}

Tender For Retrofiting Of P And T Scheme At Gp Naner Village Kailashpuri Block Peeplu Of Distt. Tonk - 1 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpeisi Marked Pipes As Per Is-4984: 1995 (Amended Upto Date)With Necessary , malpura-Rajasthan

Public Health Engineering Department has published Tender For Retrofiting Of P And T Scheme At Gp Naner Village Kailashpuri Block Peeplu Of Distt. Tonk - 1 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpeisi Marked Pipes As Per Is-4984: 1995 (Amended Upto Date)With Necessary . Submission Date for this Tender is 21-05-2025. Water Supply Project Tenders in malpura Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49078585
Tender For Retrofiting Of P And T Scheme At Gp Naner Village Kailashpuri Block Peeplu Of Distt. Tonk - 1 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpeisi Marked Pipes As Per Is-4984: 1995 (Amended Upto Date)With Necessary
Open Tender
Indian
Rajasthan
Malpura
21-05-2025

Tender Documents

Tender Details

Tender For Retrofiting Of P And T Scheme At Gp Naner Village Kailashpuri Block Peeplu Of Distt. Tonk - 1 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 2 90 mm dia PE-80 PN-6 3 Providing, lowering,aligning, fixing inposition inpipe line, CI D/F Sluice valves straightandpocketlessbodypassageofapprovedmakeof following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facingring&Bushes-LTB2/SS ,FacetofacedimensionsasperIS14846/2000 (amendeduptodate),Epoxy(Non-Toxic-suitablefordrinkingwater)applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 andIS:1367/CS/galvanisedsteel InsertionrubberofblackEPDM6mmthick. Sluice valves including all jointing & jointing material, labour, testing and commissioningalongwithpipelineasperTechnicalSpecificationsandasper direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 4 sluice valvesDia80MMPN rating1.0 5 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: 6 All kinds of soil 7 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 8 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 9 Work of ineterconnection in AC/PVC/HDPE/ PIPE LINE UPTO 1.5 MTR DEPTH by digging out suitable size of pit of work including dewatering and providing adequte safety arrangement 10 in all type of soil 80MM TO 110 MM 11 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 12 M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 13 Supply&Installationof3phaseISImarkedsubmersiblemotorpumpsetof three star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283- 2013(motor)orasamendeduptodateofapprovedmakeoffollowing duty conditionwithrequiredaccessoriesincludingmakingconnectionsuitablefor tubewell/DCB.Thejobincludesloweringof motorpump,installationof complete fitting & accessories, jointing of electrical cables up to switch board, testingofsubmersiblepumpsetandinterconnectionuptowatermains, complete in all respect. 14 Up to 5.5 KW (7.5 HP) & head up to 120 mtr. 15 Providing & Lowering in open well ISI marked GI Pipe medium duty (“B class), SteeltubeasperIS:1239oramendeduptodateandzinccoatingasperIS 4736,threadedanddoubleflanged(welded)onbothendsandtwonumber 25x3mm MS flat welded on both ends between pipe & flange, rubber washer &nut bolts etc. complete in all respect. 16 50 mm dia 17 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 18 3 core 4.0 Sq.mm 19 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 20 Above 5 HP and up to 10 HP 21 Providing&Fixingofdoubleflanged,CIbody,ISImarkedNRVofapproved make of following sizes 22 65 mm dia 23 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 24 16.0 Sq.mm, 4 core

Key Value

Document Fees
INR 1000 /-
EMD
INR 43961.0 /-
Tender Value
INR 21.98 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail