Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-10-2025 | Corrigendum10 | Date | 29-12-2025 |
| 2 | 03-09-2025 | Corr9 | Date | 27-10-2025 |
| 3 | 22-07-2025 | Corr8 | Date | 08-09-2025 |
| 4 | 07-07-2025 | Corrigendum 7 | Other | 28-07-2025 |
| 5 | 07-07-2025 | Reply of Pre Bid Queries | Other | 28-07-2025 |
| 6 | 11-06-2025 | Corrigendum6 | Date | 28-07-2025 |
| 7 | 11-06-2025 | Corrigendum5 | Other | 28-07-2025 |
| Sl. No. | Item Description |
| 1 | Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 2 | 200 mm dia |
| 3 | 250mm dia |
| 4 | 300 mm dia |
| 5 | 350 mm dia |
| 6 | 400 mm dia. |
| 7 | 450 mm dia |
| 8 | 500 mm dia |
| 9 | 600 mm dia |
| 10 | 800 mm dia |
| 11 | 900 mm dia. |
| 12 | Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating).Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 13 | OD 813 mm dia and thickness 7.1 mm |
| 14 | OD 914 mm dia and thickness 8.0 mm |
| 15 | OD 1067 mm dia and thickness 8.8 mm |
| 16 | OD 1118 mm dia and thickness 8.8 mm |
| 17 | OD 1422 mm dia and thickness 10.5 mm |
| 18 | OD 1422 mm dia and thickness 12.5 mm |
| 19 | Outer dia of pipe 1626 mm and 14.2 thickness |
| 20 | OD 1727 mm dia and thickness 12.5 mm |
| 21 | OD 1727 mm dia and thickness 14.2 mm |
| 22 | OD 1727 mm dia and thickness 17.5 mm |
| 23 | OD 1829 mm dia and thickness 10.9 mm |
| 24 | OD 1829 mm dia and thickness 12.5 mm |
| 25 | OD 1829 mm dia and thickness 14.2 mm |
| 26 | OD 2032 mm dia and thickness 16 mm |
| 27 | 1524 mm dia/14.2 mm th |
| 28 | OD 219.1 mm dia and Thickness 4.5 mm |
| 29 | OD 273 mm dia and thickness 5.0 mm |
| 30 | OD 323.9 mm dia and thickness 5.6 mm |
| 31 | OD 457 mm dia and thickness 6.3 mm |
| 32 | OD 610 mm dia and thickness 8.8 mm |
| 33 | OD 711 mm dia and thickness 8 mm |
| 34 | OD 1016 mm dia and thickness 8.8 mm |
| 35 | OD 1219 mm dia and thickness 10 mm |
| 36 | Providing and applying Spray applied, 100% Solids (Solvent free) Two Component PU ( Polyurethane) coating as per AWWA C222 Standard on external surface of M.S. Pipe including preparation of pipe outer surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2 including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Minimum dry film thickness of coating shall be 1000 micron |
| 37 | Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Liquid Epoxy shall be NSF/WARS approved for drinking water and minimum thickness of lining shall be 406 microns. |
| 38 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil |
| 39 | In All Typeof Soil |
| 40 | Add extra for trenches for every additional lift over item no 4.1 |
| 41 | Above 1.5 mtr and up to 3.0 mtr. |
| 42 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each depositedlayer by ramming, watering etc.and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required |
| 43 | Ordinary rock |
| 44 | Hard rock (Blasting prohibitated) |
| 45 | Add extra for trenches for every additional lift over item no 4.1 |
| 46 | Above 1.5 mtr and up to 3.0 mtr. |
| 47 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. |
| 48 | Providingandlayinginpositionspecified grade of reinforced cement concrete includingcuringcompactionfinishingwith rendering in cement sand mortar 1:3 (1- Cement:3-coarsesand)and making good the jointsexcludingthecostofcentering, shuttering and reinforcement.All work up to plinth level : |
| 49 | 1:2:4(1-Cement:2-coarsesand:4-graded stone aggregate 20 mm nominal size). ( Encashing of Pipe in River/ thrust block)) |
| 50 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix( Encashing of Pipe in River/ thrust block)) |
| 51 | Providingandfabricatingreinforcementfor R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. |
| 52 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level. |
| 53 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proofKinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammended up to date) Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will have a screen to prevent Tamper of float,with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amendedupto date) PN 1.6 ratings Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 54 | Class PN 1.6 |
| 55 | 50 mm dia |
| 56 | 80 mm dia |
| 57 | 150 mm dia |
| 58 | 200 mm dia |
| 59 | Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge. |
| 60 | Air valve pillarfor airvalves size of 80mmdia |
| 61 | Air valve pillarfor airvalves size of 150mmdia |
| 62 | Air valve pillarfor airvalves size of 200mmdia |
| 63 | Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 64 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 |
| 65 | 100 mm dia |
| 66 | 150 mm dia |
| 67 | 200 mm dia |
| 68 | 250 mm dia |
| 69 | 300 mm dia |
| 70 | 500 mm dia |
| 71 | 600 mm dia. |
| 72 | 700 mm dia. With Gear |
| 73 | 800 mm dia. With Gear |
| 74 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in- charge.\"Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 75 | Class PN 1.6, Manually Operated with Gear |
| 76 | 350 mm dia |
| 77 | 600 mm dia |
| 78 | 800 mm dia. |
| 79 | 900 mm dia. |
| 80 | 1000 mm dia. |
| 81 | 1100 mm dia. |
| 82 | 1400mm dia. |
| 83 | 1600 mm dia |
| 84 | 1800 mm dia |
| 85 | 2000 mm dia |
| 86 | 1300 mm dia. |
| 87 | 1500 mm dia. |
| 88 | 1600 mm dia |
| 89 | 500 mm dia |
| 90 | 600 mm dia |
| 91 | Providing, lowering,aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioningand as per technical specifications and direction of Engineer In-Charge. Class PN 1.0 |
| 92 | 100 mm dia. |
| 93 | 150 mm dia. |
| 94 | 200 mm dia. |
| 95 | 250 mm dia. |
| 96 | 300 mm dia. |
| 97 | 350 mm dia. |
| 98 | 400 mm dia. |
| 99 | 500 mm dia. |
| 100 | 600 mm dia. |
| 101 | Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specificationscompleteofthefollowing sizes including all jointing material, cost of alllabour,testingand commissioning Technical Specifications and as per direction of Engineer. |
| 102 | 700 mm dia. |
| 103 | 800 mm dia. |
| 104 | 900 mm dia. |
| 105 | 1000 mm dia. |
| 106 | 1100 mm dia. |
| 107 | 1400mm dia. |
| 108 | 1600mm dia. |
| 109 | 1800mm dia. |
| 110 | 2000mm dia. |
| 111 | 1300 mm dia. |
| 112 | 1500 mm dia. |
| 113 | 1700 mm dia. |
| 114 | 1400 mm dia. |
| 115 | 1600 mm dia. |
| 116 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. |
| 117 | Class PN 1.0 |
| 118 | 200 mm |
| 119 | Construction of RCC Air valve chamber fordifferent typeof valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concreteworkcompleteinallrespectasper specificationsand standard drawings and as directed by Engineer-in-Charge. |
| 120 | For Class-AA loading |
| 121 | Air valve chamber of size1.05m x1.4m x2.42m for air valve size of 150mm |
| 122 | Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concreteworkcompleteinallrespectasper specificationsand standard drawings and as directed by Engineer-in-Charge. |
| 123 | For Class-AA loading |
| 124 | Sluice valve chamber of size 1.13 m x0.85 m x1.325 m- for pipe size-upto 100 mm |
| 125 | Sluice valve chamber of size 1.17m x 0.95m x1.47m for pipe size-from 125-to-150mm |
| 126 | Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm |
| 127 | Sluice valve chamber of size 1.39m x1.43m x2.245m for pipe size-from 350-to-450mm |
| 128 | Sluice valve chamber of size 1.61m x1.75m x2.85m for pipe size-from 500-to-700mm |
| 129 | For in-campus Valve Chambers |
| 130 | Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm |
| 131 | Sluice valve chamber of size1.26m x1.185m x1.82m for pipe size-from 200-to-300mm |
| 132 | Sluice valve chamber of size1.61m x1.75m x2.72m for pipe size-from 500-to-700mm |
| 133 | Valve Chamber size2.50X2.10 X2.10Valve size 800 mm to 900 mm |
| 134 | Valve Chamber size2.80X2.50X2.50 Valve size 1000 mm to 1200 mm |
| 135 | Valve Chamber size3.00X2.50 X2.80Valve size 1300 mm to 1500 mm |
| 136 | Valve Chamber size3.00X2.75X3.10 Valve size 1600 mm to 1800 mm |
| 137 | Valve Chamber size3.00X3.00X 3.30 Valve size 1900 mm to 2000 mm |
