passed LM-79 & LM-80 report from NABL laboratory. The must be submitted prior to the supply of material. The work includes all accessories, connectors, wire etc. complete in all respect. (with Three years warranty) The make of LED CREE/ OSRAM/ NICHIA/ SEOUL MAKE of Lumnaires Phiips /Surya/Wipro /Crompton 160 Each 4 Non BSR SITC OF 200 WATT POWER SUPPLY make : Meanwell , Nicolaudie, Hengle 25 Each 5 Non BSR SITC and Programming of Content Program Controller, 2X512 Dual universe with digital display Secure Digital (SD) card drive for flexible show storage ,USB 2.0 interface for downloading shows and configuring from PC,-Flexible, adaptable mounting options , Should be provided with light show authoring software, Powered with 5- 5.5V DC power supply, Minimum five configurable effects,Using light show authoring software to select from standard to minimum five effects, adjust effect settings such as color, speed, and brightness. Compatible with System complete in all respect to fullfil the purpose, (with Three years warranty). Make: Nicolaudie/Hengle/Pharos 2 Each 6 Non BSR SITC of DMX splitter cum booster with minimum 4 channel isolated outputs, the splitter can split the DMX signals into minimum 4 directions by boosting the data signals connected in the daisy chain in the network (with Three years warranty). Make Hengle/Nicolaudie/Pharos/Swisson 10 Each 7 Non BSR Supply & Laying/Fixing DMX Data Cable with 2 core shielded cable 2 core X 0.5 Sqmm. CE approved including making connections. Make-Hengle/Dlink/Belden 1200 Mtr. 8 Non BSR Supply and fixing IP67 weatherproof box of minimum size 250x150x125mm for Power Supply with cable glands at input and output of the box, size of the box should be sufficient to accommodate the power supply of the fixtures. 20 Each 9 Non BSR Supply and fixing of Iron Cage size 600 x 200 mm 10 each 10 Non BSR Operation and Maintenance of the complete System with ward & watch Including Programming, testing and commissioning and maintenance of scenes for 3 years with programming of different color patterns as per engineer in charge (Details as per Annexure-A 1 Each

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 50.09 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail