| 1 | Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P completo in all respect including required all material, labour etc. |
| 2 | Transportation, Erection and Dismantling of Rig Machines |
| 3 | Drilling of 600mm size bore from GL to 80 BGL |
| 4 | Drilling of 450mm size bore from |
| 5 | 80 M BGL to 160 M BGL |
| 6 | Tubewell Assembly |
| 7 | M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. |
| 8 | 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. |
| 9 | 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. |
| 10 | Supply of pea gravel |
| 11 | Logging of bore hole by departmental/approved electric logger. |
| 12 | Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. |
| 13 | Lowering of 300mm dia pipe from GL to 80m deep BGL. |
| 14 | Lowering of 200mm dia pipe from 80 to 150m deep BGL. |
| 15 | Development of Tubewell by compressor |
| 16 | Transportation, Installation and Dismantling of 350 PSI Compressor |
| 17 | Development of Tubewell by 350 PSI Capacity Air compressor |
| 18 | Development of Tubewell by O.P. Unit |
| 19 | Transportation, Installation and Dismantling of 3 Cusec O.P. Unit & Yield Test. |
| 20 | Development of Tubewell by 3 cusec O.P. Unit |
| 21 | Chemical and Bacterological test of water sample from depaprtmental/ approved lab. |
| 22 | Site clearance and gravel shifting and brickwork/cc dismantling work |
| 23 | baricading/fencing of the site during the construction of T.W. to ensure that site is not exposed to risk of accident |
| 24 | S/F of Dozing pumping set, Discharge 6LPH, Pressure 3.5 to 5 kg/cm2 with 100 Lt. ISI Mark |
| 25 | Extraction of old Pumping Plant |
| 26 | Installation of Pumping Plant |
| 27 | S/Grouting of wooden mica board fitted on MS frame 3\"x4\" |
| 28 | Commissioning of all electrical equipments on mica board with suitable ISI Havells insulated cable |
| 29 | S/o of Armoured Cable 70 mm x 3.5 mm core ISI mark Havells |
| 30 | S/F Copper Flat Cable 03 core 10 mm2 Finolex/Havells |
| 31 | Lowering of 30 HP pump set with T&P |
| 32 | Connection of new boreto Water supply line to distribution line |
| 33 | Dismentling of Old tiles road i/c all comp work |
| 34 | Dismentling of CC/dammer road i/c all comp work |
| 35 | Excavation fo earth in Hard Soil i/c refilling after Complition of work |
| 36 | S/f of 150 mm dia MS Pipe B-Class |
| 37 | Labour charge for laying 150 mm dia MS Pipe Line |
| 38 | S/f of 150 mm dia MS Flange |
| 39 | S/f of 150 mm dia Rubber Flange |
| 40 | S/f of CID Joint 150 mm dia Complete i/c rubber ring and nut bolts |
| 41 | S/f of Ci Bend 150 mnm dia |
| 42 | S/o of Sluice Valve 150 mm ISI make PN 1.6 |
| 43 | S/f of Nut & Bolts 5/8x3\" |
| 44 | PCC 4:2:1 with Stonegrits, Coarse sand & Cement& Labour Charges etc. |
| 45 | Relaying of old ILT i/c all complete work |
| 46 | S/Laying of 80 mm thick ILT i/c all comp work |
| 47 | L/c for line interconnection with all material like as clamp nut & bolts etc. |
| 48 | Construction of Pump house |
| 49 | (1001) Excavation in ordinary soil (loam,clay foundation in or sand) including lift up to 1.50 m& lead up to 50 m,refilling,watering and ramming of trenches or evcavated earth into the space betwwen the building and sides of foundation trenches or into th |
| 50 | (1009) Concrete with 40 mm gauge brick ballast,local sand and cement in proportion in 12:6:1 in foundation including supply of all material, labour T & P etc. required for proper completion of work. |
| 51 | (1029) Ist. Class brick work in 1:6 cement and local mortar in foundation and plinth including supply of all material, labour T & P etc. required for proper completion of work. |
| 52 | (1025) R.C.C. work with cement,coarse sand and 20 mm gauge approved stone ballast in proportion of 1:1.5:3 in sun shed and lintel on doors and windows excluding supply of reinforcement and its bending but including its fixing and binding the same with 0.5 |
| 53 | (1190) 12 mm thick plaster with cement and local sand mortar 1:4 over brick work minimum thickness not to be less than 10 mm including supply of all material, labour T & P etc. required for proper completion of work. |
| 54 | (1151) M. S. or iron work in plain work such as R.C.C.or R.B. work (when not included in over all rates) brought to required shape as necessary including bending for proper completion of the work including supply of steel and its wastage. |
| 55 | (1202) 25 mm thick 1:2:4 plain ceme concrete floor with cement coarse sand am 20 mm gauge stone ballast laid in panne finished with 3 mm floating coat of ne cement or cement and marble dust in rat 1:5 as specified and and removing a overlaping or mortar a |
| 56 | Finishing walls with two coat over primary coat exteior paint apex(Asian of equivalent make) as per specification of the manufacure and required shade to give an even shade including supplymaterial, labour T & P etc. required proper completion of work. |
| 57 | (1253) White washing three coat includi supply of all material, labour T & P e required for proper completion of work. |
| 58 | (1232 & 1233) Painting or varnishing ne work or new wood work in small areas wi one priming coat and two coat of approve quality paint or varnish including supply of material, labour T & P etc. required for proper completion work. |
| 59 | Providing & Fixing of fan, LED light & switch board with suitable copper wiring for light fitting i/c all complete work |
| 60 | Providing & Fixing of granite stone/MS board for inaugration of tubewell i/c all complete work |
| 61 | Supplying and Laying of grass for park, repairing of dismentel old tiles & cleaning of malba from site after completion of work |
| 62 | GST |