| 1 | M&L for dismantling/taking down carefully by disconnecting of electric connection from pole/ wallsof any heights andany situation/location, place street light fittings type ofHPSV, HPMV, U/S LED street lights any wattage of flood lights, post top lanterns etc complete all as specified and directed by Engineer-in-Charge. |
| 2 | S&F LED Street light 90 Watt WARM WHITE 3000K with silicon gasket for IP 66 (no glue) protection suitable upto 50mm outer dia holder fixed on existing poles. LED street light shall be made up of pressure die cast alluminium LM 6 alloy housing with toughend glass, high power LEDs and secondary lenses with IP 66 protectionstop opening for separate driver compartment with frame, brand, logo embossed,toughened glass cover.High power ceramic base, CRI > 70,and bolted inside the luminaire panel.Average life class of 50000 hrsmetal body fully coatedphase to phase protection at 440 V upto 4 hours and > 300 V auto cut and restart feature.Luminaries and driver shall be of same make,lightsare connecting up with twin core flexible copper conductor cable complete all as specified and directed. |
| 3 | All as per Srl itemNo 2 here-in-before but capacity72 watt all as directed by Engineer-in-Charge |
| 4 | All as per Srl item No 2here-in-before but capacity 60 Watt all as directed by Engineer-in-Charge |
| 5 | All as per Srl item No 2here-in-before but capacity 45 Watt all as directed by Engineer-in-Charge |
| 6 | S&F energy saving LED INVERTER TYPE STREET LIGHT 45 WATTAND BATTERY BACK UP OFMINIMUM 2 HOURS environmental friendly, long life , exclusive innovative die-cast aluminium IP 66 security light with high power LEDs as light source,suitable for 40mm GI pipe, 5700K LED ofconnecting up with twin core twisted flexible copper conductor cablecomplete all as specified and directed. |
| 7 | All as per Srl item No 06 here-in-before but capacity 60watt all as directed by Engineer-in-Charge. |
| 8 | S&F in replacement of unserviceable driver for LED streetlight of capacity 90 to 120watt for any make and typeall as specified and directed by Engineer-in-charge. |
| 9 | All as per Srl item No 8 here-in-before but 30 to 72watt all as specified and directed by Engineer-in-charge. |
| 10 | S&F in repairof unserviceable driver for LED inverter type capacity 45 wattwith lithium battery backup min 2 hours complete all as specified and directed. |
| 11 | All as per Srl item No 10 here-in-before but capacity 60 watt all as specified and directed. |
| 12 | S&F in repair metal core PCB/MCPCB copper and aluminium core boards of street light any make of capacity 60 watt 3000K complete all as specified and directed. |
| 13 | All as per Srl Item No 12 here-in-before but capacity 70-72 watt all as directed. |
| 14 | S&F in replacement of cable protection GI tubinglight grade fixed along the pole/under road/along the wall of size 50mm bore with necessary clamps complete all as specified and directed. |
| 15 | S&F in replacement GI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5 mtr long, including MS clamps made out out of MS flat iron of size 40X4mm thick with nuts & bolts, washers complete drilling of holes for nuts and bolts etc all as specified and directed by Engineer-in-Charge. |
| 16 | S&F in repairof SINGLE phase8 KW automatic street light control switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Natureswitch operation based on natural light lux level. Switching offilluminance levelof minimum 30 Lux and switching off illuminance greater thanor equal to 10 Lux. The sensorhaving part night operation facility of min 4 hrs to maximum 12 hrs. Thecircuit shall have a provision for manual over ride operation. Thesensor along with suitable power contactors and incoming outgoing MCBs be enclosed on a pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof andFR grade with hensel enclosures, conforming to IP 66 complete all as directed byEngineer-in-charge. |
| 17 | All as per Srl item No 16 above but for 5 KW automatic street light. |
| 18 | Repair/ tightening of end terminals of street light fitting, flood light, post top lantern of any size/capacity at anyheightand repair the street lights, flood lights and post top lantern having minor faults i.e loose connections, carbon deposition, shiftingand refixing the same etc and makingthe light functional all as specified and directed by Engineer-in-Charge. Note:-(a)Complaint shall be done within 24 hrs afterintimation by JE E&M/ Engineer-in-Charge failling whichpenalty of Rs 250/- per day per complaint will be levied on contractor.(b)One supervisorwill report to JE E/M, Engineer -in-Charge on daily basis with complaint register. |
| 19 | S&FMCB 5 to 32Amp, SP\"C\" series complete all as specified and directed. |
| 20 | S&F in replacement of 3 polepower contactor of rating 25 to 45Amps as per existing make and rating all as directed by Engineer-in-Charge. |
| 21 | S&F of LED post top lantern with die cast housing cum heat sink with PMMA diffuser in IP-66 fitting of 30wattall as directed by Engineer-in-Charge. |
| 22 | S&F bollard LED light capacity 16watt all as specified and directed. |
| 23 | Supply and laying weather proof flat twin core cable aluminium conductor 1100 volts grade size 10 Sqmm including taking out old cable complete all as specified and directed. |
| 24 | Supply and erecting in steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) complete all as specified and directed. |
| 25 | S&F aluminium lugs eye type suitable for cable size 6 Sqmm to 10 Sqmm including necessary crimping with crimping tool complete all as specified and directed. |
| 26 | All as per Srl item No 25 here-in-before but of size 16 sqmm to 35 sqmm. |
| 27 | S&F LT straight through cable jointing kitheat shrinkabale complete with jointing materials suitable for LT armoured cable 2/4 core of size 16 sqmm to 35 Sqmm complete all as specified and directed. |
| 28 | S&F LT straight through cable jointing kitheat shrinkabale complete with jointing materials suitable for LT armoured cable 3.5/4 core of size sqmm 50 to 70 sqmmcomplete all as specified and directed. |
| 29 | S&F weather proof flat twin core cable aluminium conductor of size 2.5 sqmm 2 core all as specified and directed by Engineer-in-Charge. |
| 30 | S&F in replacement of junction box size 200x140x95mm poly corbonate with glass fibre reinforced, environment friendly, recylable, UV resistant, halogen and silicon free anti acid and anti corrosive IP 66/67 in accordancewith IE rule internally embedded gasket, junction box including 3 phase 415 volt aluminium bus bar anddin rail for fixing the MCB including one No MCB SP 6A 10KA to control the street light with necessary clamps, nuts bolts to fix the junction box with poles complete all as specified and directed. |
| 31 | M&L for preparation of old painted surfaces of electric pole removing complete dust and other deposited materials by cleaning from steel tubular pole of length upto 9 to 12 metres cross arms, bracing, clamps etc and painting with one coat of aluminium paint, repainting existing marking on pole and replacement of reflective band of 3M brand RED -YELLOW -RED alternate coloured 3 numbers of minimum 5cm in height wrapped all around the pole complete all as specified and directed by Engineer in Charge. |
| 32 | S&F for piercing connector for service connection suitable for 35 sq mm AB cable all as specified and directed by Engineer-in-Charge. |
| 33 | Re-stretching of existing ACSR conductor of any size any type as required sag fixed on OH line incl un-winding the conductor and insulators/cross arms on poles properly binding with alumminum complete all as specified and directed. |
| 34 | M&L for aluminium conductor steel reinforced (ACSR) over size of ferret/ weasels/ mink/ beaver etc fixing stretching and jumppering joining with aluminium wire complete all as specified and directed. |
| 35 | S&F in repair of shackle type insulator porcelain vitrous white, brown or green insulator incl galvanised mild steel straps washers insulators bolts washers of size 75x90 mm all as specified and directed. |
| 36 | Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting outcomplete all as specified and directed. |
| 37 | All as Srl item No 36 here-in-before but depth ec 1.5 mtr and not exc 3 mtr complete all as specified and directed. |
| 38 | Returning, filling in, including spreading, leveling,watering and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified. |
| 39 | Removal of excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 40 | Supply and laying brick common burnt sub class \"B\" old size (compressive strength not less than 75 kg per sqcm) for protection of cable laid in trenches for under ground cable complete all as specified and directed. |
| 41 | M&L for sand cushioning in trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified and directed. |
| 42 | Providing PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation for pole/ stay assembly foundation etc complete all as specified and directed by Engineer-in-Charge. |
| 43 | M&L forPCC 1:3:6 type D-2 (using 40mm graded crushed stone aggregate) as in foundation for pole/ stay assembly foundation etc complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping of pole including necessary form work and fair finished to exposed surfaces complete all as specified and directed. |
| 45 | M&L for road cutting, including excavation returning filling in, spreading levelling, well ramming in layers, soiling with, broken boulders stones, WBM 7.5 cm thick coarse aggregate received from dismentling the existing WBM of road, wateringand ramming, 40 mmthick PCC 1:2:4, type B-1 (using 20mm gradedcrushed stone aggregate) for road patch repair work, section/ cross section area of cutting shall becomplete as specified andasdirected by Engineer-in-Charge. |
| 46 | Supply and layingin replacement XLPE insulated armoured (under ground) heavy duty electic cable with stranded aluminim conductor 1100 volts grade of cross sectionalarea 16 Sqmm 4core laid in trenches/ ducts/ through pipes/in floor road/along the pole etc all as specified and directed by Engr-in-charge. |
| 47 | All as per Srl item No 46 here-in-before but of size 25 sqmm 4 core. |
| 48 | All as per Srl item No 46 here-in-beforfe but size 35 sqmm 3.5 core. |
| 49 | M&L for cross arms in replacement, bracing, supports, clamps and back plates, fabricated fromstructural steel section including nut bolts washers including welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide complete all as specified and directed. |
| 50 | M&L for binding the dislocated conductor with insulator on pole with aluminium conductorcomplete all asspecifiedand directed by Engineer-in-Charge.Note : (i)The rate of the aluminium conductor for binding shall be deemed to be included in quoted rate of the Contractor.(ii)Binding of 2x insulator shall be measuredas ONE JOB. |
| 51 | M&L for painting the PCC pole of 05 Nos bands/ strips of 30cm wide each with two coats of synthetic enamel paint (black and yellow) at a distance of 30cm from the plinth block upto 1500mm height and marking/sign writing of pole number and feeders locations of pole with synthetic enamel paint (white) including all MS fitting street light brackets MS flat angle iron GI pipe etc complete all as specified and directed to match the existing poles. |
| 52 | Cutting/trimming of tree branches of any width/ girth up to 3 mtr distanceof LT over load lines including collection and depositing the retrived timber at a place as directed by Engr-in-Charge. Note :- (i) Each span have a distance 35 mtr approximately. (ii) All cutting branches of tree shall be thrown away at approximately 500-700 mtr away as directed.(iii) Transportshall be provided by contractor forthrowingaway branches of trees, No extra payment will be made for transportation.(iv) Cuttingthe tree branches as and when required intimation sintimated telephonically/whatsappmsg or by letter to contractor, failing to do so a penalty ofRs 200/- per daywill be levied on the contractor. |
| 53 | M&L in replacement of sensor (NS-02) forsingle phase/ three phase as per existingcomplete all as specified and directed. |
| 54 | S&F in repairs 90 watt LEDlight fitting with dusk to down sensor made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studyness excellent corrosion resistance cable gland is used for maintaining ingress protection epoxy powder coated grey colour finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistance fixed to the housing withstainless steel screw, high efficiency long life LED module with the SMD LED package mounted on MCPCB with LED system lumen should not be less than 7400 lumen with PC lens to ensure better uniformity of light distribution, ambient temperature 35 degree celcius and system lumen 9000 for above.Power by built in isolatedelectronic driver SMPS base constant current supply with lower THD, output open slash short circuit protection, over voltage protection, phase to phase protection, surge voltage protection 10 KVA with IK 07 and IP-66 protection, CCT 5700K CRI more than 70 THD<10%, SPD 10 KV should be fixed with fitting, PF>0.95 IP66 IK07 protection with life of 50000hrs @ L70 operating temp -10 degree to +50 degree input supply voltage range 140/270V frequency 50/60Hz.Driver safty requirement standard : IS 15885/2/13, driver performance requirementIS16104, photobiological safety norms IS 16108 all as specified and directed. |
| 55 | S&F in repairs 120 watt LED flood light fitting pressure die cast aluminium alloy for housingwith heatresistance toughened glass IP66protection with PC lens for symmetric light distribution and toughened glass fixed on housing. LED system lumen efficacy should not be less than 12000 lumen.LM 79 and LM 80 report should be submitted to department.THD<10%, CRI>70, CCT 5700K, operating temperature -10 degree C to +45 degree C with integral electronic LED driver with APFC lower THD open circuit protection surge voltage protection upto 10 KV with built in SPD and other safety test as IS: 15885 Part-2/ Sec 13.IK 07, average life 5000hrs @ L70 B 50 on 12 to 16 mtr pole complete fixing on the existing steel tubular pole 16 mtr height including making electric connection complete all as specified and directed by Engineer-in-Charge. |
| 56 | A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender.The Schedule of Credit is pre-priced by MES.The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Crediti.e Rs. 2,59,550/- from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit. |