| 1 | Removing of curtains and unserviceable motors from the height of 30 feet apex. With the help of special T&P and refixing the same after repairing the motors and others accessories etc. as required. |
| 2 | Repairing and rewinding of show courts curtains motors, sensors, motor connectors, controller driver, cable tie & remotes etc. as required. |
| 3 | Supply and fixing of 3core 2.5 sq.mm copper cable for motor connection with thimbles etc. as complete as required. |
| 4 | Hiring charges of special Ladder made with scaffolding with Chali for dismantling of unserviceable motors with accessories and also requires for refixing the same after repairing i/c both side cartage etc. as complete as required. |
| 5 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required.Group C |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 7 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 8 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. for Power Point |
| 9 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required for AC points. |
| 10 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc.as required. |
| 11 | 1 or 2 Module (75mmX75mm) |
| 12 | 3 Module (100mmX75mm) |
| 13 | 6 Module (200mmX75mm) |
| 14 | 8 Module (125mmX125mm) |
| 15 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 16 | 5/6 A switch |
| 17 | 15/16 A switch |
| 18 | 3 pin 5/6 A socket outlet |
| 19 | 6 pin 15/16 A socket outlet |
| 20 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 21 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 22 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 23 | 3 x 1.5 sq. mm |
| 24 | 3 x 2.5 sq. mm |
| 25 | 3 x 4 sq. mm |
| 26 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulatedcopperconductorsinglecorecableand1.5sq.mmFRLSPVCinsulatedcopper conductorsinglecorecableasearthwireinexistingsurface/recessedsteel/PVCconduit including dismantling as required.Group C |
| 27 | \"Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.\" |
| 28 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 29 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. |
| 30 | Earthing with G.I.earth pipe 4.5 metrelong,40 mm dia including accessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 31 | Providing and fixing 25 mm X 5 mm G.I. strip on surfaceor in recess for connections etc. asrequired. |
| 32 | Providingandfixing25mmX5mmG.I.stripin40mmdiaG.I.pipefromearthelectrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 33 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 34 | 4 way (4 + 12), Double door |
| 35 | 6 way (4 + 18), Double door |
| 36 | 8 way (4 + 24), Double door |
| 37 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 38 | Single pole |
| 39 | Three pole and neutral |
| 40 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 41 | 63 A |
| 42 | 100 A |
| 43 | SITC of wall mounted Cubical elect. Pannels of size 1000x950x300 mm having 200 Amp bus bar,200 Amp 4 pole change over switch ,200 Amp 4 pole Mccb-1 ,100 Amp 4 pole Mccb-3 and 32 Amp DPMCB -3 nos i/c led indication lamp assembly. etc. complete as required. |
| 44 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 45 | 1 or 2 Module |
| 46 | 3 Module |
| 47 | 4 Module |
| 48 | 6 Module |
| 49 | 8 Module |
| 50 | 12 Module |
| 51 | Modular blank |
| 52 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 53 | Supplying and fixing following ratins MCBs suitablein the existing MCB DB and other lighting complete with connections, testingetc. as required. |
| 54 | 6-32 Amps SPMCB |
| 55 | 32 Amp DPMCB |
| 56 | 40 Amp TP&N MCB |
| 57 | Providing and fixing following rating and breaking capacity and pole MCCB with thermo-magneticreleaseandterminalspreadersinexistingcubiclepanelboardincluding drilling holes in cubicle panel, making connections, etc. as required. |
| 58 | 125 A,36KA,FPMCCB |
| 59 | 250 A,36KA,FPMCCB |
| 60 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessed conduit as required. |
| 61 | 20 mm |
| 62 | 25 mm |
| 63 | Supplyingof 20watt 4feetlong LEDBatten,withextrudedaluminiumhousing& poly-carbonate diffuser with integrated LED driver directly on wall / surface including connection with 1.5 mm2FRLS PVC insulated copper conductor single core cable and earthing etc. includingtesting & commissionong as reqd. |