Dairy Government Departments Closing in 0 days TDR #49076394

Tender For Supply Erection Testing Commissioning Of Milk Cold Room(Mcr) Of Storage Capacity Of 80,000 Liters Storage Capacity Of 10Mt Butter And Icecream Deep Freezer With Ante Room In Karaikudi Dairy

Issued by Government Departments · karaikudi, Tamil Nadu
Tender Value
86.20 Lakhs
Estimated cost
Bid Submission
28 May 2025
0 days left
EMD
86204
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
karaikudi → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Supply Erection Testing Commissioning Of Milk Cold Room(Mcr) Of Storage Capacity Of 80,000 Liters Storage Capacity Of 10Mt Butter And Icecream Deep Freezer With Ante Room In Karaikudi Dairy , Wall Mounted Type Air Cooling Unit Complete With Coil Section, Blower Section And Insulated Drain Pan Made Of Stainless-Steel Tubes Of Aisi 304 L With Aluminum Fins Having Fin Space Of 4 Fpi.The Blower Section Shall Be Comprising Suitable Quantity Highly Efficient Axial Flow Fan Directly Driven By Tefc Squirrel Cage Induction Motor. The Unit Shall Be Installed On Suitable Mounting Supports For Stability And Proper Alignment. Ammonia Liquid Accumulator To Be Supplied Along With Acu, Which Shall Be Suitable For Ammonia Gravity Feed System. , Acu For Milk Cold Room (10 Tr Capacity) , Acu For Ante Room( 1 Tr Capacity) , Liquid Feed Assemblies Shall Be Provided For Each Acu Consist Of Ammonia Liquid Level Switch, Strainer, Liquid Solenoid Valve, Isolating Valve, Valved Bypass, Metering Valve, Purge Valve, Pressure Gauge, Oil Drain Valve And Reflux Type Ammonia Liquid Level Gauge. , Refrigerant Pipelines, Valves And Fittings With Necessary Support For Inter Connection Of All Proposed Air-Cooling Units Interconnecting With Existing Refrigeration System Comprising Of Liquid And Suction Line.The Pipelines Shall Be Heavy Duty M.S. Seamless Of Sa 106 Gr.B And Schedule As Per Refrigeration Standards. , Water Pipelines, Valves And Fittings In Accordance With G.I. Medium Duty ‘B’ Class Pipes, Fittings And Valves For Acu Defrost And Drain With Necessary Pipeline Supports And U - Traps With Adequate Distance Supplied With Necessary Anchors, Guides, Hangers. , Insulation Of Suction Line, Liquid Lines And Headers With Suitable Thickness Of Puf Insulation Of Suitable Density As Per Tender And Cladded With 24 Gauge Aluminum Sheet. , Cubical Type Sub-Mccis Suitable For Indoor Installation Comprising 0F Start & Stop Push Buttons, Starter, Indicating Lights On, Off & Trip And Interlock For Auto Cutoff For Acu, Air Curtainand Internal Lighting. , Power Wiring With Electrical Accessoriesfor Interconnection Of Various Refrigeration Equipments Offered By The Bidder Providing Sub Mcc And Distributing Power To Various Acus, Air Curtain & Internal Lighting. The Power Cables Rating Shall Be As Per Tender. Control Wiring With Electrical Accessories For Various Refrigeration Equipments To Be Supplied By Bidder, The Control Cable For Use On 415 Volts System Shall Be Of 1100 Volt Grade Copper Conductor, Pvc Insulated As Per Is:1554 (Part- I) – 1988 Amended Up To Date. All Cable Laying Shall Be Done Properly In Pvc Condult Pipes With Appropriate Clamping And Support. , Cold Room Floor Insulation Will Be With Puf Sheets Conforming To Is: 4671-1984, In Double Layer. The Density Of Puf Sheet Will Be 40 ± 2 Kg /M³.The Supply Includes Enough Vapor Barrier Such As Tar-Felt, Polythene Sheet And Blown Bitumen Of 85/25 Grade.The Floor Insulation Will Be Laid As Per Is: 661-1974.The Floor Insulation Thickness As Mentioned Below. , Floor Insulation For Bdf.(120 Mm Thick) , Floor Insulation For Mcr And Ante Room.(80 Mm Thick) , Pre-Engineered Prefabricated Rigid Poly Urethane Foam (Puf) Panels Of Various Thickness As Given Below And Laminated With 0.5 Mm Thick Pcgi Sheet On Both Sides For Ceiling & Walls And Panel Fixing Accessories. , Side Wall & Ceiling Puf Panel For Bdf.(150 Mm Thick) , Side Wall & Ceiling Puf Panel For Mcr, Ante Room And Partition((80 Mm Thick) , Hinged Door Made From Puf Material Having Both Sides Ss Sheets Complete With Accessories.Doors Having Unique Feature Which Allows A Worker To Use Emergency Exit System Provided On Inside Door. , Door Size For Mcr & Ante Room: 1.2 M X 2.1 M.(80 Mm Thick) , Door Size For Bdf: 1.2 M X 2.1 M(120 Mm Thick) , Hatch Door Size Of 0.9 M X 0.9 M Made From Puf Material Having Both Sides Ss Sheets Complete With Accessories. (80 Mm Thick) , Internal Electrification For All Proposed All Cold Rooms / Ante Room With Vapor Proof Light Fittings For Adequate Illumination Inside The Chamber As Per Tender Specification. , Air Curtains Operated On 3 Phase Electric Supply To Be Installed At Mcr Doors, Ante Room Door And Hatch Door. The Air Curtains Shall Be Of High Velocity Type Complete With Centrifugal Blower And Limit Switch. The Air Curtain Shall Be Suitable For Door Size. The Air Velocity Shall Be 13 To 14 Mps. , Pvc Air Shield Curtains Having Flaps Of 3–Mm Thick With 50% Overlap Between Adjacent Flaps. , Safety Systems Per Tender Specification For Proposed New Mcr, Bdf & Ante Room Comprising Of Safety Pilot Light. , R404a Freon Based Condensing Unitas Per Tender Specification For Bdf With Semi-Hermetic/Hermetic Compressor, Force Draft Indoor Air Cooler, Electrical Control Panel With Servo Stabilizer And Interconnecting Refrigeration Piping With Insulation. (3 Tr Capacity) , Erection, Installation, Testing And Commissioning Of Ammonia Refrigeration Equipments, Freon Condensing Unit, Puf Panels For Ceiling & Walls, Doors, Air Curtains And Air Strip Curtain Etc., , Supplying And Installing A Gas Detection System For Both Ammonia And R404a Refrigerants, Including Suitable Electrochemical/Infrared Sensors, With A Centralized Control Panel Placed In The Control Room At Operator Level Interface, Integrated With Zone Wise Display, Hooters And Flashing Lights For Leak Detection And Safety Alerts , Supplying And Installing Room Temperature Sensors With Large-Type Digital Display Modules For Temperature And Humidity, Mounted At The Room Entrance

BOQ

Name of Work: Supply, erection, testing & commissioning of Milk cold room (MCR) of storage capacity of 80,000 liters & storage capacity of 10 MT butter and icecream deep freezer (DF) with ante room in karaikudi dairy
Sl. No. Item Description
1Wall Mounted type Air Cooling Unit complete with coil section, blower section and insulated drain pan made of stainless-steel tubes of AISI 304 L with aluminum fins having fin space of 4 FPI.The blower section shall be comprising suitable quantity highly efficient axial flow fan directly driven by TEFC Squirrel Cage Induction Motor. The unit shall be installed on suitable mounting supports for stability and proper alignment.Ammonia Liquid accumulator to be supplied along with ACU, which shall be suitable for ammonia gravity feed system.
2ACU for Milk Cold Room (10 TR Capacity)
3ACU for Ante Room( 1 TR Capacity)
4Liquid feed assemblies shall be provided for each ACU consist of Ammonia Liquid Level Switch, Strainer, Liquid Solenoid Valve, Isolating Valve, Valved Bypass, Metering Valve, Purge Valve, pressure gauge, Oil Drain Valve and Reflux type Ammonia Liquid Level Gauge.
5Refrigerant pipelines, valves and fittings with necessary support for inter connection of all proposed air-cooling units interconnecting with existing refrigeration system comprising of liquid and suction line.The pipelines shall be heavy duty M.S. seamless of SA 106 Gr.B and schedule as per Refrigeration Standards.
6Water pipelines, valves and fittings in accordance with G.I. medium duty ‘B’ class pipes, fittings and valves for ACU defrost and drain with necessary pipeline supports and U - traps with adequate distance supplied with necessary anchors, guides, hangers.
7Insulation of suction line, liquid lines and headers with suitable thickness of PUF Insulation of suitable density as per tender and cladded with 24 Gauge aluminum sheet.
8Cubical type Sub-MCCis suitable for indoor installation comprising 0f start & stop push buttons, Starter, indicating lights ON, OFF & TRIP and interlock for Auto Cutoff for ACU, Air Curtainand Internal Lighting.
9Power wiring with Electrical Accessoriesfor interconnection of various refrigeration equipments offered by the Bidder providing sub MCC and distributing power to various ACUs, Air Curtain & Internal Lighting. The power cables rating shall be as per tender. Control wiring with Electrical Accessories for various refrigeration equipments to be supplied by Bidder, the control cable for use on 415 Volts system shall be of 1100 Volt grade copper conductor, PVC insulated as per IS:1554 (Part- I) – 1988 amended up to date.All cable laying shall be done properly in PVC condult pipes with appropriate clamping and support.
10Cold Room Floor Insulation will be with PUF Sheets conforming to IS: 4671-1984, in double layer. The density of PUF Sheet will be 40 ± 2 Kg /m³.The supply includes enough vapor barrier such as tar-felt, polythene sheet and blown bitumen of 85/25 Grade.The floor insulation will be laid as per IS: 661-1974.The floor insulation thickness as mentioned below.
11Floor insulation for BDF.(120 mm thick)
12Floor insulation for MCR and Ante Room.(80 mm thick)
13Pre-Engineered prefabricated rigid POLY URETHANE FOAM (PUF) Panels of various thickness as given below and laminated with 0.5 mm thick PCGI Sheet on both sides for Ceiling & Walls and Panel fixing accessories.
14Side Wall & Ceiling PUF panel for BDF.(150 mm thick)
15Side Wall & Ceiling PUF panel for MCR, Ante Room and Partition((80 mm thick)
16Hinged door made from PUF material having both sides SS sheets complete with accessories.Doors having unique feature which allows a worker to use emergency exit system provided on inside Door.
17Door Size for MCR & Ante Room: 1.2 m x 2.1 m.(80 mm thick)
18Door Size for BDF: 1.2 m x 2.1 m(120 mm thick)
19Hatch door Size of 0.9 m x 0.9 m made from PUF material having both sides SS sheets complete with accessories. (80 mm thick)
20Internal electrification for all proposed All Cold Rooms / Ante Room with vapor proof light fittings for adequate illumination inside the chamber as per tender specification.
21Air Curtains operated on 3 phase electric supply to be installed at MCR doors, Ante Room Door and Hatch Door. The air curtains shall be of high velocity type complete with centrifugal blower and limit switch. The air curtain shall be suitable for door size. The air velocity shall be 13 to 14 MPS.
22PVC air shield curtains having flaps of 3–mm thick with 50% overlap between adjacent flaps.
23Safety systems per tender specification for proposed new MCR, BDF & Ante Room comprising of safety pilot light.
24R404A Freon Based Condensing Unitas per tender specification for BDF with Semi-Hermetic/hermetic Compressor, Force Draft Indoor Air Cooler, electrical Control Panel with Servo Stabilizer and interconnecting refrigeration piping with insulation. (3 TR Capacity)
25Erection, Installation, Testing and commissioning of Ammonia Refrigeration Equipments, Freon Condensing Unit, PUF Panels for ceiling & walls, Doors, Air Curtains and Air Strip Curtain etc.,
26Supplying and installing a gas detection system for both ammonia and R404A refrigerants, including suitable electrochemical/infrared sensors, with a centralized control panel placed in the control room at operator level interface, integrated with zone wise display, hooters and flashing lights for leak detection and safety alerts
27Supplying and installing room temperature sensors with large-type digital display modules for temperature and humidity, mounted at the room entrance

AI Tender Summary

OUR REF NO 49076394
AUTHORITY Government Departments
TENDER VALUE 86.20 Lakhs
LAST DATE 28-05-2025
Authority
Authority Name Tamilnadu Co-op Milk Producers Federation Limited
Work Description Supply Erection Testing Commissioning Of Milk Cold Room(Mcr) Of Storage Capacity Of 80,000 Liters Storage Capacity Of 10Mt Butter And Icecream Deep Freezer With Ante Room In Karaikudi Dairy , Wall Mounted Type Air Cooling Unit Complete With Coil Section, Blower Section And Insulated Drain Pan Made Of Stainless-Steel Tubes Of Aisi 304 L With Aluminum Fins Having Fin Space Of 4 Fpi.The Blower Section Shall Be Comprising Suitable Quantity Highly Efficient Axial Flow Fan Directly Driven By Tefc Squirrel Cage Induction Motor. The Unit Shall Be Installed On Suitable Mounting Supports For Stability And Proper Alignment. Ammonia Liquid Accumulator To Be Supplied Along With Acu, Which Shall Be Suitable For Ammonia Gravity Feed System. , Acu For Milk Cold Room (10 Tr Capacity) , Acu For Ante Room( 1 Tr Capacity) , Liquid Feed Assemblies Shall Be Provided For Each Acu Consist Of Ammonia Liquid Level Switch, Strainer, Liquid Solenoid Valve, Isolating Valve, Valved Bypass, Metering Valve, Purge Valve, Pressure Gauge, Oil Drain Valve And Reflux Type Ammonia Liquid Level Gauge. , Refrigerant Pipelines, Valves And Fittings With Necessary Support For Inter Connection Of All Proposed Air-Cooling Units Interconnecting With Existing Refrigeration System Comprising Of Liquid And Suction Line.The Pipelines Shall Be Heavy Duty M.S. Seamless Of Sa 106 Gr.B And Schedule As Per Refrigeration Standards. , Water Pipelines, Valves And Fittings In Accordance With G.I. Medium Duty ‘B’ Class Pipes, Fittings And Valves For Acu Defrost And Drain With Necessary Pipeline Supports And U - Traps With Adequate Distance Supplied With Necessary Anchors, Guides, Hangers. , Insulation Of Suction Line, Liquid Lines And Headers With Suitable Thickness Of Puf Insulation Of Suitable Density As Per Tender And Cladded With 24 Gauge Aluminum Sheet. , Cubical Type Sub-Mccis Suitable For Indoor Installation Comprising 0F Start & Stop Push Buttons, Starter, Indicating Lights On, Off & Trip And Interlock For Auto Cutoff For Acu, Air Curtainand Internal Lighting. , Power Wiring With Electrical Accessoriesfor Interconnection Of Various Refrigeration Equipments Offered By The Bidder Providing Sub Mcc And Distributing Power To Various Acus, Air Curtain & Internal Lighting. The Power Cables Rating Shall Be As Per Tender. Control Wiring With Electrical Accessories For Various Refrigeration Equipments To Be Supplied By Bidder, The Control Cable For Use On 415 Volts System Shall Be Of 1100 Volt Grade Copper Conductor, Pvc Insulated As Per Is:1554 (Part- I) – 1988 Amended Up To Date. All Cable Laying Shall Be Done Properly In Pvc Condult Pipes With Appropriate Clamping And Support. , Cold Room Floor Insulation Will Be With Puf Sheets Conforming To Is: 4671-1984, In Double Layer. The Density Of Puf Sheet Will Be 40 ± 2 Kg /M³.The Supply Includes Enough Vapor Barrier Such As Tar-Felt, Polythene Sheet And Blown Bitumen Of 85/25 Grade.The Floor Insulation Will Be Laid As Per Is: 661-1974.The Floor Insulation Thickness As Mentioned Below. , Floor Insulation For Bdf.(120 Mm Thick) , Floor Insulation For Mcr And Ante Room.(80 Mm Thick) , Pre-Engineered Prefabricated Rigid Poly Urethane Foam (Puf) Panels Of Various Thickness As Given Below And Laminated With 0.5 Mm Thick Pcgi Sheet On Both Sides For Ceiling & Walls And Panel Fixing Accessories. , Side Wall & Ceiling Puf Panel For Bdf.(150 Mm Thick) , Side Wall & Ceiling Puf Panel For Mcr, Ante Room And Partition((80 Mm Thick) , Hinged Door Made From Puf Material Having Both Sides Ss Sheets Complete With Accessories.Doors Having Unique Feature Which Allows A Worker To Use Emergency Exit System Provided On Inside Door. , Door Size For Mcr & Ante Room: 1.2 M X 2.1 M.(80 Mm Thick) , Door Size For Bdf: 1.2 M X 2.1 M(120 Mm Thick) , Hatch Door Size Of 0.9 M X 0.9 M Made From Puf Material Having Both Sides Ss Sheets Complete With Accessories. (80 Mm Thick) , Internal Electrification For All Proposed All Cold Rooms / Ante Room With Vapor Proof Light Fittings For Adequate Illumination Inside The Chamber As Per Tender Specification. , Air Curtains Operated On 3 Phase Electric Supply To Be Installed At Mcr Doors, Ante Room Door And Hatch Door. The Air Curtains Shall Be Of High Velocity Type Complete With Centrifugal Blower And Limit Switch. The Air Curtain Shall Be Suitable For Door Size. The Air Velocity Shall Be 13 To 14 Mps. , Pvc Air Shield Curtains Having Flaps Of 3–Mm Thick With 50% Overlap Between Adjacent Flaps. , Safety Systems Per Tender Specification For Proposed New Mcr, Bdf & Ante Room Comprising Of Safety Pilot Light. , R404a Freon Based Condensing Unitas Per Tender Specification For Bdf With Semi-Hermetic/Hermetic Compressor, Force Draft Indoor Air Cooler, Electrical Control Panel With Servo Stabilizer And Interconnecting Refrigeration Piping With Insulation. (3 Tr Capacity) , Erection, Installation, Testing And Commissioning Of Ammonia Refrigeration Equipments, Freon Condensing Unit, Puf Panels For Ceiling & Walls, Doors, Air Curtains And Air Strip Curtain Etc., , Supplying And Installing A Gas Detection System For Both Ammonia And R404a Refrigerants, Including Suitable Electrochemical/Infrared Sensors, With A Centralized Control Panel Placed In The Control Room At Operator Level Interface, Integrated With Zone Wise Display, Hooters And Flashing Lights For Leak Detection And Safety Alerts , Supplying And Installing Room Temperature Sensors With Large-Type Digital Display Modules For Temperature And Humidity, Mounted At The Room Entrance
Basic Detail
Tender No 1445/PSIII/2025
Bidding Type Tender
Location
City karaikudi
State Tamil Nadu
Key Dates
Publish Date 09 May 2025
Submission Date 28 May 2025
Open Date 28 May 2025
Finance
Tender Value 86.20 Lakhs
Tender Fee Ref. Documents
EMD 86204
Exemption Available
Document List
b83c284a-5f56-4592-a3c9-f4e54275140a.html
BOQ_664186.xls
MCRDocument.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 09, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
May 28, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 28, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b83c284a-5f56-4592-a3c9-f4e54275140a.html

xls

BOQ_664186.xls

pdf

MCRDocument.pdf

pdf

Tendernotice_1.pdf

Disclaimer