| 1 | PART A - CIVIL WORK |
| 2 | Excavation for roadway in hard rock by wedging and chiselling or line drilling including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. |
| 3 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader/ Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - III Material |
| 4 | Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader / Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - II Material |
| 5 | Construction of dry lean cement concrete Subbase over a prepared subgrade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ CUM, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineerincharge , compacting with vibratory roller, finishing, curing and including preparation of subgrade surface if required etc. complete. |
| 6 | Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. |
| 7 | Providing & laying R.C.C. running beam in M-40 cement concrete including required formwork mixing, compacting & curing, etc. complete reinforced with 12mm dia. (Minimum 4 Nos.)M.S. main bars & 6mm Dia M.S. rings at 15cm/c/c to be anchored in slipper slab properly with M.S. reinforcement as per drawing etc. complete as specified (Steel will not be paid separately). Contractor has to make his own arrangement for portable waterfor construction / curing with hessian cloth, etc. & will not be paid separately. Beam Size: b) 23cm. x 30cm. |
| 8 | Providing and fixing heavy duty inter locking concrete Rubber mould glossy paving blocks of 80 mm thickness of having a strength of 400 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete. (using 100% crushed sand) |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for plain or molded sills, cornice, jambs, block in course, or architraves of required size and shapes including steel centering, plywood/steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.)with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixeretc. complete, With natural sand/V.S.I. quality Artificial Sand |
| 10 | Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils. By Mechanical Means |
| 11 | Providing rubble filling of trap/ granite/ quartzite gneiss stones for foundations including hand packing filling gravel / sand in the voids etc. complete. |
| 12 | Providing and laying in situ / ready mix cement concrete of M10 proportion with trap/ granite/ quartzite/ gneiss metal in foundation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer)) with SCADA with Natural / VSI standard Artificial Sand) |
| 13 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 14 | Providing and laying in situ / ready mix controlled grade of M25 of trap /granite /quartzite /gneiss metal for RCC works in cut off walls / curtain walls including necessary scaffolding, centering, compacting by vibrator, finishing and curing etc. complete. (with fully automatic micro processor based PLC with SCADA enabled with reversible drum type mixer/ concrete batch mix plant (pan mixer) with fine agreegates of required specifications ( VSI sand finely washed etc ), excluding reinforcement) |
| 15 | Providing and laying in situ / ready mix M25 controlled cement concrete of trap/ granite/ quartzite/ gneiss metal for RCC work in solid/ deck slab etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcementetc. complete. (height up to 4 meter with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer with Natural / VSI standard Artificial Sand) |
| 16 | Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) |
| 17 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 18 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. |
| 19 | Providing and laying in trenches 15 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 1.25 kg/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 20 | Providing and laying in trenches 20 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 1.63 kg/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 21 | Providing and laying in trenches 80 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 8.57 kg/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 22 | Providing and laying in trenches 100 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 12.43 kg/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 23 | Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. |
| 24 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. |
| 25 | Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 mm.to 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor & allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction & longitudinal joints (15 mm. deep x 8 mm.wide) |
| 26 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). |
| 27 | Providing & fixing high density polythene pipe of approved quality to fit around the dowel bars of 32 mm dia at the end of expansion joints,fully greased inside, cotton waste the pipe around the dowel bars & the pipe duly capped at the end as rected. (H.D.P. pipe shall be 30cm in length) As shown in the drawing |
| 28 | Providing and fixing in position TMT FE 500,32 mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 cm. C/C and wherever directedincluding handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete. |
| 29 | Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 5.0 to 9.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary. |
| 30 | Transportation of excavated material obtain from excavation including loading ,unloading and stacking upto 5 km etc.Complete. |
| 31 | Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat\"s Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shallsupport a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2mm and with minimum reflective area of 13 Sqcm on each side and the slope to the baseshall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks,(of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the bodyis to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for theshanks to go inside, without nails and using epoxy resin based adhesive as permanufacturer\"s recommendation and complete as directed by the engineer.The contractorshall submit a two year warranty for satisfactory field performance including stipulatedretro-reflectance of the reflecting panel, to the Engineer. |
| 32 | Providing and fixing kerbstone with led lighting system as per following specifications: dimensions with vertical mounting legs with 10mm horizontal square shape mild steel reinforcements. Illuminated kerb stone having visible dimensions :-500mm x 150mm x 150mm.(as per irc - 86-1983 ) 80mm legs having ms reinforcements shal be embedded in bt/concrete road surface.the kerb stone should have kerb angle of 45 degree, with rubber plugs at both ends of the kerbstones (2 nos)having load carrying capacity - vertical : 1465kg, horizontal : 2349 (certified by govt. Recoganized bodies)having thermal stability - : -40 to +120 degree celcius (certified by govt. Recoganized bodies. Illuminated kerb stones including : ingrace protection and connector rating ip67, electrical wire -(as per is: 694), led strip (as per lm:80) standard. Including for electrical fixing -frp junction box consisting of - 10amp. Switch module power supply(smps)having input voltage - 230v ac,output voltage 36v dc, 2 pole mcb. Illuminated kerb stones having warranty for 3 years. illuminated kerbstone shall be fixed into cast-in-situ cement concrete of m20 grade at base, back filling and grooves, including dismantling, fixing, removal of dismantled material and cleaning etc. Complete. The colour of kerb stone shall be provided as directed by engineer in charge. |
| 33 | Providing and fixing steel pipe delineators of 10 cm. in diameter and total height of 130 cm, provided with 2 strips of white retroreflective sheeting of size 5 cm. x 32.5 cm. each fixed horizontally and 2 strips of red retroreflective sheeting each having size 5 cm. x 32.5cm. fixed horizontally at top, with M.S. round cap having diameter 11 cm. and wire mesh at top (10 guage thick) and height of wire mesh 15 cm, M.S. hold fast 6 mm thick with 35 cm. in length, fixing the delineators in C.C. 1:4:8 concrete block of size 25 cm. x 25 cm. x45 cm. with necessary excavation etc. complete. |
| 34 | Vip Bench (Refer sketch 18) Product area:1.2 x 0.6 mts, Capacity in nos: 3 nos, Product height:0.90m |
| 35 | TESTING CHARGES+ROYALTY |
| 36 | ADD 18% G.S.T. (S.G.S.T. 9% + C.G.S.T. 9%) |
| 37 | ADD (1% Insurance) |