| 138 | Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, BearingBush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2.Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 139 | Plunger Type Flow Control Valve |
| 140 | 200mm dia |
| 141 | 250mm dia |
| 142 | 300mm dia |
| 143 | 350mm dia |
| 144 | 400mm dia |
| 145 | 600mm dia |
| 146 | 800mm dia |
| 147 | Supply and Pushing of MS casing pipe of specified thickness by trenchless method adopting micro-tunnelling or any suitable mechanical technology or technology approved by Railway below ground at all depth under running traffic condition as per railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipment’s for completion of works, mobilizing ofmachineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (upto 3 metre depth) with proper protection at three sites with shoring sheets and ISMB\"s. Providing MS cutting edges for front shield and Constructing thrust bed at designated level. Necessary de-watering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Railway Authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per requirement and as per approved by railway authorities, specification and the direction of the Engineer. (Protective coating/ lining if done that will be paid extra) Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable. |
| 148 | In all type of soils |
| 149 | 600 mm dia 12 mm thick casing pipe |
| 150 | 1000 mm dia 14 mm thick casing pipe |
| 151 | 1400 mm dia 20mm thick casing pipe |
| 152 | 1600 mm dia 22 mm thick casing pipe |
| 153 | 1800 mm dia 22 mm thick casing pipe |
| 154 | 2000 mm dia 22 mm thick casing pipe |
| 155 | In Rock |
| 156 | 600 mm dia 12 mm thick casing pipe |
| 157 | 1000 mm dia 14 mm thick casing pipe |
| 158 | 1400 mm dia 20mm thick casing pipe |
| 159 | 1600 mm dia 22 mm thick casing pipe |
| 160 | 1800 mm dia 22 mm thick casing pipe |
| 161 | 2000 mm dia 22 mm thick casing pipe |
| 162 | Providing, laying and jointing RCC NP4 jacking pipe (with steel pushing collar) with suitable leak proof joints (with using `12mm MDF sheets etc.) with compliance for maintaining slope as per design by trenchless method adopting Micro tunnelling method or any suitable mechanical technology below ground at all depth under running traffic condition including carrying out survey work at the job site for determining underground cable trenches like telephone, power cable, water & sanitary lines and resistivity tests for finding the soil strata using necessary equipment’s for completion of work, mobilizing of machineries and specialized crew at the job site, etc. complete in all respects, including excavation of drive pit and exit pit (upto 3 metre depth) with proper protection at the three sides, providing and casting of MS cutting edges for front shield and constructing thrust bed at designed level as directed by the Engineer, necessary de-watering and providing concrete foundations at the base of the Drive pit, crane for handling of pipes, and any other machinery, tool & tackles required, construction of temporary works as per requirement complete in all respect (all depths) with all lead and lifts, as per specification and the direction of the Engineer. Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable. |
| 163 | 500 mm dia RCC pipe |
| 164 | Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. |
| 165 | Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. |
| 166 | Bituminous courses |
| 167 | Granular courses |
| 168 | Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. |
| 169 | Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. |
| 170 | M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 171 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 172 | Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including gettingout the excavated soil anddisposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available : |
| 173 | Ordinary rock |
| 174 | Hard rock(blasting prohibited) useful material 30% |
| 175 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 176 | M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 177 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. Providing M-25 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix |
| 178 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.Providing M-25 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix |
| 179 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : |
| 180 | Columns, pillars, posts and struts etc. |
| 181 | Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. |
| 182 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. |
| 183 | Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 184 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 185 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : |
| 186 | Two or more coats on new work |
| 187 | GSB Providing, laying, spreading and compacting of granular sub-base by providing close graded material (Table 400-1), spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion. |
| 188 | For Grading II Material |
| 189 | WBM Grading 1 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; handpacking, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up the interstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete. |
| 190 | Crusher broken - Grade-III (53-22.4mm) |
| 191 | Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. |
| 192 | Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as per Table 500-23, premixed with bituminous binder @ 14.60 kg/ 10sqm (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required), including loading of material with F.E. loader, hot mixing of stone aggregate and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting smooth wheeled roller 8-10 tonne capacity and finishing to required level to achieve the desired density as per clause 511 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding cost of tack coat/ seal coat. |
| 193 | With Bitumen VG-grade 30 |
| 194 | Carriage of Materials by mechanical transport including loading,unloading and stacking :: |
| 195 | Building Rubbish Stone metal (Grit and ballast etc.) up to 1 KM |
| 196 | Surg Protuction |
| 197 | Provision for surg protuction as per detail estimate |
| 198 | Provision for Cathodic protuction as per detail estimate |
| 199 | Construction of RCC (Flat slab type) Rectangular partially underground Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase in side and out side. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. |
| 200 | d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab.j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m)Construction of inlet chamber, and valve chambers n) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. |
| 201 | 22500Kl(Kishangarh bas) |
| 202 | 37000 KL ( Kot) |
| 203 | 39000 KL ( Jugawar) |
| 204 | Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
| 205 | 200 mm |
| 206 | 350 mm |
| 207 | Providing, lowering, laying, aligning, fixing in positionand jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet andjointingasperIS:9523-2000 or as amended up to date,suchastees,bends, tapers,caps etc. within trenchesin DI pipe line completeincluding all material,labour, taxes, testingand commissioningalong with pipe line as per technical specifications anddirection of Engineer-in-charge (excluding earth work). |
| 208 | All End Flanged |
| 209 | Up to 300 mm Diameter |
| 210 | Above 300mm and up to 600 mm diameter |
| 211 | Above 600 mm diameter |
| 212 | Up to 300 mm Diameter |
| 213 | Above 300mm and up to 600 mm diameter |
| 214 | Above 600 mm diameter |
| 215 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. |
| 216 | MS pipespecialsup to600mmdia (withminimum5mmthickness sheet) |
| 217 | MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet) |
| 218 | SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. |
| 219 | EFM 200 mm |
| 220 | EFM 400 mm |
| 221 | Providing, Installation, Testing and Commissioning of Ultrasonic Flow Meter Insertion Type: Principle: Time of Flight / Type: Insertion / Protection : IP68 / Power Supply: 230 V AC / Output : 4-20 mA with HART / Accuracy: 2 - 3% |
| 222 | 1000 -4000 mm |
| 223 | Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoorand outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm. Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx. |
| 224 | Type VII ( 692.72 Sqm) |
| 225 | Construction of Pump house of RCC framed structure Pump and panel room structure over RCC sump for Instalation of VT pumps as perGA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoorand outdoor lighting and fans, rain water drainage, sanitary, plumbing, / EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm.( Sump Size 35X6.0 Mtr and depth 6.0 Mtr. including Loading / unloading/Maintanace Bay 10X 3 Mtr, scada / office room 10 X4.0 mtr, Electrical panel platformsize 35 X 4.0 Mtr. |
| 226 | As per Detail Estimatebased on BSR PWD 2022 |
| 227 | Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done. |
| 228 | PH Kishangarh Bas IPS+CPS |
| 229 | PH Jugrawar IPS+CPS |
| 230 | IPS Kot (Balancing Reservoir) |
| 231 | Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints. |
| 232 | Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed:All kinds of soil |
| 233 | Horticulture Work |
| 234 | Supply of dry manure including loading unloading,transportation & stacking at site |
| 235 | Farm yard manure(organic) |
| 236 | Goat dungmanure. |
| 237 | Vermi compost |
| 238 | Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. Good soil of Earth. |
| 239 | Supply of different varities of tree/shrubs/climbers according to height and age of the plant at side including loading/unloading & transportation etc.complete |
| 240 | Different flowering plants 900mm to1500mm |
| 241 | Different varieties of shrubs 600mm to 900 mm |
| 242 | Different varieties of climbers 900mm to 1500 mm |
| 243 | Spreading of manure , good earth in required thickness (cost of manure and good earth to be separately ) |
| 244 | Uprooting weeds from the lawn plots and trenched area after 10 to 15 days of its flooding with including disposal of uprooted vegetation |
| 245 | Laying of lawns including ploughing leveling breaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost |
| 246 | in rows 7.5 cm apart in either direction |
| 247 | Supply & Planting of shady plants ( Neem. Peepal, Goolar, Jamun, Imli or other specified) along road side including the following activities:-(i) Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. (ii) Supply of plant at site of two years of age & height more than 1.50 Mtr. (iii) Supply of dry manure(Farm yard manure organic) (iv) Supply of Insecticides. (v) Digging of pits size 60x60x60 cms. Including removal of stones. Manuring application of insecticides & watering at least 1.5 Liter per plant after planting (vi) Half brick Circular tree guard in second class bricks, internal dia 1.25 meter and height 1.20 meter above ground and 0.20 meter above ground and 0.20 meterr below ground. Bottom two courses laid dry and top three couses in cement mortar 1:6( 1 Cement : 6 Sand) and the intermediate courseses being in dry honey comb masonry. As per design complete.(vii) Watering to plants (viii) Maintance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc & application of insecticiedes etc. & security. If the plant die during maintence contractor has to rplace same heingh plant at his own cost. |
| 248 | Provision for Construction of Half Set Chokidar Hut |
| 249 | Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. (For watering in plants and lowns) |
| 250 | HDPE PE-100PN-6 |
| 251 | 75 mm dia |
| 252 | P & F G.I. Pipeswith G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :-( External Work ) Medium Duty Pipes |
| 253 | 25 mm dia nominal bore Class-B |
| 254 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : |
| 255 | Gun-metal 25mm nominal bore. |
| 256 | Gun-metal 50 mm nominal bore. |
| 257 | Making connection of G.I. distribution branch with G.I. main including all fitting. |
| 258 | Upto 25mm dia |
| 259 | Surface Drainage Work |
| 260 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. |
| 261 | PCC work - M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). |
| 262 | M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 40mm nominal size). |
| 263 | Brick work with F.P.S. bricks of class designation 75 infoundation and plinth in:1:6 C. Mortar |
| 264 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20 mm th |
| 265 | Providing and fixing of reinforced Ferro-Cement drain covers designed for \"A\" class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc |
| 266 | Standard Size 600x800mm (75mm thick) for span 300 to 450mm |
| 267 | Construction of RCC platform for transfarmer near Pump house as per detail specification and GAD, Size 3.00 mtr. X 3.00 mtr. outer 1) Earth work 0.60 width and 0.60 mtr. Deep for 4 nos wall, 2) PCC inM-10 with 20 mm stone aggrigate, 3) Raft for wall- 0.45 mtr. width - 0.15 mtr. thick. 4) 0.15 Mtr. thick RCC wallupto 1.00 mtr. above from GL. 5) earth filling with compaction in side. 6) 0.15 mtr. thick PCCM-10 under floor and7) 0.15 mtr. thick RCC M-20 flooring complet as per direction of EIC. |
| 268 | Supply, Testing & Commissioning of Vertical Turbine pump motor set of specified duty parameters & guaranteed efficiency of following MOC with specified capacity horizontal foot mounted TEFC squirrel cage induction motor, working on three phase AC supply with 50 Hz ± 3%, 3.3 KV ± 10%, rated speed 1000 RPM along with column and bowl assembly, discharge head, base channel/RSJ etc. complete as per relevant IS. M.O.C.: Impeller & Sealing Rings:CF8M, Bowl & Suction Bell: CI FG 260 IS: 210 with 2% Ni , Shaft with coupling: SS 410, Column Pipe: M.S. ERW, Mechanical Seal (above 30 kW), Base Plate: MS, Line Bearing: Thordon type, Suction Strainer: S.S. |
| 269 | from WTP to Kot 900 KW - 3.3 KV/TEFC, Discharge -619 LPS, Head- 116Mtr. Column-7 Mtr |
| 270 | Supply, Testing & Commissioning of Horizontal Split casing centrifugal pump motor set of specified duty parameters & guaranteed efficiency of following MOC with specified capacity, horizontal foot mounted TEFC squirrel cage induction motor, working on three phase AC supply with 50 Hz ± 3%, 3.3 K V ± 10%, rated speed 1450 RPM along with fabricated MS base frame, coupling, coupling guard, foundation bolts etc. as per relevant IS. M.O.C.: Impeller & Wearing Rings: CF8M, Casing: Cast Steel WCB , Shaft: SS 410, Shaft Sleeve: SS 410, Mechanical Seal (above 30 kW), Base Frame: MS. |
| 271 | 275 KW Discharge 357 LPS , head 45 mtr.(IPS Kishangarh Bas to Bhiwadi Line) |
| 272 | 850 KW Discharge 619 LPS , head 93 mtr.(IPS Kotra to Jugarwad Line) |
| 273 | 850 KW Discharge 407 LPS , head 142 mtr.(IPS Jugarwad to Kishangarhbas) |
| 274 | Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal Nut- Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. |
| 275 | Class PN 1.6 |
| 276 | 500 mm dia |
| 277 | 600 mm dia |
| 278 | Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge. |
| 279 | 500 mm dia. |
| 280 | 600 mm dia. |
| 281 | 700 mm dia. |
| 282 | 800 mm dia. |
| 283 | Electromagnetic Flow Meter : Liner: Polyurethane or Hard Rubber /Electrode MOC: SS316L or CS /Housing : Die Cast Aluminium orCS / Power Supply: 90-230 V AC / Output: 4-20mA with HART /Sensor Cable : 10 mt / Flow Tube or Sensor housing protectionIP68 / Process Flange : SS316 / Display : 3 1/2 LCD Display /Cable Connection : 1/2\"NPT /Accuracy : 0.5% |
| 284 | 900 mm dia. |
| 285 | Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum |
| 286 | Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. |
| 287 | 2.2 KW (3.0 HP) |
| 288 | Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. |
| 289 | 50 mm |
| 290 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase upto 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply. |
| 291 | Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. |
| 292 | 3 core 4.0 Sq.mm |
| 293 | Supply, receving, storing,inspection, handling , assembilng ,installing in correct alligned position, effecting proper connections,testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer(+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 450/400 C first fill oil, having permissible totak less values not exceeding 7.5% of the maximum total loss values for 11KVasperenergyefficiencylevel-2atbasicInsulationlevel conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014. |
| 294 | 1000 KVA |
| 295 | 315 KVA |
| 296 | 10000 KVA (33KV / 3.3 KV) AS PER IS 2026 |
| 297 | 8000 KVA (33KV / 3.3 KV) AS PER IS 2026 |
| 298 | 1600KVA (33KV / 3.3 KV) AS PER IS 2026 |
| 299 | O.L.T.C. With R.T.C.C. & AVR (FOR 33KV TRANSFORMERS) |
| 300 | Supply,Installation,testingandcommissioningof33KVDouble PolestructurewithAirBreakSwitchhavingfollowing specifications.a) DP : Double Pole structure made of two nos. 11 m long PCC poles (400Kg) & 7 nos. MS Channel size 100x50x6mm complete with earthing of the structure as perREC standardsin all respect with nuts, springs washers, clamps as required.b) GO: Off load type gang operated three pole Horizontal type switch suitable for 33KV, 800A, 3phase central post rotating double break isolator completewithMSHardware,coppermoving&fixedcontacts, assembly of 9 Nos. Post Insulators, GI pipe of suitable length for operation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.e)LA:3piecenonlinearresistortypelightening arrestorofapprovedmakesuitablefor3wire,33KVohlinewith rated voltage 30KV rms & nominal discharge current rating of 10 KA & complete with galvanized clamping arrangement, GI bolts, nuts, washers etc. as required.e)Jumpers:3 Nos. ACSR Dog Conductor mountedonpintypeinsulatorsasrequired.TheGOshallbe operated by hand operated liver properly earthed with provision for locking mounted at 3’. Complete as per technical specifications and /or as directed by engineer. |
| 301 | Supply, Installation, Testing and Commissiong of indoor type floor mountedmetalclad,33KVIncomerVCBpanelupto630A equipped with following switchgears and accessoriesdesigned & tested as per latest standard i.e. IEC 62271-200, suitable for STC 31.5KA/3andIACA-FLRfor31.5kA/1sec.MakeofHTPanel, Vaccum Interrupter and VCB should be of same make. |
| 302 | 33 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 36 KV on incomer, Ammeter,analogtype,selectorswitchesforammeters, MicroprocessorbasednumericalrelaywithO/L,E/FandS/C protection, Set of dual core dual ratio 3CTs of suitable ration with sec 1 of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter. |
| 303 | Supply, Installation, Testing and Commissiong of indoor type floor mountedmetalclad,33KVBusCouplerVCBpanelupto630A equipped with following switchgears and accessories. STC 31.5KA/3 and Internal Arc test A-FLR for full short circuit current for 1 sec. duration. Make of HT Panel,Vaccum Intrrupter and VCB should be of same Make. Bus Coupler 1 No 630 Amp. VCB |
| 304 | Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 33 KV Incomer cum outgoing VCB panel up to 630Aequippedwithfollowingswitchgearsandaccessoriesdesigned&testedasperlateststandardi.e.IEC62271-200, suitable for STC 31.5KA/3 and IAC A-FLR for 31.5kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make. |
| 305 | 33 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 36 KV , Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core dual ratio 3CTs of suitable ration with sec 1 of 15 VA burden and accuracyClass–0.5formeteringandclass5P10forprotection, Multifunction Meter |
| 306 | SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries,FCBC(Floatcumboostcharger)suitablefor415V+/-10%,50Hz,1-ǿ / 3 -ǿ Input & 24/ 48 /110 V DC Output Natural Cooled,freestandinginSheetSteelenclosure,SCRcontrolled, regulation+/-1%,Efficiency>75%onFLAC/DCInstruments, SelectorSwitch,BuiltinDCDistributionBoard(6NoMCB), indication , control as required. All as per pre approved by Engineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR . |
| 307 | Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 33 K.V.(E) confirming IS :7098 P - 2withH4-GradeelectrolyticaluminiumconductorconfirmingtoIS:8130 class-2ofpurity>99.6%,InsulationScreening:Extruded SemiconductingCompoundfollowedbyhelicallywrappedCopper Tape,round/flatstriparmouringofcables,Inner/outersheath PVCtypeST-2confirmingtoIS:5831inexistingRCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have it\"s own in houseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 308 | 3 core 240.0 Sq.mm |
| 309 | Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kitsuitable for11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test reportshouldbeasperIS13573:2011whichcoveredallsequence fortable2forterminationkitandtable3forstreightthroughjoint inclusive thermal & dynamic short circuittest, humiditytest, soil fog test.CrosslinkingshallbedoneoutsidefactorywithE-beam/ peroxidetechnology.ExtrusionprocessshallbeinhouseOEM withinsamevicinity.includingtestingetc.asrequiredoffollowing sizes. All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR . |
| 310 | 3 core 240/300/400 Sq.mm |
| 311 | 3 core 240/300/400 Sq.mm |
| 312 | 3 core 240/300 Sq.mm |
| 313 | 4 core 240/300 Sq.mm |
| 314 | PlateEarthlingasperIS:3043withcopperEarthplateofsize 600mmx600mmx3.0mmbyembodying3to4mtr.Belowthe ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C.finishedchambercoveredwithhingedtypewithlocking arrangementC.I.Cover,C.IFrameofsize300mmx300mm completewithalternatelayersofsaltandcoke/charcoal,testingof earth resistance as required. |
| 315 | Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia.‘B’classG.I.Pipeincludingallaccessorieslikenut,bolts, reducer,nipple,wiremeshedfunnel,andC.C.finishedchamber coveredwithhingedtypewithlockingarrangementC.I.Cover,C.I. Frame of size 300mm x 300 mm and embodying the pipe complete withalternatelayerssaltandcoke/charcoal,testingofearth resistance as required. |
| 316 | S & Laying following size ‘B’ Class G.I.Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required. |
| 317 | 50 mm dia. |
| 318 | Supply&Layingfollowingsizeearthstripinhorizontalorvertical runinsurfacebymeansofEarthstripDMCInsulatorincluding riveting/soldering/welding,Jointingshallbedonebyoverlapping andwith2setofBrass(forCustrip)/GI(forGIStrip)nutbolt& springwasherspacedat50cmmakingconnectionetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 319 | 50mm x 6mm copper strip |
| 320 | 25mm x 6mm G.I. ( Hot Dipped) Strip |
| 321 | 32mm x6mm G.I. ( Hot Dipped) Strip |
| 322 | 50mm x 6mm G.I. ( Hot Dipped) Strip |
| 323 | Supply,Fabricating&installingfollowingsizesofperforatedHot dippedGalvanizedironcabletray(Galvanizedthicknessnotless then 50 microns) with perforation not more then 17.5% in convenient sectionincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended fromtheceilingwithGIsuspendersincludingGIbolts&nuts, fastners,supportsetc.asrequired.Allasperpreapprovedby Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 324 | 100mm x 50mm x 1.6mm |
| 325 | 150mm x 50mm x 1.6mm |
| 326 | 300mm x 50mm x 1.6mm |
| 327 | SupplyinganddrawingPVCinsulated&sheathedsolid/stranded copperconductormulticorecontrolcableISImarked(IS:1554)of 1.1kVgradeofapprovedmakeasperchapterE11,inexisting surfaceorrecessedconduit/casingcappingincludingmaking connections etc. as required. |
| 328 | 4 core, 1.5 sq. mm. armoured |
| 329 | 8 core, 1.5 sq. mm. armoured |
| 330 | 8 core, 2.5 sq. mm. armoured |
| 331 | 19 core, 2.5 sq. mm. armoured |
