}

Tender For Supply Installation Testing Comissioning Of Various Electric Services Of Rajasthan High Court Parking Jaipur. - Sitc Of Electric Driven Sprinkler / Hydrant Pump Suitable For Auto-Matic Operation Consisting Of The Following 3 (A) Horizontal Mu, Jaipur-Rajasthan

Jaipur Development Authority has published Tender For Supply Installation Testing Comissioning Of Various Electric Services Of Rajasthan High Court Parking Jaipur. - Sitc Of Electric Driven Sprinkler / Hydrant Pump Suitable For Auto-Matic Operation Consisting Of The Following 3 (A) Horizontal Mu. Submission Date for this Tender is 30-05-2025. Vehicle Hiring Service Tenders in Jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49099494
Tender For Supply Installation Testing Comissioning Of Various Electric Services Of Rajasthan High Court Parking Jaipur. - Sitc Of Electric Driven Sprinkler / Hydrant Pump Suitable For Auto-Matic Operation Consisting Of The Following 3 (A) Horizontal Mu
Open Tender
Indian
Rajasthan
Jaipur
30-05-2025

Tender Documents

Tender Details

Tender For Supply Installation Testing Comissioning Of Various Electric Services Of Rajasthan High Court Parking Jaipur. - SITC of electric driven Sprinkler / Hydrant pump Suitable for auto-matic Operation consisting of the following 3 (A) Horizontal multi stage Centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary sluice value on the suction side ( all items to be matching the suction side of the pump) and pressure gauge sluice value and non return valve on the delivery side side ( all of the necessary dia) and including bypass arrangement for testing of pump 4 (B) Squirrel cage induction motor suitable for 415 V, 50 HZ, Ac supply of below mentioned HP for the above pump ,1450 RPM T.E.F.C confirming to IP:55 and flexible coupling and coupling guard with the pump. 5 (C) Common bed plate fabricated from mild steel channel or cast iron type 6 2280 LPM at 70 Mtr Head ( 60 HP Motor) 7 SITC of Jockey pump having Squirrel cage induction motor suitable for 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM T.E.F.C type confirming to IP:55 and flexible coupling and coupling guard with the pump ,Common bed plate of fabricated mild steel channel or cast iron type. 8 180 LPM suitable for 70 Mtr Single Stage 9 SITC of pressure switches for Main, Jockey, and standby pumps, including necessary wiring UPTO control panel and stop valve. 10 Supplying and fixing of Electric Flow switch for sprinkler system annunciation 11 Supplying & Installing cylindrical type air vessel, 250 mm dia 1.5M high of thickness 6.0 mm M.S. complete with air release valve, safety valve, pressure gauge etc.along with two coats of Red Oxide and two coat of post office red enamel paint as required. 12 Providing and fixing air release valve with air vessels at the top of Risers. 250 mm dia, I Mtr long 13 Providing & fixing cast iron double flanged type sluice valve of the following size complete with bolts, nuts, washers and compressed asbestos gaskets as required; 14 80 mm dia 15 100 mm dia 16 150 mm dia 17 200 mm dia 18 Providing and fixing non return valve complete with bolts nuts washers and compressed asbestos gasket etc as required : 19 100 mm dia 20 150 mmdia 21 200 mm dia 22 Providing, fixing, testing & commissioning of sprinkler heads of the following type : 23 Pendant type with quartziod bulb, operating temperature at 68 deg C as per specifications. 24 Sidewall Sprinklers (ordinary) 25 SITC of diesel engine drive Standby Pump suitable for automatic operation consisting of the following A, B, C. .The Diesel driven pump shall be suitable for following discharge: 26 (A) Horizontal multi stage centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, sluice value on the suction side (all items shall be matching the suction side of the pump) and pressure gauge, sluice valve and non return valve on the delivery side (all of the necessary dia) and including bypass arrangement for testing of pump 27 (B) Water cooled Diesel Engine developing suitable BHP for the below mentioned discharge at 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump, d cushy foot, damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically with a unit of battery of 12/24v, 88 Ah, 13/21 plate , Exhaust Pipe of minimum 10 M length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumping set, Supply, installation, testing, & commissioning of electric driven automatic pressurization pump set 28 C) Horizontally mounted single stage centrifugal end delivery pump of below mentioned discharge with necessary sluice valve on the suction side (all items matching the suction side of the pump) and sluice valve, non return value, pressure gauge on the delivery side including by pass arrangement for testing of the working of the pumping set as required 29 2280 LPM at 70 Mtr Head ( 60 HP Engine) 30 Providing and laying M. S. (Medium duty B class) pipe IS ; 1239 marked including all accessories such as screwed/ welded flanges, tees, reducers etc. Conforming to IS : 1239 complete including painting, welding, jointing and compressed asbestos gaskets, nuts, bolts etc. as required. The pipe shall be painted with one coat of Primer & two coats of post office red primer paint fixed in ceiling, walls, columns for all heights with hangers/supports and fasteners including chasing of walls/ colums/ ceilings etc. and making good the same complete as required. 31 25 mm dia 32 32 mm dia 33 40mm dia 34 50mm dia 35 65 mm dia 36 MS (Medium duty B class) pipe with cleaning,wrapping and coating of the pipe as per IS; 10221 in all kind of soil at 1.0 M depth including excavation as required. 37 100 mm dia 38 150 mm dia 39 Providing, fixing, jointing and testing of Heavy Gauge ( C class ) MS Pipe ISI marked with accessories like tees, elbows, flanged joints, reducers, compressed asbestos gaskets, nuts and bolts including fixing the pipe with suitable flat iron strip clamps /bracket, painting etc. Complete as required for delivery/ suction manifold relating to the pump including painting of two coats of Red Oxide and two coat of post office red enamel paint including all civil breakages and making good the same : 40 80 mm dia 41 100 mm dia 42 150 mm dia 43 200 mm dia, 6.0 mm thick 44 250 mm dia, 6.35 mm thick 45 Providing & fixing Butterfly valve with Cast Iron Body, Cast Iron Disc and Seat of Nitrile Rubber Bonded on Bakelite with hard back to PN 1.6 rating with following sizes complete with bolts, washers and compressed asbestos gasket as required 46 50mm dia 47 80 mm dia 48 100mmdia 49 150mm dia 50 Providing & fixing 100mm dia pressure Gauge on Pump Delivery Line complete with shut off cock. 51 Providing and fixing single headed hydrant valves with flanged inlet ISI marked with 63 mm female instantaneous outlet of gun metal complete with blank cap and chain conforming to IS : 5290 52 Providing . 63 mm dia 15 M long reinforced rubber hose pipe conforming to IS : 636-1962, Part –A & ISI marked with Gun Metal male & female coupling wire wound with the pipe. 53 SITC Speaker cum electronic Hooter mounted in M S sheet box with perforated front mesh for PA and Emergency System. 54 SITC Photo Electric type Smoke Detector with mounting base. LED, with etc complete as required . 55 Analogue addressable type 56 SITC Manual Call Point complete with , Glass, hammer and chain etc as required: 57 Analogue addressable type 58 Providing and fixing with bracket/ supports etc wall/floor mounted fire extinguishers as per details below: 59 ISI marked 10 kg capacity Dry Powder fire extinguisher with high pressure discharge hose, squeeze gripe nozzle 120 gms carbon dioxide cartridge, gun metal cap with initial charge of dry power. Both extinguisher and dry power to be ISI marked. 60 Providing and fixing charged ABC type fire extingusher including the cost of fixing with nut, bolts etc as required. 61 5 KG 62 SITC of walll/free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator). 63 Supplying and fixing of Aluminium / Copper bus barby means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. 64 Electrolytic grade aluminium bus bar 65 Supply, Fabricating & installing following sizes of perforated M.S. cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting as required. 66 300mm x 50mm x 1.6mm 67 450mm x 50mm x 2.0mm 68 600mm x 75mm x 2.0mm 69 SF ofCurrent Transformer, with all necessary support in existing panel including connection etc. as required . 70 from 2000 / 5to 3200 /5 Ratio , 15 VA, class 1 accuracy 71 P&F of RCBO with overload, short-circuit and earth leakage protection ISI marked (IS12640)/ conforming to IEC 61009/1 complete in all respect including making connections with lugs, testing etc. as required. 72 Four pole 30/100/300 mA sensitivity, 25-40 A rating 73 Four pole 30/100/300 mA sensitivity, 40-63 A rating 74 SITC of wall / floor type following zone (each zone accessing 20 units ) Conventional Type solid state main control panel fabricated from 16 SWG CRCA sheet steel incorporating audio –visual indication for each zone with Public address system complete with 2x250W channel mixing amplifier , Required zone floor selector console, 1-No cardioid goose neck microphone , 1-No professional grade cassette deck 6-way PA selector with “ ALL CALL “, & sealed maintenance free (SMF) batteries of min 42 AH of 2X12 V. 75 5-zone 76 P/Laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required 77 4.0 Sq.mm 3 core flat 78 Supplying and fixing orifice plate made of 6 mm thick stainless steel with orifice of required size in between flange & landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 kg/cm2 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 79 Supplying & fixing 63 mm dia Gun metalbranch pipe with 20 mm (nominal internal diameter) sizenozzle confoming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required 80 Supplying and fixing first -Aid hose reel wall mounted swinging type with MS construction spray painted in post office Red, conforming to IS 884 with upto date amendments, complete with the following as required.(A) 30 m long 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type -2 as per IS: 12585 (B)20 mm (nominal internal) dia gun metal globe valve & nozzle. (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. pipe 81 Supplying and fixingFire Brigade Connection of CI body with Gun Metal male instantaneous inlet couplings complete with cap and chain as required for 150mm dia MS pipe connection, conforming to IS 904 as required of following way : 4 Way 82 Providing and fixing of 4 waysuction coupling for fire brigade withdrawal of water from firetank with150mm dia pipe and foot valve. 83 Supplying and fixing of Hose Cabinet of size 750 mm x 600 mm x 250 mm made of 1.6 mm thick MS sheet with 6 mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 Nos 15 Mtr. Long Hose pipe, 1 No. branch pipe, mounted on wall OR raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrant, as required. 84 Supply & Fixing of Fire Mans Axe with heavy Insulated rubber tested up to 20 KV and confirming to IS ;926 85 Providing & fixing100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg ) range, 3 / 8 BSP bottom entry on Pump Delivery Line complete with Ball valve 86 Supply and fixing of Oil / Air break Starter panel made out of sheet steelpowder coated enclosure comprising of over load protection relay, short circuit & single phasing protection, ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc. complete in all respect suitable for following rating motors. For Three phase Submersible / Mono block pump 87 3.0 HP to 10.0 HP ( Star / Delta ) 88 SITC of ISI marked Submersible mud pump set minimum 20 mm solid handling 2900 RPM , three phase, 415 V, 50 Hz, having following capacity. 