| 1 | Running expenditure of pump house which includes complete operation of pump motor, maintenance of log-books as directed by Engineer-in-Charge, general up keeping of premises, security arrangements, regular chemical dosing in CWR, cleaning and desilting of SR/CWR/SUMP once every six months, daily valve operation under the campus of pump houses and all other work as mentioned in scope of work in tender documen for per pump house per month. (power supply minimum 16 hrs.) |
| 2 | Above 100 HP to 200 HP |
| 3 | Above 200 HP |
| 4 | SITC of 3/4 pole current limiting Moulded Case Circuit Breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz, O/L & S/C settings, conforming to IS/IEC 60947 P-2:2003 with front faceand centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3 having positive isolation capability, push (test) to trip, trip time less than 10 ms under s/c condition, Breaking Capacity ICS =100% ICU, U imp = 8KV, rated insulation voltage 69 V. provision for UVR, Shunt Trip, Earth Fault Trip, Foor Interlock, Pad Lock, & Rotary Handle, Including making connections etc. as required OEM shall have submit NABL/CPRI/ERDA accrediated lab type test certificate before execution all as per pre approved by Engineer-in-Charge for additional technical parameters ofproducts/work refer Annexure \"A\" attached with this BSR |
| 5 | 3 Pole MCCB with thermal magnetic release |
| 6 | upto 100 Amp, 25 kA, adjustable O/L & adjustable S/C setting |
| 7 | 250 Amp, 25 kA, adjustable O/L & adjustable S/C setting |
| 8 | 400 Amp, 35 kA, adjustable O/L & adjustable S/C setting |
| 9 | Provding & Fixing of ISO certified company made on load change over switch, front handle operated four pole 415 V as per PWD specification for electrical works conforming to IS/IEC 60947-3:1999 including connections testing etc. as required in the following rating. Appropriate type test certificate/OEM test report shall be submitted. All as per pre approved by Engineer-in-Charge for additional technical parameters ofproducts/work refer Annexure \"A\" attached with this BSR |
| 10 | Open Execution Type |
| 11 | 125 A |
| 12 | 250 A |
| 13 | Rewinding of three phase squirrel cage induction motor of HSC pump sets including all necessary material and of the same characteristics as original with required size of super enamelled copper wire (including cost of copper wire) \"E\" class insulation material and testing of motor on no load but to be guaranteed against testing on load at site, including making with pump sets and transportation to and from installation site complete as per direction of Engineer-in-Charge |
| 14 | Above 30.00 HP but upto 35.00 HP |
| 15 | Above 35.00 HP but upto 40.00 HP |
| 16 | Above 50.00 HP but upto 60.00 HP |
| 17 | Above 75.00 HP |