| 332 | Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - Iof1.1KVwithH4-Gradeelectrolyticaluminiumconductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC /Hume/Stoneware/PVCpipe/openduct/cabletrench/Cable tray(withcabletie)includingtestingetc.asrequiredoffollowing size.OEMmusthaveit\"sowninhouseNABLaccrediated LaboratoryfortestingprocedureasperIS:10810.Foradditional technicalparametersofproduct/workreferAnnexure\"A\"attached with this BSR |
| 333 | 400 SQMM,3.5 CORE |
| 334 | 300 SQMM,3.5 CORE |
| 335 | 120 SQMM, 3 CORE |
| 336 | 35 SQMM, 3 CORE |
| 337 | 16 SQMM, 3 CORE |
| 338 | 4.0 SQMM, 3 CORE |
| 339 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/freestandingfloormounteddustandverminproof compartmentalisedcubicalpanelasspecificationsandOther parameters requiredas per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:-(a)ThicknessofCRCAsheetshallbe2.0mm,cablealley compartmentshavingconcealedhingedtypedoorswithkeytype lock with / withoutdetachable extension type structure. Removable 3mm.thicksheetsteelglandplateswithappropriatesizeof knockouts for cables shall be provided(b)completepanelshallundergoaprocessofdegreasing,Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panelhavingPEfoam/Neoprenerubbergasketofnotlessthan 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) nterconnectionbetweenbusbarandswitchgears/cableshall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried outwith1.5Sq.mm,Earthwirewith2.5Sq.mmandCTwith2.5 sq.mmflexiblecopperwireonly.Alljoints/interconnectionsof copper bus bar shall be dully tinned . Clearance between main bus barandrisers/metalpartsshallbeatleast10mmadditionalto widthofbusbarBusbarisinsulatedbyHeatShrinkablesleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (CostofBusbar/FlexiblewireforInterconnectionbetweenMain connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)FloormountedpanelshallbemountedonBaseframeofISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute)shallbemeasuredbetweenphases,betweenphaseand neutralandbetweenphaseandearth.bothbeforeandafterhigh voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to befabricatedonlyfromCPRIapprovedfabricatoronly(CPRITest certificates to be submitted)All as per preapproved byEngineerin-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .busbar and Switchgearis to be Paid Extra ) (d)WiringbetweencomponentswithinswitchgearandIncoming/ outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted.Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads,studswithtwonutsandidentificationstripsandshallhave adequate continuous current rating. For tap-offs, adjacent terminals withshortingstripsshallbeused.10%Spareterminalblocksshall be provided. Wire identification on marking strip shall correspond to thedesignationofthewiringdiagrams.Allwireterminalsonthe equipmentshallalsobemarkedwithdesignationcorrespondingto those of the wiring diagram. (e)Allwiringshallbeenclosedinplasticchannelsandneatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee |
| 340 | SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/ Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwithstandardshortcircuitwithstandcapacity,hightensilenuts and bolts spring washers in existing panel including bending , cutting inrequiredshapeandsizeandcolourcodingwithheatshrinkable PVCsleeves.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 341 | Electrolytic grade Aluminium bus bar 6010 grade |
| 342 | Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/Frequencymeter/KWHmeter/MultiFunctionMeter/ Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96mmincludingmakingconnectionbyPVCinsulatedcopper conductorwithPVCsleeves/channeletc.asrequired.Allasper preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR . |
| 343 | Three phase with universal Auxiliary supply + AMP + HZ + PF + KW +KVA+KVAR+KVARH+KWH+DUALENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 |
| 344 | ThreephaseAMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS |
| 345 | Providing&FixingofBISapprovedCurrentTransformerasper PWD specification for electrical Works ,ISI marked as perIS 2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCT shallbebroughtoutsuitabletoaterminalblockwhichshallbe easieraccessiblefortestingandterminalconnection,withall necessarysupportinexistingpanelincludingconnectionetc.as requiredCurrenttransformerRingTypeTapeWound/ResinCast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm (minimum),includingallnecessarysupportinexistingpanel includingconnectionetc.asrequired.Allasperpreapprovedby Engineerin-charge.AllasperpreapprovedbyEngineerin-charge. Foradditionaltechnicalparametersofproducts/work,refer Annexure \"A\" attached with this BSR . |
| 346 | C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA |
| 347 | C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA |
| 348 | Providing & Fixing ofCam operated rotary (Auto/manual) switches onexistingpanelwith2wayandoffpositionusinghighgrade engineeringmaterialtointernationalstandardswithcamassemblyinsulationofglassfilledpolyamidewithhightrackingindex.For reliable and stable electrical and mechanical endurance double butt contactswithsilverbi-metaloncoppershouldprovidedcontact assemblyis of operating temp range-25 degree C to55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanicallyminimum50000operations@300cycles/hourand electrically10,000operationsat100%rateddutyfor100cycles/ hourincludingmakingconnectionetc.asrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 349 | 10 AMP |
| 350 | 16AMP |
| 351 | Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947withintegralcircuit,IP65abovepanel&IP20terminal block,Approx.bodydiaforpanelnot lessthen20mm,lengthmin. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR . |
| 352 | Red/yellow/Blue |
| 353 | Red/Gree/ white Colour |
| 354 | Red/Gree/ white Colour |
| 355 | Red/Green |
| 356 | Providing&FixingofflushheadpushbuttonactuatorsIEC60947withintegralcircuit,IP65abovepanel&IP20terminalblock, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze forLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,includingconnectionetc.asrequired.AllasperpreapprovedbyEngineerin-charge.Foradditional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR |
| 357 | Non luminous type |
| 358 | Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 withonesideantiskidabberationmarksandpastingthe matwithsyntheticrubberadhesiveasrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 359 | 33 KV,class C 3 mm thick with proof voltage 36 KV AC (rms) for3 min. and Break Down Voltage 65 KV AC (rms) |
| 360 | SITCof3/4polecurrentlimitingMouldedcasecircuitbreaker (MCCB)madeofflameretardent&heatresistantmaterialhaving followingcurrentrating,shortcircuitbreakingcapacityat440/415 V,50Hz;O/L&S/Csettings,conformingtoIS/IEC60947P-2 :2003withfrontfaceandcentralisedadjustable,tripfree mechanisum,truecontactpositionindicator,lineload interchangeability, designed for both horizontal&vertical mounting withoutanyadverseeffectonelectricalperformance,suitablefor operationupto55degreeandwithoutderatingupto40degree,pollution degree 3, having positive isolation capability, push(test) totrip,triptimelessthen10msunders/ccondition,Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock&rotaryhandle,includingmakingconnectionsetc.as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 361 | 630 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 362 | Extended Rotary Handle |
| 363 | Mechanical Interlocking kit |
| 364 | Auxiliary + Trip alarm contact |
| 365 | Spreaders for 630A, 4 Pole MCCB |
| 366 | SITCofDrawouttype3/4poledoorinterlockAirCircuitBreaker (ACB)asconformingtoIS/IEC60947P-2:2003inexistingLT panel suitable for LT installation 440 V, 50 Hz and having adjustable overloadshort-circuit,Instantaneous,earthfault(LSIG)withseparateLEDindicationforeachtypeoffaultshallconfirmtoEMI/ EMC test, LCD/LED display, last 10 trip history, provisionofZSI, Communication, Power metering module, Thermal memory , trip free mechanisum,suitableforambient50degreeandutilization catagaryB.Inbuiltelectrical&mechanicalantipumpingfeature, 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw(1sec),Uimp-12KV,breaktimenotmorethen25ms. Provisionforelectrical&mechanicalinterlockbetweenACBs, Min.electricaloperation10000upto2000Aratingand5,000for 2500Ato4000A.includingmakingconnections,testingetc.as required. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineerin-charge.Foradditionaltechnicalparametersofproduct/ work refer Annexure \"A\" attached with this BSR |
