| 1 | Earth work excavation and depositing on bank with in initial lead of 10 m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth,earth mixed with small sized boulders and hard gravelly soil as per SS 20B 1st depth 0 to 0.30m |
| 2 | Earth work excavation and depositing on bank with in initial lead of 10 m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth,earth mixed with small sized boulders and hard gravelly soil as per SS 20B 2 nd depth 0.30 to 0.60m |
| 3 | Earth work excavation and depositing on bank with in initial lead of 10 m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth,earth mixed with small sized boulders and hard gravelly soil as per SS 20B 3 rd depth Above 0.60m |
| 4 | Collection and supply of Sandand filling in to the basement including cost and conveyanceto the siteand all labour charges for filling as per standard specifications |
| 5 | Cement concrete 1:4:8 mix using 40mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing,laying and curing etc completefor 10 cum. |
| 6 | Supplying and fabrication of steel including cost and conveyance of bending to shape and tying in position and forming grills for all R.C.C works including cost and conveyance of all materials to site |
| 7 | Reinforced cement concrete 1:1.5:3 mix using 20mmISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying, and curing etc complete for 10 cum. Upto Basement |
| 8 | Reinforced cement concrete 1:1.5:3 mix using 20mmISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying, and curing etc complete for 10 cum.Above Basement |
| 9 | Supplying and erecting centeringshuttering includingnecessary supportsforplane surface infoundationandbasementandinallfloorsforR C Ccolumn footing column plinth beam, beams, roof slabs, staircase steps, bed blocks, criticalpier etc using mild steel sheets of size 90 x 60 cm and 10 guagestiffened, weldedwithmild steel angles ofsize25mmx25mmx3mmforboardinglaidoversilver oak(country wood) scantlings of size 10cm x 6.5cm spacedof about 90cm centretocentreand supported by casurina props of 10cm to 13cm dia spacedat 75cmcentretocentre complete complying with standardspecificationsandasdirectedbydepartmental officers including conveyance of all materials to site and proper centering etc complete.Upto Basement |
| 10 | Supplying and erecting centeringshuttering includingnecessary supportsforplane surface infoundationandbasementandinallfloorsforR C Ccolumn footing column plinth beam, beams, roof slabs, staircase steps, bed blocks, criticalpier etc using mild steel sheets of size 90 x 60 cm and 10 guagestiffened, weldedwithmild steel angles ofsize25mmx25mmx3mmforboardinglaidoversilver oak(country wood) scantlings of size 10cm x 6.5cm spacedof about 90cm centretocentreand supported by casurina props of 10cm to 13cm dia spacedat 75cmcentretocentre complete complying with standardspecificationsandasdirectedbydepartmental officers including conveyance of all materials to site and proper centering etc complete.Above Basement |
| 11 | Brick work in cement mortar 1:5 mix using country bricks 83/4\"x4 1/4\"x2 3/4\" and conveyance of all materials to site and all labour charges etc complete For 10cum Upto Basement |
| 12 | Brick work in cement mortar 1:5 mix using country bricks 83/4\"x4 1/4\"x2 3/4\" and conveyance of all materials to site and all labour charges etc complete For 10cum Above Basement |
| 13 | Filling with excavated earth with cost and conveyance including all other labour charges etc complete |
| 14 | Plastering in cm 1:3 mix of 10mm thickwith cost and conveyance including all other labour charges etc complete |
| 15 | Plastering in cm 1:5 mix of 12mm thickwith cost and conveyance including all other labour charges etc complete |
| 16 | Supplying and fixing of steel door including all other charges etc complete Door Size (1.00x2.10) |
| 17 | Supplying and fixing of steel door including all other charges etc complete Door Size (1.10x1.80) |
| 18 | Supplying and fixing of steel door including all other charges etc complete Door Size (0.75x1.80) |
| 19 | Supplying and fixing of RCC Jollyincluding all other charges etc complete |
| 20 | Providing granolothic floor finish CC 1:2:4 mix with cost and conveyance including all other labour charges etc complete |
| 21 | Supply and fixing of metal corrugated sheet of 6m thick with cost and conveyance including all other labour charges etc complete |
| 22 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. |
| 23 | Dadooing of walls with Printed design glazed tiles of size 15 cm x15cmx6mm laid in CM 1:2, 10mm thick & pointing with white cement using 0.4kg/cm2-10Sqm. |
| 24 | Supplying and Fixing of EuropeanWater closetwith \"P\" or \" S\" Trapand with ISI mark. The cost is includs of double flapped PVC seat cover, PVC pipe 110mm dia and all internal fittings and with necessary CI Brakets 12mm brass nipple 15mm dia chromium plated broiwn headwd stop cock of approved quality with ISI mark and nylon connectionincluding fixingthe sameto wall and giving nessary water supply connection to theEuropean water closet with 12.50 litscapacity porcelin low level flushing Tank with all internal fittings. The European water closetshould be fixed on the floor using counter sunk bolts and nuts and necessary teakwood plugs, clamps screws etc., including dismantling the floor or wall wherever necessary and redoing the same to their original condition etc., as per standared specification etc complete. |
| 25 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm colour glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with Sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two Sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. |
| 26 | Supplying and Fixing of Hand wash basin of size 550 x 400 mm(without pedastal)necessary cast ironbracket 15mm diachromium plated pillar tap 32mm dia \" B\" class GIwaste pipe 32mm chromium plated brass waste coupling with rubber plug and chain 15mm dia nylon connection etc.,includingfixing the wash hand basin in possition including cost of teak wood plugs screws rubber washer, white lead and giving water supply connection testing for leakage etc. completeas per standared specification etc complete |
| 27 | Distembering two coats with best approved distemberincluding cost and conveyance of all materials to site and all labour charges etc complete |
| 28 | Exterior Emulsion painting two coats with best approved quality and colourpaint over one coat of Base coat including cost and convyance of all materials to work site and labour charges etc., complete. |
| 29 | Painting two coats over New iron works using ready mixed enamel paint including cost and conveyance of paint and all labour charges etc complete |
| 30 | Wiring with 2x 1.5 sqmm (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitablePVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A F.T. switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / Fan point (For Electronic regulator) SD 16 |
| 31 | Supply and Run of 2 of 4 sq.mm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable heavy gauge M.S. coundit pipe on wall and ceiling with continous earth wire connection of 14 SWG TC wire with painting of suitable colour SD44 |
| 32 | Supply and fixing of CFL bulb etc complete |
| 33 | SupplyandfixingofTNEBmeterboardsuitablefor32Asinglephaseserviceconnectionwith32Afuseunit(500V)32Aneutrallinkandearthlink(1\"x1/8\"copperflat)onTWplankofsize375mmx300mmx19mmwithsupportingTWreepersof1\"thickaneithersidewithpaintingwithsuitableboltandnutsforfixingtheTWplankonwallwithearthconnectionandinterconnectionwith7/20PVCinsulatedcopperwirefromEBmetertofuse unit SD 125 |
| 34 | Supply and fixing of PVCScrew Down Tap 15 / 12mmdia (Heavy Type) etc complete |
| 35 | Supply and fixing of 20mm dia pvc pipe 10gk / M2 etc complete |
| 36 | Supply and fixing of 25mm dia pvc pipe 10gk / M2 etc complete |
| 37 | Supply and fixing of 500 ltrs syntex tank etc complete |
| 38 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package} |