89 5 HP, ( 21.5 - 6 ) Mtr. (300 - 1200) LPM 90 Supply , installation testing and commisioning of Digital Voice Command Center withFACP, it shall contain all equipment required for all audio control, emergency telephone system control, signaling and supervisory functions. This shall include speaker zone indication and control, telephone circuit indication and control, digital voice units, microphone and main telephone handset. etc. as required. 91 SITC of6 W Wall Mounted Speakers suitable for addressable type fire alarm system with line matching transformers & selecteable tap setting as required. 92 SITC of6 W ceiling mounted Speakers suitable for addressable type fire alarm system with line matching transformers & selecteable tap setting as required. 93 Part-B: Electrical 94 P & F of energy analyser (multy function energy meter) with LCD/ LED display capable of minimum 20 numbers electrical parameters display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect. 95 SF ofCurrent Transformer, with all necessary support in existing panel including connection etc. as required 96 up to 150 / 5 Ratio , 5 VA , class 1 accuracy 97 from 200 / 5 to 400/5Ratio , 10 VA , class 1 accuracy 98 SF of240/220 V, LED (22.5 mm dia ) Pilot lamp with integral circuit, terminal block, including connection etc. as required. 99 Red/yellow/Green colour 100 Blue / white Colour 101 P & F push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. 102 Non luminous type 103 Luminous type 104 SF of rubber mattingwith one side corrugated as per IS specificationv 15652/2006 105 11 KV,25 mm thick, 106 P & F ofac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required. 107 4 pole AC 1 Ratingcontactors, 46 to 60 Amp 108 3 pole Power contactorswith following AC 3 Rating, Up to 12 Amp 109 3 pole Power contactorswith following AC 3 Rating, 21 to 25 Amp 110 3 pole Power contactorswith following AC 3 Rating, 26 to 32 Amp. 111 3 pole Power contactorswith following AC 3 Rating, 41 to 50 Amp 112 SITC of quick make and quick break4 POLEcurrent limiting MCCB having following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. 113 With Thermal Magnetic Release, up to 100 Amp , 16 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 114 With Thermal Magnetic Release, 160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 115 With Thermal Magnetic Release, 200 Amp ,25/35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 116 With Thermal Magnetic Release, 250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 117 With Thermal Magnetic Release, 630 Amp , 35/50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu 118 Supply and fixing of following accessories for MCCB 119 Shunt trip Release 120 Supply and fixing of following accessories for Air circuit breakers. 121 Shunt Trip Release 122 mechanical interlocing kit 123 P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 124 4.0 Sq.mm, 4 core 125 6.0 Sq.mm, 4 core 126 16.0 Sq.mm, 4 core 127 25.0 Sq.mm, 3.5 core 128 70.0 Sq,mm, 3.5 core 129 185.0 Sq.mm, 3.5 core 130 300.0 Sq.mm, 3.5 core 131 P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. 132 Single pole MCB, 0.5 A to 4A rating 133 Single pole MCB , 6 A to 32 A rating 134 Triple pole MCB,40 A 63 A rating 135 Four pole MCB, 6 A to 32 A rating 136 Four pole MCB, 40 A 63 A rating 137 P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar, conforming to IS13032 & IS8623 including making internal DBterminations with copper lugs , testing etc. as required. 138 Double door (Three phase), 6 Way 139 Double door (Three phase), 8 Way 140 Double door (Three phase), 12 Way 141 Wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm FR PVC insulated unsheathed 1.1kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated copper earth conductor (IS:694) of approved makein double lock/ ISI marked single lock pvc casing capping & its accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board& falce ceiling point,6 A switch 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers ,making connections, testing etc. as required 142 Medium point (up to 6 mtr.) 143 Long point(up to 10 mtr..) 144 Making of hole in wall of required size for housing exhaust fan and making good the same, with cement plaster as required of following size: more than 457 mm & up to 610 mm 145 P & F of capacitor start, three speed wall mounting/cabin fan of following sweep with the help of anchor bolts including making connection testing etc. as required. 400 mm sweep 146 S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall and making good the same as required. 147 20 mm 148 25 mm 149 32 mm 150 SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required. 151 Heavy duty Three phase 440 V , 50 Hz capacitor (Bank) 152 SITC of microprocessor based intelligent power factor correction relay having sensitivity up to 50 milli Amp secondary current and following way, self analysing auto c/k setting according to targeted power factor setting, the relay shall have minimum three digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release etc. as required. 153 6 to 14 stage - sensitivity upto 50 milli Amp 154 P & F Cam operated rotary switches on existing panel with 2 way and off position 155 Three pole, 16 A 156 Three pole, 32 A 157 Three pole, 63 A 158 P & F of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 159 up to 6 KVAR 160 7 to 10 KVAR 161 21 to 30 KVAR 162 31 to 50 KVAR 163 Providing and laying XLPE/PVC insulated & PVC sheathed Un-armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and Iind class bricks covering 164 2C x 1.5 sq.mm 165 3C x 1.5 sq.mm 166 4C x 1.5 sq.mm 167 2C x 2.5 sq.mm 168 4C x 2.5 sq.mm 169 Supplying and making one end termination with heavy duty single compression brass gland SIBG type, aluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size 170 2 x 4.0 sq.mm 171 2 x 6.0 sq.mm 172 3 x 70.0 sq.mm 173 3.5 x 185.0 sq.mm 174 3.5 x 300.0 sq.mm 175 Supplying and making end termination with heavy aluminium lugs (pin/ ring type) duty crimped with crimping tool, PVC tape etc of following size 176 1.5 Sq.mm 177 2.5 Sq.mm 178 4.0 Sq.mm 179 6.0 Sq.mm 180 16.0 Sq.mm 181 70.0 Sq.mm 182 240.0 Sq.mm 183 300.0 Sq.mm 184 P / L of Double wall corrugated HDPE pipe confirming to IS : 14930 P - 1 & 2with HDPE Coupler at 1 mtr. Depth below the ground for laying cable including making the trench and back filling , compaction of earth as required of Gemini or IS:14930 marked make. Outer Dia. / Inner dia. 185 160 / 136 mm 186 P&F of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required 187 P & F of IP67, IK10 protected LED Buried marker light / Step Light with mounting box & integral driver suitable for 3W - 5W, 240V LED with available in quick connectingcable coupled with various mounting accessories. Driver shall be high efficiency having efficiency > 85% and in compliance to IEC standards (Integral with light fixture). system life of 25,000 Burning Hours with 70% of initial Lumens maintained. Light output in Blue, Cool white or Warm White Colour as per engineers choice. Fixtures shall be CE compliance. 188 Step Light LED 189 Part-C: Force Ventilation 190 P/Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 191 4.0 Sq.mm 4 core 192 16.0 Sq.mm4 core 193 S / F of accousting lining of duct work shall includes Anticorrosive treatment, fibre glass wrapping, tissue paper TF, chicken wiremesh of 28G and fixing with GI nut bolts, SITC of MS Powder coated Grill/Diffuser 194 Double louvered supply air grills with dampers. Front louvers fixed & rear louvers movable. 195 SITC of ducting made from GSS of class VIII & fabricated as perIS:677 and as per approved drawings & designs including the cost of hangers, supports , angle , expansion fasteners , T&P as required of following gauge: 196 18G 197 20G 198 22G 199 Part-D: CCTV 200 Supply ,Installation and Testing of 19 Rack mounted/ surface mounted aluminium / CRS powder coated multimode glass Fiber Optic Cable Patch panel/ LIU (upgradable to intelligent panels with use of sensor strips) along with cable tray/ fiber management system , adapters for ST II/ SC/FC/MT/PC connections including making connections (Terminations if required will be paid seperately) to active / passive equipments with ferruling at both ends for identification with necessorry tools for Terminations and testing required . 201 24 Ports 202 Supply , Installation and Testing of 4 pair , 100 Ohm, 24 AWG, Cat 6 UTP, flexible , Double ended Patch Cords along with 2 No of RJ 45 connectors with strain relief boots as per TIA /EIA 568 B.2-1 Specifications including making connections to Information outlets of lengths. 203 1 Mtr/3 ft 204 2 Mtr / 7 ft 205 Supply , Installation, Testing and Comissioning of Rack mounted 19, Cat 6 UTP,1.5-1.6 MM CRS chasis , powder coated Modular Patch Panels (upgradable to intelligent panels with use of sensor strips) with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessory connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps. 206 24 Ports 207 S & F of Faceplate for Flush Mount Information Outlets Single Aperture with screw hole covers & Icon Tree Size t86mmX86mm 208 Supply , Installation, Testing and Comissioning of Wall mounted Communication rack in two sections viz rear wall mount Section and hinged front section with glass doors, swing handles ,lock , Top and Bottom Cable entries,Supports for mounting rack on wall , Cable managers, Fan tray with 2 x 230 Volt fans, Equipment mounting hardware, wire managers , power supply box for supplying power to hubs, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable, Blank panels , sliding shelves etc. 6 U(44 mm ) wall mounted 209 Supply , Drawing and Testing of 4 pair, 24 AWG UTP Cat 6 Cable as per latest ammendments of TIA /EIA 568 B.2-1 Specifications in existing MS/PVC Conduits including making connections to Information outlets and Patch Panels with ferruling at both ends for identification with necessorry tools for punching, stripping, crimpping and testing required . 210 Supply , Installation, Testing and Comissioning of Floor mounted Communication rack in two sections viz rear Steel Door and hinged front section with glass doors, swing handles ,lock on both doors, Top and Bottom Cable entries with gland plates ,Castor with brakes , 7 no Cable managers, 1 no Fan tray with 2 x 230 Volt fans, Equipment mounting hardware, wire managers , power supply box for supplying power to hubs, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable, Blank panels of 1u / 2 u , sliding shelves .Frame of communication rack should be made of heavy grade Aluminum profile PS grey painted and panels should be made from CRCA steel 18 swg RS Beige painted 27 U (44 mm )Floor Standing Rack 211 Supply , Drawing and Testing of Indoor multimode[62.5/125um ] glass Fiber Optic Cable as per latest ammendments of TIA /EIA 568B.3 , GR 409 CORE / UL listed NEC 770 Standards in existing MS/PVC Conduits/ slotted channels including making Terminations to active passive equipments with ferruling at both ends for identification with necessorry tools for Terminations and testing required. 6 fiber 212 SITC of Managed Layer-2 Intelligent Ethernet Switch providing 24 x 10/100/1000 Fast Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with related LAN Base Software 213 Supply , Installation, OTDR Testing & Fusion Splicing of Fiber Multi mode Pigtailof [50/125um OR 62.5/125um] glass Fiber Optic Cable as per latest ammendments of TIA /EIA 568B.3 , GR 20 CORE / UEC 794-1/ EN 187000 Standard Specifications including ST II / SC/LC/MT-RJ/PC connector as per requirements. 214 SITC of SFP,LC connector SX Giga Transceiver (for MM Fiber) 215 Part-E: Smart Parking 216 Providing and laying XLPE/PVC insulated & PVC sheathed Un-armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and Iind class bricks covering 3Core 2.5 Sq. mm. 217 Part-F: Approved Non BSR items: 218 SITC of IP based 5MP outdoor type IR verifocal Bullet/Dome Camera (2.8mm Lens with Aperture of F1.6 ) 1 / 2.8” -SONY -CMOS5MP ,0 LUX with IR LED ON Horizontal Field of View: 107 degrees and IR Range of up to 30 meters Video Analytics: Trip Wire, Intrusion Detection and Motion Detection H.265/H.264/MJPEG Video Compression,BIS,CE,FCC,IP67 and RoHS PoE Support, NAS Storage, Quad Stream Support True WDR, 3D Noise Reduction, Adaptive Streaming, Smart Streaming and ROI, SNR > 70 dB BIS, CE, FCC, RoHS, IK10 ,IP67,Cyber Security Features: STQC Certified 219 SITC OF 32 Channel NVR with 4K Support 32 IP Channel Inputs; HDMI, 1/1 Audio I/O and 2/1 Alarm I/O, 12MP, 8MP, 5MP, 4MP, 3MP, 2MP, 720p, D1 and CIF Recording Resolution, 4x 4K/ 10x 3MP/16x 1080p Local Decoding, 6 SATA HDD Support (Maximum 10TB Capacity, Hard Disk Not Included), Save Storage Space with Adaptive Recording and Camera-wise Recording Retention, SMS & Email Notification, Video Pop-up, Alarms and Calling from Mobile Application 512Mbps Throughput - 256 Uplink, 256 Downlink; Cascading: Create Mutiple NVR Clusters to Monitor and Control Multiple NVRs Centrally, ONVIF, Certification complied: BIS, CE, FCC, RoHS. 220 Supplying and fixing of 10TB Surveillance HDD Make:Seagate/WD 221 SITCof Automatic boom barriershall be consisting of following specifications. Barrier Front Design: Round/Ractangle Barrier, Colour : Silver/Grey Colour, PARKI Electromechanical Drive ,Mechanism 3-6 meters boom arm Illuminated, Boom Arm (Red/Green) ,Opening Speed : 1.5 Sec Reverse on Obstable Detection , intelligent control mechanism, Automatic Fault Detection Arrow , Led Indication on barrier body (Red/Green) ,Duty Cycle 100 %, IP Rating : IP 55, RS 485 Communication complete in all respect. 222 SITCofLong Range Reader shall be consisting of following specifications , Hands Free Frequency Range: ISM 865~868MHz or ISM 902~928MHz ,Operation Mode: FHSS Data Ports: Wiegand26/34, RS485, RS232, RJ45 ,Reading Range: 12m ,Reading Clue: Buzzer Antenna,Built-in line polarization Operation Temp -20℃ to +80℃ ,Access Controller : NAC 25, 2 reader controller, Card holder: 54000 cards, Logs: 60000 records,Alarm events:10000 events, Communication: TCP/IP, Verification: card, card and timing. Release button, Remote opening from software, timing. complete in all respect. 223 SITCofLoop Detector shall be consisting of following specifications ,Vehicle sensing unit with 2 channel sensing option, 24 V DC/24 V ACpower supply ,designed D MAX chipset 3 level frequency adjustment, 3 level sensitivity adjustment ,IP protected Enclosure, Presence relay (N.O./N.C.) Multi-function signaling LED Operating ambient temperature -20°C to 60 °CC,NO,NC. 3 Poles, Communication : RS485/Ethernet complete in all respect . 224 SITCofAndroid Based Touch Screen Terminal (Without Application) shall be consisting of following specifications Sleek compact design Built-in contactless reader Android based Intelligent operating system NFC, Bluetooth, sound wave sensor 1.2 m Fall protection Large Colour Touch Screen display in built High Speed Thermal Printer Support WIFI, 3G, 4G Build powerful network High capacity battery 5200mAH complete in all respect. 225 SITCofBluetooth Barrier Integration Module for parking management system complete in all respect. 226 SITCofWEB Based Parking Software Fieldmonitoring deviceshall be consisting of following specifications. Realtime transection detailsReport, Management Tariff Configuration,Shift Management Event and Alarm Mangement complete in all respect. 227 SITCofMain Entry Information Display ( Four Row Display)shall be consisting of following specifications Multi-Colour LED Matrix Display unit Cabinet Colour : Black/White Cabinet Dimension : 1800 mm x 600 mm x 250 mm LED Color : Red /Green Super bright. Communication : Wireless Communication Led Type 5mm OvalLogic card Visibility 120mtr Brightness 2000 MCD Enclosure Weatherproof IP gradeCPU Speed 100 MIPS complete in all respect 228 SITC of Inductive Vehicle loop sensor shall be consisting of following specifications . Loop wire single core 1.5 sqmm Electromegnectic induction coilspecialized loop sensor design loop size 2m X 1 cutting depth 20 mm cutting width 15 mm rectangular box with 2 x 1 with chamfered cutting edge Four turns in rectangular shape 3 level sensitivity adjustment complete in all respect 229 SITC Of Parking Guidance SystemSoftware Intel I3, with 3 MB cache, CPU 4460@ 3.2 Ghz, 4 GB RAM, 1 TB HDD 19 LCD Monitor, Keyboard & Mouse Microsoft Windows XP Professional license Laser Printer parking Guidance Software Parking Graphical represantation Long stay vehicle indication Average parking time Parking area with alarm and event monitoring Report Management Graphical representation based on actual layoutDrawing Report Management for better parking operations Average traffic flow daily, weekly, monthlyDifferent Color indication on software as per time spent in parking Manage and control each parking guidance device through software Floorwise parking count status, Vacancy status Toll free number for parking status through SMS (Optional) Additional hardware integrationpossiblity Cloud Application with server, hosting, domain maintainance for 5 years Complete in all respect 230 SITC Of Parking InformationVehicle Counting Module Vehicle Counting Device 24 Vdc/24 Vac power supplyIP protected Enclosure Presence relay (N.O./N.C.) Multi-function signaling LED operating ambient temperature -0°C ÷ 60 °,NO,NC. 3 Poles Communication : RS485/Ethernet 231 SITC ofRS-485 cable fortransmits digital information between multiple locations. Data rates can be up to, and sometimes greater than, 10Mbps. RS-485 is designed to transmit this information over significant lengths. 232 Supply, Installation, testing and commissioning of AMCA Certified (For Air and Sound Performance) long casing tube / vane axial flow Exhaust fan of different capacity as mentioned below in standard M.S. construction. Entire fan model & AMCA Seal shall appear in technical submittal of fan. All the fans are synthetic enamelled painted/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-3 type) confirming to IS - 325-IP - 55 with class `H insulation. Motor shall be of high temperature resistance Class H Smoke Spill 250° C for 2 hrs. Fan shall be TUV / CE/UL Certified for high temperature. Fan shall be EN 12101-3 Certified high temperature. Motor should be VFD rated. Motor make shall be same as mentioned on the fire certificate. Fan efficiency should not be less than 70%. Noise level should not more than80 dB @ 3 mtr distance when measured in hemispherical reverberant room conditions, for normal (non-fire) conditions, and not more than 85 dB @ 3mtr distance for fire conditions. Fans should be as per specification and drawings 233 Basement - Upper -- Exhaust Fans, 35000 CFM @ 25mmWC, normal conditions 234 Basement - Upper -- Exhaust Fans, 35000 CFM @ 25mmWC, fire conditions 235 Basement - Lower-- Exhaust Fans, 35000 CFM @ 30 mmWC, normal conditions 236 Basement - Lower-- Exhaust Fans, 35000 CFM @ 30 mmWC, fire conditions 237 Providing, fixing, testing and commissioning of AMCA Certified (For Air and Sound Performance) long casing tube/ vane axial flow fresh air fan of different capacity as mentioned below in standard M.S. construction. Entire fan model & AMCA Seal shall appear in technical submittal of fan. All the fans are synthetic enamelled painted/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-3 type) confirming to IS - 325-IP - 55 with class `F insulation. Motor should be VFD rated. Fan efficiency should not be less than 70 %, noise level should not be more than 80 db @ 3 m distance when measured in hemispherical reverberant room conditions. Fans should be as per specification and drawings 238 Basement - Lower-- Fresh Air Fans, 35000 CFM @ 30 mmWC, normal conditions 239 IMPULSE JET FANS Jet Fan shall be provided with Dual Speed smoke spill motorwith class H insulation for smoke extraction. Motor shall besuitable foroperation on 415±10% volts, 50Hz, 3 phase AC power supply and capable to withstand250 deg C temperature for a minimum duration of 2 hours. The Impeller of jet fan shall beAirfoil design with High efficiency blades. Fans shall be supplied with 2D silencer on both sides of the fan for Quite operation.The motor make of smoke/exhaust fan shall be same as mentioned on the fire certificate of the fan provided by international independent laboratory under certifying authority. Fan shall be AMCA Certified for Air and Sound Performance.Sound level of the fan should be certified along with the silencer. The fan shall be CE/UL/TUV Certified for smoke control and exhaust applications as per EN 12101-3and drawings 240 Basement Upper & Lower- 315 mm dia 241 CFD Analysis Report 242 SITC of CO Sensor transmitter- online, continuous monitoring of CO and radicals concentration in ambient air, measuring range: 0-300 ppm CO with electro-chemical galvanic (Gel electrolyte) technology, sensor should be UL2075 certified, response time t90 < 30 sec, with anti-sleep feature, capable of providing multiple threshold to identify normal mode, invisible smoke mode and fire mode. It should provide both analog output and digital communication via RS485 serial interface with Modbus RTU. It should be uniquely addressable and suitable for connection in digital communication bus. Enclosure should have minimum fire retardant UL94: V0 rated with IP65 protection. Sensor cell should be plug-in, field replaceable, sensor life expectancy > 7 years, replaceable sensor cell, CE certified. It Should confirm to EMC- Directive 2014/30/EU and drawings 243 Basement - Upper & Lower 244 SITC of Control Panel with PLC based-combined single panel with fan starter and PLC modules, with self diagnostic feature of overload, cable heating, over temperature, inbuilt smoke detection and alarm.Control system should based on programmable logic controller (PLC) with RS485 serial interface over ModBus RTU open protocol digital communication,capable of configuring multiple threshold for each sensor to identify and trigger normal ventilation, fire mode etc. It should work in closed loop, feedback mode with sensors, with auxiliary power supply to the sensor transmitters. It should be easily integrated with BMS (from Master PLC Module) providing all parameter values including fan status, sensor values, threshold status, fire command etc. It should accept and offer command to & from fire alarm system.Programmable to run and control fan (Jet Fans, Axial Fans) operation in normal, early fire, ventilation and fire mode based on sensor values or fire alarm signal or BMS signal or Manual operation. Configurable to control fan operation of any zone based on trigger of sensor of any same or other zone.It should have closed feedback signals for fan status, fan error etc. It should have overvoltage, over current, phase protection features. Fan should be operable in Manual / Auto fan mode. Panel should be equipped with emergency stop mushroom type push button for emergency stop condition.Panel should equipped with over voltage, over current, phase protection, short circuit protection with motor starter based on DOL / Star - Delta. Bus bar should be hot sleeved with suitable rating. Cable entries provided from top 245 FIRE FIGHTING PANEL -SITC of cubicle Indoor type totally enclosed freestanding type dust & vermin proof LT panel made out of 2.0mm thick and partition madeout of 1.6 mm MS sheet steel, suitable for 3phase , 4 wire , 415 V , 50 Hz , AC supplycomplete with incoming ACB / MCCB / SFU &outgoing MCB / MCCB / SFU , All the MCCBshould be with Rotary handle, Four PoleElectrolytic grade Al busbar of requiredcapacity, indication lamp etc complete as perdrawing, enclosed specifications andrecommended makes. 246 INCOMING 247 500Amp, TP, 36 KA, MCCB having Thermal Magnetic release with adjustable overload , & short circuit protection - 1 no 248 BUSBAR 249 750 Amp, TPN,E91 grade AL busbar for mainMCB outing & feeders distribution. The Bus Bar section should be covered with withdrawable Acrylic sheet for protection. 250 OUTGOING 251 200 Amp, TP, 25 KA, MCCB with neutral link, having Thermal Magnetic release with adjustable overload , & short circuit protection, Automatic DOL Starters complete (with over load relay and single phasing preventor feature). ON/OFFTRIP, indication lamp, contactors etc. suitable for 37 KW motor (2 No. main fire pump). - 2 nos 252 160 Amp, TP, 16 KA, MCCB with neutral link, having Thermal Magnetic release with adjustable overload , & short circuit protection, Automatic DOL Starters complete (with over load relay and single phasing preventor feature). ON/OFFTRIP, indication lamp, contactors etc. suitable for 25 KW motor (1 No. Curtain fire pump). - 1 nos 253 40 Amp, TP, C curve, MCB, DOL Starter (withover load and single phase preventorfeature). ON/OFF &TRIP, indication lamp, contactors etc. suitable for 5.6 KW motor (2 No. Jockey Pump). - 2 nos 254 32 Amp, TP, C curve, MCB, DOL Starter (withover load and single phase preventorfeature). ON/OFF &TRIP, indication lamp, contactors etc. suitable for 3 KW motor (1 No. Terrace Pump). - 1 nos 255 40 Amp, FP, 10 KA, C curve, MCB - 2 nos 256 METERING SECTION 257 DIGITAL Energy meter of rating with 3nos 500/5A class 1 CTs as per SLD, The Digital meter shall measure V /I /F /PF /KW / KVA /KVAR / KWH / KVAH / KVARH parameters. The energy meter should have communication port & required hardware & software for communication, duly protected by 2A MCB - 1 nos 258 DIGITAL type Ammeter of rating (0-200amp)as per SLD duly protected by 2A MCB - 3 nos 259 DIGITAL type Ammeter of rating (0-100amp)as per SLD duly protected by 2A MCB - 3 nos 260 LED type RYB indication lamp ( Red/ Green/ Amber) for On/Off/ trip indication duly protected by 2A MCB– 4 Nos. 261 Current transformer ofas per SLD - 4 SET 262 WIRING 263 Set of control system to make thesystem automatic asper functional requirements. 264 Provisionforstartingthefire pump.The fire pump shall start automaticallyin the event ofpressure dropbeyond preset limitonpumps to start and logic necessary for automatic start. 265 Supplying, installing, testing and balancing of Non return gravity dampers for exhaust fans, suitable for withstanding fan velocity & pressure, with smooth movement 266 Supplying, installation, Testing and commissioning of the passenger having following main features:(a) MOTOR : Gearless lift drive comprising of high starting torque lift duty, 3 phase 440 Volts A.C. permanent magnetic synchronous motor of proper rating with high efficiency shall be used.(b) Operation/Drive : Microprocessor based /PLC, AC Variable Voltage variable frequency variable speed (V3F) vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full collective selective operation hall call demand response, UP/Down hall stops, main, Up/Down contactor with overload and phase reversal relay and safety controls.(c) Traction Media: main hoist flat coated steel belt / rope. Thimbles of spring permit adjustment of uniform tension for smooth operation of the elevator Pulse belt monitoring system to avoid the cut in the belt.(d) Car : car should be with M S platform with bracings of adequate size and to sustain the impact load cabin plus passengers with safety factor of fire for steel with Anti-skid PVC flooring and side panels should be of Stainless steel with hair line finish of sheet of grade 304 duty with S.S. handrails . Car ceiling shall be steel finish with aesthetic appearances with LED ceiling lights.The size of the car shall be taken as per available lift well size and relevant BIS code of lifts. Car panel will also be of S S 304 grade finished with emergency stop device, emergency alarm, mechanical door safety device, full length infra-red curtain in car door, facility of auto/attended mode. All car panel buttons and all floor switches must be with brail language as per lift act. Agency shall also provide & install one No. 2 MP , IR , IP based ceiling mounted Dome Camera in the car complete with connecting cables & accessories (To be connected with existing CCTV system in the Building) .The inspection unit shall be provided at the top of the car.(e) Landing Doors: All landing door shall be fully automatic centre opening / telescopic made of hair line finish stainless steel grade 304 with key holes and infrared curtains with unlocking facility from outside.(f) Emergency light: Appropriate rechargeable battery-operated LED emergency light in the car and along with alarm switch shall be provided. (g) ARD: Automatic rescue Device (ARD) shall be provided according to passenger capacity with SMF batteries of approved brands as per BSR. (h) Audio-Visual Indication: Audio visual indication in the lift car, showing over loading such that doors kept open till excess load is removed. (i) Scrolling Indicators: Digital scrolling indicator system for up-down arrow with floor position indicator shall be provided inside the car and at all stops/floors. (j) Buffers: Spring buffers/PU Buffers shall be provided. (k) Car Fan: ENERGY EFFICIENT Car fan/blower with automatic sleep timer shall be provided. (l) Voice Annunciator: Voice annunciator with suitable music shall be provided in lift car.(m) Self diagnostics system for operational and safety parameters shall be provided in control panel.(n) Mechanical/Electronic over speed governor, door key holes in the floor doors, fireman switch shall be provided. Door, Lifting hooks as required and monkey ladders for lift pit should be provided by the agency along with all other steel structure works, foundations for the machine etc as required.(p) Permanent wiring in lift well with safety protection as required. (s) Agency has to provide all working drawings and documents to comply latest BIS specifications and make proper liaison services for obtaining all necessary permissions. 267 15/16 passengers/1020/1088 Kg, 3 stops, rated speed Adjustable up to 1.0 mtr /sec 268 SITC of 55 4k Resolution or Better LED TV with remote control and wall mount unit / floor stand complete with making connections etc. as required. 269 Providing, installation, testing and commissioning of ONLINE UPS SYSTEM, Single Phase 230 V, 50 Hz with 2 hour backup SMF battery bank 270 Workstation latest Intel® i5 processor, Intel Chipset motherboard, 08 GB RAM, 1 TB SATA HDD at 7200 rpm, with 2 x 4GB GPU type higher end Graphic card for H.265 compression technique with dual display ports/DVI/ HDMI port, Giga LAN Card, wireless Keyboard, wireless optical Mouse. All as per pre approved by Engineer in-charge. 271 Supply, installation, Testing and Commissioning of 1000 base-LX/LH single mode/Multi mode fibre to 1000 base-T copper giga bit , Media Convertor complete as required complete in all respect. All as per pre approved by Engineer in-charge. 272 Supplying, installing and balancing of extruded Aluminium powder coated fresh air inlet louvers with bird screen & volume control damper fixing with steel screws etc. complete in all respect. All as per pre approved by Engineer in-charge. 273 Supplying, Installation, Testing & Commissioning of Electrical Driven fire fighting duty Terrace pump as per TAC and IS 12469-1988., Factory assembled in Pump make OEM suitable forautomatic operation and consisting of following details given as A,B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - C ast Iron, Impellor - Bronze, Shaft - SS 410, Packing - Mechanical Seal (C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of requiredHP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect . (D) Common bed plate fabricated from mild steel channel for installation of pump and Motor including anti vibration pads. (E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’srepresentatives. (F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeve and Dynamic Balance certificate is to be submitted by OEM (G) Suitable size Reinforced cement concreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra ) (H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in-charge. 274 900 LPM with 35 mtr head 275 SITC of UL listed / FM Approved Brass Test and drain valve assembly for sprinkler system comprising of 3-position ( off, test and Drain ) ball valves with drain orifice having K-factor 5.6 and maximum working pressure 300 PSI and Inbuilt sight glass etc. as required of following size. All as per pre approved by Engineer in-charge. 276 50 mm Dia. 277 Providing and fixing signages as per required content printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating with suitable colour combination (Glow in dark) with high intensity properties for indoor surface glow visibility not less than 6 hrs. in total darkness and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects required. All as per pre approved by Engineer in-charge. 278 Double sidedsignageboard 279 Supplying and drawing Fire Resistant flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. 2 x 1.5 Sq.mm Unarmoured With Outer Sheath in Red Color 280 Supply, Installation, Testing & Commissioning of ANPR (Automatic number Plate Recognization Camera + 1 illuminator Hardware accelerated, built-in motion detection Auto day & night switch; adaptive settings to environmental settings Automatic time synchronization (NTP) Adjustable image compression for max LPR performance Still images (JPEG) and compressed live video streams (MJPEG) Powerful IR illumination while low power consumption Extreme operation environments: IP67 rating. including power supply & suitable mounting clamp, etc. complete. 281 P & F of Fire retardent , non porous double layer Canvas of required size with GI frame ,Gasket Nut Bolts for air cooling Plants/AHU/FCU etc complete with making connections etc as required All as per pre approved by Engineer in-charge. 282 Part-G: Operation and Maintenance 283 Secondand Third Year O&M (Within DLP)With Min. 3 Nos. Skilled Manpower for parking electrical services during Parking Hours to operate and maintain all services) 284 Forth Year O&M(After DLP) With Min. 3 Nos. Skilled Manpower during Parking Hours to operate and maintain all services)

Key Value

Document Fees
INR 2000 /-
EMD
INR 1367320.0 /-
Tender Value
INR 6.83 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail