| 1 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 metre. In ground floor including roof.(a) upto 150 mm. thick |
| 2 | Dismantling carefully terraced floor only (including floor finish if any) or lime terracing in ground floor roof and removing rubbish as directed within a lead of 75 m.(a) In Ground Floor including roof. |
| 3 | Clearingcompoundpremisesofshurbs,plants, junglesetc. bycutting andremoving asdirected(Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared) |
| 4 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitatingtheuseof scraper,wirebrushetc.(Paymentagainstthis item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 5 | Removing loose scales blisters etc. from old painted surface and throughly smoothening the surface to make the same suitable for receiving fresh cost of paint. |
| 6 | Stripping off worn out plasterand raking out joints of walls, celings etc. upto any height and in any floor including removing rubbishwithin a lead of 75m as directed. |
| 7 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal /Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as perdirection of Engineer in charge |
| 8 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m.a) In ground floor including roof. |
| 9 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damages complete. (Concrete and brick work for mending damage will be paid separately) (a) Upto area 2.5 Sq.m |
| 10 | Plaster (toe wall, floor, ceiling etc.) with sand and cement mortar including rounding of for chamfering corners as directed and raking out joints including throating, no singanddrip course, scaffolding / staging where necessary (Groundfloor). [Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar.....(a) 20 mm thick plaster |
| 11 | (b) 15 mm thick plaster |
| 12 | (c) 10 mm thick plaster |
| 13 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m |
| 14 | Cement concrete with graded jhama khoa (30 mm size) excluding shutteringIn ground floor and foundation.(a) 1:3:6 proportion |
| 15 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. |
| 16 | Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer\"s specification [Cement to be supplied by the Department] |
| 17 | Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer\"s specified rate) for concrete of various grades. |
| 18 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).Sal : Local |
| 19 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. In ground floor. (In case of non-supply of single plank, penal rate of reduction of 20% will be made)(ii) 40mm thick shutters with 19mm thick panel of size 30 to 45 cm (c) Other Local Wood. |
| 20 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)…................40mm X 6mm, 250mm Length |
| 21 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISImark.100mm. X 58mm. X 1.90mm. |
| 22 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting…....(a) 200mm long |
| 23 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 24 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc |
| 25 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 26 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(a) On timber or plastered surface : Two coats (with any shade except white) |
| 27 | (b) On steel or other metal surface : With super gloss (hi-gloss) - Two coats (with any shade except white) |
| 28 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC......Two CoatGround floor, Two coats upto 4mtr. from G.L. |
| 29 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.....(Two Coat)a) Premium 100% Acrylic emulsion upto 4mtr. |
| 30 | Applying Acrylic Emulsion Paint of approved make and brand on walls and celling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer)(Two coats)…............Standard Quality |
| 31 | M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor)Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.At Ground floor |
| 32 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)i) Water based interior grade Acrylic Primer |
| 33 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge. |
| 34 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer\"s specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment] |
| 35 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer\"s specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). |
| 36 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed Work......................20 mm dia |
| 37 | Supplying, fitting and fixing bib cock or stop cock. PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm |
| 38 | Add GST @ 18% |
| 39 | Add Cess @ 1% |