| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-05-2025 | Corrigendum for Revised BOQ | BOQ | 05-06-2025 |
| 2 | 22-05-2025 | Amdt of bid submission start, end and opening date | Date | 05-06-2025 |
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep for taking out/ laying of under ground cable, pole, pipe, stay and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed. |
| 2 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as specified and directed. |
| 3 | M&L for heat shrinkable straight through joints suitable for LT PVC / XLPE insulated armoured aluminium conductor cable of size 10 sqmm to 50 sqmm, 2/3.5/ 4 core with jointing accessories including cutting of faulty cable complete all as specified and directed.Note: (i) Cutting of faulty cable/ joint is deemed to be included in the above quoted rates.(ii)If old burnt/ damaged LT cable/joint retrieved will be issued to contractor as schedule of credit.(iii)Excavation and returning/filling required for straight through joints will be included in the quoted rate. If the excavation required more than 15 RM for joint of cable than it will be measured in respective item. |
| 4 | All as per item No. 3.00 above but cable of size 70 to 120 Sqmm |
| 5 | All as per item No. 3.00 above but cable of size 150 to 185 Sqmm |
| 6 | S&F in repair 6 Sqmm twin core cable flat or circular stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed. |
| 7 | S&F in repair 10 Sqmm twin core cable flat or circular stranded conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed. |
| 8 | S& F in replacement of MCCB, TPN 63/100 Amps, 50kA breaking capacity with overload and thermal tripping features, 415 volts, AC, 50 Hz complete with suitable spreader complete all as specified and directed. Note: Minor addition and alteration and requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate |
| 9 | S&F in replacement of MCB TP 25-63Amps , 415Volts, 10 kA, C curve type complete all as specified and directed. |
| 10 | S&F in replacement of MCB TPN 40-100Amps , 415Volts, 10 kA, C curve type complete all as specified and directed. |
| 11 | S&F in replacement of on load changeover switch four pole of 63Amps., 415 volts, 50 Hz, open execution type complete all as specified and directed.Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates. |
| 12 | S&F in replacement of on load changeover switch four pole of 100Amps, 415 volts, 50 Hz, open execution type complete all as specified and directed. Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates. |
| 13 | Supplying and laying in replacement of synthetic rubber insulated mats 2.5 mm thick for voltage 11 KV for electrical purpose as per IS 15652-2006, (superseeding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. |
| 14 | M&L for painting of erected steel tubular swaged poles of LT over head line (except embedded portion), 8.5/9 Mtrs long complete including all MS work mounted on pole, earth protection & water pipe (if exists) by necessary preparation, cleaning including scrapping up of old corroded paint dirt/ dust/ rust carefully and applying two coat of aluminium paint and providing 07 Nos bands/ straps with synthetic enamel paint (any tint 30 cm wide each)from top of plinth block and writing of pole number with white synthetic enamel paint on black ground complete all as specified and directed. |
| 15 | M&L for painting of erected steel tubular pipe of size 80mm dai in form of poles including 40mm dia GI pipe for the cable potection complete including all MS work mounted on pole, earth protection & necessary preparation, cleaning including scrapping up of old corroded paint dirt/ dust/ rust carefully and applying two coat of aluminium paint and writing of pole number with white synthetic enamel paint on black ground complete all as specified and directed. |
| 16 | M&L for earthingwith copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip of size 20 x 3 mm as earthing leadmeans of nut, bolts and washers made out of Brass and 40 mm dia GI pipe \"light grade\" for protection of earth lead and connected to control board or main switch or as directed by Engr -in-Charge including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels, wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and tesing complete all as specified and directed.Note : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed in AF Station.(ii) If the desired earth registance is not achived during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable. |
| 17 | M&L for earthingwith galvanised earth plate electrode 600 mm x 600 mm x 6.30 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 25 mm x 4 mm thick, by means of nut, bolts and washers made out of galvanised iron mild steel and 50 mm dia GI pipe \"light grade\" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 mm x 300 mm x 100 mm thick, with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels, wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete all as specified and as directed. Note : The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed in AF Station. |
| 18 | S&F in replacement of galvanised iron strip 32mm x 6mm with fixing screws for conductors/ earth lead including welding and nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface complete all as specified and directed. |
| 19 | S&F in repair of busbar chamber box AC 415 V, 50 Hz, 3 Phase, wall mounting type structure of minimum size 0.5mx0.4mx0.10m with bottom cable entry with suitable cable glands structure made out of 2.0 mm thick CRCA steel sheet including 4 Nos aluminium bus bar 200 Amps supported on non hygroscopic fibres and brass screws having 4 Nos hole on each busbar with nuts, bolts & washers and suitable mounting arrangement for bus bars having sloping canopy at top with suitable locking arrangement duly powder coated finished complete all as specified and directed. |
| 20 | M&L for repairs/ replacementof Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 21 | S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steek sheet 0.50 mm thick of Red colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixes with self tapping screws complete all as specified and directed. |
| 22 | M&L for preparation of old painted steel or iron surfaces of LT Panel of size 600mm x 600mm x 900mm of any description by cleaning with scrapers and emrey paper, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enameled spray painting of approved shade complete all as specified and directed.Note:- Contractor will apply one layer of greese over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates. |
| 23 | M&L for repair/ maintenance of LT panel door by replacement of hinges and locking arrangement including necessary welding/ nuts, bolts, washers as per existing size/ type complete all as specified and directed.Note: One side door will be measured & paid as one job. |
| 24 | Dismantling of old U/S LT feeder pillar box/LT junction box including PCC/Brick wks foundation after disconnecting of all elecrical connection complete all as specified and directed. |
| 25 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory madewater and vermin proof protection pedestal type feeder pilar box of minimum size 1100 mm x 800 mm x 400 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provisio of cable looping box of size 700 x 450 x 400 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be omplete painted with Powder Coated paint of approved shade. \"U\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - |
| 26 | Contd/ -- -- --Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement.(a)Copper busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (Incomming)(b)Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going)(c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 160 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (d) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links . ( Outgoing -04 Nos) (e) MCB SPN 40 Amps 240 volts 10 KA - 4 Nos (Make :- L&T/ C&S /Legrand).(f)Neon indicator lamp with holder (RYB) = 03 Nos (L&T/Legrand/ C&S).(g) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (Make :- LEGRAND/L&T/ C&S).(h) Digital Ammeter of range (0-200) Amp flush mounting type with selector switch = 01 No (Make :- LEGRAND/L&T/ C&S).(j) Enameled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No. |
| 27 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory made water and vermin proof protection pedestal type feeder pilar box of minimum size 1100 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provisio of cable looping box of size 700 x 450 x 400 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be omplete painted with Powder Coated paint of approved shade. \"U\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - |
| 28 | Contd/ -- -- --Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement.(a)Copper busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (Incomming)(b)Copperbusbar 400 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going)(c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 250 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (d) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 100 amps including all fixing accessories with both ends spreader links . ( Outgoing -02 Nos) (e) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links . ( Outgoing -01 Nos) (f) MCB SPN 40 Amps 240 volts 10 KA - 4 Nos (Make :- L&T/ C&S /Legrand).(g)Neon indicator lamp with holder (RYB) = 03 Nos (L&T/Legrand/ C&S).(h) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (Make :- LEGRAND/L&T/ C&S).(j) Digital Ammeter of range (0-200) Amp flush mounting type with selector switch = 01 No (Make :- LEGRAND/L&T/ C&S).(k) Enameled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No. |
| 29 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Appoved,water and vermin proof protection pedestal type feeder pilar box of minimum size 1100 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be complete painted with Powder Coated paint of approved shade. \"U\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - |
| 30 | Contd/ -- -- --Note :(i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement.(a) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 200 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (b)Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going)(c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 100 amps including all fixing accessories with both ends spreader links . ( Outgoing -02Nos) (d) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links . ( Outgoing -01 Nos) (e) MCB SPN 40 Amps 240 volts 10 KA - 4 Nos (f)Neon indicator lamp with holder (RYB) = 03 Nos (g) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (h) Digital Ammeter of range (0-300) Amp flush mounting type with selector switch = 01 No (j) Enameled Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No. |
| 31 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Appoved,water and vermin proof protection pedestal type feeder pilar box of minimum size 1300 mm x 1000 mm x 500 mm (overall) of indoor type made out of 3.15 mm thick CRCA sheet with framewith singal door, front and back side openable hinged door and air ventilation . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be complete painted with Powder Coated paint of approved shade. \"U\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2as in foundation and finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - |
| 32 | Contd/ -- -- --Note :(i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement.(a) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 400 amps including all fixing accessories with both ends spreader links. ( Incomming -01 Nos) (b)Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going)(c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 250 amps including all fixing accessories with both ends spreader links. ( Incomming -02Nos) (d) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 160 amps including all fixing accessories with both ends spreader links. ( Incomming -01 Nos) (e) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links. ( Outgoing -01 Nos)(f)Neon indicator lamp with holder (RYB) = 03 Nos(g) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No(h) Digital Ammeter of range (0-400) Amp flush mounting type with selector switch = 01 No (j) Enameled Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No. |
| 33 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Appoved,water and vermin proof protection pedestal type feeder pilar box of minimum size 1100 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be complete painted with Powder Coated paint of approved shade. \"U\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : |
| 34 | Contd/ -- -- --Note :(i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement.(a) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 250 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (b)Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos ( Out going)(c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 160 amps including all fixing accessories with both ends spreader links . ( Incomming -01Nos) (d) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 100 amps including all fixing accessories with both ends spreader links . ( Incomming -02 Nos) (e) MCCB 4 pole, 415 volts, 25 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 63 amps including all fixing accessories with both ends spreader links . ( Outgoing -01 Nos) (f)Neon indicator lamp with holder (RYB) = 03 Nos (g) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (h) Digital Ammeter of range (0-300) Amp flush mounting type with selector switch = 01 No (j) Enameled Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No. |
| 35 | Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, factory madewater and vermin proof protection pedestal type feeder pilar box of minimum size 1100 mm x 800 mm x 500 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement. Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be complete painted with Powder Coated paint of approved shade. \"U\" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus barand should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size \"F\" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x .8 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - |
| 36 | Contd/ -- -- --Note :(i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement.(a) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 400 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (b) Outgoing Copperbusbar 400 Amps capacity including insulator with nuts & bolts-04 Nos(c) Enameled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No.(d)Neon indicator lamp with holder (RYB) = 03 Nos (e) Digital Voltmeter of range (0-500) volt flush mounting type with selector switch = 01 No (f) Digital Ammeter of range (0-400) Amp flush mounting type with selector switch = 01 No |
| 37 | Supply, install, testing and commissioning of LT indoor Feeder Pillar Box AC 415 V, 50 Hz, 3 Phase, 4 wire, totally enclosed self supporting structure/ cubicle, fully compartmentalized type, weather proof, protection IP 54 of minimum size 1200mmx1400mmx500mm, double door type, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick outer & 2.0 mm thick inner CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover and MCCBs with sloping canopy at top, double hinged doors at front with suitable locking arrangement including louvers at sides duly powder coated complete for accomodating & including following accessories:-DETAILS:-INCOMER: (i) MCCB 4 pole, 415 Volts with breaking capacity35 kA of 250 Amps with fixed thermal and fixed magnetic setting- 01 NosOUTGOING:(i) On Load Changeover open type 4 pole of capacity 250 Amps, 415 Volts, 50Hz - 01 Nos(ii) MCCB 4 Pole ,415 Volts with breaking capacity18 kA of capacity 160 Amps with thermal magnetic release -02 Nos(iii) MCCB 4 Pole ,415 Volts with breaking capacity18 kA of capacity 100 Amps with thermal magnetic release -02 Nos (iv) MCCB 4 Pole ,415 Volts with breaking capacity18 kA of capacity 63 Amps with thermal magnetic release -02 Nos BUSBAR:(i) Copper bus bar 400 Amps supported on non hygroscopic fibres and brass screws with nuts, bolts & washers - 04 NosINDICATING DEVICES:(i) LED Indicating lamps for main supply indicating R, Y, B - 03 Nos.(ii)Digital ampere meter of 0-250 A, 3 phase, class 1 , including CT having CTR 250/5 - 01 No(iii)Digital voltmeter 0-500 Volts, 3 phase, class 1, - 01 No |
| 38 | Supply, fabrication, installation and testing of LT out door type factory made, junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed.(a)Copperbus bar of size 600 Amp wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 nos.(b)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 39 | Disconnecting electric connection and Taking down of all UG cable from LT Panel/JB/Bldg DB of any capacity and model removing of unserviceable spares / accessories for repair/replacement of the same including reconnection of all UG Cable connection with suitable lugs ,nuts & bolts etc to existing LT Panel/JB and testing complete all as specified and directed. The unit Rate shall be deemed to be included for the following nature of work:(i) Contractor shall provide one Electrician and one helper along with tools. (ii)Major Spares/Parts like MCCB,MCB,Ammeter,Voltmeter & indicator lamp for reapir will be measured and paid saperatly as supply only under relevent item of this schedule. |
| 40 | M &L for Repair and maintenance of APFC Capacitor bank Panel board upto 125 KVAR with 5/6 stage by chechking fault, weakness of capacitor and removing of fault including replacement of spare items complete including testing for proper automatic functioning complete all as specified and directed.Note : Spare items required for repair / maint shall be measured seperately under respective items. |
| 41 | M&L for complete rewiring of APFC panel of up to capacity 125 KVAR by taking out burnt inter connection wiring including u/s and serviceable components for reuse and rewiring of panel using existing size of copper cable, ferrule, lugs, insulating material, nut, bolt, washer of various sizes, refixing serviceable items with auxiliary coil and testing complete for proper functioning complete all as specified and directed. |
| 42 | S&F in replacement of rectangular/ cylindrical heavy duty capacitor 3 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed.Make : EPCOS/ L &T/ SIEMENS/ HAVELLS |
| 43 | S&F in replacement of rectangular/ cylindricalheavy duty capacitor 5 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed.Make : EPCOS/ L &T/ SIEMENS/ HAVELLS |
| 44 | S&F in replacement of rectangular/ cylindricalheavy duty capacitor 10 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed.Make : EPCOS/ L &T/ SIEMENS/ HAVELLS |
| 45 | S&F in replacement of rectangular/ cylindricalheavy duty capacitor 20 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed.Make : EPCOS/ L &T/ SIEMENS/ HAVELLS |
| 46 | S&F in replacement of rectangular/ cylindricalheavy duty capacitor 25 KVAR, 3 phase , 440 volts, 50 Hz complete all as specified and directed.Make : EPCOS/ L &T/ SIEMENS/ HAVELLS |
| 47 | S&F in replacement of power factor controller 30-525 Volts (mean Volatge), 230 Volts (supply voltage), 50 Hz, 6 steps, 3 phase complete all as specified and directed. Make : EPCOS/ L &T/ SIEMENS/ HAVELLS |
| 48 | S & F in replacement of contactor 3 pole, 415 Volts, 50 Hz, 25KW, minimum 50 Amps complete all as specified and directed.Make : EPCOS/ L &T/ SIEMENS/ HAVELLS |
| 49 | S & F in replacement of Push switch for Manual ON/OFF of capacitor panel including making all electrical connection complete all as specified and directed. |
| 50 | S&F in replacement of LED Indicator as per Colour Scheme ( Red, Yellow, Blue, Green) Suitable for APFC / LT panel complete all as specified and directed. |
| 51 | S&F in replacement of voltmeter digital type 0-500 Volts AC, flush mounting type, 3 phase, class 1 Suitable for APFC / LT panel complete all as specified and directed. |
| 52 | S&F in replacement of ammeter digital type, up to 400 Amps flush mounting type, 3 phase, class 1 with suitable CTs of range as required for APFC / LT panel complete all as specified and directed. |
| 53 | Demolition and Dismantaling of Concrete of any description and in any position not otherwise specifically provided for LtPanel / AMF Panel / APFC Panel / Isolation Transfomerfoundation complete including removal of old concrete complete all as specified and directed. |
| 54 | M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate for foundation of poles, stay etc complete all as specified and directed. |
| 55 | M&L for disconnecting of Electrical connection, earthing lead and taking out carefully defective Isolation Transformer of up to 75 KVA capacity located at AF stn Mohanbari inclusive shifting it from AF stn Mohannari to Civil workshop by using mechanically operated crane and truck and back to its original position after necessary repairs and installing the Isolation Transformer inclusive reconnection of all electrical cables wires and earthing connection complete all as specified and directed. |
| 56 | M&L for dismantling of Isolation Transfomer of capacity upto 75 KVA by disconnecting all internal electric connection after draining out of transfomer oil and storing the oil in transfomer oil barrel of cap 210 ltrs for reuse and opening the top cover of the isolation transfomer by removing nuts, bolts, washers, etc and lifting the core / winding by using indoor crane removing internal electrical connections by unscrewing nut, bolts, etc cleaning entire housing of transformers and dismantling complete primary / secondary winding from the limb and removed the entire tape insulation from the existing copper winding wire complete all as specified and directed. |
| 57 | M&L for reinsulation of Primary coil of isolation transformer by using proper size of insulation paper sheet to entire copper winding wire complete all as specified and directed. |
| 58 | M&L for reinsulation of Secondarycoil of isolation transformer by using proper size of insulation paper sheet to entire copper winding wire complete all as specified and directed. |
| 59 | S&F in repair top cover gasket sheet as per exisiting size for various capacity of isolation transfomer complete all as specified and directed. |
| 60 | M & L for dehydration & filteration of transformer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filteration to achieved 40 KV at 2.5 mm gap complete all as specified and directed.Note:(a) The filtration of the transformer oil shall be carried out at different locations of Air Force Station Mohanbari.(b) The report before filtration & after filtration to be submitted by contractor.(c) Transformer oil for topping up will be measured and paid separately. |
| 61 | Supply & toping up of new transformer oil (in sealed barrel) confirming to IS 335 Std having dielectric strength 40KV at 2.5mm gap after initial dehydration complete all as specified and directed. Make: Savita/ Castrol/ Power True/ Truoil. |
| 62 | M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of Isolationtransformer of capacity upto 75KVA complete with all connected fittings & fixturesand other standard fittings & attachments as per existing colour scheme and pattern with atleast two coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction of Engr-in-Charge complete all as specified and directed.Note:- Contractor will apply one layer of greese over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates. |
| 63 | S&F in replacement of air breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with new silica gel (blue in colour) suitable for Isolation Transfomer fixing on existing pipe of size 15/20/25 mm dia with suitable reducer/ connector complete as per site requirement complete all as specified and directed. Note:-(a)Cost of modification (if required to fix on existing MS pipe) shall be deemed to included in the item quoted rate. |
| 64 | S&F in replacement of Silica Gel dehydrated blue coloured complete all as specified and directed. |
| 65 | Comprehensive periodical servicing, repair , maint on monthly basis (minimum twice in a month) visting the site of AFS Mohanbari for smooth proper functioning of the street / flood / High bay lights / Post Top lamp / wellglass fittings/Perimeter light located at any height of pole / walls/ any locationincluding checking, dismanteling , servicing, cleaning, removing dust or dirt and repairing of fittings by replacing defective parts for the trouble free and efficient functioning and testing complete all as specified and directed. Note:(i) LED Drivers, Surge protection device, FR PVC cable for connection, GI brackets etc shall be measured and paid seperately under relevant items of this schedule.(ii) Minor parts like insulation tape, cotton waste, nuts, screw etc shall be deemed to be included in the item quoted rates. |
| 66 | Supply only 10 KV surge protection device for LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures higher capacity for fixing in repairs complete all as specified and directed. |
| 67 | Supply only 5 KV surge protection devicefor LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures for fixing in repairs complete all as specified and directed. |
| 68 | Supply only Drivers for LED street lights / well glass fitting35W to 60 W, 230 Volts, 50 HZ complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 69 | Supply only Drivers for LED Flood light fitting / High Bay light 70W/80W, 230 Volts, 50 HZ complete all as specified and directed. Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 70 | Supply only Drivers for LED street lights / Flood light fitting90W/100W, 230 Volts, 50 HZ complete all as specified and directed. Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 71 | Supply only Drivers for LED Street light fitting / High Bay light, 120W / 150 W, 230 Volts, 50 HZ complete all as specified and directed. Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 72 | Supply only Drivers for LED Flood light fitting 120W, 230 Volts, 50 HZ complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 73 | Supply only Drivers for LED Post Top Lantern 40W, 230 Volts, 50 HZ complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 74 | Supply onlyGI Bracket for mounting of Street lights made out of 40 mm GI pipe medium grade 1.5 meters in length bend in shape as required including necessary MS flat iron clamps, nuts and bolts etc complete all as specified and directed. |
| 75 | Supply only GI Bracket for mounting of Street lights made out of 25 mm GI pipe medium grade 1.5 meters in length bend in shape as required including necessary MS flat iron clamps, nuts and bolts etc complete all as specified and directed. |
| 76 | Supply only 1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 1.5 Sqmmfor electrical connections to the street lights fittings complete all as specified and directed. |
| 77 | Supply only 1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 2.5 Sqmmfor electrical connections to the street lights fittings complete all as specified and directed. |
| 78 | Supply only 1100 Volts heavy duty round sheathed multistranded Five core bright annealed bare copper conductor cable of size 2.5 Sqmmfor electrical connections to the high mast lights fittings complete all as specified and directed. |
| 79 | S&F in repair of LED street light fitting 35 / 36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, surge protection device and corrosion resistant including thermal management complete with IP 65/66 protection complete all as specified and directed. Make : Bajaj/Havells/Crompton/Philips or equivalent. |
| 80 | S&F in repair of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, surge protection device and corrosion resistant including thermal management complete with IP 65/66 protection complete all as specified and directed. Make : Bajaj/Havells/Crompton/Philips or equivalent. |
| 81 | S&F in repair of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, surge protection device and corrosion resistant including thermal management complete with IP 65/66 protection complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips or equivalent. |
| 82 | S&F in repair ofLED flood light 70 watt 230 V ACoutdoor type with thermal management with IP66 protection and corrosion resistant complete with driver, surge protection deviceand lamp complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips or equivalent. |
| 83 | S&F in repair ofLED flood light 150 watt 230 V ACoutdoor type with thermal management with IP66 protection and corrosion resistant complete with driver, surge protection deviceand lamp complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 84 | S&F in repair ofLED flood light 120 watt 230 V ACoutdoor type with thermal management with IP66 protection and corrosion resistant complete with driver, surge protection deviceand lamp complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips or equivalent. |
| 85 | S&F in repair ofLED Post Top lantern 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection and corrosion resistant complete with driver, surge protection device and lamp complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 86 | S&F in repair ofpolycarbonate globe light 12 watt, 230 volts AC, unbreakable with B-22 type holder, IP-65 protection with & including 12W, B-22 type warm white LED bulb complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 87 | M&L for repairing and rewinding of High mast motor of capacity upto 3 HP/2.4 KW of anymake/model, including removal of existing burnt windings completely and carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing guage complete including dismantling and re-assembling of starter, rotor, blades etc complete all as specified and directed. Note:- (Rate is inclusive of transportation to and fro from MES store/site to civil workshop. |
| 88 | S&F in repair of MCCBs 63/100 Amps 4 pole, 415 V breaking capacity 16 kA , thermal magnetic release including spreader terminals for easy operation and connection complete all as specified and directed. |
| 89 | S&F in repair of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single pole and capacity 10 to 32 Amp complete all as specified and directed. |
| 90 | S&Fg in repair of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single pole and neutral and capacity 10 to 32 Amp complete all as specified and directed. |
| 91 | S&F in repair of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of Triple pole and capacity 40 to 63 Amp complete all as specified and directed. |
| 92 | S&F in repair power contactor 40 Amps 3 pole ( 1 NO + 1 NC) , 415 Volts AC 50Hz,including connecting with existing system complete all as specified and directed. |
| 93 | S&F in repair of Digital Time switch(5-40) Amps , 240 Volts , AC , Singlephase complete all as specified and directed. |
| 94 | S&F in repair of LED Aviation light luminaire having die-cast aluminium housing with polycarbonate enclosure, driver and LEDs connected in series and parallel combination with better heat dissipation 240 Volts, IP -65 with all accessories complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 95 | S&F in repair ofLED round Highbay luminaire 80 watt 230 volts with high efficiency, IP 66 in PDC housing suitable for induastrial applications including prewired and corrosion resistantcomplete with driver, surge protection device and lamp complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 96 | S&F in repair ofLED round Highbay luminaire 120 watt 230 volts with high efficiency, IP 66 in PDC housing suitable for induastrial applications including prewired and corrosion resistantcomplete with driver, surge protection device and lamp complete all as specified and directed.Make : Bajaj/Havells/Crompton/Philips/Surya or equivalent. |
| 97 | M&L for cleaning the swaged steel tubural street light pole 9 / 11 meters height including GI pipe of street light fitting and prepare surfaces cleaningincluding scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coat of aluminium paint and marking of zebra crossings up to a height of 1.5m above the coping with blue andwhite strips of synthetic enamel paint including writing of pole numbers and two coats colour washing of PCC coping complete all as specified and directed. |
| 98 | Excavating in trenches, n.exc 1.5 m wide and n exc 1.5 m in depth for foundation or for trenches for laying GI pipes, cables, pole, stay used for cable protection and getting out in Hard /Dense Soil complete all as specified and directed. |
| 99 | Returning/ filling including spreading, levelling and well ramming in layers not exc 25cm in thick complete all as specified and directed. |
| 100 | M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing upto 40 mm bore complete all as specified and directed. |
| 101 | Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and directed. Note:- Only punned thickness of 18cm will be measured for the purpose of payment. |
| 102 | Supply and laying burnt brick sub class \"B\" of size 230 x115 x75mm for protection of cable, laying in trenches including taking out old complete all as specified and directed. |
| 103 | Supply and laying Pipes in repairs galvanized iron Light grade for cable protection of size 25 mm bore complete all as specified and directed. |
| 104 | Supply and laying Pipes in repairs galvanized iron Light grade for cable protection of size 40 mm bore complete all as specified and directed. |
| 105 | Taking out old serviceable/ unserviceable cable of size 2/4 core, up to 16 sqmm of any make/ type and keeping aside for the purpose of rerouting/ relaying in new location/ for requisite replacement/ further disposal complete including taking out bricks complete all as specified and directed.Note: Earth work shall be measured & paid separately. |
| 106 | M&L in repair LT UG cable of size 2 core 10 Sqmm aluminium conductor XLPE insulated and sheathed armoured , heavy duty 1100 voltsin trenches/poles/surface and connecting with all accessories complete all as specified and directed. |
| 107 | M&L in repair LT UG cable of size 4 core 16 Sqmm aluminium conductor XLPE insulated and sheathed armoured , heavy duty 1100 voltsin trenches/poles/surface and connecting with all accessories complete all as specified and directed. |
| 108 | Re-laying of serviceable (as obtained from taking out) cable of size 2/4 core up to 16 sqmm of any make/ type inclung making electrical connection complete all as specified and directed.Note: Earth work shall be measured & paid separately. |
| 109 | M&L for Straight through joint suitable for cable size 4 core 6 sqmm to 16 sqmm LT UGcable with necessary jointing materials and ferrule including cutting unserviceable portion of cable complete all as specified and directed. |
| 110 | S&F in repair of Rigid non metallic PVC conduit of dia 20 mm including of all tee, bends, elbows, reducers, and fixing such as couplers lock nuts, saddles, pipe hooks complete all as specified and directed. |
| 111 | S&F in repair of HOT moulded (FRP) SMC jucntion box for street light pole with locking arrangementt hinged door with IP -65 protection of size 205 x 255 X 112 with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and directed. |
| 112 | M&L for sub main wiring2 runs of1.5 Sqmm PVC insulated FRLS cable multistranded copper conductor 1100 V grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed on wall/ ceiling/floors for flameproof application connected upto DB and 1.5 sqmm copper earth wire for earth continuity conductor and connecting to common earth dolly including taking down old complete all as specified and directed.Note :- 3 runs of 1.5 sqmm cable and one length of MS conduit shall be measuredas one length. |
| 113 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy