| 1 | (a)M&L for dewatering and cleaning of olympic size swimming pool and diving pool, floor, steel ladders and wall tiles with PVC brushes, wipers, surf and tetrachloride acid completely cleaning the ceramic tiles of swimming pool and washing with hose pipes complete rubbing the side walls and including buffing steel grill and floor for entire staisfaction ofEngineer-in-charge. (b) Cleaning of main pipe line from deep pool to balancing tank with pressure water and flushing out the all deposited and settled impurities, through balance tank and outlet pipe of balancing tank etc complete all as specified and directed.(c) Necessary scaffolding deemed to be inclusive for cleaning walls, floors, channels to entire swimming pool.(d) The quoted rate shall deemed to be inclusive of all tools and plants and all required chemicals & labours for cleaning etc as required at site. |
| 2 | Cleaning of balancing tank walls, bottom and top with soft brushes, taking out the settled impurities at bottom complete drying and sterilizing the complete tank to make it bacterial growth free firstly using plane water and secondly with the bleaching powder minimum 100 kg complete all as directed. |
| 3 | M&L complete servicing of filter plant discharge capacity of 27500 GPH including opening of plant cover and replacing gasket packing and back washing the filter plant, taking out filtration plant media like gravel and sand from the existing filtration plant for washing properly the old useful filter media by water pressure or any suitable method including loading the washed filter media and also cleaning of inner portion of the pressure filtration plant using clean water and scraping the dust, silt from inside the filtration plant and cleaning of perforate pipe and nozzles with complete process and replacement of rusted nuts and boltsand servicing of all control valves for inlet and outlet for proper filling of swimming pool including painting of outer surface offilter plant alongwith inlet and outlet after scrabing of old rusted paint andapplying one coat of red oxied primer and two coats of RFU paint of filter plant complete all as specified and directed. |
| 4 | M&L refilling new filter media for topping up/making up the unservicable media of various silica grade as directed at site without any breakage in inner assembly for the followings :- |
| 5 | Sand Media 32 x 64 |
| 6 | Sand Media 16 x 32 |
| 7 | Sand Media 8 x 16 |
| 8 | M&LSpray Nozzle |
| 9 | M&L for repair, servicing, and overhauling of air compressor of entire backwash air blower system of existing size and replace the unserviceable parts duly varnished, baking, providing with top up of engine oil all as specified and as directed by the Engineer-in-Charge. |
| 10 | M&L surface dressing not exceeding 15 Cm deep by cutting /removing of bushes, vegetations/trimming of trees all around the installation, water storage tanks, panels and bore well including clearing of drains from mud/ vegetations clearing the site and burning the waste materials in the presence of Engineer-In-Charge. |
| 11 | S&F in replacement of pressure gauge including fitting complete all as specified and directed. |
| 12 | Daily cleaning of swimming pool daily including Sunday and Holiday by providing of minimum two experienced skilled persons & one qualified service technician to perform the following duties :- (a)Cleaning of floor and side wall tiles of complete swimming pools by using brushes taking out impurities at bottom / side walls to make it bacterial growth free. (b) Cleaning of floor wall tiles with operation of suction sweepers as per standards laid down procedure for cleaning of swimming pools and manual operation of suction sweepers attached with motor-pump sets, complete cleaning by the experienced skilled persons everyday. (c)Washing the filteration plant room after cleaning with broom (on daily basis and complete pump house building including periphery of 02 Nos pressure filter, sluice valve, pipe lines, LT panel etc. (d)Cleaning of over flow water channel of swimming pool.(e)Removing dust and dirt from atmosphere due to wind effects. Leaves, foliage, plastics and other all floated metarials /insects from pool water with the help of leaf skimmer net set from pool area to outside of the pool not less than 100 mtr.(f) Maintain water quality of swimming pool by mixing chemicals as required. (g)The water in the pool is lost due to back washing, evaporation and body drips etc and it is must to make up for lost water in the balancing tank everyday.(h)Backwashing is must on every 8 hours of filtration plant running and to be done by using the balancing tank water only. |
| 13 | Note:- (i)Cleaning shall be carried out to the entire satisfaction of Engineer-in-charge.(ii)The work shall be daily supervised byone experienced supervisor of the contractor as per Condition 25 of IAFW-2249 (General Condition of Contract). A recovery of Rs 500/- shall be made from the Contractor\"s dues, if supervisor fails to supervise the work on daily basis. (iii) Daily maintenance of swimming pool is to be carried out as per operating time schedule of swimming pool wef 9:30 AM to 3:00 PM. (iv) Surrounding areas of the pool incl plant room shall be cleaned after 3:00 PM & upto 5:30 PM. (v) Chemicals will be measured & paid separatly. (vi)If the quality of water are not maintained by the Contractor, a penal recovery of Rs 1000/- shall be made on this account. (vii)The rate quoted is inclusive of T&P such as oxygen mask, air compressor, oxygen cylinder, safety rope, brush wire mess etc and all accessories reqd for under water cleaning of slope area at deep end for diving persons.(viii)Daily chemical testing of swimming pool to be carried out by contractor rep in present of engr-in-charge. (ix) The work shall be carried out all 07 days in a week incl sunday/hoilday. (x) Contractor shall take all safety precautions and all safety tools shall be provided by the Contractor to the working staff. In case of any mishappening / casualty happens to men etc, no claim whatsoever in this respect will be admissible, the entire responsibility shall be of the Contractor and no compensation will be entertained in this regard by the department. Diving person\"s life insurance and any emergencies like insurance, compensation etc shall be liability of the Contractor. Cost of the same shall be deemed to be included in the rates quoted by the contractor. (xi) Any damage occurred to the assets during cleaning shall be made good by the contractor at his own cost. (xii)The contractor shall be responsible for making good the damages occurred due to negligence in workmanship during cleaning of chamber/tank. The decision of the Accepting Officer shall be final and binding with regard to a particular defects /damages / breakage of existing equipments / lines / structures etc during cleaning which may be caused due to contractor’s people. |
| 14 | Labour and T&P to attendelectric complaints by skilled elctrician of non functional control panel, starter, motor, MCCB, identifying & rectify the electirc fault, tightening the electric loose connections, cable connections to make the plant functional complete all as specified and directed. |
| 15 | Supply and mixchlorinated isocyanurates grade TCCA-90 (Trichloroisocyanurates acid)each drum 45 kgin shape of white granular / tablet for disinfectant for swimming pool a NA sulphate of super quality contains chlorine more than 90 % duly tested from approved laboratory. Packed in a fiber drum duly sealed from authorised dealer all as specified and directed. |
| 16 | Supply and mix Sodium Hypochlorite each drum of 45 Kg having chlorine content 10% to 20 % free flowing granular material and easily soluble in water. The material should not contain more than 5% to 10% moisture.Maximum of 10% mesh passing through - 100 BSS and stability loss should be within 10% as per IS. |
| 17 | Supply and Pouring Non Ferric alum type crystal, white appearance superior grade after making in liquid form to dosing plant. |
| 18 | Supply and mix bleaching powder of approved quality, ISI marked. |
| 19 | Supply and mix copper sulphate grade-I in crytal form, deep blue colour, easily soluble in water of approved quality as per IS. |
| 20 | Supply and mix muriatic acid ofapproved quality as per IS. |
| 21 | Supply and mix baking soda of approved quality as per IS. |
| 22 | Supply and mix sodium by sulphate /dry acid approved quality as per IS. |
| 23 | Supply only crystal bright & spa clarifier and conditioned in blue colour completely soluble in water used as flocculant for co-ogulating the small particles such as fine dust, oils, micro organism contaminants in pool water to make the pool water crystal clean all as specified and directed as per IS |
| 24 | Supply only CALCIUM HYPO CHLORITE65% to 70% (Calcium based granular disinfectant for water treatment more stable than chlorine gas and stronger than bleaching powder and Sodium Hypochlorite)packed in 45 Kg Plastic drums and contain complete all as specified and directed. Note: (i) Make of CALCIUM HYPO CHLORITE granules shall be as approved by Engr-in-Charge. |
| 25 | Supply and mix calcium hardness increser of approved qualityas per IS. |
| 26 | Supply and mix sodium carbonate/Soda ash approved quality as per IS.Note :- for item Nos 10 to 21 :The Contractor shall submit purchase vouchers, test certificates, batch No, Lot No and its expiry date etc and other relevant documents alongwith supply of above chemicals. Engr-in-Charge shall verified the authenticity and genuiness of PVs and TCs before forwarding contractor\"s claim of payment. Supply of chemical shall not be accepted without production of these documents and no payments shall be made. |
| 27 | Supply only rubber/ PVC hand gloves to handle chlorine gas/ liquid all as specified and directed by Engr- In- charge. |
| 28 | Supply only pH and chlorine testing kit suitable for testing with O-Tolidine solution for regular test including solution,complete all as specified and directed by the Engineer-in-Charge. |
| 29 | Supply only OT solution for chlorine test in 500 ML bottle complete all as specified and as directed. |
| 30 | Supply only hardness test solution in 500 ML each complete all as specified and as directed. |
| 31 | Testing of swimming pool and submission of detailed test report to Engineer-in-Charge. (i) Carrying out minimum essential testing of water as per IS 3328:1993 mandatory for chemical colour, odour, taste, turbidity, PH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and bacteriological total coliform organisms per 100 ml (MPN) & E Coli in 100ml) with specific recommendation regarding suitability of water for swimming purposes. (ii) Collection of water from different sources of water ie. diving pool, balance chamber well & olymic size swimming pool in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification. Note :- Rate quoted shall also deemed to be included for the followings:-(i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source swimming pool. |
| 32 | Supply only Alkalinity test kit(5-500 Mgll) - 1100 (pool range - 80-120 PPM) with liquid reagent, Range 0-20PPM. complete all as specified and as directed. |
| 33 | Supply and replace nylon brushes for suction sweeper as per existing size and make complete all as directed. |
| 34 | S&F with a trolly mounted for motor & pool vacuum cleaner including brush for cleaning of floor of swimming pool convinent for landscape pool of superior quality enclosed in stainless steel enclosure of 36 inches in length, having 40 mm dia bore NRV & eight wheels and provision Connection with suction sweeper hose and rope tie rings at both end of brush for manual operation with rope to remove coagulated sediments from pool and two movable hinges for lifting the assembly during operation complete all as specified and as directed. |
| 35 | S&F wheels for suction sweeper assembly as per existing wheels. |
| 36 | S&F wheel CI stand, with nut, bolt, washer etc for suction sweeper assembly as per existing. |
| 37 | Supply and commissioning of Clorinax swimming pool chlorine dispenser fits 3\" chlorine tablets for swimming pool complete all as directed. |
| 38 | Repair of suction sweeper/ mono block pump of capacity upto 5 HP for the following :- |
| 39 | M&L transportation & dismanteling of suction sweeper/ mono block pump of capacity upto 5 HP, 1/3 phase, 230/415 volts AC supply after disconnecting electric connection, dismentling of pump and motor, repairing/ replacing defective parts as ordered, reassembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same reconnect to pipe line and power mains after repairs. |
| 40 | Complete oiling and greasing as required. |
| 41 | S&F terminal box including connectors of copper, plate of motor. |
| 42 | S&F ball bearing as per existing. |
| 43 | S&F stainless steel pump shaft. |
| 44 | S&F gun metal impeller with neck key, distance bush. |
| 45 | S&F coupling with cover as per existing. |
| 46 | S&F fan blade as per existing. |
| 47 | S&F base stand for motor with new nut, bolt & washers as per existing |
| 48 | Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc. |
| 49 | Preparation of old paintedsteel surface of pump and motor and applying two coats of synthetic enameled paint after applying one coat of red oxide primer. |
| 50 | Following repairs of centrifugal pump of capacity upto 20 HP :- |
| 51 | M&L transportation &dismanteling of centrifugal pump ofcapacity upto 20 HP, 3 phase, 230/415 volts AC supply,after disconnecting electric connection, dismentling of pump and motor,repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers complete and reconnecting the same reconnect to pipe line and power mains after repairs. |
| 52 | Complete oiling and greasing as required |
| 53 | S&F terminal box including connectors of copper, plate of motor. |
| 54 | S&F ball bearing as per existing. |
| 55 | S&F stainless steel pump shaft. |
| 56 | S&F gun metal impeller with neck key, distance bush. |
| 57 | S&F fan blade as per existing. |
| 58 | S&F base stand for motor with new nut, bolt & washers as per existing. |
| 59 | Cutting of burnt winding and rewinding the stator with super enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc. |
| 60 | S&F of wire mesh strainer duly fitted with MS frame on peripheral of mesh, upto size 0.6 Sq mtr in the flow of water channel completeall as specified and as directed. |
| 61 | Supply only plastic bucket, heavy duty, capacity 25 ltr as directed by Engineer-in-Charge. |
| 62 | S&F in repairs/replacementswimming pool skimmer net set that includes 1 PCs deep leaf skimmer net,1 Pcs leaf rake with mesh netand 1 pcs aluminium telescopic pole cleaning tool complete all as specified and direted swimming pool leaf net pool cleaning tool with 1.5 mtr pole as directed by Engineer-in-Charge. |
| 63 | Supply and laying rubber mat of dimensions 2mtr x 1mtr x 10mm as perISI mark for 11KV. |
| 64 | Supply only hardness test kit with liquid reagent. |
| 65 | M&L painting of GI/CI/DI pipe with existing colours all as per specified and directed by the Engr-in-Charge. |
| 66 | Supply and replace DOL starter for upto 10 HP, 1/3 phase, 230/415 volts AC supply motor. |
| 67 | S&F in repair of fully automatic star delta starter comprising of combo volt and ammeter single phase preventor, over load relay and timer housed in MS sheet power coated enclosure suitable for operating 20HP centrifugal pump set complete all as specified and directed. |
| 68 | Supply only digital chlorine test kit with LCD complete all as directed. |
| 69 | M&L providing PVC flat copper conductor cable 10 Sqmm 3 core multi stranded connected with suitable for pumps and required copper thimbles and nut bolts to panels including taking out the existing unserviceable cable complete all as specified and as directed. |
| 70 | S&F copper cable multistranded conductor unarmoured 6 Sqmm 3 core 1100V grade PVC insulated sheathed along with proper lugs complete all as specified and directed. |
| 71 | Supply only digital TDS meter complete all as directed. |
| 72 | Supply only pH meter digital LCD type with Range 0-14 PPM. Completed all as directed. |
| 73 | S&F in replacement MCB TPN 32 Amp capacity complete all as specified and directed. |
| 74 | S&F in replacement MCB TPN 63 Amp capacity complete all as specified and directed. |
| 75 | S&F in replacement, MCCB 100 Amp, 4 pole, 25 KA, breaking capacity complete all as specified and directed. |
| 76 | S&F in replacement, MCCB 160 Amp, 4 pole,25 KA, breaking capacity in sheet metal enclosure box complete all as specified and directed. |
| 77 | S&F in replacement of flanged end Non return valve/ foot valve with by pass arrangement pressure rating PN 1.6 of size \"10 Dia\" (300 mm). |
| 78 | Taking out sluice valves refacing, regrinding and refixing including replacement ofspindle, check nut complete assembly and make serviceable of following size :- |
| 79 | 80 mm |
| 80 | 100 mm |
| 81 | 150 mm |
| 82 | Repacking stuffing box of sluice valve spindle including taking apart and reassembling of following size:- |
| 83 | 80 mm |
| 84 | 100 mm |
| 85 | 150 mm |
| 86 | Maintaninence and repair to leakage/blockage of water supply GI/MS/CI/DI pipe line of 25mm to 80mm dia including necessary excavation required for taking out, burning out lead joint or damaged rubber ring/ ring /hole from position andmake the disturbed surfaces as per existing surface after replacing new spun yarn and lead joint or tyton joint of necessary fitting required as per site including welding work and making the pipe line leak proof complete all as directed. Note : Excavation rate and earth work will be included in the quoted rates. |
| 87 | Maintaninence and repair to leakage / blockage of water supply GI/MS/CI/DI pipe line of 100mm to 300 mm dia including necessary excavation required for taking out , burning out lead joint or damaged rubber ring/ ring /hole from position andmake the disturbed surfaces as per existing surface after replacing new spun yarn and lead joint or tyton joint of necessary fitting required as per site, including welding work and making the pipe line leak proof complete all as directed. Note : Excavation rate and earth work will be included in the quoted rates. |
| 88 | S&F sluice valve ISI markedPN 1.6 complete with both ends for iron pipe including necessary earth work and also taking up or down unserviceable valve of following size:- |
| 89 | 300mm bore |
| 90 | 150mm bore |
| 91 | 100mm bore |
| 92 | 80mm bore |
| 93 | S&F gate valve ISI marked ,complete with both ends for iron pipe including necessary earth work and also taking up or down unserviceable valveof following size:- |
| 94 | 50mm bore |
| 95 | 25mm bore |
| 96 | M&L replacement of old green hose pipe with new with clamp if necessary of following sizes:- |
| 97 | 50mm pipe |
| 98 | 80mm pipe |
| 99 | S&F in repair nylon rope 10mm dia twisted of superior quality completed all as directed. |
| 100 | Supply only pH test solution BTB or phenol Red solution for pH test (500ml) complete all as specified and as directed. |
| 101 | M&L replacement of black HDPE pipe with new with clamp of 2 inch diameter size. |
| 102 | Supply only nylonMarine rope of 20mm dia as directed by the Engr-in-Charge. |
| 103 | S&F electronic driver AC to DC converter duly enclosed in sheet enclosure with switch and supply in & out cable connection points including ammeter, voltmeter and indictaion lamp duly fixed in enclosure, used for under water lights (18 Nos) each stabilizer carring load of 6 light and variable light functioning, including transformer of suitable capacity as per existing on site, PCB board, indication lamp complete all as specified and as directed. Note : Change switch etc are deemed to be included in quoted rate. |
| 104 | S&F under water RGBW diodes-Dmx under water LED light DC supply typ, as per on site and making complete system water proof by selant and rubber washers and necessary wiring work with an alumiminum alloy die-cast shell,stainless steel front cover andtempered glass cover with completewiring system with fountain control panel complete all as specified and as directed.Note: Necessary arrangment like mapower, electrician, T&P, dewatering pump etc is deemed to be included in quoted rate. |
| 105 | Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth or n exc 10 sqm on planfor foundation of poles etc or for laying of cables, pipes etc and getting out in soft/loose soil complete all as specified. |
| 106 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil. |
| 107 | Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified. |
| 108 | Supply and laying fly ash brick (as per IS-13757, 1993) burnt clay fly ash building bricks, old size, with width equal to the length of the brick laid dry and flat abutted with each other with gap between adjacent brick not exc 10mm over UG cable for protection complete all as specified & directed. |
| 109 | M&L sand cushioning to PVC underground cable with screened and washed sand and punning to provide a required cover complete all as specified. Note: For all purpose of payment only punned thickness will be measured. |
| 110 | M&L galvanized iron tubing, 40mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of electric cable complete all as specified and directed. |
| 111 | Supply, laying jointing, testing & commisioning cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 1100 volts grade, of 95 Sqmm 3.5 core laid in treches /duct/passing through pipe /fixed to pole complete all as specified and directed. |
| 112 | M&L construction of brick masonry valve pit of existing size as directed including excavation and earth work in any type of soil, PCC in foundation, coping, plastering, mild steel sheet cover 2 mm thick with locking arrangement, 80mm dia lock with 03 keys, painted with two coats of bituminous paint etc with and including dismantling of existing valve pit all as specified & directed. |
| 113 | M & L for 50 mm bore GI medium grade column pipe in 6 m length with flangedjoints duly scewed and welded with pipe suspended in deep well complete with slote for lead, GI flanges, rubber gaskat clamps, bolts, nuts,etc all as required for completion of work. |
| 114 | Supply, laying, jointing/connecting and testing for 80 mm bore steel tubing galvanised medium grade pipe with all fittings, laid in trenches, complete all as specified. |
| 115 | S&F, non return valve cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc. complete ISI marked of size 80 mm bore for submersible pump as specified as directed. |
| 116 | Supply & laying in treches or passing through pipe/fixed to pole/wall PVC insulated and PVC sheathed armoured heavy duty electrical cable with multistranded aluminium conductor 1100 volts grade 25 Sqmm 3.5 core |
| 117 | S&F, analog water flow metercast iron body flanged ends & drilled horizontal heavy duty including jointing material etc. complete ISI marked of size 80 mm bore for submersible pump as specified as directed. |
| 118 | M&L for renewal of Earthing complete with GI earth plate electrode of xize 600x600x6mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level) with top edge of the plate not less than 2.95 mtr deeep below normal gound connected to and included GI earth strip 32mmx6mm by means of bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg, crystal salt 200 kg magnisium sulphate of 100 kg and vegitable soil all aroiund the plate upto 350mm above from top edge of plate and balance portion filling with excaviated soil in layers not exc 25mm thick 25mm bore galvansied iron medium grade watering pipe upto top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil PCC 1:3:6 type C1 for chamber of internal size 300mm x 300mm x 300mm with 120mm thick wall and 700mm x 700mm x 150mm thick bed concreet RCC 1:2:4 type b1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric orxPM jali (weight not less than 4.00 kg/sqmm), funnel with wire mesh complete all as specified and directed. Note (i) Quoted rate shall be deemed to include for earth strip with protectino pipe upto 7.5 length. |
| 119 | M&L jointing and testing of all kind for of DI (Ductile Iron) pipe, round flanged end on both sides of 100mm dia, K-7 complete with rubber gasket nuts, bolts washers inside OPC coated, white painted inside and black painted on out side including all kind of fittings as required and taking down old unsv pipe complete all as specified and as directed by Engr-in-Charge. |
| 120 | Design fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 phase 4 wire system outdoor type front and back opening type, separate comnpartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out inoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricate out of 3.15mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colourbuilt in industrial type locking arrangement on front and back and pre wired with PVCinsulated multi stranded copper conductor for controls and monitors PVC sleeved copper strip busbas for connecting MCCBs panelmounted on Anle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 45 CM below ground level and 15 CM above grounded level and including dismentlingh of old unsv LTpanel and consisting the following:-(a) Incoming:- (i) MCCB 4 pole TPN, 200 Amps, 36 KA breaking capacity, 415V adjustable thermal & fixed magnetic setting. Make Havells/L&T/ABB - 01 Nos(ii) Copper Bus Bar chamber 4 pole 300 Amp - 1Set(iii) Digital Amp meter 0-250Amp with CT-1Set(iv) Digital volt meter 0-500V-1 Nos(b) Outgoing (i) MCCB 4 Pole 100 Amps Capacity, 36 KVA - 02 No(ii) MCCB 4 Pole 63Amps capacity 36 KA - 01 NosNote : Spaces of out going MCCB 1 Nos to be provide and panel mounted on 2\" Height PCC platform. |
| 121 | S&F Lithium based Energy Efficient Integrated solar street light of 40 watt in single aluminium extruded body with duly polyurethane coating, encases with monocrystalline solar PV panel of 60 Wp, lithium battery 11.1/12/8 v 30AH with inbuilt BMS IP 65 high brightness W-LED (150 lm/watt) lamp with aluminium reflector for better light distribution CRI>70 colour temperature 5700-6500K microcontroller based charge controller cum driver automatic diming function PIR motion sensor with diffrential dimming function dusk to dawn operation suitable to working temperature 10 to 55 C weight not more than 14-16 Kg with adjustable MS clamp suitable for pole wall mounting etc complete as required protection short circuit overload reverse polanty and battery protection firm should provide vital parameter test report from NABL accredited lab and should be made in India with CE and ROHS complaint including dismentling of old UNSV light and including bracket of 40 mm dia medium grade all as specified and directed by Engr-in-charge. |
| 122 | M&L for galvanised steel water tubing medium grade of 50mm bore with & including fittings complete laid in trenches incl taking down old UNSV pipe. Note :- Excavation & earthwork shall be measured & paid for separately. |