Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 2 | Excavation for foundation in Hard murum including removing the excavated material upto a distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringand struttingetc. complete. (Lift from1.5 to3.0m.) By Mechanical Means |
| 3 | Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed bychisellingwherenecessaryandremovingtheexcavatedmaterialandstackingitin measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramming etc. complete. (Lift from 1.5m To 3.0 m) By Mechanical Means |
| 4 | Excavation for foundation in Soft rock and old cement or lime masonry foundations, paver blocks including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m)By Mechanical Means |
| 5 | Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.Layers including watering and compacting etc. complete. |
| 6 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionetc. complete. |
| 7 | Providingsoling using80mm sizetrapmetalin15cm.layerincludingfilling voidswith Crushed sand/grit, ramming, watering etc. complete. |
| 8 | Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting,rougheningthemifspecialfinishistobeprovided,finishingunevenand honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered bygunnybag,plastic,tarpaulinetc.(Woodencenteringwillnotbeallowed.),withfully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/concreteBatchmixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade) |
| 9 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) for Foundations |
| 10 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) for Grade slab |
| 11 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete in M- 25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 13 | Providing and laying Cast in situ/Ready Mix cement concrete M-25of trap/ granite / quartzite/ gneiss metal for R.C.C.slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 14 | Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC without SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 15 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 16 | Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 17 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:3without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. |
| 18 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. |
| 19 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingoutgrainsandcuringforfourteendays scaffolding etc.complete. |
| 20 | Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. |
| 21 | Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper andwipe clean wall primer with brush withmineralturpentinewithbrush8to10%andoil15to20%withrollerand allowingtodryforaperiod6to8hours.wallputtywithappropriateproportionofwater allowing to dry forperiod4to 6hours.Scrapping withEmerypaper180andwipe clean. Applyingwall primer withbrushwithmineral turpentine 8 to 10% andoil 15 to 20% with rollerScrappingEmerypaper320andwipeclean,interiorwallfinishluster1stcoatwith brush/rubber/spraywithmineralturpentine 7to 9%andOilwithroller19 to 21% After8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9% withbrushandOil withroller 19 to 21% after allowing dry for the period of 6 to 8 hours activity.(With prior approval of S.E.) |
| 22 | Scrapping the oldplasteredinternalsurface withsandpaperandcoatingthe entiresurface with mixture of whiting or glue and linseed oil including scaffolding etc. complete as directed. |
| 23 | Providing and applying white-wash in one coat on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming downetc. complete. |
| 24 | Providingandapplyingcolour-washofapprovedcolourandshadeintwocoatstonew surfaceincludingscaffolding,brushingandbroomingdown(excludingbasecoatofwhite- wash) etc. complete. |
| 25 | Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete |
| 26 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixedwithapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldatthejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofnessonCourtfeestamppaperofRs.500/- including ponding test etc. complete. |
| 27 | Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two trackswithrectangularpipe having overalldimension63.50x38.10x1.02mm atweight 0.547 Kilogram/One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight0.695Kilogram/One Running Metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/One Running Metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/One Running Metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.AsperdetaileddrawingsandasdirectedbyEngineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. |
| 28 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. |
| 29 | ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)bytreatingthe bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifospersquaremeterofsurfaceareacovering10yearsguaranteeon bond paper. |
| 30 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequiredwidthinplain/diamondpatternonbedof1:6C.M.including cementfloat, filling joints with neat cement slurry, curing, polishing and cleaningetc. complete. |
| 31 | ProvidingandfixingP.V.C.Rainwaterpipesof110mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolvent cementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 32 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shade etc. complete.insert plate, (for insert plate, chequered plate and miscellaneous items) |
| 33 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear) |
| 34 | Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. |
| 35 | Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. |
| 36 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary andconveying and stacking the same in PWD chowky or as directed etc. complete. |
| 37 | Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of tank capacity of 1000 litres |
| 38 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copper wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as perspecification no SS-TR-NSL. |
| 39 | Supplying & erecting inline cut point end pole D. P. Structure for 11/0.415kV, 200 KVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos. 200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos.Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc.Angle of size 50 x 50 x6 mm for erecting Distribution Box, Transformer Belt etc.as per drawing (min.176 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire.D.P. Structure shall be erected in c.c. foundation complete. |
| 40 | Concreting ration 1:3:6 |
| 41 | DTC Metering with Box, single core L.T. XLPE cable (185 sq.mm, 200 mtr length) and other allied material |
| 42 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 185 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 43 | Supply and laying of Heavy duty RCC Hume pipe for road crossing, below plinth beam of following size as diameter : 150mm |
| 44 | Supply and laying of Heavy duty half circle RCC Hume pipe - 150mm Dia. |
| 45 | Providing and erecting Heat shrinkable straight through joint kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 185 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 46 | Providing and erecting Heat shrinkable outdoor termination kit for 11 KV € XLPE HT cable 3x185 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 47 | Sand |
| 48 | Misc. for XLPE U/G Cable |
| 49 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 50 | Supplying and erecting anti climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. |
| 51 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 125 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2/G3 and maximum fuel consumption 21.4 ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 230 ltr etc., on provided M20 grade CC foundation as per specification no. GEN-DG |
| 52 | Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 100 kVA upto 125 kVA capacity 3 phase, 415 V, 50 Hz, A.C. supply with all standard features, safeties etc as per specification no. GEN-AMF. |
| 53 | Supplying & erecting ON LOAD change over switch 4 Pole, 415V, 32A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 as per specification no. SW-SWR/COS. |
| 54 | Supplying and erecting mini feeder pillar with 415V, 315-320A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket and enclosure must be dust proof, rust proof, vermin and water resistant, having slanting top and erected on angle iron/ GI frame in provided C.C. foundation complete as per specification no. SW-MFP |
| 55 | Supplying and erecting fencing of section having size at least 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete with provided earthing as per specification no. SS-AS/FSG |
| 56 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Transformer Secondary to Change over switch, DG toChange over switch, Change over switch to Main distribution panel and Main distribution panel to Furnace Control Panel) |
| 57 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL - Main Distribution panel to Lighting distribution Board. |
| 58 | Providing & erecting hot dipped galvanised perforated type cable tray manufactured from 16 SWG GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 59 | Supply & installation of Earth conductor of the following sizes to be cleated on wall / columns with nuts & bolts or laid in cable tray / buried in ground including cutting, drilling, tapping, jointing by welding, connecting to equipments, painting to welded portion by black bitumen paint and with all necesary GI hardware & accessories to complete the worka) 25 X 6 GI strip |
| 60 | Supply & installation of Earth conductor of the following sizes to be cleated on wall / columns with nuts & bolts or laid in cable tray / buried in ground including cutting, drilling, tapping, jointing by welding, connecting to equipments, painting to welded portion by black bitumen paint and with all necesary GI hardware & accessories to complete the workBare G.I. Conductor size 8 SWG |
| 61 | Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge (C class) 40 mm dia 1.2mtr copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball of size 100mm as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner as per spicification no. EA-LA |
| 62 | Providing of flat conductor holder suitable for FL 30. Installedwith 2 hexagonal bolts. |
| 63 | Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer. |
| 64 | Supply & installation of Earth conductor of the following sizes to be cleated on wall / columns with nuts & bolts or laid in cable tray / buried in ground including cutting, drilling, tapping, jointing by welding, connecting to equipments, painting to welded portion by black bitumen paint and with all necesary GI hardware & accessories to complete the worka) 25 X 6 GI strip |
| 65 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 66 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for 4 pole incoming 400A, 8 ways 4 pole outgoing, up to 100A MCCBs on iron frame, as per specification no. SW-MCCBPB. (Excluding MCCBs) |
| 67 | Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 68 | Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer. |
| 69 | Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. |
| 70 | Supplying, erecting, testing & commisioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. |
| 71 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 72 | Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 73 | Supplying, erecting & marking FP MCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 74 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways/12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB. |
| 75 | Supplying, erecting & marking SP MCB 10A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 76 | Supplying, erecting & marking SP MCB 16A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 77 | Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 78 | Point wiring for light/fan/bell in 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification no. WG-PW/SW |
| 79 | Point wiring for light/bell concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW |
| 80 | Point wiring for ceiling fan concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW |
| 81 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW |
| 82 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 83 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 84 | Supplying and erecting PVC Surface modular switch box with doublemounting plate for 6 module complete. |
| 85 | Supplying and erecting PVC Surface modular switch box with doublemounting & front plate for 8 module complete duly connected |
| 86 | Supplying and erecting modular type switch 6A/10A on provided plate and box with wiring connections complete. |
| 87 | Supplying and erecting modular type two way switch 6A/10A (2 module) on provided plate and box with wiring connections complete. |
| 88 | Supplying and erecting modular type switch one way 16/20 A on providedplate and box with wiring connections complete with neon indicator. |
| 89 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. |
| 90 | Supplying and erecting anodized aluminium light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block/wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 91 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver comp |
| 92 | Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/SLB |
| 93 | Providing and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for230/250 Volts single phase, 50 cycles A.C. supply, with one metre of 3core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. |
| 94 | Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF |
| 95 | Providing Round bottom FIRE Bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook. Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver Paint. |
| 96 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 97 | Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete. |
| 98 | Supplying and fixing standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, antiseptic solution, etc. (All above contents shall be of standard makes) |
| 99 | Supplying of Safety MASK. |
| 100 | Providing & Fixing of printed instruction chart for (with minimum 700 x 1000 mm in size) treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete. |
| 101 | SUPPLY, INSTALL, TEST, COMMISSION of Electrical crematorium including furnace, refractory items, electrical heating coil, body charging trolley, control panel, fresh air blower, exhaust blower, scrubber unit, connecting to existing self-supporting chimney all etc., complete with the following specification.1) A) Main Furnace : Fabricated main furnace frame for housing refractory bricks and other equipment’s, main door, door lifting mechanism, manual and motor operating, Counter weight, Ash door, Ash tray and tools etc. Furnace cover with SS sheet with all other accessories. B) Refractory items: Furnace chamber, Secondary chamber, Smoke trench, Fresh air trench, constructed by refractory bricks. The above furnace chamber consisting of standard, Hot & Cold, Insulation bricks and also different size of refractory slabs arch bricks, for binding the bricks clay, mortar, castable and ceramic blanket use to complete the furnace chamber.C) Electrical Heating Coil as per relevant IS standards.D) Body Charging Trolley: The movable charging trolley made up of fabricated plate, channels, grouting frame etc. operated automatically. E) Control Panel: items include supply on/off switches, Digital Temp. Control two set point, indicating lamps for supply and to heaters, Thyrestor with contactors, Back-up Temp Control, Power select switches, Amp meters, Volt meter with select switch, Motor Starters for Inlet, Exhaust, door up/down, HRC fuses for control and power circuit, Flasher, Energy meter, Emergency off switch, MCCB. F) Fresh air blower: Blower of 1HP and connecting ducts for furnace chamber to provide a fresh air combustion of fire. G) Exhaust Blower for scrubber: (SS 304, 2MM sheet) Fabricated with body, fan, Shaft and bearing inlet and outlet pipe and 5 HP 3 phase motor to drive the blower, mounted on Frame work.2) Scrubber Unit: SS wet scrubber mounted on a platform. SS sheet, pipe connecting from smoke duct to scrubber/Exhaust fan/Chimney, and chimney connecting pipe, blower and pipeline, sheet and flanges as per relevant standards. 3) Erection Charges: Erection charges for (a)fixing of frame, Main Door, Counter weight, Mechanical and Electrical operating door system(b) refractory lining work (c) Fixing of fresh air blower, Construction of Trench, Fabrication of Scrubber lining work. Fixing of scrubber unit. Erection of self-supporting chimney. Erection and fixing of related Panels and other system/equipments. 4) Packing, Transportation, insurance charges, Loading and unloading charges at factory and site of all equipments. 5) RCC Foundation for other furnace related civil works.Including cost of all lead, lift, hire charges, labour & material etc. complete as per the relevant IS standard ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete. (Quantity required- One Set) |
| 102 | SUPPLY, INSTALL, TEST, COMMISSION of self-supporting chimney all etc., complete with the following specification. Self-supporting chimney: Supply of fabricated self-supported chimney with the following particulars: 1. Bottom Dia 1200mm, Top Dia 324mm, Height 30m and Thickness 16mm to 6mm2. Flanges of 25mm Thick3. 22mm Dia. Half Thread High Tension Nut/Bolts with one spring washer & two plain washers4. Earthing, Aviation Red Light 5. Foundation Bolts/Nuts 35mm Dia. X 1500mm Long6. Steel Core Wire Rope 10mm Dia./Or Manufacturers\" design approved by the Engineer including RCC foundation as per design. (Quantity required- One number) |
| 103 | Supplying & fixing of coil holding bricks vertical system 115 x 115 x 300mm. |
| 104 | Supplying & fixing of 3.5 KW Heating coils made out of 5.8mm Thick 80/20 grade nickel chromium wire, heating zone should be 950mm length, end terminal rod ss 304 grade 10mm dia 550mm length suitable for vertical mounting system in electrical furnace including porcelin beeds spacers supporting system complete. |
| 105 | Supplying & fixing of body laying with MCL 150X 300X600MM |
| 106 | Servicing & cleaning of scrubber, scrubber duct exhaust blower & duct furnace to chimney and cleaning of chimney (6 month once) |
| 107 | Accoset-50 grade or equivalent jointing material |
| 108 | Firecrete super or equivalent jointing material |
| 109 | Thermotex Refractory Cement or equivalent |
| 110 | Fire blanket of suitable grade |
| 111 | Plastic buckets 20L capacity |
| 112 | Plastic Mugs |
| 113 | Providing & erecting 3 Pole MCCB, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no lineload bias in provided enclosure/panel as per specification no. SW-MCCB |
| 114 | Supplying & erecting fuse bridges with base HC type fuse links 415V, 100A erected on polished wooden block. |
| 115 | Supplying & erecting fuse bridges with base HC type fuse links 415V, 200A erected on polished wooden block |
| 116 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. |
| 117 | Supplying & erecting crimping type copper lugs for cable 95 sq mm complete as per specification No. CB-CL/CU |
| 118 | Supplying & erecting crimping type copper lugs for cable 240 sq mm complete as per specification No. CB-CL/CU |
| 119 | Supply and fixing of 4 pole power contactor with NO/NC contacts on existing wood/ panel board using necessary bolts, nuts, washers and wiring etc, complete with AC-3 rating and as per IS-13947: 200Amps. |
| 120 | Supply and fixing of 4 pole power contactor with NO/NC contacts on existing wood/ panel board using necessary bolts, nuts, washers and wiring etc, complete with AC-3 rating and as per IS-13947: 65 Amps. |
| 121 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 122 | Supplying, erecting & marking FP MCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 123 | Aligning of body laying trolley, lifting frame wheels, greasing and servicing of body placing trolley |
| 124 | Aligning of furnace main door, gear , stop switch etc. |
| 125 | Rewinding of electric motor above 5 HP upto 7.5 HP three phase upto 1400 RPM of all types and makes with copper wire confirming to IS 13730: 2012, overhauling with minor repairs, lubricating of ball bearings & bush bearing, replacing screws etc. testing for the original speed and no load consumption with guarantee for one year |
| 126 | AMC of Electrical installation including wiringreplacement of burnt out spare parts of furnace and repairing of furnace panel board and re winding of fans, exhaust fan, scrubber parts, blowers etc complete |
| 127 | Licenced electrician (skilled) sl.no 54, P 545 |
| 128 | Operator, Fitter sl.no 54, P 545 |
| 129 | Material component -Soap oil |
| 130 | Material component -Phenyl |
| 131 | Material component -Dust cloth |
| 132 | Material component -Mop cloth |
| 133 | Material component -Soft broom |
| 134 | Material component -Hard broom |
| 135 | Material component -Road brush |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy