Tender For Improvement Ofe.I And Faninmunicipal Taxation Tribunal Court In Ward No 73Under City Sp Zone; 1 Wiring for light point /fan point /exhaust fan point /call ball point with 1.5sq.mm FRLS PVC installed copper conductor single core cable in surface / recessed PVC conduit, with piano type switch phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5sq.mm. FRLS PVC installed copper conductor single core cable etc as required. Group C 2 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C 3 Supply and fixing of following piano type swich/ socket on the existing switch box/ cover including connection etc as required. 4 5/6amps switch 5 15/16 amps switch 6 3 pin 5/6 amps socket outlet 7 6 pin 15/16 amps socket outlet 8 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 9 100 mm X 100 mm X 60 mm deep 10 150 mm X 75 mm X 60 mm deep 11 200 mm X 150mm X 60 mm deep 12 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessedPVC conduit as required. 13 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 14 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 15 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 16 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 17 Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a)12 way , Double door 18 Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a)08way , Double door 19 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole 20 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 21 63 amps 22 (a) 40amps 23 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required 24 Supply of 12(300 mm)sweep 1400 rpm heavy duty Exaust Fan complete with ring, blade etc as required. ISI marked. 25 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 26 S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95 27 P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd. asreqd. 28 Supply of 70 watt LED Street LightLuminaire fitted with lens made of pressure die cast aluminium housing and toughened glass cover complete with the following specifications as per relevant IS (a) Total System Wattage :70 Watt ± 5% (b) Luminaire Efficacy -130 Lumens/watt (minimum) (c) Power factor > 0.95 (d) Protection Class IP66 (e) LED Package shall be Ceramic Base. (f) Multi Chip. Array, Multi Die, Mid Power, Integrated Arrays and COB type Chip are not permitted (g) Operating Current of LED < 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h) Wattage of LED Package : One watt to Five watt maximum (i) CRI >70 (j) THD<10% for complete fixture (k) Operating Voltage – 110-320 V, 50Hz +/- 3%. (l) The driver must have thermal Protection against 75 deg C ambient temperature with internal SPD of minimum 6 KV. Separate Compartment for Driver (m) Life of Street Light: Minimum 50,000 hrs 29 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required (a) 3 x 1.5 sq. mm 30 Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2X10 sqmm 31 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required(a) Upto 35 sq. mm 32 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. 33 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as reqd. 34 SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N) 35 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminalspreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 36 (a)200 A,36KA,TPMCCB 37 (b)250 A,36KA,TPMCCB 38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 39 Installation and commissioning of street light/Flood light etc as required.