| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-05-2025 | Corrigendum_II | Other | 22-05-2025 |
| 2 | 14-05-2025 | Corrigendum - I | Date | 22-05-2025 |
| Sl. No. | Item Description |
| 1 | Civil work |
| 2 | Demolishingany type of masonary brick / AACwork manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.; In cement mortar |
| 3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 4 | Dismantling stone/tile flooring, skirting, dedo etc. laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 5 | Dismantling aluminium/ Gypsum partitions, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 6 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 7 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres |
| 8 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 9 | Removing any type of paint (dry or oil) including putty, primer and scraping and sand papering the wall surface smooth including necessary repairs to scratches complete. Work complete including all type of tools, tackles, scaffolding etc complete as per instruction of Architect/EIC. |
| 10 | Removalof existing All toilet block sanitary fittings like wash basin w.c. pan, Indianand Europeon type flushing tank , Urinal ,all type of cock , accessories , basin counter, trap etc. including stacking of the materials with all lead and lift. As per existing site conditions work complete as per the instruction of EIC. (all toilet) |
| 11 | Removing and modification of existing plumbing as per drawing inlcuding all type of pipe, cock, accessories etc. including stacking of the materials with all lead and lift. As per existing site conditions work complete as per the instruction of EIC. (Building all type plumbing) |
| 12 | RCC Core cut :Drilling with core cutting machine in RCC beams,slabs,floors etc.,for laying pipes and rendering the same in RCC 1:2:4 finishing the same to the satisifaction of the Architect/EIC.etc., complete, at all levels. The rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes upto any depth at all heights & levels. Work complete including all type of tools, tackles, scaffolding, safety measuresetc complete as per instruction of Architect/EIC. a) 100 mm dia |
| 13 | RCC Core Cut : b) 150mm dia. |
| 14 | RCC Core Cut : b) 200mm dia. |
| 15 | Labour charges for Shifting of Existing furniture or any type of work like shifting, remove and Reinstallation/ fixing itemas per specified location as per direction by EIC/Architect. etc. complete. |
| 16 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 17 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
| 18 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 19 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.a) Concrete of M25 grade with minimum cement content of 330 kg /cum : All works upto plinth level |
| 22 | b) Concrete of M25 grade with minimum cement content of 330 kg /cum: All works above plinth level to all floor level : superstructure |
| 23 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding , rebard etc all complete. all level, all floor. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 27 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth levelto all floor level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 28 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth levelto all floor level : Cement mortar 1:4 (1 cement :4 coarse sand) |
| 29 | CEMENT PLASTER (IN COARSE SAND): Providing and laying plaster in all floor, all height, all level : 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) |
| 30 | CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT: 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand). Incl. all floor, all height, all level etc. complete |
| 31 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. Including grooves finish, all floor, all height, all level etc. complete |
| 32 | Extra for providing and mixing water proofing material in cement per bag of plaster work in proportion recommended by the manufacturers. |
| 33 | Interior Paint : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. including, scaffolding, accessories, all height, all floor, all level etc. complete. Two coats |
| 34 | Wall Primer: Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. including, scaffolding, accessories, all height, all floor, all level etc. complete. |
| 35 | Putty: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. including, scaffolding, accessories, all height, all floor, all level etc. complete. |
| 36 | Exterior Paint: Finishing walls with textured exterior paint of exposed RCC look or required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. including, scaffolding, accessories, all height, all floor, all level etc. complete. |
| 37 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 38 | Light Weight Filling in the Sunken Portion: Providing and filling the cavity of sunken portion of toilets (after application of principal waterproofing treatment to surface of sunk RCC slab) withbroken AAC blocks of 25 mm to 115 mm in size with 50% of cement mortar 1:4 conforming to IS : 2645 complet as directed by the Engineer-in-charge. |
| 39 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish, Size of Tile 600 x 1200 mm : Equivalent toVarmora Letto steel 600x1200mm |
| 40 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 1200 mm : Equivalent toVarmora Letto steel 600x1200mm |
| 41 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish, Size of Tile 600 x 600 mm (Toilet area flooring) Equivalent to SUNHEART ENRICH GREY (MATT) SIZE : 600 x 600 |
| 42 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in dedo, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x1200 mm (Toilet area dedo andskirting) Equivalent to SUNHEART KEEN BLANCO (GLOSSY) SIZE : 600 x 1200 |
| 43 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 44 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing andmirror polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 45 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing andmirror polishing , antiskid groovecomplete. |
| 46 | Terrace flooring :Providing and fixing Cool roof tiles :600 x 600 mm as per approved sample by Architect ,on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. Basic rate of tiles 35/ Sq.ft |
| 47 | Artificial stone Door Frame: Providing and fixing 15 mm thick one-piece Artificial stone as per approved shade in door jambs lining for door frames for fixing door shutters in two overlapping bands to give an over all width not less than 280mm with cement mortar 1:3 andneat cement float in proper line, level and plumb ,filling the joints in matching colour pigment to match the stone shade, supports, scaffolding and moulding etccomplete in all aspects as per drawing and directed by Architect/ Engineer. No Overlapping will be paid for measurement. Basic rate of Artificial stone : Rs. 150/ Sq.ft |
| 48 | Artificial Stone window sill : Providing and fixing 15 mm thick one-piece Artificial stone as per approved samplefor window sills, jambs and soffits (surrounds on all 4 sides of the opening) as per detail drawings includingtwo overlapping bands, moulding, chamfer with polishing in cement mortar 1:3 (1 cement : 3 Coarse sand) of 12mm thickness/ suitable adhesives/ proper clamping and neat cement floating to proper line, level and plumb, filling the joints with white cement including approved pigment to match the colour of granite slab, cleaning, curing, scaffoldingetc. complete in all aspects and as directed by Architect/Engineer. Basic rate of Artificial stone: Rs. 150/ Sq.ft |
| 49 | Providing and fixing 12 mm thick Marine plywood conforming to IS: 710 / WPC board .Work complete including all necessary hardware and fittings , mock up sample, loading,unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 50 | Vinyl flooring:Providing and fixing 2mm thick Exoro Luxury Vinyl Vinyl flooringincluding necessary material, adhesive, tools, tackles, fittings etc complete. The Material Will be fixed with FEVICOL SR 505 Adhesive. Work complete for at all floor, all level, all depth, all Height, all lead and lift etc. work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC. 2 mm thick Vinyl flooring Code: Exoro LE _201 |
| 51 | Mirror polishing onExisting kota stone / marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 52 | Carpet Flooring Work: Providing & layingcarpet flooringas per approved make & Sample by Architect.A ) Carpet Roll Yarn100 % Olefin ( Solution Dyed ), B )Yarn Weight 23 0z/ SYD or 650 gm/ SQ MT C ) Stitch Rate 42/10 CM D ) Thickness of Tile 6 MM E ) Density Of Yarn 165480/sqmF ) Static Generation <3KV(AATC-134)G ) Use Classifications Commercial H ) International Fire Classifications (ASTM D 2859-Pass 8/8) I ) Guarantee 5 Years J ) Size of Roll 3.66 MT X 30 MTS - 35 MTSCarpet fixed with SR 505 Pidilite or equivalent tile adhesive and underlay foam material. carpet should be laid as closure to each other.Contractor will take care for level matching with other area flooring. Scope includes labour, under lay material, disposal of debris, necessary cutting of tiles without damaging the edges, including to provide& fixing ofSS 304 finish end profile , skirting ,edge profile etcto protect and cleaning, etc. complete. All works are carried as per detail drawing / instruction of architect / EIC. Before laying carpet contractor shall prepare even surface as per required. basic rate of carpet is Rs. 110/ Sq.ft |
| 53 | Melamine polishing on wood work (one or more coat). |
| 54 | Artificial stone Basin Counter600 wide: Providing & fixing two layers of wash basin counter, first layer (top layer) using approved shade and sample of 15 mm thick artificial stone and second layer (base layer) using 25mm thick Kotastone of approved shade, joined together with 1:4 Cement mortar bedding / approved tile adhesive, to true plane & level or to slopes, or close jointed with cement slurry with pigment of matching shade and colour and finishing with the same, including dedo 6\", cutting stone as per required shape & size to fit Wash basin & 4\" facia with moulding, nosing, chamfered front edges, fixing, disposal of debris etc. finished as per design in detail drawing and instruction of Architect/EIC. sample mock shall be approved from Architect/EIC. The granite shall be fixed at end of counters where counter is not resting on wall supoort. The edges of end support, fascia patti etc shall be moulded, polished as directed and complete in all aspects as per detail drawings. Centre line length of the counter shall be measured for payment purpose. Basic rate of stone is Rs.150 / Sq.ft |
| 55 | Granite Pantry Platform 600 wide: Providing & fixing in position Kitchen platform with mimum 600mm width made as under:Vertical supports: Made out of 18 mm thick white marble slabs sandwich supports (two slabs joined together using Araldite adhessive to full surfae area)placed at specified spacing as per detailed drawing and suitable to house modular kitchen under the counter Trolleys. Rate includes providing vertical garnite band to vertical supports with moulded/polished edges. Kitchen Counter Top : Finished with 18+/-2mm approved first qulaity, Colour, shade and textutremirror polished classic grey Granite slab (minimum length of slab shall not be less than 1.80 Meter for Kitchen counter etc.) resting on 18mm thick white marble base support slab (in one piece) and fixed with CM 1:2 or approved tile adhessive as directed at site. Front Facia: 50 to 75mm wide Granite band in one piece not less than 1.80 RM in length for kitchen counter with mirror polishchamphered edges complete as per Architectural working drawing.Making hole/sleeves for Gas pipe as per drawing.Rate should include chasing walls, floors to embed vertical supports and counter top using CM 1:2 including making cutout for for kitchen sink, core cutting for pillar cock, bottle trap etc. complete as per directions & instructions of the Architect. Basic rate of stone is Rs.150 / Sq.ft |
| 56 | Thin Profile Single leaf Glass Door: Supply & Installation of Modular Aluminium Glass door frame of Kubikor equivalent make 45mm System, Using KOPS 001 & KOPS DF 103 ( 45mm x 25mm) for Glass door frameDoorframe Dimension – 45mm x 25mm. Finish – SILVER finish / Powder coating as per approved sample by Architect 10mm thk. clear thoughened Glass KUBIK Glass Hinge , HAFELE Open Door closer with saddel plate , KUBIK Mortiselock with handle , KUBIK Door stoperItem includes all necessary fitting/ fixing,fixtures of approved make complete as per specification, drawing, approval and instructions of the Architect/Client. Rate shall be inclusive of all material loading unloading at all height and all floor. Sample mock shall be approved from Architect/Client. |
| 57 | Single Leaf Flush Door finish with laminate: Providing and fixing in position 40 mm thick BWP grade single leaf flush doors of approved make and finished withboth side 1 mm thickVNR laminate as approved sample, Hardware system as per approved make & Sample (Hinges, Mortise lock with 3 pair key, Door stopper, door closer ). Door closer and mortise lock of Dorma/Geze/Haffle as per approved make by Architect. Hinges, Door stopper and other accessories of Kich/Ozone/Inox as per approved make by architect. work complete including all type of hardware, fittings , fixturesas per instruction of Client/ Architect etc complete as per detailed drawings and specifications. sample mock shall be approved from Architect/Client. Equivalent to VNR Series Laminate. |
| 58 | Single Leaf Flush Door finish with laminate (Toilet door):Providing and fixing in position 40 mm thick BWP grade single leaf flush doors of approved make and finished withboth side 1 mm thickVNR laminate as approved sample, Hardware system as per approved make & Sample (Hinges, Mortise lock, Door stopper, door closer ). Door closer and mortise lock of Dorma/Geze/Haffle as per approved make by Architect. Hinges, Door stopper and other accessories of Kich/Ozone/Inox as per approved make by architect. work complete including all type of hardware, fittings , fixturesas per instruction of Client/ Architect etc complete as per detailed drawings and specifications. sample mock shall be approved from Architect/Client. Equivalent to VNR Series Laminate. |
| 59 | Handicap Toilet Door : Providing and fixing in position 40 mm thick BWP grade single leaf flush doors of approved make and finished withboth side 1 mm thickVNR laminate as approved sample, Hardware system as per approved make & Sample (Hinges,Mortise lock , Horizontal grab bar, Door stopper, door closer). Door closer and mortise lock of Dorma/Geze/Haffle as per approved make by Architect. Hinges, Door stopper and other accessories of Kich/Ozone/Inox as per approved make by architect. work complete including all type of hardware, fittings , fixturesas per instruction of Client/ Architect etc complete as per detailed drawings and specifications. sample mock shall be approved from Architect/Client. Equivalent to VNR Series Laminate. |
| 60 | Double leaf Flush Door with glass view panel and finish with laminate : Providing and fixing in position 40 mm thick BWP grade single or double leaf flush doors of approved make and finished with both side 1 mm thick VNR laminate as approved sample, with glass view panel,8mm thick clearglass view panel, Hardware system as per approved make & sample. (Hinges,Mortise lock , Horizontal grab bar, Door stopper, door closer). Door closer and mortise lock of Dorma/Geze/Haffle as per approved make by Architect. Hinges, Door stopper and other accessories of Kich/Ozone/Inox as per approved make by architect. work complete including all type of hardware, fittings , fixtures ,as per instruction of Client/ Architect etc complete as per detailed drawings and specifications. sample mock shall be approved from Architect/Client. Equivalent to VNR Series Laminate. |
| 61 | Single leaf Flush Door with glass view panel and finish with laminate : \" -----Do----------\" as per above specification for complete work. |
| 62 | WPC board shutter with laminate finish (Duct area): Providing and fixing in position 12 mm thick WPC shutter & partition of approved make with VNR laminate finish as approved, shutter fixed with floorandabove pivot of approved make, pivot cover plate, safety measures , lock& handle etcfixtures of approved make list with all necessary fittings etc. aluminium frame as per required sizeComplete as per detailed drawings and specifications. |
| 63 | Sliding window :(Domal series) Supply & Fixing of Aluminium sliding window with powder coated as per by approved make & sampleby architect/EIC.Shutter section:27 x 65 x 1.54 mm Glass : 5 mm thick reflective glass of saint gobain or approved make list including concealed lock,albose , other necessary fixtures and fastening ,PVDF rollers , EPDN gasket, silicon sealent etc. complete as per detailed drawings, mock sample and specifications. |
| 64 | Fix glass :(Domal 27 mm series) Supply & Fixing of Fixed glasswindow with powder coated as per by approved make & sampleby architect/EIC.frame section:40 x 89 x 1.5 mm Glass : 5 mm thick cleaver reflectiive glass of saint gobain or approved make list including necessary fixtures and fastening , EPDN gasket, silicon sealent etc. complete as per detailed drawings, mock sample and specifications. |
| 65 | Ventilation with provision of Exhaust fan : Supply & Fixing of Ventilation with exhaust fanwith powder coated as per by approved make & sampleby architect/EIC.frame section:45 x 45x 1.5 mm Glass : 5 mm thick Forsted toughened glass of saint gobain or approved make list including necessary fixtures and fastening , EPDN gasket, silicon sealent etc. complete as per detailed drawings, mock sample and specifications. |
| 66 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved anticorrosive paint all complete. Fixed to steel windows by welding |
| 67 | EWC: Common toilet Providing and fixing wash down water closet(European type W.C. pan)as per approved make of selection & shade withseat cover,P OR S Trap M.S. or G.I bracket ,CP brass hinges and rubber buffers and Jointing the trap with soil pipe in cement mortar : 1:1 (1 cement : 1 fine sand)includingcutting and making good the walls and floors where requiredwith all labour and materials.All works to be carried out as per instructions and direction of Engineer-in-charge. Model equivalent - Jaquar- ECS- WHT-955SPP with Accessories Set. |
| 68 | Flush Valve :Providing and fixing Meropole Flush valve ofas per approved make list . Work complete including all type of finishing. Model Equivalent toJaquar FLV-CHR-1093N |
| 69 | Health faucet: Providing and fixing8mm dia. Health faucet as perapproved make listwith flexiblepipe of 1.2mt. length and holding stands complete.Work complete including all type of finishing. Model Equivalent to Jaquar ALD-CHR-573 |
| 70 | Toilet Paper Holder: Providing and fixing Towel ringof as perapproved make of selection or as directed by EIC.Jaquar : ACN-CHR-1151N |
| 71 | Providing and fixing 15mm dia two way Bib cock ofas perapproved make of selection.Model Equivalent toFLR-CHR-5041N |
| 72 | Wash Basin :Providing and fixing under counter Wash Basin includingfittings and waste coupling and fixing on wash basin counter bytile adhesive of approved make.Work complete including all type of finishing. Model Equivalent toJaquar FNSWHT- 40701 + ALD-CHR-705 |
| 73 | Providing and fixing15mm dia. Angular Stop Cock with flangeas per approved make list and work complete including all type of accessories . Model equivalent to Jaquar EKO-CHR-33053 |
| 74 | Providing and fixingPillar cockas per approved make list and work complete including all type of accessories . Model equivalent to JaquarPRS- CHR-043 |
| 75 | Urinal : Providing and fixingUrinal with flush valve with wall flange as per approvedmakelist , with necessary coupling of approved makefor wash basin & sink.Work complete including all type of finishing. Model Equivalent to JaquarURS- WHT-13253N + PRS-CHR-073 |
| 76 | Urinal partition: Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 77 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Nirali : Grace Plain- 510MM X 432MM |
| 78 | Providing and fixing Sink Cock with regular spout with wall flange as per approved make list and work complete including all type of accessories . Model equivalent to Jaquar FLR-CHR-5347N |
| 79 | Providing and fixing CP Brass 32mm size Bottle trap with 300mm & 190mm long wall connection pipes & wall flange of approved quality & make and as per the direction of Engineer-in-charge. with necessary coupling for wash basin & sink.Model equivalent to Jaquar ALDCHR-773M L300X190 |
| 80 | Soap Dispensor : Providing and fixing liquid soap Dispensor of best quality. Complete as per directed by architect and engineer in charge. Euronics code Manual Soap Dispenser (1000ml) ES43 |
| 81 | Hand Dryer: Providing and Fixing Electrical hand dryer, fully automatic type , cover shall be fabricated in ABS material finished, the unit shall deliver of hot air and electrical rating shall be 240 V / 1 phase / 50 cycles. Complete as per directed by architect and engineer in charge. Euronics code : Euronics of EH270N |
| 82 | Providing and fixing ofWashroom Panel/Recessed/S.Steel (2in1,Paper Dispenser / Waste Receptacle) - Mini,Model no KPD3S of Euronics or approved make list . Work complete including all type of fittings, fixtures, tools, etc complete as per manufacturer specification and drawing. |
| 83 | Providing and fixing ofSanitary Napkin Hygiene Panel (3in1) - For Feminine Washroom : Model noESN03S of Euronics or approved make list . Work complete including all type of fittings, fixtures, tools, etc complete as per manufacturer specification and drawing. |
| 84 | Providing and fixing Grab bar vartical swing as per approved make list and work complete including all type of accessories . Model equivalent to Jaquar WAC-SAPBG0800CS |
| 85 | Providing and fixing Grab bar 692mm long as per approved make list and work complete including all type of accessories . Model equivalent to Jaquar WAC-SAPBR0600CS |
| 86 | Providing and fixing Mirror with aluminium frame in which Aluminium frame with special deep colour anodise 40mm width and 1.3mm thickness and 5mm mirror fitted using high grade silicon. Work complete including all type of tools, tackles, scaffolding, safety measures, loading, unloading, transportation, at all floors, all heights, all levels etc complete as per instruction of Architect/EIC. |
| 87 | Toilet Cubical : Model Type: Greenlam Sturdo Essentia Seren: Thickness of Compact Laminate : 12mm Nos 1 32075 32075 . Door : 600mm*1785mm , Divider Height : 1820mm, Overall height : 1995mm (Including 150mm Ground clearance) Supply & Installation of Toilet Cubicles as per approvedmake & sample byDTA . 12 mm Compact Grade 1.5 mm thick laminateBoard of the approved shade by DTA . Accessories for cubicles.1. Aluminum “U” Section witha) Aluminum U Channel b) Nylon Gravity hinges c) Nylon Coat Hook d) Nylon Adjustable Leg e) Nylon Door Knob f) Nylon Thumb Turm Indicator g) Aluminium Door Stopper Channel h) Aluminium Top Raile) Screws, Wall Plugs & Noise Tape Etc. Work complete including all type of fittings, fixtures, tools, etc complete as per manufacturer specification and drawing. |
| 88 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 75 mm outlet: Sand cast iron S&S as per IS: 3989 |
| 89 | ACP Clading Type 1: Model Equivalent to Viva Composite Panel Lustre Series - VA 6001:Panel Thickness : 4MM, Coil Thickness : 0.25MM, Coating : PVDF/FEVE, : Designing, framingtesting, installing and fixing in position Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. includinga) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 4mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, dowcorning weather silicone sealant (789), backer rods etc.c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing. The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field testsaluminium composite panel cladding, cleaning and protection of thealuminium composite panel cladding till the handing over of the building for occupation.The Contractor shall provide aluminium composite panel cladding, having all the performance characteristics all complete, as per thedrawings, as per item description, as specified, as per the approved shop drawings and as directed by the DTA /Engineer. However, for the purpose of payment, only the actual area on the external face ( L x d)of the Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. Basealuminium frame for ACP cladding is inclusiveitem as mentioned above. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles, scaffolding , adhesives consumable hardware & required accessories, grooves etc of approved make for all floors, all heights, all levels and all places within campus. Contractor shall do all the needful and shall fulfill DTA\"s design intent. No additional claims will be entertained for this. Contactor shall providestability certificate for the work. Rate inclusive of shop drawing. |
| 90 | Puf Roofing sheet: Design, supply, erection and Installation of PUF Insulated Pre- Fabricated Flush Paneling for wall and Roof (Inner Skin & Outer Skin GI Pre- Coated sheet) along with the bottom channel runners to hold these panels of Thickness of 80 mm modular panel as pre site requirement with Polyurethane Foam of density not less than 40 kg/m3 as insulating material, made up of pre - painted PPGI sheet both side (0.50 mm hickness) with polyster coat of 30 micron over a primre coat of 30 micron over a primer coat of 5 micron Silicone Sealed junctions.Roof panel: 80mm thickness roof panel, 0.5mm PPGI sheet both side, Density: 40kg/m3, Supply width: 1060mm, Installation Accessory: 1). C-Channel (Size: 40*82*40) 0.5/0.8mm, 2). L-Inner (Size: 50*50) 0.5/0.8mm, 3). L-Outer (Size: 50*100) 0.5/0.8mm, 4). L-Outer (Size: 100*100) 0.5/0.8mm, 5). C-Side Cap (Size: 50*110*50) 0.5/0.8mm, 6). Self Tapping Screws With Metal Washer (Coroshield)Size: 12 x 150mm (Screw), Size: 19mm (Aluminum Bonded Washer), 7). Silicon Sealet (Make :Maccoy Soudal) 1box = 24nos, 8). Anchor Fastner (Make: HILTI) Size: M8*75mm, 9). Puf Revet, 10). Butyal Tape, 11). Plain TOP Ridge (Size: 300*300mm), 12). Plain Bottom Ridge (Size: 250*250mm), 13). Gutter (Size: 50*200*250*310*300mm).,including InstallationallMaterial Supply, Installation, Including Freight, Loading-Unloading Charges. Work complete including all type of material, fittings, fixtures, Finish, loading, unloading, transporation, all leads, accessories, sample mockup, all floor, all levels, all heights, etc. complete as per drawings, specifications & instruction of Client/EIC.Documents to be submitted: Installation & fabrication drawings, roof design analysis report, 3D Model, Stability certificate, Material Test Certificates. |
| 91 | Fabricated : Design, Fabrication & erection of steelstructure as perdrawings including materials, consisting of plates, rolled steel joists, channels, angles, chequered plates etc and also rectangular / square hollow steel sections, insert plates in RCC/Brickwork, anchor bolts for steel structure, sleeve pipes, anchor nuts, washers etc, straightening of raw steel if required, fabrication of steel structures with primer and minimum two coats of anti corrosive paintincluding preparation of supplementary sketches and detailed bill of materials supply of bolts, nuts, washers, shims, packs, putty. gas, welding electrodes and all other consumables, as required and carrying out surface preparation all complete. The scope includes loading, transportation ,unloading and delivery and erection site of all fabricated structures,, alignment and welding of all structures true to line, level, plumb and dimension, including rectification if any, splicing, site assembly all as per technical specifications and drawings, ,all complete. Contactor shall providestability certificate for thefabrication structure. Rate inclusive of shop drawing. |
| 92 | LIFT01 : 08 PASSENGER, 1.0 MPS, G+1, GEARLESS, MACHINE, MRL TYPE, AUTOMATIC, LIFT CAR , AND ALL DOOR IN S.S FINISH (TECHNO INDUSTRIES /SCHINDLER/OTIS)Supply, Installation, Testing, & Commissioning of Passenger lift as per approved make, shop drawing & sample by Architect / Client. work complete including all type of scaffolding , loading , unloading , transportation, fittings, fixtures , all type of safety measures, equipment , at all floor, all levels etc. complete as per shop drawings and specifications. Sample mock & Shop drawing shall be approved from Architect/ Client. No extra charges will be paid for any scaffolding required for installation of lifts works. The intending bidder should visit the site prior to the bidding submission. Rate shall be quoted only after by initial site inspection further no discrepancy will be allowed for whatsoever reason. As per attached technical specification data sheet in tender documents. Liasioning for all statutory approvals pertaining to Lift Installation with certification from Govt.Authority for Licensee for operation of Lift at Site with all clearance shall be in scope of Contractor . Extra charges pertaining to liasioning / licence & third party certification & Inspectionshall be in scope of Client. • TYPE-1 LOAD – KGS / PASSENGER : 544 KG / 08 PASSENGER ELEVATOR AUTOMATIC 1 No., • TYPE OF LIFT : MACHINE ROOM LESS (MRL), • SPEED – MPS : 1.0, • TRAVEL FLOOR, RISE : G + 1 RISE: 6.5 (approx.) MTRS, • FLOOR MARKING : 0,1, • OVER HEAD REQUIRE (MIN) MM / PIT : 5400 / 1600, • STOPS & OPENINGS (MAX) : 02 STOPS 02 OPENINGS, • (G. FL. ENTERY, 1ST FLOOR RIGHT SIDE OPENING) • POWER SUPPLY : 415 VOLTS, 3 PHASE 50 HERTZ ALTERNATING CURRENT, • MACHINE TYPE : GEARLESS PERMANENT MAGNET SYNCHRONISE MOTOR (PMSM), • CONTROL : MICROPROCESSOR BASED WITH V3F DRIVE, • OPERATION : FULL COLLECTIVE SIMPLEX, • CAR SIZE (W X D) –mm : ABOUT 1200 MM wide X 1200 MM deep, • HOISTWAY AVAILABLE (W X D) : ABOUT 1800 MM wide X 1800 MM deep, • CAR ENCLOSURE : S.S HAIRLINE FINISH, • CAR PANELS : S.S HAIRLINE FINISH, • FALSE CEILING TYPE : DESIGN-01, • FLOORING : Vinyl flooring, • CAR ENTRANCE : PROTECTED BY S.S CENTER OPENING DOOR, • SIZE (W X H)-mm : CLEAR OPENING ABOUT 800 MM X 2000 MM HIGH, • HOISTWAY ENTRANCES : PROTECTED BY S.S CENTER OPENING DOOR, • SIZE (W X H) – mm : CLEAR OPENING ABOUT 800 MM X 2000 MM HIGH, • DOOR OPERATION : AUTOMATIC, • SIGNALS AND OTHER DETAILS : LOP and COP – Galaxy type Dot Matrix, • Battery Operated Emergency Light and Alarm, • Press and speak Phone in Car and GF, Cabin Fan, LED Light in Ceiling, • Voice Announcement, Automatic Rescue Device (ARD), Overload, • FACE PLATE FINISH : STAINLESS STEEL, • FACE PLATE SHAPE : RECTANGULAR, |
| 93 | Interior work |
| 94 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge MR grade board |
| 95 | Calcium silicate grid ceiling : Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 96 | Metal grid ceiling : Providing & fixing ceiling as per approved make list : Galvanize Steel Sheet 585 x 585mm / 1185 x 585mm are made from 0.5 mm TCT Galvanized Steel as per IS-513 coil / powder coated on a continuous paint line with flange on each end, which lay on exposed \"T\" grid. tiles shall be easily removed without the aid of special tools. Paint Detail: Coil coated panel shall be chromatized for maximum bond between metal and paint, enamelled twice under high temperature, one side with full primer and finish coat, the other side (Inner side) with a primer coating and skin coat on continuous paint line or Powder coated panel shall be 50 microns thick on exposed surface. Panel surface shall be 585 x 585mm / 1185 x 585mm for 15mm T grid (type B). Installation: To comprise, Main runners spaced at 1200mm centers securely fixed to the slab / truss by means of roll plug and 4mm dia. GI rod at 1200mm maximum centers and not more than 150mm from spliced joint. the last hangers at the end of each main runner should not be greater than 600mm from the adjacent wall. 1200mm cross Tee & 600mm cross Tee to be interlocked between two main Tees to form frid of 600x600mm. panels are than placed individually on the 600 x 600mm exposed grid framework created by Tees. Edge profile: Edge profile shall be L-shaped, roll formed out of 0.5mm Galvanized steel strips with coil coating or powder coating in standard colours.Rate shall inclusive cost of making of all cutouts for light fixtures, gadgets, gizmo, pelmets, grooves, beads and also provide support/template where ever required.The rate shall be in sq.mt for all floors and at all heights including all costs . |
| 97 | Wooden ceiling finish with Laminate : Providing and fixing IS 710 12 mm thick Marine plywood false ceiling as per drawing ,instruction , sample approved& complete with Aluminium anodised section size 50x50x1.5 mm & 25x50x1.5 mm frame work. the frame work fixed as per drawing @ 600 mm c/c. finish with 1 mm thick VNR series Laminate.Rate shall inclusivecost of making of all cutouts for light fixtures, gadgets, gizmo, pelmets, grooves, beads and also provide support/ template where ever required.The rate shall be in sq.mt for all floors and at all heights including all costs . (or a sample mock of 5 Sqm minimum of the frame work and ceiling) shall be approved from Architect.5mm Groove shall be provided at the junction of the false ceiling & the wall. ( considering all levels with require all Framingwork and fitiing from RCC slab to false ceiling level) Equivalent to VNR Series Laminate. |
| 98 | Accoustic ceiling : SITC9mm thick acoustical panel with using framing and then fixing 12.5mm perforated board with the help of screw and using rock wool of 50kg density and 50MM thick between framing and perforated sheet then Fixing Ecotone make Marco polyester fiber acoustic paneling with the specification of 9MM thick having density of 1.90kg/m2 with NRC value of 0.80 surface matt finish which is fixed with solution SR505 as required. The panel should have euro class BASTME84-13 fire rating. The color shade of Panel as approved by Architect. Work Inclusive of Cutting as per detailed drawing and instruction of Architect.Work complete as per the Detailed Drawing, & instruction of EIC. Rate shall be inclusive of all materials, loading, unloading, transportation, placing at all floors and for all leads, polishing and all accessories as described in item description.Rate shall inclusivecost of making of all cutouts for light fixtures, gadgets, gizmo, pelmets, grooves, beads and also provide support/template where ever required.The rate shall be in sq.mt for all floors and at all heights including all costs material and fittings, scaffolding.make list -Senses akustik , woven image , fliz felt.Including surface preparation, Including cost of all type of tools, tackles, all labour, scaffolding, transportation, cleaning, at all floor, all level, all depth, all Height, all lead and lift etc. etc.work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC. |
| 99 | Full Height Partition Gypsum Partition :1 hr fire rated 122mm thick double layered dry wall partition : Providing & Fixing 122.0mm thick Gypwall Classic partition consist of GypSerra® (“Patented in India (325062)”) Metal framework partition having maximum reachable height of 4600mm satisfying L/240 criterion at 200Pa, possessing fire rating of 60mins, tested in accordance to BS-476 Part 20 & 22 & sound insulation (Rw) of 50dB, tested in accordance to ISO 10140-2/ASTM E90 & spectrum adaption term as per ISO 717-1, having U-value of 0.39W/m²K & Severe duty rating as per BS 5234 part 2. Partition comprises of double layer, tapered edge Gypsum Board, certified GreenPro by CII & strategic location of manufacturing plants results in lower carbon emissions. Partition includes inner layer of 12.5mm thick Gypboard®Plain ISI marked, conforming to IS 2095 Part 1:2011, having flexural strength – {Longitudinal > 500N & transverse > 180N} & outer layer of 12.5mm thick Gyproc®Fireline conforming to IS 2095 PART1 :2011 / EN520:2004 - TYPE-F, ASTM C1396-TYPE X, having flexural strength – {Longitudinal > 550N & transverse > 210N} on either side of the framing.GypSerra® Metal frame work, designed in compliance with BS EN 14195 & manufactured using CR1 Grade Steel as per IS 513, having yield stress of 300MPa & tensile strength of 340MPa with surface finish of AZ150 as per IS 15961/AS 1397 & tested for 500hrs of salt spray test as per ASTM B117, includes 70x34x36x0.5mm GypSerra® C-Stud with lip of 6.5mm and H-cutout on web enabling the services to pass, having moment of inertia 61909mm4 about major axis, positioned at 610mm c/c in 72x32x32x0.5mm GypSerra® Floor Channel & 72x32x32x0.5mm GypSerra® Ceiling Channel with flanges bend at 5° acute angle. Floor & Ceiling Channel is anchored with Gyproc® Rawl plug Ø8x45mm having Pull Out strength of 6.8KN or Nail**, fixed at 600mm c/c in zig zag manner. 70x40x40x0.5mm GypSerra® Noggin Channel to be placed between the studs, behind the horizontal board joint. Inner & Outer layer of Gyproc® Boards to be Screw fixed with Gyproc®Drywall Screw of 25mm with 12nos per m2 & 35mm with 24nos per m2 at spacing of 600mm & 300mm respectively. 50mm Glasswool of density 20kg/m3 shall be placed in Metal framework with the help of holding Clip. Edges & joints to be finished with Gyproc® Pro-Fill JC conforming to ASTM C475 & Gyproc®Paper tape. Periphery & cut-outs of the partition to be treated with suitable Fire & Acoustic Sealant. All the performance test are carried out at NABL accredited/ government approved lab.Vendor to submit MTC.Certification can be issued if installation is done as per Gyproc methodology & supervision.Rate shallinclude cost of making of all cut-outs for light fixtures, switchboards gadgets, gizmo, pelmets, grooves, beads and also provide support/template where ever required & For door frame fixing, storages, shelves, paneling etc extra Wooden members to be used shall be of CP teak wood only. Including skirting /MDF board/wooden skirting cut out as per EIC instruction at siteThe rate shall be in sq.mt for all floors and at all heights including all costs. including ply base for fixing of TV or Overhead storage wherever required, The rates are also inclusive of necessary scaffolding, tools, tackles,, safety measures , Internal partial support (between two sturd) at 7\" height.The shop drawing (or asample mock of 5 Sqm minimum of the frame work and partition) shall be approved from EIC and Architect. All exposed corner shall be covered with perforated angle as per manufacturer\"s specifications or as directed by EIC. |
| 100 | Thin Profile Glass Partition : Providing & Fixing ofSTL45 ie.Single glazed modular system consist of Aluminium section of 25*45*2.5 mm thick. All sections duly Powder coated/anodised with 6063-T6 grade and required accessories ie glass to glass aluminium I sections, T section & 90 degree sections & Glass packing to adjust the floor level. Ceiling profile, Floor profile and wall profile are 25 mm visible face and 45 mm wide with 10mm toughen glass as per approved make& insertion of Thermoplastic gasket to adhere the glass firm & airtight.The sound reduction Value is from 32 to 35 Db.With 6 mm Groove inbuilt in system to accomodate the carpet & the uneven surfaces.Work including horizontal thin profile member at lintel lvl. as per drawing. Accessories/Hardware: neutral cure glazed& metal silicon sealant of approved make on the periphery of the glass & woodetc.work inclusive of above ceiling solid partition frameworkas per drawing. Contractor shall take care noise for transformation one Area to another area. Partition ht will be measured from finish floor to false ceiling level only. The rate shall be in sq.mt for all floors and at all heights including all costs. Glasswidth size shall be as per sugestion by EIC.Work complete including all type of material, fittings, fixtures, Finish, loading, unloading, transporation, all leads, accessories, safety measures, sample mockup, all floor, all levels, all heights etc complete as per detailed drawings, specifications & instruction of Client/EIC. |
| 101 | Frosted sparkling glass film (Colour film) : Providing and fixing frosted glass film of approved make Translucent, cast PVC, self-adhesive vinyl, special CRYSTAL-effect film to reproduce Sand-blasting effect on glass with customised designs. MCS warranty of 3 (if exposed to direct sunlight) to 10yrs (indoors) must be endorsed by manufacturer. Rate shall be inclusive plotter cutting design as per Architect/Client suggestion. Contractor shall provide shop drawing for approval of Architect/Client.work complete incuding all type of tools, tackles, scaffolding etc complete as per suggestion of Architect/Client. If in case any application finishing will not as per satisfaction contractor shall remove all film at their cost. Contractor shall do a sample mock of 5 Sqm minimum of glass film), shall be approved from Architect/Client. |
| 102 | Laminate paneling: Providing & fixing 12mm thick fire retardant marine plywood as per IS 710:2010 and IS 5509:2000 fixed on frame work finish with 1 mm thick laminate.The frame work shall be made from square hollow aluminium anodised section size of 50x50x1.5 mm & 25x50x1.5 mm of approved make conforming to IS code.The framework shall be fixed as per drawing vertically @ 600 mm c/c & horizontal 1200 mm c/c horizontally.All ply/wooden shall be treated with anti- termite treatment .Measurements for paneling work to be recorded upto finished false ceiling level only irrespective of aluminium frame work, which shall be provided from gr.level to RCC slab / beams soffit level.Rates shall also be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights /air-conditioners ,grills, diffusers etc & providing additional sections for strengthening around the openings/cutouts additional support for fixing of patch fittings for doors, making grooves between wall & board, in filled with termite treated wooden members if required or as per drawing /instruction of EIC. and no extra payment shall be considered for additional sections provided.All curved surfaces, recesses, waffles shall be part of the paneling including openable shutter wherever required area and finished with the same material.Work complete including all type of material,CNC , Engraving,fittings, fixtures, Finish, loading, unloading, transportation,all leads, accessories, groove,adhesive ,tape, headless nails, sample mockup, all floor , all levels, all heightsetc complete as per detailed drawings ,specifications & instruction of Client/EIC. only the clear elevation area shall be measured andpaid. sample mock shall be approved from Architect/Client. Equivalent to VNR Series Laminate. |
| 103 | Lacquered glass / Coloured glass Panelling :\" ------Do------------\" as per above item specification for complete work . using 4mm thickcolouredmagnetic glass / Coloured glass for panelling work, as per approved by Architect/Client. The rate shall be for all floors, at all heights, all shapes including all costs. |
| 104 | Accoustic Panelling : 12 mm thick Board -Providing and fixing wall acoustical panelling with using CS55 and IC91 framing directly to the wall and then fixing 12.5mm perforated board with the help of screw and using rockwool of 50kg density and 50MM thick between framing and perforated sheet then Fixing Ecotone make Marco polyester fiber acoustic wallpaneling with the specification of 9MM thick having density of1.90kg/m2 with NRC value of 0.80 surface matt finish which is fixed with solution SR505 asrequired. The panel should have euro class BASTME84-13 fire rating. The color shade of Panel as approved by Architect. Including all accessories, material & labor complete as directed by Engineer.Including surface preparation, Including cost of all type of tools, tackles, all labour, scaffolding, transportation, cleaning, at all floor, all level, all depth, all Height, all lead and lift etc.etc.work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC. Only the clear elevation area shall be measured and paid. |
| 105 | Gypsum panelling: The M/F wall lining includes 12.5mm Gyproc® Quattro Gypsum Board, screw fixed with drywall screws of 25mm at 300mm centers to one side of 45X18X0.5mm Gypliner ceiling channel (0.5mm thick having 18mm flange each made of GI Steel) placed at 600mm center to center in 195X29.5X0.9mm fixing bracket at 900mm c/c with 25X25X0.5mm Gypliner angle at bottom and top of the channel such a manner that joints staggered to avoid leakage through joints. Fixing strip of 75X0.5mm should be installed at horizontal joint of boarding. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound and Joint Paper tape. 50mm Glasswool of density 20kg/m3 should be placed in metal frame.Necessary fabrication with anticorrosive paint work , scaffolding, anchor fasting , bolting HILTI or equivalent make with testing certified in scope of contractor)Rate shallinclude cost of making of all cut-outs for light fixtures, switchboards gadgets, gizmo, pelmets, grooves, beadscut out as per EIC instruction at siteThe rate shall be in sq.mt for all floors and at all heights including all costs. The shop drawing (or asample mock of 5 Sqm minimum of the frame work and partition) shall be approved from EIC and Architect. Panelling item including openable shutter wherever required area and finish with the same material.Only the clear elevation areashall be measured andpaid. |
| 106 | Digital Artwork: Providing and Fixing of PANKO Digital Artwork Custom Printed onDurable Polymeric Vinyl Media with Protective Matt Overlaminate,Printed on HP Latex as approved by Architect, suitable for Direct Application on POP finish, ceilings, elevator doors, partitions, pillars,aluminum cladding etc.Work complete includingall necessary fittings ,Design approval from architect, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. Basic rate of wallpaper is Rs. 330 / Sq.ft |
| 107 | Canvas Artwork :Providing and Fixing of PANKO PVC Canvas Artwork Custom Printedon 160GSM Media, Printed on HP Latex 700 with 600 dpi to produce saturated colours as approved by Architect.Work complete includingall necessary fittings ,Design approval from architect, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. Basic rate of wallpaper is Rs. 300 / Sq.ft |
| 108 | Soft Board : Providing and fixing on wall 12mm thick approved quality soft board with cottoncloth/fabric of approved make and shade on 12mm thick IS 710ply 50 mm th approved Glass wool sheet with PVC grip , as approved sample and as directed by EIC. The work shall be measured & paid in Sqm. for all floors, all level and at all heights including all costs .Only the clear elevation area of the cloth/fabric shall be measured and paid. All the work complete as per the detailed drawing , mockup sampleand instruction of Architect/EIC.Basic rateof cotton cloth /fabric for 54\" wide shall be Rs. 200/Rmt. |
| 109 | Reception Table : @2500 x 750 x 1050 mmProviding and fixing Reception table unit consist main table with pedestal unit with all necessary accessories keyboard,CPU stand , cable manager, etc with all required necessary accessories.Table Front panel top: 15-18mm thick simpolo stone envelope with ply structure finish &1 mm thick Laminate finish. work complete as per detail drawingWorking Desk Top: 25 mm thick top made from 303BWR ply with laminate finish.Verticle support: As per detail drawing and reference image made from 25 mm thickIS 303 BWR ply with Laminate finish. providing and fixing as per requirement of socket and quantity Pop up tabletop electrical WIRE MANAGEMENT BOX SS finish. The work shall be done as per the detailed drawing , specifications, sample approved and as directed by the Architect/Client. The rate shall be for complete item inclusive of allmaterial, labour, wastages, necessary tools & tackles, adhesives consumable hardware & required SS 304 gradeardware/accessories, grooves pvc edge banding, etc of approvedmake for all floors, all heights, all levels and all places within campus. Contractor shall do all the needful and shall fulfill Architect\"s design intent. No additional claims will be entertained for this. Equivalent to VNR Series Laminate. Basic rate of stone is 250 / Sq.ft |
| 110 | Three seater Sofa : Supplying and placing Three seater Sofa. as per approved and selection by Architect/ Client.Model Code: As per approved make list.Size - 1850 (L) x 800 mm (B) x 750 mm (H). Three-seater sofa - The top shall be of Upholstery with PU Finish. The sofas are made of Metal base with powder coating , reinforced with supportive addendum in the seat. Engineered wood panels form/support the overall design structure, they synergize with the solid wood to offer unparalleled life to the product. Foam padding of multi-density and varying thicknesses provide cushion for the sofa. PU foam used is made Kurlon foam. plants using Indian Technology capable of producing the high-quality flexible polyurethane foam. It provides unparalleled comfort, ease of use and durability. The foam used is 32 Density for seating areas and 28 Density for backrest. The super soft foam used is in seating areas in 32-35 Density High-resilience (HR) foam which is unique and rarely used by manufacturers. Webbing: Interwoven high tensile elastic bands for optimum comfort and endurance. The work shall be done as per the drawing , specifications, sample approved and as directed by the Architect/EIC. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles,approved make for all floors, all heights, all levels and all places within campus. Contractor shall do all the needful and shall fulfill Architect\"s design intent. No additional claims will be entertained for this.Rate shall inclusive of providingmockup sample for approval of architect. Basic Rate of Fabric : 800 Rmt |
| 111 | Two seater Sofa : Size - 1350 (L) x 800 mm (B) x 750 mm (H). \" ----------------Do-------------------\" as per above specification for complete work.Basic Rate of Fabric : 800 Rmt |
| 112 | Three seater beam seating: (Benz 01 : Waiting Lounge Three Seater Tandem with Cushion )Supply and fixing of Three seater beam seating as per approved make & sample by Architect/ Client. Tandom in 12mm thick moulded shell with veneer duly polished & cushion seat & back.Base in MS powder coating. fitting with Anchor Fasteners. with required accessories Handle,Cup Holder,Cusion,Lable, etc.Work complete including all necessary hardware and fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 113 | Center Table: size of bigger table-2\"6\" Dia and smaller table-2\" DiaProviding & Fixing of CENTER TABLE SET as per detail drawings. Top : 15mm thick solidwood and colour HDF with PU polish Base : Vertical support of Metal legs with powder coatingFinish : Powdercoating on Metal frameSize of bigger table-2\"6\" Dia. Size of smaller table-2\" Dia.Work complete includingall necessary hardware and fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 114 | Corner Table:Size-1\"6\" Dia, \" ------------------Do------------------\" as per above specification for complete work. |
| 115 | Cabin table unit:Table top : 2400 x 900x750 mm ht, Side Unit : 1050x 450x750 mm ht, Back side unit : 2400 x 450 x 750 mmProviding and fixing table unit consist main table, side table with MDU unit with all necessary accessories keyboard, CPU stand ,cable manager, modesty panel etc. with all required necessary accessories. All finishes laminate, powder coating shade shall be approved by architect. Rate shall inclusive of mock up sampleproviding and fixing at site ofunit for approval of architect.Contractor shall submit as per site condition shop drawing for modular furniture layout and send detail drawing for each furniture with 3D and plan section for approval of architect/client.All Table Top:- Table top to be made up of 50 mm thk 303 BWR Ply with VNR laminate finish with specified edge finish as per drawing . Flipopen (450mm x 150mm ) Aluminium Powder coated Flip open with a build Soft closure with Termination box below the table top to accommodate electrical and data socket.Vertical cable riser consider below the table top for wire entry from the floor.Understructure: Work top is supported on MS powder coated leg with MS powder coated Supporting Beams. Modesty Panel MS powder coated perforated modesty panel considered below the table top.Side and Back storage : The structure is made out of303 BWR ply with VNR laminate finish . The shelves , Shuttersare made out of 303 BWR ply with VNR laminate finish. which are adjustable in height. and fitted by hinges. Reverse waterfall handles,normal locking unit and levelers are considered.Prelam Pedestal : 400mm(L)x450mm(D)x650mm(H) The unit to be build prelaminated particle board having 2 drawers +1 filing unit with normal lock and reverse waterfall handle is considered.Hardware make hettich/haffle orequivalent. Providing 3 nos drawerswith profile handle as per selection including locking arrangementCPU standkeyboard- as per selection with approved powder coated . Rate shall inclusive of mock up sample, all materials, loading, unloading, transportation, finishing, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing , mock-up sampleand instruction of Architect/Client. VNR Series Laminate. |
| 116 | Cabin table unit: Table top : 1500 x 750x750 mm ht, Side Unit: 1050x 450x750 mm ht , All Table Top:- Table top to be made up of 25 mmthk 303 BWR ply with VNR laminate with reverse waterfall edge banding.(only user side)\" -----------------Do-------------------\"-as per above specification for complete work. |
| 117 | Cabin Back side storage unit (750 H x 450 D) mm:Storage Comprising from IS 303 BWR 19 mm thick and 12 mm ply, finish with 1 mm thickLaminate finish as per approved make and shade by Architect.Storage top : 35 mm thick post foam top edge finish as per selection and laminate as per selection suede /satin/VNR finish.Solid Shutter : 25 mm thickcomprising from IS 303 BWR ply & finish with 1 mm thick VNR Laminate . Shelf: 19 mm thk IS 303 BWR ply finish with both side approved laminate. Inner area shall be finished with linear laminate.Ledge/Niche comprising from IS 303 BWR ply finish with 1 mm thick Laminate ,required lighting arrangement. The work shall be done as per the detailed drawing , specifications, sample approved and as directed by the Architect/Client. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles, adhesives , grooves ,consumable hardware & required SS 304 grade hardware/accessories , Profile handle ,Wooden frame, monocoat polish , pvc edge banding , of approved make for all floors, all heights, all levels and all places within campus. Contractor shall do all the needful and shall fulfill Architect\"s design intent. No additional claims will be entertained for this. Equivalent to VNR series laminate. |
| 118 | Conference Room Table: Size - Table top 7500L x 1200B x 750H mm:Providing and fixing as per detail shape and size table unit consist tablewith all required necessary accessories.Top 50 mm thick comprising from 15-16 mm thick Artificial stone as per approved sample (reverse bull nose). Base & Vertical support comprising fromIS 303 BWR ply with both side finish with 1 mm thick laminate. Ply box for cable runway comprising from IS 303 BWR ply with both side 1 mm thick laminate finish. Popbox: Flip open-Aluminium SS finish or approved finish open above the table top with build in soft closing mechanism and termination box below table top to accommodate electrical and data sockets Raceway : MS powder coated horizontal raceways considered below table top with intermediate legs provided to allow LAN & electrical cables.Rate inclusive of providing and fixing as per requirement of socket and quantity Pop up tabletop electrical WIRE MANAGEMENT BOX SS finish. The work shall be done as per the detailed drawing , specifications, sample approved and as directed by the Architect/Client. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles, adhesives consumable hardware & required SS 304 grade hardware/accessories, groovespvc edge banding , etc of approved make for all floors, monocoat polish, all heights, all levels and all places within campus. Contractor shall do all the needful and shall fulfill Architect\"s design intent. No additional claims will be entertained for this. Basic Rate of laminate is Rs.45/ Sqft. Basic rate of stone is 250 / Sq.ft |
| 119 | Teacher\"s table / Inquiry Desk: 1200 x 600 x 750 mmEquivalent to code no : Silence 03Table Top : 25mm thick BWR ply with VNR laminte finish with matching PVC edge banding and aluminum flip up with anodized finish.Under structure : 25mm thick pre laminated Gable Ends with Ms Powder coaetd Beams.Modesty : 303 BWR ply with VNR laminateWire management : Powder coated wire tray with switch plate & PVC wire guard for wire managementTwo Drawer Unit : Comprising from 303 BWR ply with VNR laminate with matching PVC edge banding , handle & lock & key.All the exposed edges are with 2mm PVC edge Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding. PVC edge banding are imported from Rehau or Dolken of Germany.Work complete including all necessary hardware and fittings , mock up sample, loading,unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 120 | Workstation : L Shaped : Providing and fixing desk based L shaped workstation of size 1500-1600x600x1050 one side and other side 1500x600x1050 ht ( Ht: 750 mm workstation + 450 mm LacquaredGlass including bracket) at below mentioned locations. Contractor shall submit as per site condition shop drawing for modular furniture layout and send detail drawing for each furniture with 3D and plan section for approval of architect/client The table top-Table top to be made up of 25 mm thk prelaminated MDF/particle board with 2 mm thick matching PVC edge banding Flip open-Aluminium powder coated flip open above the table top with build in soft closing mechanism and termination box below table top to accommodate electrical and data socketsRaceway : MS powder coated horizontal raceways considered below table top with intermediate legs provided to allow LAN & electrical cablesMetal Legs: Metal legs as per selection of shapes & powder coating Modesty panel :Prelaminated MDF/particle board with exposed edges 2 mm th matching PVC edge bandingGlass divders-8 mm th Lacquered glass with 300 mm height fixed with approved bracket / holderRate shall inclusive of mock up sample, all materials, loading, unloading, transportation, inclusive of Vertical / Horizontal ready made raceway for Cables, placing at all floors and for all leads, all accessories as described in item description. As approval of EIC. All the work complete as per the detailed drawing , mock-up sampleand instruction of Architect/EIC. Work complete as per the instruction of EIC. |
| 121 | Workstation :Linear type : 1200mm x 600x 750mm ht.\" -------------------Do---------------------------------as per above specification for complete work . |
| 122 | Lab desk :Linear type : 900mm x 600x 750mm ht. \" -------------------Do---------------------------------as per above specification for complete work . |
| 123 | Pedestal Unit: @400x420X650Comprising fromof 25mm thick exteriorgrade Prelaminated partical board ( PLPB) table top with PVC edge bedding on sides and bottom. The top and drawer facia are sealed with 2mm thick PVC edge. The drawer unit consists of 1 box drawer and 2 file drawer. The sides of Inside drawer box are of PLPB. The drawer box is fitted with telescopic chanel hettich or haffle makefor free movement. The drawer unit is provided with central locking system, where in the three drawer are locked with one key.SS 304 recessed handles are provided for easy opening and closing of drawer.The drawer unit is fitted on castors (optional) for easy mobility. PVC edge banding are imported from Rehau or Dolken of Germany. The complete furniture unit is factory assembled with knock down fittings. Work complete includingall necessary fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 124 | Keyboard with mouse tray : Providing and fixing key board as per approved make. Metal keyboard tray with Outer Dimension of the Keyboard tray is 507 x 245mm made of 1mm thick CRCA as per approved shade powder coating fixing with require all necessary acessories etc complete |
| 125 | CPU stand : Providing and fixing CPU trolly ebco or eqvilant approved make. CPU Trolley base is made of 1.6 mm thck CRCA and the sides are made of 1.2mm thick. The width of the trolley can be varied to accompany various width CPU. The CPU is mounted on lockable castors. |
| 126 | Library Table 6 seater with screen - size : 750 x 600 x 750 mmEquivalent to as per approved brand by Architect/Client.Table Top : Top should be made of 25 mm thick Postform using Exterior grade MDF , 1 mmthick laminates as per approved shades .Edge finish : All side PVC edge Imported banding of Rehau or approved make Glass Divider: Providing & Installing (450mm Height) 12mm thk intermidiate frosted glass divider with necessary SS brackets, fittings & hardware.Base Frame : The understructure ( Horizontal & Vertical support) should be made of Stainless Steel / Mild Steel 40/50 mm square pipe of 1.6 mm thickness of 16g fitted on four.Legs. All the SS components should be properly buffed & all MS components is Duly powder Coated.Fasteners & Bush : Nylon / PP Bushes, Alen key bolts, T. Nuts drilled in the raw ply & riverted for perfect strength witch is Taken from Reputed Manufacturer.Table shall have wire Management system, accessible from the table top on the horizontal surface. Flip top to the flush of work surface.Rate shall be inclusive of all materials, loading, unloading, transportation, placing at all floors and for all leads, polishing and all accessories, SS brackets ,sample mockup etc as described in item description.work complete as per the instruction of Client/EIC. |
| 127 | 4\"ft height storage:450 mm DepthStorage unit top made up of 25 mm thk MDF Exterior grade The top has a post formation round edge finish with both side laminate .Storage body is made of 18mm thick MDF top with exterior grade finish with both side 1 mm th laminate . Shutter finish with both side 1 mm th laminate. The back of the unit is made from 9mm prelaminated board. All the exposed edges are with 2mm PVC edge Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding.Having premium lock with wave key technology and side and hinged shutters are sealed with 2mm thick PVC edge banding.SS 304 recessed handles are provided for easy opening and closing ofshutter. The units are assembled by knock down fittings such as Minifix & Dowels. All the hardware and Hinges are from Enox/Ebco. PVC edge banding are imported from Rehau or Dolken of Germany .Rate shall inclusive of mock up sample, all materials, loading, unloading, transportation, monocoat polish, placing at all floors and for all leads, all accessories as described in item description. As approval of EIC. All the work complete as per the detailed drawing , mockup sampleand instruction of Architect/EIC. Work complete as per the instruction of EIC. Equivalent to VNR series laminate. |
| 128 | Full Height Storagewith LaminateFinish : 450 mm Depth Storage Comprising from IS 303 BWR 19 mm thick and 12 mm ply, finish with 1 mm thickLaminate finish as per approved make and shade by Architect. Solid Shutter : 25 mm thickcomprising from IS 303 BWR ply & finish with 1 mm thick Laminate . Shelf: 19 mm thk IS 303 BWR ply finish with both side approved laminate. Inner area shall be finished with linear laminate. Ledge/Niche comprising from HDF / Lacquered glass finish w,required lighting arrangement.The work shall be done as per the detailed drawing , specifications, sample approved and as directed by the Architect/Client. The rate shall be for complete item inclusive of all material, labour, wastages, necessary tools & tackles, adhesives , grooves ,consumable hardware & required SS 304 grade hardware/accessories , Profile handle, Wooden frame, monocoat polish, pvc edge banding of approved make for all floors, all heights, all levels and all places within campus. Contractor shall do all the needful and shall fulfill Architect\"s design intent. No additional claims will be entertained for this. Equivalent to VNR series laminate. |
| 129 | Glass profile storages : Frame: Frame shall be made of IS 303 BWR grade ply 35mm thick with both side laminate finish as per approved sample.Shutter :4 mm thick clear glassas per approved sample.Shelves : IS 303 BWR grade ply 25 mm thick with both side laminate finish as per approved sample( adjustable shelving system)Equivalent to as perapproved brand by Architect/Client. Back : IS 303 BWR grade ply 19 mm thick with both side laminate finish as per approved sample.Two side Postforming edge and other side2mm PVC edge Imported banding & sealed edges are with 0.8mm thick PVC Imported edge banding.Having premium lock with wave key technologyand side and hinged shutters are sealed with 2mm thick PVC edge banding.SS 304 recessed handles are provided for easy opening and closing ofshutter.The units are assembled by knock down fittings such as Minifix & Dowels. All the hardware and Hinges are from Hettich/Ebco. PVC edge banding are imported from Rehau or Dolken of Germany .Rate shall be inclusive of all materials, loading, unloading, transportation, placing at all floors and for all leads, polishing and all accessorie, sample mockup etcas described in item description.work complete as per the instruction of Client/EIC. |
| 130 | TV unit: Providing and fixing TV ledge unit comprising from MR grade ply with 1 mm thick VNR laminate finish as per approved sample. TV unit consisting 2nos. of Drawer & 1nos. niche.Work complete including all necessary hardware and fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 131 | Console : Providing &fixing Console complete as per drawing/Ref Image. Approx size : 1500 x 400 x 600 mm made fromup of 19 mm thick BWR grade ply & finished of Laminate as perapproved make and shade and solid wooden leg with matt finish monocoat polish as per drawing. Rate shall be inclusive of providing, fixing all necessary brass satin finish nickel plated/ S.S 304 grade (hardware from Hettich like Auto Hinges, handle, Rod locks,Multipurposelock, Rateshallbeinclusiveofinternalshelvesof 19mmthickIS303BWR plyand laminate ,PVC edge beading . All external & internal exposed woodwork to be finished in PU semi gloss paint finishpolishasperspecifieditem\"smanufacturer\"sspecifications.Rateshallinclusiveofprovidingmockup sample for approval of architect. Equivalent to VNR series laminate. |
| 132 | Training room chair : Model equivalent make -to Dx06(c)as per approved sample list.Chair with 12mm thk moulded ply & cushion on seat & back, Frame in .M. S oval pipe of 16g duly powder coated, Half Writing tablet in BSL with edge banding. PU cladding on both side Arms.Work complete includingall necessary fittings ,mock up sample,loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 133 | Head Chair : Model Equivalent to: Mid Back Clasp 02Supply and fixing of chair as per approved make & sample by Architect/ Client. * Back Frame in Moulded Nylon & PP.* PU Moulded Cushion on Seat.* Cushioned Back Lumber Support.* Nylon Mesh in Back with Adjustable Arms with PPPad .* Synchronised single Lock Mechanism.* Chrome Base & Gas Lift.Work complete including all necessary hardware and fittings , mock up sample, loading,unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 134 | Visitor\"s / Workstation chair : Model Equivalent to:Low Back Evo02Supply and fixing of chair as per approved make & sample by Architect/ Client. * Back Frame in Moulded Nylon & PP with Mesh.* PU Moulded Cushion on Seat. * Back Lumber Support.* Nylon Mesh in Back with Adjustable Arms with PP Pad .* Chrome Base.Work complete including all necessary hardware and fittings , mock up sample, loading,unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 135 | Conference/ Meetingroom head chair : Model equivalent toLotus 01 : HighBack Revolving Chair as per approved make list.Chair With frame in MS, PU foam in back & Moulded PU Seat, Chrome Arms with PU cladding & Synchro Mechanism, Chrome base, & Gas Lift.Work complete includingall necessary fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 136 | Conference room chair : Model equivalent toLotus 02 : MidBack Revolving Chairas per approved make list.Chair With frame in MS, PU foam in back & Moulded PU Seat, Chrome Arms with PU cladding & Synchro Mechanism, Chrome base, & Gas Lift.Work complete includingall necessary fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 137 | Library chair : Model equivalent toGoderej Bravo NXT chairas per approved make list.Chair With Mouldedply 12 mm thick in seat & back , PU moulded foam on seat & back ,4 bend PU Arms / T Adujustable Arms ,fix frame in 1\" dia MSpipe of s Shape. Work complete includingall necessary fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 138 | Band room chair : Model Equivalent to- DX 06 Arms chairas per approved make list.Chair with 12mm hot pressed Veener moulded ply with Melaminefinish in back & cushion on seat, Frame in MS Oval Pipe of 16 g, PUcladding Arms on both sides.Work complete includingall necessary fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 139 | Music Stand :Providing & Fixing stand as per approved sample by Architect/Client.Softline Pro Music Stand, Portable & Foldable Professional Notation Stand with Light and Bag, Tabletop Music Book Stand for Guitar, Ukulele, Violin Players (SP-ABSP-FMUS-KIT)Work complete includingall necessary fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 140 | Sloted metal racks: size 900mm x 450mm x 2100mm, Location: Store roomProviding & Fixing of store room metal racks as per detail drawings.Shelf-5, Compatment-4, Shelf Thickness -20G, Angle Thickness -14G, Raw Material GI With Powder CoatedMOC :- TATA/Asian GI, Nut Bolt :-8/16 Zinc Coated, Color:- Gray / IvoryWork complete including all necessary hardware and fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 141 | Roller Blinds : Providing and fixing blinds as perapproved make as per suggested shade & spring drive system with steel ball chain/one touch with speed control action roller blind with end brackets with head rail, components, bottom bar. Fabric : screen classic 3% .Fabric value : 470 Gsm ,Thickness : 0.60 to 0.70 mm Construction: 75 % PVC & 25 % PolysterFabric to be as per approved sample. All the work complete as per the detailed drawing , mockup sampleand instruction of Architect/EIC. All complete as per approval of designer. The mode of Measurement: The size of the blind will be measured from end to end bracket (Left to Right bracket) height will be measured from top of the pelmet to sill bottom level and clear opening size only there will be not extra payment towered overlapping.& mockup sample approved by the Architect/ EIC. |
| 142 | Signages Type 1 : 3D letters with LED : Wall MountedMaterial : 3 mm thick exterior grade premium quality ACP sheet (0 .25 mm foil thickness) & and 3D Embossed virgin acrylic/aluminum letters as per approvedmake and sample by Architect/ Client.Led Light : Rishang(Korea) and SMPS as per approved make and sample by Architect/ Client.The rate shall be for complete item of Designing, providing, fixing & erection, inclusive of all material, labor, wastages, necessary tools & tackles, adhesives, required hardware/accessories, any type of framing work, engraving, required civil work with finishing, LED light .Work complete including all type of material, fittings, fixtures, Finish, loading, unloading, transporation, all leads, accessories, sample mockup, all floor, all levels, all heights, etc complete as per drawings, specifications & instruction of Client/EIC. |
| 143 | Signages : Providing and fixing signages comprisingform 45mm aluminum profile with back side UV printed PC as per instruction of Archiect/EIC. Contractor shall submit mock up sample. |
| 144 | Emergency Signages : Providing and fixing emergency signages of size 300mm x 100mm comprising form 1.5mm thick photoluminescenttap on 3mm thick acrylic sheet as per instruction of Archiect/EIC. Contractor shall submit mock up sample. |
| 145 | Signage\"s : Providing and fixing signages comprisingform 65mm thick backlit fabric box & LED with aluminum framing work as per instruction of Archiect/EIC. Contractor shall submit mock up sample. Work complete including all type of material, fittings, fixtures, Finish, loading, unloading, transporation, all leads, accessories, sample mockup, all floor, all levels, all heights, etc complete as per drawings, specifications & instruction of Client/EIC. |
| 146 | Alluminium Skirting : Providing and Fixing ofAluminium Skirting as per approved make having width of 75 MM X thickness of 2mm made out of 6063 Grade Aluminium alloy dulyanodised as desired in the Ral Colour code decided by the architecthaving neat screw fixed arrangement with Rubber seal over it as per Manufacturers Specification. work complete as per the instruction of Architect. Rate shall inclusive ofmock up sample, all materials, loading, unloading,transportation, placing at all floors and for all leads,all accessories as described in item description. |
| 147 | Writable with magnetic glass board : Providing & fixing 04mm SGG Pristine Tan Glossy Finish writable & Magnetic CEPboard on existing partition/wall as per approvedsample by Architect/Client.work Including cost of all type offittings , accessories , tools, tackles, all labour, scaffolding, transportation, cleaning, at all floor, all level, all depth, all Height, all lead and lift etc. etc.work complete as per the detailed drawing, approved sample, specifications and instruction of Architect/EIC. Sample mock shall be approved from Architect/EIC.Only the clear elevation area shall be measured and paid. |
| 148 | Planter box: Providingmaking, fixing as per detail drawing and required length and depth shall be made from19mm IS 710 BWP ply with both side laminate finish and providing lighting arrangement cutout and fixing as per detail drawing and instruction. Rate shall inclusive all necessary hardware and fitting, ms framing, paint. The work shall be done as per the specifications, sample approved and as directed by the Architect/ Client. Rate shall inclusive of providing mockup sample for approval of Architect/ Client. Rate shall be inclusive of all materials, loading, unloading, transportation, placing at all floors and for all leads, polishing and all accessorie, sample mockup etcas described in item description.work complete as per the instruction of Client/EIC. |
| 149 | Natural plants with poting mix as approved: fycus lyarata, travellars palme, elephant ear, pichardia grandis or similar plants. Work complete including all necessary fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. Basic Rate of Material: Rs. 1500/Nos |
| 150 | Clay Pot/planter box:Providing and fixing of clay pot/plater box ( 3ft length x 1\"ft depth x 1\" ht) as per selection by Architect. Basic Rate of Material: Rs. 1000/Nos |
| 151 | Painting : Providing Wall paitingas per Architects selection . Basic rate of paintingis 1000/- NosWork complete includingall necessary fittings, mock up sample, loading, unloading, transportation, placing at all floors and for all leads, all accessories as described in item description. Work complete as per the detailed drawing and instruction of Architect/Client. |
| 152 | MetalProfile : Providing and fixing of 6 mm thickS.S. T ProfileCopper or as per approved sample by Architectincluding necessary material , adhesive tools , tackles , fittings etc complete .Work complete including all type of tools, tackles, scaffolding ,mock sample, etc complete as per instruction of Architect/EIC. |
| 153 | Plumbing work |
| 154 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.: 15 mm nominal dia Pipes |
| 155 | 20 mm nominal dia Pipes |
| 156 | 25 mm nominal dia Pipes |
| 157 | 32 mm nominal dia Pipes |
| 158 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall: 40 mm nominal dia Pipes |
| 159 | 50 mm nominal dia Pipes |
| 160 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work: 65 mm nominal dia Pipes |
| 161 | 80 mm nominal dia Pipes |
| 162 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 163 | 32 mm nominal bore |
| 164 | 40 mm nominal bore |
| 165 | 50 mm nominal bore |
| 166 | 65 mm nominal bore |
| 167 | 80 mm nominal bore |
| 168 | Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 169 | Supply, Installation, Testing & Commissioning of HDPE 3 layered Tanks. |
| 170 | 100 mm S.C.I. trap with 100 mm inlet and 75 mm outlet |
| 171 | 100 mm S.C.I. trap with 100 mm inlet and 100 mm outlet |
| 172 | S.C.I. gully or nahani grating 100 mm dia |
| 173 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe: 40mm dia |
| 174 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure poluthene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(G)110 mm |
| 175 | Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working pressure polythene pipes of the following outside Dia. Low densidy, complete with special falnge compression type fittings, wall clipsetc. including making good the wall ceiling and floor.(F) 75mm |
| 176 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc.: 75 mm dia |
| 177 | 100 mm dia |
| 178 | Providing & Supplying of Class SN8 structured wall Polythelene piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular corrugated and smooth internal surfaces (Double Wall) for non pressure underground Sewerage & Drainage application as per EN:13476-3 incuding all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores etc. complete (ID Dia). Pipe Dia. ID 150mm |
| 179 | Providing & Supplying of Class SN8 structured wall Polythelene piping systems (Pipe with online/offline coupler and elastomeric sealing ring) with non-smooth External Annular corrugated and smooth internal surfaces (Double Wall) for non pressure underground Sewerage & Drainage application as per EN:13476-3 incuding all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the departmental stores etc. complete (ID Dia). Pipe Dia. ID 200mm |
| 180 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up tohaunches of S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe |
| 181 | 200 mm diameter S.W. pipe |
| 182 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 183 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 184 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 185 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. topslab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 186 | Providing & erecting water cooler having storage capacity 150 Ltr. & cooling capacity 150 Ltr.per hour @ an ambient temp of 450 C. The outlet temp. of the water should drop by 150C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating, coil, thermostats, relay etc.complete with necessary inlet & outlet connection. The body of water cooler will be made from Stainless Steel. |
| 187 | Supplying & erecting 5 stage single reverse osmosis water purification system with M.S. powder coated frame, prefilter housing with \"O\" ring presediment filter GAC filter, carbon filter suitable buster DC pump capacity 80 psi, mention with 40 Osg inline type post carbon filter auto low & high pressure switches with following size of storage tank & LPH capacity & erected as directed with one year comprehensive maintenance guarantee. [C] 50 Ltr / Hr with 250 psi 2 nos booster pump |
| 188 | HYDRO PNEUMATIC SYSTEM FOR DOMESTIC WATER DISTRIBUTIONVariable Speed Hydro-booster System : Compact self contained Hydro-booster system comprising of following : In-line, vertical multistage, centrifugal clear water pumps with SS-304 casing, S.S 304 impellerandSS-304shaft,C.I.BaseCEDcoating&headTEFCmotor(with mechanical seal) Vendor to submit performance curves and technical catalogue of the proposed model for review and information. The job shall include required size of Foot valve, Inlet Pipe, Outlet Pipe, Y Strainer, NRV,Inlet & Outlet Valves, Main Header Header, Pressure Valve,and all required accessories to complete the job.Panel mounted PLC based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a single body or as separate components with pressure sensor transmitter, IP 55 enclosure, diodes to indicatepumpready,pumprunningandfaultcondition.Eachincomerand Outgoing feeder should be capable for protection against Overload, Short Circuit and Phase reversal condition. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. Indication of all type of faults / on-off status. Electronic type low water level controller with LED panel to operate pump (necessary contactsalongwithminimumonePLCoperatedsparecontactsrequired),with probe & all control wiring from Panel to tank to operate the system automatic/manual & shall prevent the pump from dry running.Scope shall also include power and control cable of required size, termination, cable tray from Pump to Control panel etc. complete the job.Pre-charged diaphragm pressure vessel with interchangeable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be as per manufacturer recommendation).Setof accessoriessuch as GIheaders of suction and discharge for (working and standbypumpassembly),controlvalves,nonreturnvalves,pressureswitches, pressure transducers, pressure gauge etc. complete the job.Domestic Water Supply Distribution PUMP:Capacity per pump- 150 LPM1 Set= 1 Nos. Pump (1 Working + 1 Standby - cascade operation)Total Capacity of System: 300 LPMHead - 40 mtLocation- Pump RoomSuction head- Negative Suction |
| 189 | ELECTRICAL |
| 190 | Supply, Installation, Testing & Commissioning of Main LT Panel-DINING HALL as per SLD & Specification. Incomer : 250Amp, 4P, 35KA Microprocessor based MCCB, LSIG Protection : 1 NosIndication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram.Busbar Chamber : 250Amp, 4P, ALUMINIUM Busbar, 35KA.Outgoing :63A FP MCB ,10 KA,C CURVE -12 NOS.40A FP MCB ,10 KA,C CURVE -8 NOS.40A DP MCB ,10 KA,C CURVE -4 NOS. |
| 191 | Supply, Installation, Testing & Commissioning of Main LT Panel-LIBRARY as per SLD & Specification. Incomer : 250Amp, 4P, 35KA Microprocessor based MCCB, LSIG Protection : 1 NosIndication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram.Busbar Chamber : 250Amp, 4P, ALUMINIUM Busbar, 35KA.Outgoing :63A FP MCB ,10 KA,C CURVE -12 NOS.40A FP MCB ,10 KA,C CURVE -8 NOS.40A DP MCB ,10 KA,C CURVE -4 NOS. |
| 192 | Supply, Installation, Testing & Commissioning of Lighting Panel as per SLD & Specification. Incomer : 63Amp, 4P, 10KA MCB : 1 NosIndication Lamp, Multifunction Meter, CT etc. as per Single Line Diagram.Busbar Chamber : 63Amp, 4P, ALUMINIUM Busbar, 15KA.Outgoing :40A FP MCB ,10 KA,C CURVE -12 NOS WITH TIMER SWITCH |
| 193 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mmFRLSPVC insulated copper conductor singlecorecableinsurface/ recessed medium classPVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 194 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single corecable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 195 | Wiring fortwin control light point with 1.5sq.mmFRLSPVC insulated copper conductor single core cable in surface/ recessedmedium class PVC conduit, 2way modularswitch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSPVC insulated copper conductor single core cable etc. as required. |
| 196 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduitas required.: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 197 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 198 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 199 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.: 5/6 amps switch |
| 200 | 2 way 5/6 A Switch |
| 201 | 15/16 A switch |
| 202 | 3 pin 5/6 A socket outlet |
| 203 | 6 pin 15/16 A socket outlet |
| 204 | Telephone socket outlet |
| 205 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.: 1 or 2 Module (75mmX75mm) |
| 206 | 3 Module (100mmX75mm) |
| 207 | 4 Module (125mmX75mm) |
| 208 | 6 Module (200mmX75mm) |
| 209 | 8 Module (125mmX125mm) |
| 210 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. : 1 or 2 Module |
| 211 | 3 Module |
| 212 | 4 Module |
| 213 | 6 Module |
| 214 | 8 Module |
| 215 | Supplyingandfixingmodularblankingplate on the existing modular plate & switch box excluding modular plate as required. |
| 216 | Installing of Exhaust Fan in existing opening, including and making good the connection, damage connection, testing commissioning etc as required. upto 450mm sweep |
| 217 | Extra for fitting of Lowers/shutters complete with frame for exhaust fan of all size. |
| 218 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.: 1 run of cable |
| 219 | Supplyingandfixingfollowingway,singlepoleandneutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, completewithtinnedcopperbusbar,neutralbusbar,earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door |
| 220 | 12 way , Double door |
| 221 | Supplyingandfixingfollowingway,horizontaltypethreepole andneutral,sheetsteel,MCBdistributionboard,415V,on surface/recess,completewithtinnedcopperbusbar,neutral busbar,earthbar,dinbar,interconnections,powderpainted includingearthingetc.asrequired.(Butwithout MCB/RCCB/Isolator)8 way (4 + 24), Double door |
| 222 | Supplyingandfixing5Ato32A rating, 240/415V, 10kA,\"C\"curve,miniaturecircuitbreakersuitableforinductiveloadof followingpolesintheexistingMCB DBcompletewith connections, testing and commissioning etc. as required.: Single pole |
| 223 | Supplyingandfixingsinglepoleblankingplateintheexisting MCB DB complete etc. as required. |
| 224 | Supplying and fixing following rating, double pole, 240 V, isolatorintheexistingMCBDBcompletewithconnections, testing and commissioning etc. as required.: 40 A |
| 225 | 63 A |
| 226 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.: 40 A |
| 227 | 63 A |
| 228 | Supplying and fixing following rating, double pole, (single phase andneutral),240V,residualcurrentcircuitbreaker(RCCB), havingasensitivitycurrent30mAintheexistingMCBDB completewithconnections,testingandcommissioningetc.as required.: 40 A |
| 229 | 63 A |
| 230 | Earthing with copper earth plate 600mm X 600mm X 3mm thickincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 231 | Supplying & erecting in earthpit of minimum bore dia. 225mm sizeapproved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipeshaving Outer pipedia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applicationswith chamber and heavy duty cover (A)(approvedmake OEM has to submit test certificate including value of earth resistance of installation duly stamped and signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B)Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound:- Earthing compound should be capable to retain moisture for long timeNecessary test report must be submitted by Agency. [C] For Electrical Installation covering Transformer Neutrals, Lightningarrester Earthing, A.C.Plant & SensitiveComputer System(likeAutomation,SCADA)i.e. independent Earthinglocated in other than normal soil i.e.Soft Rock,Marshy Soil etc..-Length of Pipe : 3 Mtrs.-Back filling Compound :2 nosBags of 25 Kg. |
| 232 | Supplying and laying 25 mm X 6 mm copper strip at 0.50 metre belowgroundasstripearthelectrode,includingconnection/ terminatingwithnut,bolt,spring,washeretc.asrequired. (Jointing shall be done by overlapping and with 2sets of brass nut bolt & spring washer spaced at 50mm) |
| 233 | Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre belowgroundasstripearthelectrode,includingconnection/ terminatingwithnut,bolt,spring,washeretc.asrequired. (Jointing shall be done by overlapping and with 2sets of brass nut bolt & spring washer spaced at 50mm) |
| 234 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 235 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables(A) 3 1/2core 25 Sq. mm ( 16 Sq. mm 1/2 core) |
| 236 | (B) 3 1/2core 35 Sq. mm ( 16 Sq. mm 1/2 core) |
| 237 | Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables (A) 4 core 16 Sq. mm |
| 238 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / SolidCopperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof followingsize of cables. (C) 4 core 6 Sq. mm |
| 239 | Supplying and making end termination with brass compression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 25 sq. mm (28mm) |
| 240 | 3½ X 35 sq. mm (32mm) |
| 241 | 4 X 16 sq. mm (28mm) |
| 242 | Supplying and installing following size of perforatedHot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenientsections,joinedwithconnectors,suspendedfrom the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 243 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 244 | Supplyingand erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier & Inverter &sealed maintenance free SMF batteries. The charger having operating capacity for input 160-270V AC &inverter having output230V,50 Hz Acwith 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load. (K) 30 KVA3 - phase with 1Hr Backup |
| 245 | Supplyingand erecting approved make online Un-interruptible Power Supply system comprising flat cum-boost charger with IGBT base rectifier & Inverter &sealed maintenance free SMF batteries. The charger having operating capacity for input 160-270V AC &inverter having output230V,50 Hz Acwith 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following power backup.with MS painted batteries stand, 10% Overload capacity for momentary load. (I) 10 KVA3 - phase with 1Hr Backup |
| 246 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. |
| 247 | Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box. |
| 248 | Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing. |
| 249 | Supplying & erectingfan hook box of10 mm M.S. round bar bounded to the RCC bars up to 50mm length each side and pierced through a16 Gauge M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with necessary finishing. |
| 250 | Supplying and erecting approved make oscillating type bracket fan A.C. 23OV. 50cy/s 400/450 mm sweep wall mounted with height adjustment and rotary tilting device complete with guard,flexible Core plug top complete erected with lead wires as directed. |
| 251 | \"Supply Installation Testing Commisioning ofIndoor deep Recessed Round downlight18-21W Recess Mounted Round backlit downlighter with below features 1. Pressure die cast Aluminum alloy housing for better thermal conductivity. 2. PS diffuser for optimum light transmission. Round Version.3. Efficacy of Fixture more then or equal to 85 Lumens /watt Available with 5700K, 4000K & 3000K CCT.4. CRI>80, High efficiencydriver with inbuild surge protection, over voltage protection, short circuit protection and operating at >0.9 PF. <5% THD 5. LED life of more then 35000 Hrs @ L70. Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva |
| 252 | Supply Installation Testing Commisioning ofIndoor Office Lighting 7-9wRecess Mounted Tiltable Spotlight downlighter with below features1.Pressure die cast Aluminum alloy housing for better thermal conductivity. 2. With COb with Lens of 36-40 degree3. Efficacy of Fixture more then or equal to 85 Lumens /watt Available with 5700K, 4000K & 3000K CCT.4. CRI>80, High efficiencydriver with inbuild surge protection, over voltage protection, short circuit protection and operating at >0.9 PF. <5% THD 5. LED life of more then 35000 Hrs @ L70. Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva |
| 253 | Supply Installation Testing Commisioning ofIndoor cove mounted Heavy 18X18mm corner 45degree customized Extruded Aluminium alloy Housing and polycarbonate diffuser profile for continous decorative illuminationAnodised aluminium end caps firmly fixed on the aluminium extrusionSilver anodised finish for elegant look . Efficacy of Fixture >=100 Lumens/Wattsuitable for self adhesive Strips with driver.Wattage should be 12-15w/m. Should have a dotless continuos effect. Should be operated using remote driver of 24V Dc kept at suitable locations for future maintainance.Quantity in metres Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva |
| 254 | Supply Installation Testing Commisioning ofIndoor recess mounted 35mm cut out (35x35mm profile light), Heavy aluminium Extruded Aluminium alloy Housing and polycarbonate diffuser profile for continous decorative illuminationAnodised aluminium end caps firmly fixed on the aluminium extrusionSilver anodised finish for elegant look . Efficacy of Fixture >=100 Lumens/Wattsuitable for self adhesive Strips with driver.Wattage should be 40-55w/m. Should have a dotless continuos effect. Should be operated using remote driver of 24V Dc kept at suitable locations for future maintainance.Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva |
| 255 | \"Supplying, Installation, testing & erectingof Indoor Linear Lighting 34W-38w 1200MM Suspended profile with below featuresExtuded Aluminum alloy housing for better thermal conductivity. Powder coated using Nano technology for longer durability. PS diffuser for optimum light transmission or opiton of Lens Based profile for better task lighting. Option to be selected by Architect / ConsultantEfficacy of Fixture 95 Lumens /wattAvailable with 5700K, 4000K & 3000K CCT. CRI>80High efficiency Mettalicdriver with inbuild surge protection, over voltage protection, short circuit protection and operating at>0.9 PF. <5% THDLED life of 50000 Hrs @ L70. IP20 ProtectionLuminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015.Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva |
| 256 | Supply Installation Testing Commisioning ofIndoor Office Lighting 2x2 Fixture 35-38w with below specifications1. Single Pressure die cast Aluminum alloy housing for better thermal conductivity and extremely low weight . 2. Efficacy of Fixture more then or equal to 85 Lumens /watt Available with 6500K,5700K, 4000K OR 3000K CCT.3. CRI>80, High efficiencydriver with inbuild surge protection, over voltage protection, short circuit protection and operating at >0.9 PF. <5% THD 4. LED life of more then 35000 Hrs @ L70. 5. Suitable for Grid and POP mounting .Approved Make.:WIPRO/TISVA/HAVELLS/LIGHTING TECHNOLOGIES/PHILIPS\" |
| 257 | Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die castpowder coated and high U.V. & corrosion resistancewith diffuserwith company mark/name 160V to 270V, Power Factor more than 0.95, THD < 15%,CCT3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED LED driver efficiency > 85 %( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.). (A) Tube Light with integral driver. (iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet. cat-III |
| 258 | \"Supply Installation Testing Commisioning of Track LED luminaire with system power [(30W)± 5%] should be mounted in a 3 wire track sysytem, Available in Warm white [2700K] / ,CRI≥ 80, SDCM≤ 3, LEDs used have a life of 50000 burning hrs. & Lumen maintenance as per L70, The LuminaireSystem efficacy of >80LPW . Madeof PDC Aluminiumhousing for rapid thermal healing & Powder coated by Corrosion resistant Nano coating technology. The luminaire is fitted with precise beam reflector optics with beam angle of 24° or 40°. the fixture is capable of rotating through 360° and pivoting through 90°.High efficiency electronic driver with voltage range of 140-270V, Power factor > 0.95 and THD < 5%, Inbuilt surge protection of 4KV & additional SPD with 6KV protection. The luminaire & driver should be of same make. The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported .Selection of colour / colour temp. / throw of light will be decided by architect. Approved Make.:ERCO/LIGHTING TECHNOLOGIES/PHILIPS/FORMA LIGHTING\" |
| 259 | \"Supply Installation Testing Commisioning of Recess/Surface mounted/suspended 3 wire Track System . Should be available in Black/white body color it will be decided by architect.Should be using 3 wire system. Should be able to connect using interconnectors. The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . Approved Make.:ERCO/LIGHTING TECHNOLOGIES/PHILIPS/FORMA LIGHTING\" |
| 260 | RECESSED 60-75MM cutout 4FEET PROFILE LIGHT : SITC of DIMMABLE Indoor recess mounted 24W-26w 1200MM office lighting fixture with below features Fixture output efficacy 2400-2700Lumens. Extruded Aluminium alloy Housing and polycarbonate diffuser profile for continous decorative illumination Anodised aluminium end caps firmly fixed on the aluminium extrusion Silver anodised finish for elegant look . Efficacy of Fixture >=100 Lumens/Watt suitable for self adhesive LED Strips with driver for Installation/ PCB Mounted solution Available only in PCB option. Should be 4 feet length LED life of 50000 Hrs @ L70. IP20The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . Equalant in TISVA/WIPRO/HAVELLS/LIGHTING TECHNOLOGIES/PHILIPS\" |
| 261 | \"Supplying, Installation, testing & erectingof25-30w Indoordecorative Circular ring type Lighting, Dia=450 mm, W=46 mm, H=70 mm Suspended profile with below features System wattage-25-30w, Luminous Flux of luminaire to be more than 90 lumens per watt, 4000 K, CRI >80, 230V, Direct Emission, Profile in high quality powder coated, Halogen free internal wiring, should haver Prismitic Diffuser for Homogenous Light distribution. Protection Class I, IP 40, .Fixture should be available in 600mm dia.Body color shall be as per architects choice, manufacturer shall provide powder coated fine finish as per Architects selected RAL code. The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . (Approved Led source Nichia , Cree, Lumileds , Osram Only). Fixture/Fitting needs to be approved by the architect before installation Multiple Fixture BODY color options/RAL code option should be provided to architects team for selection.Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva \" |
| 262 | \"Supply Installation Testing Commisioning of Outdoor Architectural LED Flood light luminaire system power [(55W)± 5%] , Available in Cool / Neutral White color temperature (5700K / 4000K),CRI>70, SDCM<5 , LEDs used have a life of 50000 burning hrs. & Lumen maintenance as per L70, The LuminaireSystem efficacy of >150LPW. Madeof high grade ADC 12 PDC Aluminiumhousing for rapid thermal healing & Powder coated by Corrosion resistant Nano coating technology. L Injection moulded special PC lens optics ,ensuring low glare & best in class uniformity. Encapsulated IP 67 high efficiency electronic driver having Aluminium extrusion construction with rated voltage of 140-270V, power factor > 0.95, THD <10%, Inbuilt surge protection of 6 KV and upgraded with integrated IP67 protected SPD of 20KV/10KA surge protection with all necessary safety protection like mis-wiring, Over voltage, Short circuit, Reverse Polarity protection.IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab.Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & DriversApproved Make.:WIPRO/TISVA/HAVELLS/LIGHTING TECHNOLOGIES/PHILIPS\" |
| 263 | Supplying, Installation, testing & erectingof Waterproof surface mounted 6-9w spike light High Efficacy and low power consumption, protection to surge and transients of upto 4kv, Good quality of light with >70 CRI, high quality constant current driver with a very high input voltage range of 100-240V AC, Protector made offlat glass and metalised reflector for wider and symmetric light distribution. Luminous Flux of luminaire to be more than 90 lumens per wattMin IP 65Ingress Protection for Fixture and IP65 for Driver The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported) .Approved makes : Philips,Havells,Lighting technolgies, Wipro,Tisva |
| 264 | \"Supplying, Installation, testing & erectingof 500-600mm height Bollard Light with Following specifications .Housing made of pressure die cast aluminium alloy with powder coating Min IP I66 to ensure fixture is water and dust tight.. The product should be Manufactured in India (all the Components should be manufactured in India except the Led source which can be imported . (Approved Led source Nichia , Cree, Lumileds , Osram Only)Selection of colour / colour temp. / throw of light will be decided by architect. Multiple Fixture BODY color options/RAL code option should be provided to architects team for selection.Approved Make.:WIPRO/TISVA/HAVELLS/LIGHTING TECHNOLOGIES/PHILIPS\" |
| 265 | Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground/ road surface for enclosing cable (A)50 mm outer dia |
| 266 | Providing & laying approved makeDouble walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground/ road surface for enclosing cable (B)63 mm outer dia |
| 267 | FIRE EXTINGUISHER & SIGNAGES |
| 268 | Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc., ISI Marked portable fire extinguisher, 4.5 kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform to IS 2878 |
| 269 | Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc., ISI marked Fire Extinguisher, Dry Chemical powder type capacity 6 kgs conforming to IS : 2171 including first fill & wall suspension bracket. |
| 270 | Supplying, installation, testing & commissioning of Photo luminescent non toxic, non radioactive, maintenance free self glowing exit signs comprising zinc sulphide chargeable crystals which can glow in dark; printed on U-1000 photo luminiscent aluminium sheet 1.0 mm thick containing luminiscent 111 as base chemical cover with UV stabilized coating job complete with SS screws for wall mounting or to be hanged on rust proof chain for ceiling mounting complete in all respects, plate size 12\" X 18\" (general size, may increase or decrease depending on site requirements). Make : Pro-lite, Supreent Creation, Auto-Glow, Agni |
| 271 | ELV SYSTEM |
| 272 | SITC of4MP Fixed Lens Dome Type Camera,H.265 4MP IR Vandal Proof Dome N/W Camera, 2.8mm/3.6mm, 30M IR, Micro SD, DC12V/PoE, IP67/IK10, Basic IVA, 1 / 2.7\" CMOS, 2560 × 1440, 0.01 Lux, F1.2, AGC ON; Defog, True day/night, Digital WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Cyber Security, Basic intelligent video analytics, NDAA Compliance, UL, CE, FCC Certified |
| 273 | SITC of 64 Channel Network Video Recorder (NVR), Dual OS design, HDD Hot Swap with RAID support, N+1 hot spare configuration, Support 16CH@2MP, H.265/H.264 Video Compression, HDMI, VGA output, upto 8 SATA interface each with max 10 TB support and 1 eSATA, 16-ch synchronous playback at up to 1080p resolution, Gigabit Ethernet network interfaces, bandwidth 320 mbps, CE FCC, BIS, Operating Temp -10 deg to 50 deg C, USB and serial Interface, RAID supported |
| 274 | SITC of Conduit Box for CCTV |
| 275 | SITC of 24 x 10/100/1000BASE-T PoE ports 4 x Gigabit RJ45/SFP Combo ports Advanced L2 switching and security features L2+ Static Routing Optional “standard mode” or “surveillance mode” management user interface 193 W PoE budget |
| 276 | SITC of 6 TB Enterprise Harddisk |
| 277 | SITC of Next generation enterprise Wi-Fi 6 (802.11ax,802.11a,802.11b, 802.11g and 11n) access points, support 802.11ac standard with transmit power of 25dBm on both 2.4 GHz and 5 GHz, should support 20,40,80Mhz channelization, with 2 spatial stream SU/MU Mimo support on both radia bands,with 1GbE Port centrally managed and configured through controller. with minimum radio interferrance, Should support WPA-PSK, WPA-TKIP, WPA2 AES, WPA3-Personal, WPA3 enterprise, 802.11i, Dynamic PSK, OWE and WIPS/WIDS. The AP should support below advanced Wi-Fi features:· WMM, Power Save, Tx Beamforming, LDPC, STBC, 802.11r/k/v· Hotspot· Hotspot 2.0· Captive Portal· WISPr. The Access Point should implement below Wi-Fi alliance standards:Wi-Fi Enhanced Open™· Wi-Fi Agile Multiband™· Passpoint®· Vantage· WMM® . The Access Point should be Wi-Fi certified and WPC approved; ETA certificate to be enclosed. The AP should also certified for ITSAR or have a PRO TEM ITSAR certificate from NCCS. |
| 278 | FA System: Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with latest Ammendment with central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specification.(B) 2 Loop Panel |
| 279 | Supplying, installation, testing & commissioning of intelligentanalog addressablephotothermal detector having IS-11360-1985 or BS 5446 Part I-1977 & Part VII –1985 (VdS approved) or NFPA72 ( UL/ULC/FM approved) with Latest ammendment complete with mounting base complete as required. |
| 280 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cumfixedtempreature thermistor having IS-2175 - 1988 or BS-5445 ( EN 54) Part 5 –1977(VdS approved) orNFPA72 (UL/ULC/FM approved)complete with base as required. |
| 281 | Supplying, installation, testing & commissioning of Response Indicator. |
| 282 | Supplying,installation,testing&commissioningof addressable manual call point having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required. |
| 283 | SITC of Analogue addressable loop powered Base Sounder, variable sound output 50 ~ 98 dB(A) (±2 dB(A)) output at 1 metre, 51 user-selectable tones (all tones EN54-3 compatible), Auto shutdown feature preventsnoise-pollution, Approved by LPCB & VdS |
| 284 | Supply and Laying of 2 Core X 1.5 sqmm FRLS armoured copper Cable (Makefinolex /polycab / RR kabel /Avocab |
| 285 | Supply, Installation & Laying of 4K, HDMI Cable.Approved as per specification ofIT Department of RRU. |
| 286 | Supply, Installation & Laying of VGA Cable.Approved as per specification ofIT Department of RRU. |
| 287 | Providing & Erecting eight module pop up floor box/flushed with table surface Conform to IEC 60670-1, IEC 60670-23 & IEC 60884-1 with required items as demanded by engineer in charge with complete finishing .complete with 3 - 6A Socket Outlet with Switch, HDMI Port, VGA Port, Mic Input port, USB Port complete with required cover and accessories to complete the job. Kramer Make. |
| 288 | PA SYSTEM: Supplying and drawingof cable Fire Retardant PVC insulated copperconductorcableinthe existingsurface/recessed steelconduitoffollowingpairs,coresandsizeincluding connections and interconnections etc. as required.(B)Speaker cable Two pair, 2-core, 1.5 sqmm |
| 289 | Supply, installation, testing and commissioning of Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erectedwith necessary connection. As desired by Engineer In charge.Modem Jack for Computer & Telephone Open RJ-45 CAT III. |
| 290 | Supply Installation and Testing of Cat6 I/O for DATAand TELEPHONE- With BASE Plate |
| 291 | Supplying & erecting approved make LAN cable of following size in 25mm PVC Conduitpipe as per direction [D] CAT - 6e ( For LAN, Telephone & Camera). |
| 292 | SITC of CAT6 UTP 24AWG PATCH CORD:1M,Plug 30U\" Snag less [Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 293 | SITC of CAT6 UTP 24AWG PATCH CORD:2M,Plug 30U\" Snag less[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 294 | SITC of 24 x 10/100/1000BASE-T PoE ports 4 x 1/10/25 Gigabit SFP 28 SFP/SFP with VSS or VC clustering, Switching Bandwidth: The Switch should provide Switch Fabric Bandwidth Capacity of 248 Gbps or more and Packet Forwarding Capacity of 184 Mpps or more.Support 32K MAC addresses, Jumbo Frames, 4K Active VLans, Spanning Tree Protocols, Link Aggregation groups with 802.3ad Link aggregation control protocol, 802.1q tunneling with tagging, Private VLans, Layer 2 Switching Feature & Support 16K IPv4 and IPv6 layer 3 Routing features, with Traffic Management Feature, with SDN, Security & Monitoring Manageability, Switch shall ave 4MB Packet Buffer, 4GB Main Memory and 8GB Flash Memory with 370W POE Budget. |
| 295 | SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully LoadedApproved by Competent Authority i.e. not Below the rank of Executive Engineer ] |
| 296 | Providing & Erecting Netwrok rack with following capacity with Necessary cooling fan,Cable manager,6A PDU,equipment rack with necessary mounting accessories. (B) 6 U |
| 297 | (C) 12 U |
| 298 | (E) 22 U |
| 299 | Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erectedwith necessary connections as per site situation directed by Engineer In charge. (4) TV Co-axial Socket outlet |
| 300 | Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (e) RG-11 |
| 301 | Supplyingunder floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all accessoriesJointsas required and demanded by engineer-incharge andlaying/erectingas per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D x T) Cat-III : 100mm x 38mm x 1.6 mm with One Compartments |
| 302 | Supplyingunder floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water with all accessories,Junction Box,Jointsas required and demanded by engineer-incharge andlaying/erectingas per OEM guidelines and as per instruction of engineer incharge having following size of dimensions and No of compartments (W x D x T) Cat-III: 150mm x 150mm x 50 mmDeep |
| 303 | HVAC work |
| 304 | Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) |
| 305 | Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System. (E) 2 TR |
| 306 | (F) 2.4 TR |
| 307 | (H) 3.2 TR |
| 308 | Supply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (D) 1.65 TR |
| 309 | (E) 2 TR |
| 310 | Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments. (A) 2C X 1.5 Sq mm Shielded Armoured |
| 311 | (B) Central wired Remote Control System |
| 312 | (C) Cordless Remote Control |
| 313 | Installation, Testing , Comissioning of Refrigerent Seperation Tube. Refnet Joints |
| 314 | Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. (A) 50 mm dia. |
| 315 | (B) 40 mm dia. |
| 316 | (C.) 32mm dia. |
| 317 | (D) 25 mm dia. |
| 318 | (E) 19 mm dia. |
| 319 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint NOTE:- 1)The Copper Piping & Piping Circuit should be with Minimum Number of joints, which shall be attained by : (1) Using One End Expanded Tubes(2) Bending the tubes instead of using elbow joints wherever 90 degree bending is required. (3) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum.(4) The makes of tube fittings shall be same as that of tubes. (5) The thickness of fittings used shall be same as that of the pipe. 6). Size shall be as per Proposed HVAC Vendor to fullfill the requirement. |
| 320 | External Development (Paver block, Kerbing, stone sitting, otta etc.) |
| 321 | Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m : All kinds of soil |
| 322 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 323 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 324 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 325 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. ; 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 326 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 327 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling with all lead and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 328 | Supplying and stacking of good earth at site. work complete including royalty, all type of tools, tackles, scaffolding, safety measures, loading, unloading, transportation, all heights, all levels, all lead & all lift etc complete as per instruction of Architect/EIC. (earth measured in stacks will be reduced by 20% for payment). |
| 329 | Supplying and stacking at site dump manure from approved source, work complete including royalty, all type of tools, tackles, scaffolding, safety measures, loading, unloading, transportation, all heights, all levels, all lead & all lift etc complete as per instruction of Architect/EIC. (manure measured in stacks will be reduced by 8% for payment) : |
| 330 | Rough dressing the trenched ground including breaking clods. work complete including all type of tools, tackles, scaffolding, safety measures, loading, unloading, transportation, all heights, all levels, all lead & all lift etc complete as per instruction of Architect/EIC. |
| 331 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation |
| 332 | Fine dressing of the ground. |
| 333 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 334 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge |
| 335 | Grassing with selection No. 1 truf grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed. With grass Turf |
| 336 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 337 | Providing and Displaying Travelers palm well developed with fresh & healthy leaves foliage 210 to 240 cm ht specimen in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 338 | Providing and displaying of Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 339 | Providing and displaying of Croton Baby Golden (three in one)/ Lemon croton, having ht. 30cm, multi branches, well developed with fresh and healthy foliage in 25 cm size of Earthen pot/Plastic pot. as per direction of the officer-in-charge |
| 340 | Providing and stacking of Nerium oleander (kaner)/ Nerium Draf of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm as per direction of the officer-in-charge. |
| 341 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 342 | Providing and displaying of Dracaena Kedarnath, Dracaena mahatma, Dresina Red etc. having ht. 30 cm & above, well developed with good colorful foliage in 20 cm size of Earthen pot/ Plastic pot. & as per direction of the officer-in-charge. |
| 343 | Providing and displaying of Schefflera high colour (three in one), having ht. 25 cm to 30 cm, well developed with fresh and healthy foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 344 | Providing and displaying of Schefflera Varieged, mounted on moss stick 90 cm ht., 3 to 4 s placed in each pot at equal distance, well developed with full of fresh & healthy bright leaves from bottom to top in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 345 | Providing and displaying of Phoenix palm having ht. 75 cm to 90 cm with 10 to 15 or more leaves, well developed, fresh and healthy in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. |
| 346 | Providing and Displaying Champions palm/ Mascarena palm well developed with fresh & healthy foliage leaves 150 to 180 cm ht in 35 cm Cement Pot as per direction of the officer-in-charge. |
| 347 | Providing and Stacking of Pandanus plant of height 90 -105 cm. multibranches, well developed in poly bags of size 25 cm as per direction of the officer-in-charge. |
| 348 | Providing and Stacking of Tarpeta plant of height 90 -105 cm. multibranches, well developed in poly bags of size 25 cm as per direction of the officer-in-charge. |
| 349 | Providing and Stacking of Green Erenthmum plant of height 90 -105 cm. multibranches, well developed in poly bags of size 25 cm as per direction of the officer-in-charge. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail