| 1 | fo|qr forj.k [k.M&[kqtkZ ds vUrxZr uxj fudk; ;kstuk ds vUrxZr {kfrxzLr chlhch cnyus] 33@11 dsoh0 midsUnzksa dk lq}hdj.k] izksVSD\"ku yxkus bR;kfn laca/kh dk;Z |
| 2 | Safe carriage of store material from store center to Pit site with loading & unloading at both ends respectively without contractor porvading all item distance within- 0 to 50 Km |
| 3 | 11 KV VCB N/G CTR 200/100/5 |
| 4 | 11 KV VCB N/G CTR 600/300 5A |
| 5 | 1*240 SQ MM SINGLE LEAD |
| 6 | 1*400 SQ MM SINGLE LEAD |
| 7 | 1*1000 SQ MM SINGLE LT LEAD |
| 8 | 1*100 SQ MMSINGLE LEAD |
| 9 | 1*630 SQ MMSINGLE LEAD |
| 10 | 11 KV doFUSE SET |
| 11 | 11 KV CT 600/300/5 |
| 12 | 11 KV CT 400/200/1 |
| 13 | 11 KV PT |
| 14 | 33 KV CT 400/200/1 |
| 15 | 24 VOLT BATTER set |
| 16 | 24 VOLT BATTER CHARGER |
| 17 | 33 KV CONTROL PANEL SINGLE T/F |
| 18 | Safe carriage of store material from JE Store/Sub Station to Pit site as per site requirtement with loading & unloading at both ends respectively without contractor porvading all item distance within- 0 to 30 Km |
| 19 | 11 KV VCB N/G CTR 200/100/5 |
| 20 | 11 KV VCB N/G CTR 600/300 5A |
| 21 | 1*240 SQ MM SINGLE LEAD |
| 22 | 1*400 SQ MM SINGLE LEAD |
| 23 | 1*1000 SQ MM SINGLE LT LEAD |
| 24 | 1*100 SQ MMSINGLE LEAD |
| 25 | 1*630 SQ MMSINGLE LEAD |
| 26 | 11 KV doFUSE SET |
| 27 | Laying sagging stringing and binding and jumpering etc of following Conductor/ABC/XLPE of size on the newly erected poles as per RESPO manual and as per direction of Supervising Engineer. It includes the cost of labour, T&P, carrier etc. required for proper completion of work. |
| 28 | 11 KVXLPE CABLE (3X185) sq.mm |
| 29 | Providing, fabricating carrying & fixing of Henley type Tailless Fuse Unit hook type arrangement single circuit having 3 Phase + Neutral arrangement ( 1 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 300AMP capacityin box) in frame made of 70cmX50cmX6mm frame MS angle boxwith heavy duty Aluminium lugs suitable for 300 Amp load on at least 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle frame support on Pole horizontially/vertically as per site requirement on available pole support at safeheight as per site conditions for electrical safety with making the connection at 100 kva T/f and Line side complete. All material except T/F LT PVC cable be provided by the contractor. |
| 30 | Providing, fabricating carrying & fixing of Henley type Tailless double circuit Fuse Unit hook type arrangement having 3 Phase + Neutral arrangement in each leg ( 2 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 500AMP capacityin box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 500 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safeheight as per site conditions for electrical safety with making the connection at 250 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor. |
| 31 | Providing, fabricating carrying & fixing of Henley type Tailless double circuit Fuse Unit having 3 Phase + Neutral arrangement in each leg ( 2 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 600AMP capacityin box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 600 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safeheight as per site conditions for electrical safety with making the connection at 400 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor. |
| 32 | Providing, fabricating carrying & fixing of Henley type Tailless triple circuit Fuse Unit hook type arrangement having 3 Phase + Neutral arrangement in each leg ( 3 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 800AMP capacityin box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 800 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safeheight as per site conditions for electrical safety with making the connection at 630/1000 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor. |
| 33 | Mounting of 11 KV VCB Sub Station to Control Room by Hydra and manual Labour. |
| 34 | Mounting of 11 KV VCB Sub Station to Control Room by Hydra and manual Labour. |
| 35 | Fixing/Installaiton of 11 KV VCB |
| 36 | Fixing/Installaiton of 11 KV VCB |
| 37 | removal of tranformer from damaged plinth to trolly |
| 38 | repairing of old plinth with material sand brick etc. as per site requirement |
| 39 | reinstalling of transformer kept on trolly to plinth |
| 40 | Fixing of 11 KV do FUSE SET |
| 41 | Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place. |
| 42 | Providing andFixing of Chemical Earthing including all material |
| 43 | Providing and installing OF MS STRIP fencing/angle (65x65x6) sq mm of size 6.5x6.5x9 ft. with proper grouting and completion of work. |
| 44 | Providing and fixing of Water Level Earthing |
| 45 | Providing and fixing of Lug 250/400/630/1000 kva |
| 46 | Providing and fixing of Bus bar brass |
| 47 | Providing and fixing of Bus bar Aluminium |
| 48 | Fixing of 11 KV CT 600/300/5 |
| 49 | Fixing of 11 KV CT 400/200/1 |
| 50 | Fixing of 11 KV PT |
| 51 | Fixing of 33 KV CT 400/200/1 |
| 52 | Fixing of 24 VOLT BATTER set |
| 53 | Fixing of 24 VOLT BATTER CHARGER |
| 54 | Fixing of 33 KV CONTROL PANEL SINGLE T/F |
| 55 | Construction of safty wall between two power transformer at different substation with materai such as sand,brick etc. of size 5x4.5 sq mt |
| 56 | Construction of safty wall between two distribution transformer kept at same plinth at different locations with materai such as sand,brick etc. as per respo norms |
| 57 | Carrige of all dismantle material site/substationto store center BSR. |
| 58 | Providing and installing OF MS STRIP fencing/angle (65x65x6) sq mm of size 4.5x6.5x9 ft. with proper grouting and completion of work. |