Tender For Electrical Works For The Submersible Motors Installed In The Hostel Zone; 1 WIRING IN STEEL & PVC CONDUIT 2 Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. 3 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 4 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 5 3/4 Spring Metallic Hose 6 MCCB, MCB & DBS 7 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 8 125A,36KA,FPMCCB 9 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) 10 8 way , Double door 11 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar,interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) 12 Double pole 13 Supplying and fixing of following rating,Three/four pole,415 volts,Isolator/MCB in the existing MCB/DB complete with connections,testing and commissioning erc.as required. 14 Triple/Four Pole 40-63A MCB 15 Supplying and fixing of following rating,Three/four pole,415 volts,Isolator/MCB in the existing MCB/DB complete with connections,testing and commissioning erc.as required. 16 Four pole MCB6-32A with enclosure. 17 Supplying and fixing the following ways surface/ recess mounting, vertical type, 415 volts, TPN DB-VTPNdistribution board of sheet steel, dust protected, duly powder painted, inclusive of 160-250 amps tinned copper bus bar for each phase, with 2 neutral bar, 2 earth bar and cable ties for cable management, Fully insulated bus bar & Surrounded Neutral bars, din bar for mounting MCBs, with provision for DPX3 160 amps MCCB as incomer and SP/TP MCBs as outgoing, interconnection between incomer MCCB and bus bars (but without MCBs/ MCCB) as required .(Note : Vertical type MCCB TPDB is normally used where 3 phase outlets are required.) (Make: Legrand/Siemens) 18 8 way, 160A, door 19 MV CABLE LAYING 20 Laying of one number PVCinsulated andPVC sheathed / XLPE powercableof1.1KVgradeof followingsizedirectinground includingexcavationandrefillingthetrenchetc asrequired,but excluding sand cushioning and protective covering. 21 Upto 35 sq. mm 22 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. 23 Upto 35 sq. mm (clamped with 1mm thick saddle) 24 MV CABLE JOINTING & END TERMINATION 25 Supplyingandmakingendterminationwithbrass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. 26 4 X 16 sq. mm (28mm) 27 MISC CIVIL ITEMS 28 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete withfittingandcutting,jointingetc.intheexisting trench, complete as required. 29 40 mm dia (00-40 mm & ID-32 mm nominal) 30 Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : 31 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 32 FABRICATION OF CUBICLE BOARDS/LADDER/SOLAR STRUCTURE 33 Fabrication, supply of Starter Panel type made out of not less than 2.2 mm thick and Height 800mm Breadth 500mm width200mm MS sheet and angle iron base frame with hinged door on both side and gowden locks welded on the door i/c painting connection inter-connection etc. as per CPWD specifications (Part IV & V) of following size and providing and fixing following switch gears with cable entry boxes for both incoming and outgoing cables termination, glands, interconnection, connections powder coated painting, earthings , including of all erection, Labelling ofincoming and outgoing feeders & transport charges etc., as required. The panel drawing should be submitted before execution of the works. (Make:L&T/Legrand/Schneider/Siemens). 34 Supplying of Cables. 35 Supply of aluminiumArmouredXLPE UG CABLE1.1KV as per ISI Specification IS:7098/(Part-I) 1988 with latest amendments. 36 4x16 sq mm 37 Polycab PVC/ Xlpe Insulated and PVC Sheathed Industrial 3 core Flat Submersible Cable with Bare Bunched Copper Conductor for Submersible Pump Motors with Voltage Grade 1100 Volts as per IS:694/2010 38 3*4sq.mm 39 SUPPLY OF G.I PIPES AND ANGLES 40 Suppling and fixing of MS angle bracket / channel made of following length 1.8 metre with suitable clamping arrengement with bolt & nuts and provided with suitable fixing arrengement for erection of Starter Panle as required. 41 1800mm*50mm*50mm*(6mm Thickness) 42 Fixing of Meters/Hose/Acrylic sheets/UPS 43 Labour Charges for installing 3-Ph DOL Starter Panle 44 Fixing of 6 HP panel board Texmo/LT/BHC