| 367 | 1600 A Rating ,50 kA |
| 368 | SupplyandfixingoffollowingaccessoriesforAircircuitbreaker (ACB)compatiblewithMAinACBOEMasperPWDspecification forelectricalWorks,conformingtoIS/IEC60947P-2:2003 includingmakingconnectionetccompleteinallrespect.OEMshall havesubmitNABL/CPRI/ERDAaccrediatedlabtypetest certificatebeforeexecution.AllasperpreapprovedbyEngineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR . |
| 369 | Shunt Trip Release |
| 370 | Under voltage Release |
| 371 | Microswitch for Indication |
| 372 | Operation Counter |
| 373 | Door Interlock |
| 374 | Auxiliary Contact 4 NO + 4 NC |
| 375 | Breaker Control Switch (TNC) |
| 376 | Providing& Fixing of IP54 microprocessor based 3CT’s for all 3 phasesensingcompensationpowerfactorcorrectionrelaySize 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having3CTsensing,sensitivityupto50milliamp secondarycurrent,selfanalysingautoc/ksettingaccordingto targeted power factor setting, the relay shall have digit displayunit fordisplayofrealpowerfactor,targetedpowerfactor,lag/lead capacitorswitchingstatus,alarmoutputforundercurrent,over current, insufficient compensation, communication interface with RS 485,indication of switching onunits, auto/manual status, and shall haveoverloadprotection,novoltrelease,havingmultiparameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay includingmakingcoonectionwith1.5Sq.mmcopperwireetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 377 | 12 to 14 stage |
| 378 | Providing&FixingofselfhealingIP20MPPtypeshuntcapacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1&2inexistingpanelorparallelwithloadterminals,thecapacitor shallbefittedwithdischargeresistors,pressuresensitive disconnector(PSD)andshallhavedissipationfactorlessthan 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min overcurrentcapacity1.8timesratedcurrent&peakinrushcurrent min.300timesofratedcurrent,llifeexpectancygreaterthan 100000hrs(tempclass-25D)in440V/480VCapacitorandfor 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR . |
| 379 | HeavydutyThreephase440V,50Hzcylindricaltypecapacitor (Bank) |
| 380 | Providing&Fixingof440Volt3polecapacitor(AC6B)duty contactor with 3 no. early make and post break auxiliary contacts in serieswithquickdischargedampingresistors/reactorstolimitthe inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1:2000,insulationvoltage1000V,impulsewithstand voltage8KV,Dinrailmountingtypeincludingmakingconnections, testingetc.asrequired.suitableforfollowingcapacitycapacitor bank.All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR . |
| 381 | up to 6 KVAR |
| 382 | 10 KVAR |
| 383 | 15 KVAR |
| 384 | 25 KVAR |
| 385 | 50 KVAR |
| 386 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kAbreakingcapacity(B/C/Dtrippingcharacteristicaspertypeof loadandsiterequirement)4KVimpulsewithstandvoltage,ISI markedIS8828(1996)/conformingtoIEC60898-12002,IEC 60947-2,lowwattlosses,tripfreemechanisum,energylimitingofclass3asperIEC,minimumphaseterminationcapacityof 35sq.mm. , conductor line load reversibility , IP 20 contact protection andfittedinexistingdistributionboard/sheets,minimumelectrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A&aboveratingincludingmakingconnections,testingetc.as required. OEM shall have submitNABL / CPRI / ERDA accrediated labtypetestreports&AllasperpreapprovedbyEngineerin-charge.Foradditionaltechnicalparametersofproduct/workrefer Annexure \"A\" attached with this BSR |
| 387 | Triple pole MCB(With B/C curve trippingCharacteristics), 6 A to 32 A rating |
| 388 | 50/63 A rating |
| 389 | 125A rating |
| 390 | Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating |
| 391 | Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating |
| 392 | SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. |
| 393 | 90KW |
| 394 | 30KW |
| 395 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ontrolMCBwithpanelwithallaccessorieswithfollowing rating : 11KW |
| 396 | S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ontrolMCBwithpanelwithallaccessorieswithfollowing rating : 15KW |
| 397 | SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried. |
| 398 | SupplyanderectionofGalvanizedIronpolewith galvanizingdone insingledipping(AveragecoatingthicknessMinimum65Microns) continuouslytaperedpoleshavingOctagonal/Circularcross-sectionsdesignedtowithstandthemaximumwindspeedasperIS 875,Thepoleshaftshallbemadefromsheetsteel(HTSteel ConformingtogradeS355JO)andconfirmingtoBSEN10025and shall be continuously tapered with single longitudinal welding. There shallnotbeanycircumferentialwelding.Theweldingofpoleshaft shallbedonebySubmergedArcWelding(SAW)process.pole shaftsshallbeprovidedwiththerigidflangeplateofsuitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to thepoleshaftattwolocationsi.e.frominsideandoutside.The octagonalPolesshallhavelockabledoorofapproximate500mm length at the elevation of 500 mmfrom the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) insidethepoleatdooropeningforcableconnectionoffollowing lengthanddimensionaspertableP-01withbaseplateand foundationboltontheExistingcementconcretefoundation.Allas perpreapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR . |
| 399 | 7 Mtr., Poles with Octagonal Cross Section |
| 400 | SupplyandFixingofPoleOEMfabricatedhotdippedgalvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR . |
| 401 | Single arm overhang |
| 402 | ProvidingandLayingRCCFoundationforOctagonal/Conical StreetLight poles, High mast Poles as per Drawingattach at TableP-4withFollowingProcedure&Allasperpreapprovedby Engineer in-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . A)ExcavationofPitforFoundationSizeuptorequireddepthfrom Ground levelB)DressingofPitandDrystonepitching200mmthickincluding supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D)ReinforcementforR.C.C.workwithTMTbarsincluding straightening,cutting,bending,placinginpositionandbindingall complete. E)Centringandshutteringincludingstrutting,proppingetc.and removal of form work for Footing and Pedestal F)Providing&Fixingof2no.RequiredSizePLBHDPEPipe& Foundation Bolt with template as per OEM Recommendations. G) Providing and LayingReinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face. |
| 403 | Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. |
| 404 | Providing&FixingofIK08,IP66protectedLEDStreetLight Luminaireonexistingbracket/pole.Fixturemadeofpowdercoated singlepiecepressurediecastaluminummaterialwithheat dissipationfinsonhousingwithUVstabilizedPC(UVstablization reportsubmittedforUVcover)/ToughenedGlasscoverand secondarylensoneachLED&shouldbeSMDtypeof3to5watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with HighvoltageCutoff@>=300VACandAutoresettingSafety, Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. TheluminaireshallbeBIScertifiedandTrademarkcertified.Life ExpectancyEqualormorethan50000burninghrswithMinimum 70%lumenmaintened,CRI>70andCCT5700K+355K.Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside drivercompartment.drivershouldbePhasetophaseprotectionof 440Vfor4Hrs.ManufacturesWordMark/Name Engraved/Embossingondiecasthousingtoallow traceability/authenticity.FixtureshallbeASPERIS10322 Complianced.OEMMusthaveitsowninhouseNABLlabsetupfor alltestingfacilitiesforLEDfixtures.(LM79/LM80)Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 405 | LED Street Light fixture with Minimum lumen output 8700 lm |
| 406 | Providing&FixingofIP-65protectedimpactresistant polycarbonate/Polystereneenclosureswithknockoutforcable entry/outincludingfixingwithnut,bolt,fatneretcasrequired complete in all respect of following sizes.All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 407 | 180 x 180 x 91 mm |
| 408 | Providing&FixingofStreetlightbracketmadeoutfromfollowing size of \" B \" class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. asrequired.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 409 | 32 mm Dia. |
| 410 | Providing&FixingofIK08IP-66protectedhighpowerLEDflood lightsystemwithsinglepiecePressurediecastaluminiumhousing, toughenedglassdiffuserwithsuitablelensesonLEDtoachieve variousbeamangles,ofhighpowerLEDof3to5watteach. Integrated potted driver as a unique BIS R numberhaving efficiency more than 85 % and in compliance to BIS certified and Trade markcertificate.TheSystemlevelLuminaireefficacy>=125lm/wt.LED driverInputVoltageAC120to270VACwithHighvoltageCutoff @>=300VACandAutoresettingSafety.PowerFactor>0.95, THD(I)<10%,drivercurrent<=750mA.drivershouldbePhaseto phaseprotectionof440Vfor4Hrs.ElectricalConnector,Surge ProtectionMin>=4KVinternaland10KVexternalbutinsidedriver compartment, System life of 50000 Burning hours with 70% of Initial Lumensmaintained,CRI>70andCCT5700K±355K.ManufacturesWordMark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shallbeIS10322Complianced.OEMMusthaveitsowninhouse NABLlabsetupforalltestingfacilitiesforLEDfixtures.(LM79/LM80)Certificate/reportwithliablewarrantyof product/accessoriesfromOEMshallbesubmitted.Allasperpre approvedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR . |
| 411 | High Power LED Flood Light Minimum lumen output 10000 lm |
| 412 | Providing and fixing in position lightening arrester set complete with 600mmx600mmx6mmthickG.I. earthingplate embeddedbelow groundinearthlingpitat3.5metrdepth,G.I.stripofsize 25mmx5mm thick from earthing plate to top of Over head tank, G.I. FinialmadeofGIbar25mmdiaand2mlongfixedontopofOH tankandconnectedtoGIstrip.Theearthlingsetshallcomplyof IS:3043 complete in all respect as per specification and the direction of the Engineer. |
| 413 | Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Washers, Electrical Taps, HT Tap, Danger Plates, 4.5 Kg. CO2 type portable fire extinguisher for Panel Room , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per site requirements. |
| 414 | 33KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,coversect. |
| 415 | From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W) x400 (H) x 600 (D) |
| 416 | Supplyof indoortype floor mounted metal clad, incoming 3.3 KV VCB panel equipped with following switchgears and accessories. 1. 3.3 KV, analog/digital type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 7 KV on incomer 2. Ammeter, analog type, selector switches for ammeters. 3. Microprocessor based numerical relay with O/L, E/F and S/C protection. 4. Set of dual core dual ratio 3CTs of suitable ratio with sec of 1 A of 15 VA burden and accuracy Class –0.5 for metering and class 5P10 for protection 5. Multifunction Meter , Incoming from 630 to 1250 Amp. VCB |
| 417 | Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 3.3 KV Bus Coupler VCB panel equipped with following switchgears and accessories. Bus Coupler from 630 to 1250 Amp. VCB |
| 418 | 1. 3.3 KV / 110 Volts PT Class0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-3.3 KV), analog/digital type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 3.3 KV on 2. Ammeter analog type, selector switches for ammeters. 3. Microprocessor based numerical relay with O/L, E/F and S/C protection. 4. Set of dual core dual ratio 3CTs of suitable ration with sec 1 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection 5. Multifunction Meter outgoing, Outgoing from 630 A to 1250 A VCB |
| 419 | 3.3 KV HT FMCA Digital Soft Starter Panel with reactorfor HT VT Motor ,--Inddor Type, Metal enclosed compartmentalized, Short Circuit withstand & duration (Sec.) - 5KA for 1Sec, Rated 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X, Control & Protection Sypply - 110VDC, 10KV for 1min power frequency, 2 Pole Vacuum Contactor 400A, Bus Bar - Copper, FMCA Coils type - Air Core as per IEC 60076-6,Insulation - Class F, Temp. rise limited to class B. Coil material - Copper conductor is wound on Fiberglass bobbin, No of Tappings - 5 nos., Single Power cable Based. |
| 420 | 3.3 KV HT FMCA Digital Soft Starter Panel with reactorfor HT VT Motor ,--Inddor Type, Metal enclosed compartmentalized, Short Circuit withstand & duration (Sec.) - 5KA for 1Sec, Rated 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X, Control & Protection Sypply - 110VDC, 10KV for 1min power frequency, 2 Pole Vacuum Contactor 400A, Bus Bar - Copper, FMCA Coils type - Air Core as per IEC 60076-6,Insulation - Class F, Temp. rise limited to class B. Coil material - Copper conductor is wound on Fiberglass bobbin, No of Tappings - 5 nos., Single Power cable Based. |
| 421 | 3.3 KV HT FMCA Digital Soft Starter Panel with reactorfor HT VT Motor ,--Inddor Type, Metal enclosed compartmentalized, Short Circuit withstand & duration (Sec.) - 5KA for 1Sec, Rated 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X, Control & Protection Sypply - 110VDC, 10KV for 1min power frequency, 2 Pole Vacuum Contactor 400A, Bus Bar - Copper, FMCA Coils type - Air Core as per IEC 60076-6,Insulation - Class F, Temp. rise limited to class B. Coil material - Copper conductor is wound on Fiberglass bobbin, No of Tappings - 5 nos., Single Power cable Based. |
| 422 | 3.3 KV-HT APFC Panel for HT Motor ,- 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized. (550KVAR) |
| 423 | 3.3 KV-HT APFC Panel for HT Motor ,- 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized. (450KVAR) |
| 424 | 3.3 KV-HT APFC Panel for HT Motor ,- 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized. (160KVAR) |
| 425 | 3.3 KV-HT APFC Panel for HT Motor ,- 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized. (200KVAR) |
| 426 | Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 3.3 K.V.(UE) confirming IS :7098 P - 2withH4-GradeelectrolyticaluminiumconductorconfirmingtoIS:8130 class-2ofpurity>99.6%,InsulationScreening:Extruded SemiconductingCompoundfollowedbyhelicallywrappedCopper Tape,round/flatstriparmouringofcables,Inner/outersheath PVCtypeST-2confirmingtoIS:5831inexistingRCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have it\"s own in houseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 427 | 3 core 240 Sq.mm (3.3KV, XLPE, ARMORD, UE) |
| 428 | 3 core 240 Sq.mm (3.3KV, XLPE, ARMORD, UE) |
| 429 | 3.3 KV NGR Control Panel,3.81 Ohms with100 A, 10 Sec Capacitywithsupporting Structure for installation.Hence NGR of 3.81 Ohms is required with capacity of 1000 Amp 10 sec.Complete as per technical specifications and as directed by Engineer in charge. |
| 430 | SITCofHT33KV,3Phase,50Hz,totallyenclosedmetalcladSF6 switchgearhavingrupturingcapacityupto630Amps,OutdoorNon ExtensibleFixedType(IP54),RMU(Ringmainunit)comprisingof manuallyoperatedLoadBreakSwitchandmanualchargingfixed-typeVacuumCircuitBreakerasperrequirement,insiderobotically welded stainless steel grade 304 (Non Ferrite Non Magnetic Grade) tankhavingofminimumthickness2mmwithIP67Degreeof ProtectionandenhancedBILof170kVpinternallytomanage voltagesurges.RMUshouldbeprovidedwithinternalbusbars,as wellasearthingbusbarsofelectrolyticgradecopper,padlock provisions&completewithallaccessories.TheRMUshallbetype testedforInternalarctestofAFLR25kA/1secfortankandcable chamber as per IEC62271-200. RMU shall have on-site-repair ability features such as site replaceable bushing/ coupling/ mechanism and gasrefillingatsite.Theearthingbusbarshallbeprovidedinside eachcablecompartmentforsolidearthingofcablesheilds.The outerhingedmaindoorshouldcoverentirefrontofswitchgear including cable doors for providing better ingress protection. The unit shallincludethefollowingwithallnecessarystandardfittingsas required at site.Load Break Switch module consisting of following accessories : 33kV,630AmpLoadBreakSwitchmoduleandintegratedearthing switch, both with full making capacity. ShortCircuitwithstandcapacity-25kA/3-sec,MakingCapacity– 62.5 kAp, Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 Nos,touch-proof screen separable termination kit (push on type) VCBBreakermoduleconsistingoffollowingaccessories:33kV, 630 Amp fixed-type Vacuum Circuit Breaker module for making and breakingoffaultcurrentalongwithdisconnector+EarthSwitchof full making capacity. Short time current breaking capacity - 25KA/ 3 sec, Making Capacity – 62.5kAp, Auxiliary contacts - 1NO + 1NC VCBoperatingsequencemustbeO-0.3Sec-CO-3Min-COand mechanical endurance confirms for minimum 10000 operations. touch-proof screen separable termination kit (push on type) Numericalbasedself-poweredOC+EFProtectionRelay,providing Over Current (min. setting 20%), Earth-Fault (min. setting : 10%) 03Nos50-100/1,2.5VAepoxyinsulated,RingCoreCTsfor protection(Acc.CL5P10),installedawayfrombushingstoprevent saturationofcore.(CTRatiomychangeaccordingtochangein Load) AllmodulesshouldhaveSuitablesitereplaceablecablebushings situatednotbeyond300mmfromcable-covertoalloweaseof access for installation/ testing/ replacement purposes. Cable covers with self-Interlocking mechanism between doors, earth switch, disconnector & VCB Capacitive voltage indication fixed type system (i) Capacitive voltage indication fixed type VPIS 28-45 kV (ii)OneNo.OperatingHandleforManualOperationandoneno. manometer (iii)SafetyInterlocksShallbeprovidedasperrelevantIEC/IS Standards and Manufacturer’s directions (iv) Above switchgear shall confirm to all relevant IEC/IS Standards. (v) Vacuum interrupter should be of same make as RMU (vi) Cable bushing should be replaceable at site. (vii)Minimum4moduleshouldaccommodateinonetanktoavoid multiple coupling at site. |
| 431 | Non-ExtensibleType4wayRMUwith2no.VCB&2No.LoadBreak Switch |
| 432 | Design,Manufacture,Supply,Installation, TestingandCommissioningofIndoortypePLC Panelofsizeapprox.800mmX500mmX 2000mm(LBH),Fabricatedoutofmin.2mm thickCRCAsheetcompletewithlatest configuration,necessaryprogrammingsoftware forPLC&SCADAandcomprisingofall accessories not limited to the following: DI 102No. DO 98No. AI 22No. AO 16No. MCB 16A DP 2No. MCB 6A DP6No. SMPS 100-240VAC/ 4.5A / 24 VDC 1No. Selector Switch (uto/Manual) & Local / Remote2No. Control Relays1Lot Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with1No.Electronic Hooter1No. Control Transformer 200VA1No. Emergency STOP Push Button1 No. Panel Cooling Fan & Filter2No. Panel Light with Door Switch, 7W1No. Control Indication Lamp for 24VDC, 220VAC3No.Push Button3No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc1Lot PanelHardware,lugs,terminations,ferruls, name plate Ect.1Lot UTILITY SOCKET 16A, 3 PIN2No. HMI Display 12 Inch, Colour1No. Isolators Dual Output, 24VDC1Lot |
| 433 | Quad-bandGPRS/IOT/VPN/GSM/CLOUD 3G/4G/5G modemwithEthernetbridge/router/ serial server (RS232/485) interface. |
| 434 | SITCofIntelligentManageableEthernetSwitchesproviding24x 10/100/1000FastEthernetports-and2dualpurposeuplink (provisionforCopper/FibreGigaconnectivity)withLANbased Software.TheLANbasedS/Wsupportsenhancedintegrated security,includingNetworkAdmissionControl(NAC),advanced qualityofservice(QoS),availabilityandscalablemanagementto enable new converged applications |
| 435 | Providing,installation,testingandcommissioningofONLINEUPS SYSTEM,SinglePhase230V,50Hzwith2hourbackupSMF battery bank as per specification |
| 436 | 2 KVA |
| 437 | ProvidingandlayingStranded/FlexibleAnnealedeBarecopper conductor,XLPE/PVCinsulatedsuitablylaiduptogetheroverall polystertapedAl(innersheatedGISteelwireMylar/Drainwire) alongwithATCdrainwire,round/steelarmouredoverallPVC sheathed (ST-1) overall screenedCore armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. |
| 438 | 24 CORE, 1.0 sq. mm. |
| 439 | 4 CORE, 1.0 sq. mm. |
| 440 | ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. (2 Pair * 0.75SQMM) |
| 441 | Providing,Installation,TestingandCommissioningofUltrasonic LevelTransmitter:Principle:TimeofFlight/SensorMOCPP/ PowerSupply:24VDC/Output:4-20mA/Display:Integral displayforprogrammingandDisplayReading/IP66/Accuracy ±1% |
| 442 | 0 - 8 Mtr. |
| 443 | Providing,Installation,TestingandCommissioningofPressure Transmitter : Range:0-10Bar / Power Supply:24 V DC / Output: 4-20mAwithHART/Diaphragm:SS316L/ProcessConnection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67 |
| 444 | Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material ofsensorandotherwettedparts:SStype316,Housing:Diecast aluminum,Switchtype:Microswitch,Repeatability:±1%ofspan, Switch Contacts: 2 NO + 2 NC |
| 445 | Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes,Probeinsulation:Teflon,Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum |
| 446 | Rigid for lengths from 3 - 10 Mtr. |
| 447 | Supply,Installation,TestingandComissioningofISOcertified companymadeAirCooledHiWallsplittypeAirconditionerswith lateststarratingsystemasperBEEamendeduptodatecomplete withIndoorunit(IDU),Outdoorunit(ODU),surface/concealed copperRefrigerantpipingwithinsulation(closedcellelastomeric nitrile rubber tubular pipe section)upto 3 Mtr (IDUto ODU), copper powercableupto3.5Mtr(IDUtoODU),R-32/R-410/R-407Green Refrigerant,wirelessRemotecontrol,suitableforworkingbetween 180-260Vwithlow&highvoltagecutoffand50hz,1phaseAC supplycapableofperformingcooling,dehumidification,air circulation of following capacitywith Scroll / rotarycompressor. Min 5 year OEM warranty both compressor and PCB. NABL accredeated asperIS/ISO/IEC17025standards/CPRI/ERDAlabtesting reportsasperIS1391(Part-2)2018withOEMcertificatemust submittedtoengineerin-charge.Allasperpreapprovedby Engineer in-charge.All asper pre approvedbyEngineerin-charge. Foradditionaltechnicalparametersofproducts/work,refer Annexure \"A\" attached with this BSR . Non InvertorType1.8/2.0TRwith3starratingofBEE(ISEERnot less then 3.5 ) |
| 448 | Supply, Installation, testing and commissioning of SCADA System at MasterControlCentrecompletewithPCserver,monitor, communication modules, printers, 2 Nos. of 60\"LED Display of latest resolution and configuration, 4 Nos of 32\"\" Operator console ( 1 No. of Engineering, 1 No. of operator console, 1 No. of Historical and 1 No. of Web Server) including control desk, chairs, storage racks etc., requiredhardware,softwarecompletewithallaccessoriesandin line with Technical Specification. |
| 449 | Providing,installation,testingandcommissioningofONLINEUPS SYSTEM, 3 Phase 415 V, 50 Hzwith2 hour backup SMF battery bank as per specification |
| 450 | 10KVA |
| 451 | LocalDataLogger-PCbasedDataAcquisitionSystemwithSAM WILicenseSoftwaresuitableforStoring,Logging,Reporting, PrintingdatafromaboveofferedAnalysers.PCwithspecifications as under: Intel Core i5 5th Generation Processor, 8 GB RAM, 1 TB HDD+250 GB SSD, CD/DVD Combo Drive, 32\"Monitor, Minimum 6 USBports(USB3.0/2.0),WINDOWS-7orhigherCompatiple Operating System, standard keyboard, mouse with pad and with A3 & A4 Color Laser printer. |
| 452 | CentralDataLogger-PCbasedDataAcquisitionSystemwithXR Premium License Software suitable for Storing, Logging, Reporting, Printingdata,Validationandcommunicatingwithaboveoffered LocalDAS.PCwithspecificationsasunder:IntelCorei55th GenerationProcessor,8GBRAM,2TBHDD+250GBSSD, CD/DVDComboDrive,32\"Monitor,Minimum6USBports(USB 3.0/2.0),WINDOWS-7orhigherCompatipleOperatingSystem, standardkeyboard,mousewithpadandwithA3&A4ColorLaser printer. |
| 453 | Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document. |
| 454 | Solar panels more than 10 KW and up to 50 KW at a single location. |
| 455 | Dholpur |
| 456 | Kotra |
| 457 | Jugarwar |
| 458 | Kishangarbas |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail