Drinking Water Supply and Sanitation Government Departments Closing in 72 days TDR #49065013

Work Of “Construction Of Intermediate Cwph At Kotra (Baseri), Laying Of Clear Water Transmission Main From Kotra To Naroli, Nadbai Via Junction 2 At Naroli, Ips Nadbai, Nagar, Ramgarh, Kishangarhbas Tijara (Jairolı) And Bhiwadi, From Kishanbas To Mandawar

Issued by Government Departments · dholpur, Rajasthan
Tender Value
2386.57 Crore
Estimated cost
Bid Submission
16 Sep 2026
72 days left
EMD
47.73 Crore
Bank guarantee accepted
Document Fee
1.18 Lakhs
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
dholpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Work of “Construction of Intermediate CWPH at Kotra (Baseri), laying of Clear Water transmission main From Kotra to Naroli, Nadbai via junction 2 at Naroli, IPS Nadbai, Nagar, Ramgarh, Kishangarhbas Tijara (Jairolı) and Bhiwadi, from Kishanbas to Mandawar and Upto Behror, from Naroli Jn to KNP Bharatpur and Naroli Construction of CWR and Intermediate Pump Houses and Offtakes Construction of terminal CWRS at Bhiwadi and Behror inculding all alied works under Jal Jeevan Mission with 10 years O&M including one year defect liability period (Chambal Alwar Project Package-II) on Hybrid Annuity Model (HAM)”

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 11-Jun-2025 Corrigendum6 Date 28-Jul-2025
2 11-Jun-2025 Corrigendum5 Other 28-Jul-2025
3 07-Jul-2025 Reply of Pre Bid Queries Other 28-Jul-2025
4 07-Jul-2025 Corrigendum 7 Other 28-Jul-2025
5 22-Jul-2025 Corr8 Date 08-Sep-2025
6 21-Oct-2025 Corrigendum10 Date 29-Dec-2025
7 23-Dec-2025 Corrigendum11 Date 16-Feb-2026
8 03-Sep-2025 Corr9 Date 27-Oct-2025
9 11-Feb-2026 Corrigendum 12 Date Change Date 16-Apr-2026
10 14-Apr-2026 Corrigendum13 Date 18-Jun-2026
11 11-Feb-2026 Corrigendum 12 Date Change Date 16-Apr-2026
12 23-Dec-2025 Corrigendum11 Date 16-Feb-2026
13 21-Oct-2025 Corrigendum10 Date 29-Dec-2025
14 03-Sep-2025 Corr9 Date 27-Oct-2025
15 22-Jul-2025 Corr8 Date 08-Sep-2025
16 07-Jul-2025 Corrigendum 7 Other 18-Jun-2026
17 07-Jul-2025 Reply of Pre Bid Queries Other 18-Jun-2026
18 11-Jun-2025 Corrigendum6 Date 28-Jul-2025
19 11-Jun-2025 Corrigendum5 Other 18-Jun-2026
20 14-Apr-2026 Corrigendum13 Date 18-Jun-2026
21 11-Feb-2026 Corrigendum 12 Date Change Date 16-Apr-2026
22 23-Dec-2025 Corrigendum11 Date 16-Feb-2026
23 21-Oct-2025 Corrigendum10 Date 29-Dec-2025
24 15-Jun-2026 Corrigendum 14 and office order Date 16-Sep-2026
25 03-Sep-2025 Corr9 Date 27-Oct-2025
26 22-Jul-2025 Corr8 Date 08-Sep-2025
27 07-Jul-2025 Corrigendum 7 Other 16-Sep-2026
28 07-Jul-2025 Reply of Pre Bid Queries Other 16-Sep-2026
29 11-Jun-2025 Corrigendum6 Date 28-Jul-2025
30 11-Jun-2025 Corrigendum5 Other 16-Sep-2026

BOQ

Name of Work:Work of “Construction of Intermediate CWPH at Kotra (Baseri), laying of Clear Water transmission main From Kotra to Naroli, Nadbai via junction 2 at Naroli, IPS Nadbai, Nagar, Ramgarh, Kishangarhbas Tijara (Jairolı) and Bhiwadi, from Kishanbas to Mandawar and Upto Behror, from Naroli Jn to KNP Bharatpur and Naroli Construction of CWR and Intermediate Pump Houses and Offtakes Construction of terminal CWRS at Bhiwadi and Behror inculding all alied works under Jal Jeevan Mission with 10 years O&M including one year defect liability period (Chambal Alwar Project Package-II) on Hybrid Annuity Model (HAM)”
Sl. No. Item Description
1Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
2200 mm dia
3250mm dia
4300 mm dia
5350 mm dia
6400 mm dia.
7450 mm dia
8500 mm dia
9600 mm dia
10800 mm dia
11900 mm dia.
12Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; (excluding earthwork, internal lining and outer coating).Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
13OD 813 mm dia and thickness 7.1 mm
14OD 914 mm dia and thickness 8.0 mm
15OD 1067 mm dia and thickness 8.8 mm
16OD 1118 mm dia and thickness 8.8 mm
17OD 1422 mm dia and thickness 10.5 mm
18OD 1422 mm dia and thickness 12.5 mm
19Outer dia of pipe 1626 mm and 14.2 thickness
20OD 1727 mm dia and thickness 12.5 mm
21OD 1727 mm dia and thickness 14.2 mm
22OD 1727 mm dia and thickness 17.5 mm
23OD 1829 mm dia and thickness 10.9 mm
24OD 1829 mm dia and thickness 12.5 mm
25OD 1829 mm dia and thickness 14.2 mm
26OD 2032 mm dia and thickness 16 mm
271524 mm dia/14.2 mm th
28OD 219.1 mm dia and Thickness 4.5 mm
29OD 273 mm dia and thickness 5.0 mm
30OD 323.9 mm dia and thickness 5.6 mm
31OD 457 mm dia and thickness 6.3 mm
32OD 610 mm dia and thickness 8.8 mm
33OD 711 mm dia and thickness 8 mm
34OD 1016 mm dia and thickness 8.8 mm
35OD 1219 mm dia and thickness 10 mm
36Providing and applying Spray applied, 100% Solids (Solvent free) Two Component PU ( Polyurethane) coating as per AWWA C222 Standard on external surface of M.S. Pipe including preparation of pipe outer surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2 including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Minimum dry film thickness of coating shall be 1000 micron
37Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Liquid Epoxy shall be NSF/WARS approved for drinking water and minimum thickness of lining shall be 406 microns.
38Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil
39In All Typeof Soil
40Add extra for trenches for every additional lift over item no 4.1
41Above 1.5 mtr and up to 3.0 mtr.
42Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each depositedlayer by ramming, watering etc.and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required
43Ordinary rock
44Hard rock (Blasting prohibitated)
45Add extra for trenches for every additional lift over item no 4.1
46Above 1.5 mtr and up to 3.0 mtr.
47Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
48Providingandlayinginpositionspecified grade of reinforced cement concrete includingcuringcompactionfinishingwith rendering in cement sand mortar 1:3 (1- Cement:3-coarsesand)and making good the jointsexcludingthecostofcentering, shuttering and reinforcement.All work up to plinth level :
491:2:4(1-Cement:2-coarsesand:4-graded stone aggregate 20 mm nominal size). ( Encashing of Pipe in River/ thrust block))
50Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix( Encashing of Pipe in River/ thrust block))
51Providingandfabricatingreinforcementfor R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.
52Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level.
53Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proofKinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(ammended up to date) Body, High pressure cover , Low pressure cover, Cowl andJoint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float- LP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & coverinside and outside fastners - CS/ Galvenised steel, Outlet of big orifice will have a screen to prevent Tamper of float,with DI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amendedupto date) PN 1.6 ratings Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work.
54Class PN 1.6
5550 mm dia
5680 mm dia
57150 mm dia
58200 mm dia
59Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge.
60Air valve pillarfor airvalves size of 80mmdia
61Air valve pillarfor airvalves size of 150mmdia
62Air valve pillarfor airvalves size of 200mmdia
63Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
64Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
65100 mm dia
66150 mm dia
67200 mm dia
68250 mm dia
69300 mm dia
70500 mm dia
71600 mm dia.
72700 mm dia. With Gear
73800 mm dia. With Gear
74Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amended up to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings- bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in- charge.\"Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
75Class PN 1.6, Manually Operated with Gear
76350 mm dia
77600 mm dia
78800 mm dia.
79900 mm dia.
801000 mm dia.
811100 mm dia.
821400mm dia.
831600 mm dia
841800 mm dia
852000 mm dia
861300 mm dia.
871500 mm dia.
881600 mm dia
89500 mm dia
90600 mm dia
91Providing, lowering,aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioningand as per technical specifications and direction of Engineer In-Charge. Class PN 1.0
92100 mm dia.
93150 mm dia.
94200 mm dia.
95250 mm dia.
96300 mm dia.
97350 mm dia.
98400 mm dia.
99500 mm dia.
100600 mm dia.
101Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specificationscompleteofthefollowing sizes including all jointing material, cost of alllabour,testingand commissioning Technical Specifications and as per direction of Engineer.
102700 mm dia.
103800 mm dia.
104900 mm dia.
1051000 mm dia.
1061100 mm dia.
1071400mm dia.
1081600mm dia.
1091800mm dia.
1102000mm dia.
1111300 mm dia.
1121500 mm dia.
1131700 mm dia.
1141400 mm dia.
1151600 mm dia.
116Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work.
117Class PN 1.0
118200 mm
119Construction of RCC Air valve chamber fordifferent typeof valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concreteworkcompleteinallrespectasper specificationsand standard drawings and as directed by Engineer-in-Charge.
120For Class-AA loading
121Air valve chamber of size1.05m x1.4m x2.42m for air valve size of 150mm
122Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concreteworkcompleteinallrespectasper specificationsand standard drawings and as directed by Engineer-in-Charge.
123For Class-AA loading
124Sluice valve chamber of size 1.13 m x0.85 m x1.325 m- for pipe size-upto 100 mm
125Sluice valve chamber of size 1.17m x 0.95m x1.47m for pipe size-from 125-to-150mm
126Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm
127Sluice valve chamber of size 1.39m x1.43m x2.245m for pipe size-from 350-to-450mm
128Sluice valve chamber of size 1.61m x1.75m x2.85m for pipe size-from 500-to-700mm
129For in-campus Valve Chambers
130Sluice valve chamber of size1.17m x0.95m x1.415m for pipe size-from 125-to-150mm
131Sluice valve chamber of size1.26m x1.185m x1.82m for pipe size-from 200-to-300mm
132Sluice valve chamber of size1.61m x1.75m x2.72m for pipe size-from 500-to-700mm
133Valve Chamber size2.50X2.10 X2.10Valve size 800 mm to 900 mm
134Valve Chamber size2.80X2.50X2.50 Valve size 1000 mm to 1200 mm
135Valve Chamber size3.00X2.50 X2.80Valve size 1300 mm to 1500 mm
136Valve Chamber size3.00X2.75X3.10 Valve size 1600 mm to 1800 mm
137Valve Chamber size3.00X3.00X 3.30 Valve size 1900 mm to 2000 mm
138Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications: Body- Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030, Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021 Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, BearingBush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2.Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied both inside and outside . Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
139Plunger Type Flow Control Valve
140200mm dia
141250mm dia
142300mm dia
143350mm dia
144400mm dia
145600mm dia
146800mm dia
147Supply and Pushing of MS casing pipe of specified thickness by trenchless method adopting micro-tunnelling or any suitable mechanical technology or technology approved by Railway below ground at all depth under running traffic condition as per railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipment’s for completion of works, mobilizing ofmachineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (upto 3 metre depth) with proper protection at three sites with shoring sheets and ISMB\"s. Providing MS cutting edges for front shield and Constructing thrust bed at designated level. Necessary de-watering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Railway Authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per requirement and as per approved by railway authorities, specification and the direction of the Engineer. (Protective coating/ lining if done that will be paid extra) Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.
148In all type of soils
149600 mm dia 12 mm thick casing pipe
1501000 mm dia 14 mm thick casing pipe
1511400 mm dia 20mm thick casing pipe
1521600 mm dia 22 mm thick casing pipe
1531800 mm dia 22 mm thick casing pipe
1542000 mm dia 22 mm thick casing pipe
155In Rock
156600 mm dia 12 mm thick casing pipe
1571000 mm dia 14 mm thick casing pipe
1581400 mm dia 20mm thick casing pipe
1591600 mm dia 22 mm thick casing pipe
1601800 mm dia 22 mm thick casing pipe
1612000 mm dia 22 mm thick casing pipe
162Providing, laying and jointing RCC NP4 jacking pipe (with steel pushing collar) with suitable leak proof joints (with using `12mm MDF sheets etc.) with compliance for maintaining slope as per design by trenchless method adopting Micro tunnelling method or any suitable mechanical technology below ground at all depth under running traffic condition including carrying out survey work at the job site for determining underground cable trenches like telephone, power cable, water & sanitary lines and resistivity tests for finding the soil strata using necessary equipment’s for completion of work, mobilizing of machineries and specialized crew at the job site, etc. complete in all respects, including excavation of drive pit and exit pit (upto 3 metre depth) with proper protection at the three sides, providing and casting of MS cutting edges for front shield and constructing thrust bed at designed level as directed by the Engineer, necessary de-watering and providing concrete foundations at the base of the Drive pit, crane for handling of pipes, and any other machinery, tool & tackles required, construction of temporary works as per requirement complete in all respect (all depths) with all lead and lifts, as per specification and the direction of the Engineer. Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.
163500 mm dia RCC pipe
164Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
165Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.
166Bituminous courses
167Granular courses
168Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work.
169Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work.
170M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
171Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
172Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including gettingout the excavated soil anddisposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available :
173Ordinary rock
174Hard rock(blasting prohibited) useful material 30%
175Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
176M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size).
177Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. Providing M-25 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix
178Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.Providing M-25 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix
179Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :
180Columns, pillars, posts and struts etc.
181Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc.
182Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.
183Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
184With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
185Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :
186Two or more coats on new work
187GSB Providing, laying, spreading and compacting of granular sub-base by providing close graded material (Table 400-1), spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion.
188For Grading II Material
189WBM Grading 1 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; handpacking, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up the interstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete.
190Crusher broken - Grade-III (53-22.4mm)
191Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.
192Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as Providing and laying open graded premix carpet 20mm thick (compacted), on prepared surface in a single course as wearing course, composed of specified graded crushed stone aggregate as per Table 500-23, premixed with bituminous binder @ 14.60 kg/ 10sqm (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required), including loading of material with F.E. loader, hot mixing of stone aggregate and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control to the required level and grade, compacting smooth wheeled roller 8-10 tonne capacity and finishing to required level to achieve the desired density as per clause 511 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding cost of tack coat/ seal coat.
193With Bitumen VG-grade 30
194Carriage of Materials by mechanical transport including loading,unloading and stacking ::
195Building Rubbish Stone metal (Grit and ballast etc.) up to 1 KM
196Surg Protuction
197Provision for surg protuction as per detail estimate
198Provision for Cathodic protuction as per detail estimate
199Construction of RCC (Flat slab type) Rectangular partially underground Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase in side and out side. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.
200d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab.j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m)Construction of inlet chamber, and valve chambers n) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
20122500Kl(Kishangarh bas)
20237000 KL ( Kot)
20339000 KL ( Jugawar)
204Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
205200 mm
206350 mm
207Providing, lowering, laying, aligning, fixing in positionand jointing at all level/ depths DI standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet andjointingasperIS:9523-2000 or as amended up to date,suchastees,bends, tapers,caps etc. within trenchesin DI pipe line completeincluding all material,labour, taxes, testingand commissioningalong with pipe line as per technical specifications anddirection of Engineer-in-charge (excluding earth work).
208All End Flanged
209Up to 300 mm Diameter
210Above 300mm and up to 600 mm diameter
211Above 600 mm diameter
212Up to 300 mm Diameter
213Above 300mm and up to 600 mm diameter
214Above 600 mm diameter
215Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge.
216MS pipespecialsup to600mmdia (withminimum5mmthickness sheet)
217MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet)
218SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work.
219EFM 200 mm
220EFM 400 mm
221Providing, Installation, Testing and Commissioning of Ultrasonic Flow Meter Insertion Type: Principle: Time of Flight / Type: Insertion / Protection : IP68 / Power Supply: 230 V AC / Output : 4-20 mA with HART / Accuracy: 2 - 3%
2221000 -4000 mm
223Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoorand outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm. Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx.
224Type VII ( 692.72 Sqm)
225Construction of Pump house of RCC framed structure Pump and panel room structure over RCC sump for Instalation of VT pumps as perGA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoorand outdoor lighting and fans, rain water drainage, sanitary, plumbing, / EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm.( Sump Size 35X6.0 Mtr and depth 6.0 Mtr. including Loading / unloading/Maintanace Bay 10X 3 Mtr, scada / office room 10 X4.0 mtr, Electrical panel platformsize 35 X 4.0 Mtr.
226As per Detail Estimatebased on BSR PWD 2022
227Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.
228PH Kishangarh Bas IPS+CPS
229PH Jugrawar IPS+CPS
230IPS Kot (Balancing Reservoir)
231Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.
232Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed:All kinds of soil
233Horticulture Work
234Supply of dry manure including loading unloading,transportation & stacking at site
235Farm yard manure(organic)
236Goat dungmanure.
237Vermi compost
238Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. Good soil of Earth.
239Supply of different varities of tree/shrubs/climbers according to height and age of the plant at side including loading/unloading & transportation etc.complete
240Different flowering plants 900mm to1500mm
241Different varieties of shrubs 600mm to 900 mm
242Different varieties of climbers 900mm to 1500 mm
243Spreading of manure , good earth in required thickness (cost of manure and good earth to be separately )
244Uprooting weeds from the lawn plots and trenched area after 10 to 15 days of its flooding with including disposal of uprooted vegetation
245Laying of lawns including ploughing leveling breaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost
246in rows 7.5 cm apart in either direction
247Supply & Planting of shady plants ( Neem. Peepal, Goolar, Jamun, Imli or other specified) along road side including the following activities:-(i) Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. (ii) Supply of plant at site of two years of age & height more than 1.50 Mtr. (iii) Supply of dry manure(Farm yard manure organic) (iv) Supply of Insecticides. (v) Digging of pits size 60x60x60 cms. Including removal of stones. Manuring application of insecticides & watering at least 1.5 Liter per plant after planting (vi) Half brick Circular tree guard in second class bricks, internal dia 1.25 meter and height 1.20 meter above ground and 0.20 meter above ground and 0.20 meterr below ground. Bottom two courses laid dry and top three couses in cement mortar 1:6( 1 Cement : 6 Sand) and the intermediate courseses being in dry honey comb masonry. As per design complete.(vii) Watering to plants (viii) Maintance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc & application of insecticiedes etc. & security. If the plant die during maintence contractor has to rplace same heingh plant at his own cost.
248Provision for Construction of Half Set Chokidar Hut
249Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. (For watering in plants and lowns)
250HDPE PE-100PN-6
25175 mm dia
252P & F G.I. Pipeswith G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :-( External Work ) Medium Duty Pipes
25325 mm dia nominal bore Class-B
254P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :
255Gun-metal 25mm nominal bore.
256Gun-metal 50 mm nominal bore.
257Making connection of G.I. distribution branch with G.I. main including all fitting.
258Upto 25mm dia
259Surface Drainage Work
260Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
261PCC work - M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size).
262M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 40mm nominal size).
263Brick work with F.P.S. bricks of class designation 75 infoundation and plinth in:1:6 C. Mortar
264Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20 mm th
265Providing and fixing of reinforced Ferro-Cement drain covers designed for \"A\" class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc
266Standard Size 600x800mm (75mm thick) for span 300 to 450mm
267Construction of RCC platform for transfarmer near Pump house as per detail specification and GAD, Size 3.00 mtr. X 3.00 mtr. outer 1) Earth work 0.60 width and 0.60 mtr. Deep for 4 nos wall, 2) PCC inM-10 with 20 mm stone aggrigate, 3) Raft for wall- 0.45 mtr. width - 0.15 mtr. thick. 4) 0.15 Mtr. thick RCC wallupto 1.00 mtr. above from GL. 5) earth filling with compaction in side. 6) 0.15 mtr. thick PCCM-10 under floor and7) 0.15 mtr. thick RCC M-20 flooring complet as per direction of EIC.
268Supply, Testing & Commissioning of Vertical Turbine pump motor set of specified duty parameters & guaranteed efficiency of following MOC with specified capacity horizontal foot mounted TEFC squirrel cage induction motor, working on three phase AC supply with 50 Hz ± 3%, 3.3 KV ± 10%, rated speed 1000 RPM along with column and bowl assembly, discharge head, base channel/RSJ etc. complete as per relevant IS. M.O.C.: Impeller & Sealing Rings:CF8M, Bowl & Suction Bell: CI FG 260 IS: 210 with 2% Ni , Shaft with coupling: SS 410, Column Pipe: M.S. ERW, Mechanical Seal (above 30 kW), Base Plate: MS, Line Bearing: Thordon type, Suction Strainer: S.S.
269from WTP to Kot 900 KW - 3.3 KV/TEFC, Discharge -619 LPS, Head- 116Mtr. Column-7 Mtr
270Supply, Testing & Commissioning of Horizontal Split casing centrifugal pump motor set of specified duty parameters & guaranteed efficiency of following MOC with specified capacity, horizontal foot mounted TEFC squirrel cage induction motor, working on three phase AC supply with 50 Hz ± 3%, 3.3 K V ± 10%, rated speed 1450 RPM along with fabricated MS base frame, coupling, coupling guard, foundation bolts etc. as per relevant IS. M.O.C.: Impeller & Wearing Rings: CF8M, Casing: Cast Steel WCB , Shaft: SS 410, Shaft Sleeve: SS 410, Mechanical Seal (above 30 kW), Base Frame: MS.
271275 KW Discharge 357 LPS , head 45 mtr.(IPS Kishangarh Bas to Bhiwadi Line)
272850 KW Discharge 619 LPS , head 93 mtr.(IPS Kotra to Jugarwad Line)
273850 KW Discharge 407 LPS , head 142 mtr.(IPS Jugarwad to Kishangarhbas)
274Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \"O \"ring seal Nut- Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
275Class PN 1.6
276500 mm dia
277600 mm dia
278Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and direction of Engineer In-Charge.
279500 mm dia.
280600 mm dia.
281700 mm dia.
282800 mm dia.
283Electromagnetic Flow Meter : Liner: Polyurethane or Hard Rubber /Electrode MOC: SS316L or CS /Housing : Die Cast Aluminium orCS / Power Supply: 90-230 V AC / Output: 4-20mA with HART /Sensor Cable : 10 mt / Flow Tube or Sensor housing protectionIP68 / Process Flange : SS316 / Display : 3 1/2 LCD Display /Cable Connection : 1/2\"NPT /Accuracy : 0.5%
284900 mm dia.
285Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum
286Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD.
2872.2 KW (3.0 HP)
288Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
28950 mm
290Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase upto 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\" and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.
291Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc.
2923 core 4.0 Sq.mm
293Supply, receving, storing,inspection, handling , assembilng ,installing in correct alligned position, effecting proper connections,testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer(+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 450/400 C first fill oil, having permissible totak less values not exceeding 7.5% of the maximum total loss values for 11KVasperenergyefficiencylevel-2atbasicInsulationlevel conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014.
2941000 KVA
295315 KVA
29610000 KVA (33KV / 3.3 KV) AS PER IS 2026
2978000 KVA (33KV / 3.3 KV) AS PER IS 2026
2981600KVA (33KV / 3.3 KV) AS PER IS 2026
299O.L.T.C. With R.T.C.C. & AVR (FOR 33KV TRANSFORMERS)
300Supply,Installation,testingandcommissioningof33KVDouble PolestructurewithAirBreakSwitchhavingfollowing specifications.a) DP : Double Pole structure made of two nos. 11 m long PCC poles (400Kg) & 7 nos. MS Channel size 100x50x6mm complete with earthing of the structure as perREC standardsin all respect with nuts, springs washers, clamps as required.b) GO: Off load type gang operated three pole Horizontal type switch suitable for 33KV, 800A, 3phase central post rotating double break isolator completewithMSHardware,coppermoving&fixedcontacts, assembly of 9 Nos. Post Insulators, GI pipe of suitable length for operation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.e)LA:3piecenonlinearresistortypelightening arrestorofapprovedmakesuitablefor3wire,33KVohlinewith rated voltage 30KV rms & nominal discharge current rating of 10 KA & complete with galvanized clamping arrangement, GI bolts, nuts, washers etc. as required.e)Jumpers:3 Nos. ACSR Dog Conductor mountedonpintypeinsulatorsasrequired.TheGOshallbe operated by hand operated liver properly earthed with provision for locking mounted at 3’. Complete as per technical specifications and /or as directed by engineer.
301Supply, Installation, Testing and Commissiong of indoor type floor mountedmetalclad,33KVIncomerVCBpanelupto630A equipped with following switchgears and accessoriesdesigned & tested as per latest standard i.e. IEC 62271-200, suitable for STC 31.5KA/3andIACA-FLRfor31.5kA/1sec.MakeofHTPanel, Vaccum Interrupter and VCB should be of same make.
30233 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 36 KV on incomer, Ammeter,analogtype,selectorswitchesforammeters, MicroprocessorbasednumericalrelaywithO/L,E/FandS/C protection, Set of dual core dual ratio 3CTs of suitable ration with sec 1 of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter.
303Supply, Installation, Testing and Commissiong of indoor type floor mountedmetalclad,33KVBusCouplerVCBpanelupto630A equipped with following switchgears and accessories. STC 31.5KA/3 and Internal Arc test A-FLR for full short circuit current for 1 sec. duration. Make of HT Panel,Vaccum Intrrupter and VCB should be of same Make. Bus Coupler 1 No 630 Amp. VCB
304Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 33 KV Incomer cum outgoing VCB panel up to 630Aequippedwithfollowingswitchgearsandaccessoriesdesigned&testedasperlateststandardi.e.IEC62271-200, suitable for STC 31.5KA/3 and IAC A-FLR for 31.5kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make.
30533 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 36 KV , Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core dual ratio 3CTs of suitable ration with sec 1 of 15 VA burden and accuracyClass–0.5formeteringandclass5P10forprotection, Multifunction Meter
306SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries,FCBC(Floatcumboostcharger)suitablefor415V+/-10%,50Hz,1-ǿ / 3 -ǿ Input & 24/ 48 /110 V DC Output Natural Cooled,freestandinginSheetSteelenclosure,SCRcontrolled, regulation+/-1%,Efficiency>75%onFLAC/DCInstruments, SelectorSwitch,BuiltinDCDistributionBoard(6NoMCB), indication , control as required. All as per pre approved by Engineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR .
307Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 33 K.V.(E) confirming IS :7098 P - 2withH4-GradeelectrolyticaluminiumconductorconfirmingtoIS:8130 class-2ofpurity>99.6%,InsulationScreening:Extruded SemiconductingCompoundfollowedbyhelicallywrappedCopper Tape,round/flatstriparmouringofcables,Inner/outersheath PVCtypeST-2confirmingtoIS:5831inexistingRCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have it\"s own in houseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
3083 core 240.0 Sq.mm
309Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kitsuitable for11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test reportshouldbeasperIS13573:2011whichcoveredallsequence fortable2forterminationkitandtable3forstreightthroughjoint inclusive thermal & dynamic short circuittest, humiditytest, soil fog test.CrosslinkingshallbedoneoutsidefactorywithE-beam/ peroxidetechnology.ExtrusionprocessshallbeinhouseOEM withinsamevicinity.includingtestingetc.asrequiredoffollowing sizes. All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR .
3103 core 240/300/400 Sq.mm
3113 core 240/300/400 Sq.mm
3123 core 240/300 Sq.mm
3134 core 240/300 Sq.mm
314PlateEarthlingasperIS:3043withcopperEarthplateofsize 600mmx600mmx3.0mmbyembodying3to4mtr.Belowthe ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C.finishedchambercoveredwithhingedtypewithlocking arrangementC.I.Cover,C.IFrameofsize300mmx300mm completewithalternatelayersofsaltandcoke/charcoal,testingof earth resistance as required.
315Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia.‘B’classG.I.Pipeincludingallaccessorieslikenut,bolts, reducer,nipple,wiremeshedfunnel,andC.C.finishedchamber coveredwithhingedtypewithlockingarrangementC.I.Cover,C.I. Frame of size 300mm x 300 mm and embodying the pipe complete withalternatelayerssaltandcoke/charcoal,testingofearth resistance as required.
316S & Laying following size ‘B’ Class G.I.Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required.
31750 mm dia.
318Supply&Layingfollowingsizeearthstripinhorizontalorvertical runinsurfacebymeansofEarthstripDMCInsulatorincluding riveting/soldering/welding,Jointingshallbedonebyoverlapping andwith2setofBrass(forCustrip)/GI(forGIStrip)nutbolt& springwasherspacedat50cmmakingconnectionetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
31950mm x 6mm copper strip
32025mm x 6mm G.I. ( Hot Dipped) Strip
32132mm x6mm G.I. ( Hot Dipped) Strip
32250mm x 6mm G.I. ( Hot Dipped) Strip
323Supply,Fabricating&installingfollowingsizesofperforatedHot dippedGalvanizedironcabletray(Galvanizedthicknessnotless then 50 microns) with perforation not more then 17.5% in convenient sectionincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended fromtheceilingwithGIsuspendersincludingGIbolts&nuts, fastners,supportsetc.asrequired.Allasperpreapprovedby Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
324100mm x 50mm x 1.6mm
325150mm x 50mm x 1.6mm
326300mm x 50mm x 1.6mm
327SupplyinganddrawingPVCinsulated&sheathedsolid/stranded copperconductormulticorecontrolcableISImarked(IS:1554)of 1.1kVgradeofapprovedmakeasperchapterE11,inexisting surfaceorrecessedconduit/casingcappingincludingmaking connections etc. as required.
3284 core, 1.5 sq. mm. armoured
3298 core, 1.5 sq. mm. armoured
3308 core, 2.5 sq. mm. armoured
33119 core, 2.5 sq. mm. armoured
332Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - Iof1.1KVwithH4-Gradeelectrolyticaluminiumconductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC /Hume/Stoneware/PVCpipe/openduct/cabletrench/Cable tray(withcabletie)includingtestingetc.asrequiredoffollowing size.OEMmusthaveit\"sowninhouseNABLaccrediated LaboratoryfortestingprocedureasperIS:10810.Foradditional technicalparametersofproduct/workreferAnnexure\"A\"attached with this BSR
333400 SQMM,3.5 CORE
334300 SQMM,3.5 CORE
335120 SQMM, 3 CORE
33635 SQMM, 3 CORE
33716 SQMM, 3 CORE
3384.0 SQMM, 3 CORE
339SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/freestandingfloormounteddustandverminproof compartmentalisedcubicalpanelasspecificationsandOther parameters requiredas per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:-(a)ThicknessofCRCAsheetshallbe2.0mm,cablealley compartmentshavingconcealedhingedtypedoorswithkeytype lock with / withoutdetachable extension type structure. Removable 3mm.thicksheetsteelglandplateswithappropriatesizeof knockouts for cables shall be provided(b)completepanelshallundergoaprocessofdegreasing,Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panelhavingPEfoam/Neoprenerubbergasketofnotlessthan 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) nterconnectionbetweenbusbarandswitchgears/cableshall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried outwith1.5Sq.mm,Earthwirewith2.5Sq.mmandCTwith2.5 sq.mmflexiblecopperwireonly.Alljoints/interconnectionsof copper bus bar shall be dully tinned . Clearance between main bus barandrisers/metalpartsshallbeatleast10mmadditionalto widthofbusbarBusbarisinsulatedbyHeatShrinkablesleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (CostofBusbar/FlexiblewireforInterconnectionbetweenMain connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)FloormountedpanelshallbemountedonBaseframeofISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute)shallbemeasuredbetweenphases,betweenphaseand neutralandbetweenphaseandearth.bothbeforeandafterhigh voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to befabricatedonlyfromCPRIapprovedfabricatoronly(CPRITest certificates to be submitted)All as per preapproved byEngineerin-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .busbar and Switchgearis to be Paid Extra ) (d)WiringbetweencomponentswithinswitchgearandIncoming/ outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted.Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads,studswithtwonutsandidentificationstripsandshallhave adequate continuous current rating. For tap-offs, adjacent terminals withshortingstripsshallbeused.10%Spareterminalblocksshall be provided. Wire identification on marking strip shall correspond to thedesignationofthewiringdiagrams.Allwireterminalsonthe equipmentshallalsobemarkedwithdesignationcorrespondingto those of the wiring diagram. (e)Allwiringshallbeenclosedinplasticchannelsandneatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee
340SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/ Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwithstandardshortcircuitwithstandcapacity,hightensilenuts and bolts spring washers in existing panel including bending , cutting inrequiredshapeandsizeandcolourcodingwithheatshrinkable PVCsleeves.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
341Electrolytic grade Aluminium bus bar 6010 grade
342Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/Frequencymeter/KWHmeter/MultiFunctionMeter/ Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96mmincludingmakingconnectionbyPVCinsulatedcopper conductorwithPVCsleeves/channeletc.asrequired.Allasper preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
343Three phase with universal Auxiliary supply + AMP + HZ + PF + KW +KVA+KVAR+KVARH+KWH+DUALENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485
344ThreephaseAMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS
345Providing&FixingofBISapprovedCurrentTransformerasper PWD specification for electrical Works ,ISI marked as perIS 2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCT shallbebroughtoutsuitabletoaterminalblockwhichshallbe easieraccessiblefortestingandterminalconnection,withall necessarysupportinexistingpanelincludingconnectionetc.as requiredCurrenttransformerRingTypeTapeWound/ResinCast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm (minimum),includingallnecessarysupportinexistingpanel includingconnectionetc.asrequired.Allasperpreapprovedby Engineerin-charge.AllasperpreapprovedbyEngineerin-charge. Foradditionaltechnicalparametersofproducts/work,refer Annexure \"A\" attached with this BSR .
346C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA
347C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA
348Providing & Fixing ofCam operated rotary (Auto/manual) switches onexistingpanelwith2wayandoffpositionusinghighgrade engineeringmaterialtointernationalstandardswithcamassemblyinsulationofglassfilledpolyamidewithhightrackingindex.For reliable and stable electrical and mechanical endurance double butt contactswithsilverbi-metaloncoppershouldprovidedcontact assemblyis of operating temp range-25 degree C to55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanicallyminimum50000operations@300cycles/hourand electrically10,000operationsat100%rateddutyfor100cycles/ hourincludingmakingconnectionetc.asrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
34910 AMP
35016AMP
351Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947withintegralcircuit,IP65abovepanel&IP20terminal block,Approx.bodydiaforpanelnot lessthen20mm,lengthmin. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
352Red/yellow/Blue
353Red/Gree/ white Colour
354Red/Gree/ white Colour
355Red/Green
356Providing&FixingofflushheadpushbuttonactuatorsIEC60947withintegralcircuit,IP65abovepanel&IP20terminalblock, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze forLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,includingconnectionetc.asrequired.AllasperpreapprovedbyEngineerin-charge.Foradditional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR
357Non luminous type
358Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 withonesideantiskidabberationmarksandpastingthe matwithsyntheticrubberadhesiveasrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
35933 KV,class C 3 mm thick with proof voltage 36 KV AC (rms) for3 min. and Break Down Voltage 65 KV AC (rms)
360SITCof3/4polecurrentlimitingMouldedcasecircuitbreaker (MCCB)madeofflameretardent&heatresistantmaterialhaving followingcurrentrating,shortcircuitbreakingcapacityat440/415 V,50Hz;O/L&S/Csettings,conformingtoIS/IEC60947P-2 :2003withfrontfaceandcentralisedadjustable,tripfree mechanisum,truecontactpositionindicator,lineload interchangeability, designed for both horizontal&vertical mounting withoutanyadverseeffectonelectricalperformance,suitablefor operationupto55degreeandwithoutderatingupto40degree,pollution degree 3, having positive isolation capability, push(test) totrip,triptimelessthen10msunders/ccondition,Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock&rotaryhandle,includingmakingconnectionsetc.as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
361630 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
362Extended Rotary Handle
363Mechanical Interlocking kit
364Auxiliary + Trip alarm contact
365Spreaders for 630A, 4 Pole MCCB
366SITCofDrawouttype3/4poledoorinterlockAirCircuitBreaker (ACB)asconformingtoIS/IEC60947P-2:2003inexistingLT panel suitable for LT installation 440 V, 50 Hz and having adjustable overloadshort-circuit,Instantaneous,earthfault(LSIG)withseparateLEDindicationforeachtypeoffaultshallconfirmtoEMI/ EMC test, LCD/LED display, last 10 trip history, provisionofZSI, Communication, Power metering module, Thermal memory , trip free mechanisum,suitableforambient50degreeandutilization catagaryB.Inbuiltelectrical&mechanicalantipumpingfeature, 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw(1sec),Uimp-12KV,breaktimenotmorethen25ms. Provisionforelectrical&mechanicalinterlockbetweenACBs, Min.electricaloperation10000upto2000Aratingand5,000for 2500Ato4000A.includingmakingconnections,testingetc.as required. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineerin-charge.Foradditionaltechnicalparametersofproduct/ work refer Annexure \"A\" attached with this BSR
3671600 A Rating ,50 kA
368SupplyandfixingoffollowingaccessoriesforAircircuitbreaker (ACB)compatiblewithMAinACBOEMasperPWDspecification forelectricalWorks,conformingtoIS/IEC60947P-2:2003 includingmakingconnectionetccompleteinallrespect.OEMshall havesubmitNABL/CPRI/ERDAaccrediatedlabtypetest certificatebeforeexecution.AllasperpreapprovedbyEngineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR .
369Shunt Trip Release
370Under voltage Release
371Microswitch for Indication
372Operation Counter
373Door Interlock
374Auxiliary Contact 4 NO + 4 NC
375Breaker Control Switch (TNC)
376Providing& Fixing of IP54 microprocessor based 3CT’s for all 3 phasesensingcompensationpowerfactorcorrectionrelaySize 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having3CTsensing,sensitivityupto50milliamp secondarycurrent,selfanalysingautoc/ksettingaccordingto targeted power factor setting, the relay shall have digit displayunit fordisplayofrealpowerfactor,targetedpowerfactor,lag/lead capacitorswitchingstatus,alarmoutputforundercurrent,over current, insufficient compensation, communication interface with RS 485,indication of switching onunits, auto/manual status, and shall haveoverloadprotection,novoltrelease,havingmultiparameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay includingmakingcoonectionwith1.5Sq.mmcopperwireetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
37712 to 14 stage
378Providing&FixingofselfhealingIP20MPPtypeshuntcapacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1&2inexistingpanelorparallelwithloadterminals,thecapacitor shallbefittedwithdischargeresistors,pressuresensitive disconnector(PSD)andshallhavedissipationfactorlessthan 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min overcurrentcapacity1.8timesratedcurrent&peakinrushcurrent min.300timesofratedcurrent,llifeexpectancygreaterthan 100000hrs(tempclass-25D)in440V/480VCapacitorandfor 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
379HeavydutyThreephase440V,50Hzcylindricaltypecapacitor (Bank)
380Providing&Fixingof440Volt3polecapacitor(AC6B)duty contactor with 3 no. early make and post break auxiliary contacts in serieswithquickdischargedampingresistors/reactorstolimitthe inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1:2000,insulationvoltage1000V,impulsewithstand voltage8KV,Dinrailmountingtypeincludingmakingconnections, testingetc.asrequired.suitableforfollowingcapacitycapacitor bank.All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR .
381up to 6 KVAR
38210 KVAR
38315 KVAR
38425 KVAR
38550 KVAR
386Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kAbreakingcapacity(B/C/Dtrippingcharacteristicaspertypeof loadandsiterequirement)4KVimpulsewithstandvoltage,ISI markedIS8828(1996)/conformingtoIEC60898-12002,IEC 60947-2,lowwattlosses,tripfreemechanisum,energylimitingofclass3asperIEC,minimumphaseterminationcapacityof 35sq.mm. , conductor line load reversibility , IP 20 contact protection andfittedinexistingdistributionboard/sheets,minimumelectrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A&aboveratingincludingmakingconnections,testingetc.as required. OEM shall have submitNABL / CPRI / ERDA accrediated labtypetestreports&AllasperpreapprovedbyEngineerin-charge.Foradditionaltechnicalparametersofproduct/workrefer Annexure \"A\" attached with this BSR
387Triple pole MCB(With B/C curve trippingCharacteristics), 6 A to 32 A rating
38850/63 A rating
389125A rating
390Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating
391Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating
392SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus.
39390KW
39430KW
395S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ontrolMCBwithpanelwithallaccessorieswithfollowing rating : 11KW
396S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ontrolMCBwithpanelwithallaccessorieswithfollowing rating : 15KW
397SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried.
398SupplyanderectionofGalvanizedIronpolewith galvanizingdone insingledipping(AveragecoatingthicknessMinimum65Microns) continuouslytaperedpoleshavingOctagonal/Circularcross-sectionsdesignedtowithstandthemaximumwindspeedasperIS 875,Thepoleshaftshallbemadefromsheetsteel(HTSteel ConformingtogradeS355JO)andconfirmingtoBSEN10025and shall be continuously tapered with single longitudinal welding. There shallnotbeanycircumferentialwelding.Theweldingofpoleshaft shallbedonebySubmergedArcWelding(SAW)process.pole shaftsshallbeprovidedwiththerigidflangeplateofsuitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to thepoleshaftattwolocationsi.e.frominsideandoutside.The octagonalPolesshallhavelockabledoorofapproximate500mm length at the elevation of 500 mmfrom the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) insidethepoleatdooropeningforcableconnectionoffollowing lengthanddimensionaspertableP-01withbaseplateand foundationboltontheExistingcementconcretefoundation.Allas perpreapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
3997 Mtr., Poles with Octagonal Cross Section
400SupplyandFixingofPoleOEMfabricatedhotdippedgalvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR .
401Single arm overhang
402ProvidingandLayingRCCFoundationforOctagonal/Conical StreetLight poles, High mast Poles as per Drawingattach at TableP-4withFollowingProcedure&Allasperpreapprovedby Engineer in-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . A)ExcavationofPitforFoundationSizeuptorequireddepthfrom Ground levelB)DressingofPitandDrystonepitching200mmthickincluding supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D)ReinforcementforR.C.C.workwithTMTbarsincluding straightening,cutting,bending,placinginpositionandbindingall complete. E)Centringandshutteringincludingstrutting,proppingetc.and removal of form work for Footing and Pedestal F)Providing&Fixingof2no.RequiredSizePLBHDPEPipe& Foundation Bolt with template as per OEM Recommendations. G) Providing and LayingReinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.
403Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.
404Providing&FixingofIK08,IP66protectedLEDStreetLight Luminaireonexistingbracket/pole.Fixturemadeofpowdercoated singlepiecepressurediecastaluminummaterialwithheat dissipationfinsonhousingwithUVstabilizedPC(UVstablization reportsubmittedforUVcover)/ToughenedGlasscoverand secondarylensoneachLED&shouldbeSMDtypeof3to5watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with HighvoltageCutoff@>=300VACandAutoresettingSafety, Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. TheluminaireshallbeBIScertifiedandTrademarkcertified.Life ExpectancyEqualormorethan50000burninghrswithMinimum 70%lumenmaintened,CRI>70andCCT5700K+355K.Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside drivercompartment.drivershouldbePhasetophaseprotectionof 440Vfor4Hrs.ManufacturesWordMark/Name Engraved/Embossingondiecasthousingtoallow traceability/authenticity.FixtureshallbeASPERIS10322 Complianced.OEMMusthaveitsowninhouseNABLlabsetupfor alltestingfacilitiesforLEDfixtures.(LM79/LM80)Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
405LED Street Light fixture with Minimum lumen output 8700 lm
406Providing&FixingofIP-65protectedimpactresistant polycarbonate/Polystereneenclosureswithknockoutforcable entry/outincludingfixingwithnut,bolt,fatneretcasrequired complete in all respect of following sizes.All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
407180 x 180 x 91 mm
408Providing&FixingofStreetlightbracketmadeoutfromfollowing size of \" B \" class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. asrequired.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
40932 mm Dia.
410Providing&FixingofIK08IP-66protectedhighpowerLEDflood lightsystemwithsinglepiecePressurediecastaluminiumhousing, toughenedglassdiffuserwithsuitablelensesonLEDtoachieve variousbeamangles,ofhighpowerLEDof3to5watteach. Integrated potted driver as a unique BIS R numberhaving efficiency more than 85 % and in compliance to BIS certified and Trade markcertificate.TheSystemlevelLuminaireefficacy>=125lm/wt.LED driverInputVoltageAC120to270VACwithHighvoltageCutoff @>=300VACandAutoresettingSafety.PowerFactor>0.95, THD(I)<10%,drivercurrent<=750mA.drivershouldbePhaseto phaseprotectionof440Vfor4Hrs.ElectricalConnector,Surge ProtectionMin>=4KVinternaland10KVexternalbutinsidedriver compartment, System life of 50000 Burning hours with 70% of Initial Lumensmaintained,CRI>70andCCT5700K±355K.ManufacturesWordMark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shallbeIS10322Complianced.OEMMusthaveitsowninhouse NABLlabsetupforalltestingfacilitiesforLEDfixtures.(LM79/LM80)Certificate/reportwithliablewarrantyof product/accessoriesfromOEMshallbesubmitted.Allasperpre approvedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
411High Power LED Flood Light Minimum lumen output 10000 lm
412Providing and fixing in position lightening arrester set complete with 600mmx600mmx6mmthickG.I. earthingplate embeddedbelow groundinearthlingpitat3.5metrdepth,G.I.stripofsize 25mmx5mm thick from earthing plate to top of Over head tank, G.I. FinialmadeofGIbar25mmdiaand2mlongfixedontopofOH tankandconnectedtoGIstrip.Theearthlingsetshallcomplyof IS:3043 complete in all respect as per specification and the direction of the Engineer.
413Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Washers, Electrical Taps, HT Tap, Danger Plates, 4.5 Kg. CO2 type portable fire extinguisher for Panel Room , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per site requirements.
41433KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,coversect.
415From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W) x400 (H) x 600 (D)
416Supplyof indoortype floor mounted metal clad, incoming 3.3 KV VCB panel equipped with following switchgears and accessories. 1. 3.3 KV, analog/digital type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 7 KV on incomer 2. Ammeter, analog type, selector switches for ammeters. 3. Microprocessor based numerical relay with O/L, E/F and S/C protection. 4. Set of dual core dual ratio 3CTs of suitable ratio with sec of 1 A of 15 VA burden and accuracy Class –0.5 for metering and class 5P10 for protection 5. Multifunction Meter , Incoming from 630 to 1250 Amp. VCB
417Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 3.3 KV Bus Coupler VCB panel equipped with following switchgears and accessories. Bus Coupler from 630 to 1250 Amp. VCB
4181. 3.3 KV / 110 Volts PT Class0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-3.3 KV), analog/digital type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 3.3 KV on 2. Ammeter analog type, selector switches for ammeters. 3. Microprocessor based numerical relay with O/L, E/F and S/C protection. 4. Set of dual core dual ratio 3CTs of suitable ration with sec 1 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection 5. Multifunction Meter outgoing, Outgoing from 630 A to 1250 A VCB
4193.3 KV HT FMCA Digital Soft Starter Panel with reactorfor HT VT Motor ,--Inddor Type, Metal enclosed compartmentalized, Short Circuit withstand & duration (Sec.) - 5KA for 1Sec, Rated 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X, Control & Protection Sypply - 110VDC, 10KV for 1min power frequency, 2 Pole Vacuum Contactor 400A, Bus Bar - Copper, FMCA Coils type - Air Core as per IEC 60076-6,Insulation - Class F, Temp. rise limited to class B. Coil material - Copper conductor is wound on Fiberglass bobbin, No of Tappings - 5 nos., Single Power cable Based.
4203.3 KV HT FMCA Digital Soft Starter Panel with reactorfor HT VT Motor ,--Inddor Type, Metal enclosed compartmentalized, Short Circuit withstand & duration (Sec.) - 5KA for 1Sec, Rated 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X, Control & Protection Sypply - 110VDC, 10KV for 1min power frequency, 2 Pole Vacuum Contactor 400A, Bus Bar - Copper, FMCA Coils type - Air Core as per IEC 60076-6,Insulation - Class F, Temp. rise limited to class B. Coil material - Copper conductor is wound on Fiberglass bobbin, No of Tappings - 5 nos., Single Power cable Based.
4213.3 KV HT FMCA Digital Soft Starter Panel with reactorfor HT VT Motor ,--Inddor Type, Metal enclosed compartmentalized, Short Circuit withstand & duration (Sec.) - 5KA for 1Sec, Rated 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X, Control & Protection Sypply - 110VDC, 10KV for 1min power frequency, 2 Pole Vacuum Contactor 400A, Bus Bar - Copper, FMCA Coils type - Air Core as per IEC 60076-6,Insulation - Class F, Temp. rise limited to class B. Coil material - Copper conductor is wound on Fiberglass bobbin, No of Tappings - 5 nos., Single Power cable Based.
4223.3 KV-HT APFC Panel for HT Motor ,- 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized. (550KVAR)
4233.3 KV-HT APFC Panel for HT Motor ,- 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized. (450KVAR)
4243.3 KV-HT APFC Panel for HT Motor ,- 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized. (160KVAR)
4253.3 KV-HT APFC Panel for HT Motor ,- 4 KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized. (200KVAR)
426Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 3.3 K.V.(UE) confirming IS :7098 P - 2withH4-GradeelectrolyticaluminiumconductorconfirmingtoIS:8130 class-2ofpurity>99.6%,InsulationScreening:Extruded SemiconductingCompoundfollowedbyhelicallywrappedCopper Tape,round/flatstriparmouringofcables,Inner/outersheath PVCtypeST-2confirmingtoIS:5831inexistingRCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have it\"s own in houseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
4273 core 240 Sq.mm (3.3KV, XLPE, ARMORD, UE)
4283 core 240 Sq.mm (3.3KV, XLPE, ARMORD, UE)
4293.3 KV NGR Control Panel,3.81 Ohms with100 A, 10 Sec Capacitywithsupporting Structure for installation.Hence NGR of 3.81 Ohms is required with capacity of 1000 Amp 10 sec.Complete as per technical specifications and as directed by Engineer in charge.
430SITCofHT33KV,3Phase,50Hz,totallyenclosedmetalcladSF6 switchgearhavingrupturingcapacityupto630Amps,OutdoorNon ExtensibleFixedType(IP54),RMU(Ringmainunit)comprisingof manuallyoperatedLoadBreakSwitchandmanualchargingfixed-typeVacuumCircuitBreakerasperrequirement,insiderobotically welded stainless steel grade 304 (Non Ferrite Non Magnetic Grade) tankhavingofminimumthickness2mmwithIP67Degreeof ProtectionandenhancedBILof170kVpinternallytomanage voltagesurges.RMUshouldbeprovidedwithinternalbusbars,as wellasearthingbusbarsofelectrolyticgradecopper,padlock provisions&completewithallaccessories.TheRMUshallbetype testedforInternalarctestofAFLR25kA/1secfortankandcable chamber as per IEC62271-200. RMU shall have on-site-repair ability features such as site replaceable bushing/ coupling/ mechanism and gasrefillingatsite.Theearthingbusbarshallbeprovidedinside eachcablecompartmentforsolidearthingofcablesheilds.The outerhingedmaindoorshouldcoverentirefrontofswitchgear including cable doors for providing better ingress protection. The unit shallincludethefollowingwithallnecessarystandardfittingsas required at site.Load Break Switch module consisting of following accessories : 33kV,630AmpLoadBreakSwitchmoduleandintegratedearthing switch, both with full making capacity. ShortCircuitwithstandcapacity-25kA/3-sec,MakingCapacity– 62.5 kAp, Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 Nos,touch-proof screen separable termination kit (push on type) VCBBreakermoduleconsistingoffollowingaccessories:33kV, 630 Amp fixed-type Vacuum Circuit Breaker module for making and breakingoffaultcurrentalongwithdisconnector+EarthSwitchof full making capacity. Short time current breaking capacity - 25KA/ 3 sec, Making Capacity – 62.5kAp, Auxiliary contacts - 1NO + 1NC VCBoperatingsequencemustbeO-0.3Sec-CO-3Min-COand mechanical endurance confirms for minimum 10000 operations. touch-proof screen separable termination kit (push on type) Numericalbasedself-poweredOC+EFProtectionRelay,providing Over Current (min. setting 20%), Earth-Fault (min. setting : 10%) 03Nos50-100/1,2.5VAepoxyinsulated,RingCoreCTsfor protection(Acc.CL5P10),installedawayfrombushingstoprevent saturationofcore.(CTRatiomychangeaccordingtochangein Load) AllmodulesshouldhaveSuitablesitereplaceablecablebushings situatednotbeyond300mmfromcable-covertoalloweaseof access for installation/ testing/ replacement purposes. Cable covers with self-Interlocking mechanism between doors, earth switch, disconnector & VCB Capacitive voltage indication fixed type system (i) Capacitive voltage indication fixed type VPIS 28-45 kV (ii)OneNo.OperatingHandleforManualOperationandoneno. manometer (iii)SafetyInterlocksShallbeprovidedasperrelevantIEC/IS Standards and Manufacturer’s directions (iv) Above switchgear shall confirm to all relevant IEC/IS Standards. (v) Vacuum interrupter should be of same make as RMU (vi) Cable bushing should be replaceable at site. (vii)Minimum4moduleshouldaccommodateinonetanktoavoid multiple coupling at site.
431Non-ExtensibleType4wayRMUwith2no.VCB&2No.LoadBreak Switch
432Design,Manufacture,Supply,Installation, TestingandCommissioningofIndoortypePLC Panelofsizeapprox.800mmX500mmX 2000mm(LBH),Fabricatedoutofmin.2mm thickCRCAsheetcompletewithlatest configuration,necessaryprogrammingsoftware forPLC&SCADAandcomprisingofall accessories not limited to the following: DI 102No. DO 98No. AI 22No. AO 16No. MCB 16A DP 2No. MCB 6A DP6No. SMPS 100-240VAC/ 4.5A / 24 VDC 1No. Selector Switch (uto/Manual) & Local / Remote2No. Control Relays1Lot Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with1No.Electronic Hooter1No. Control Transformer 200VA1No. Emergency STOP Push Button1 No. Panel Cooling Fan & Filter2No. Panel Light with Door Switch, 7W1No. Control Indication Lamp for 24VDC, 220VAC3No.Push Button3No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc1Lot PanelHardware,lugs,terminations,ferruls, name plate Ect.1Lot UTILITY SOCKET 16A, 3 PIN2No. HMI Display 12 Inch, Colour1No. Isolators Dual Output, 24VDC1Lot
433Quad-bandGPRS/IOT/VPN/GSM/CLOUD 3G/4G/5G modemwithEthernetbridge/router/ serial server (RS232/485) interface.
434SITCofIntelligentManageableEthernetSwitchesproviding24x 10/100/1000FastEthernetports-and2dualpurposeuplink (provisionforCopper/FibreGigaconnectivity)withLANbased Software.TheLANbasedS/Wsupportsenhancedintegrated security,includingNetworkAdmissionControl(NAC),advanced qualityofservice(QoS),availabilityandscalablemanagementto enable new converged applications
435Providing,installation,testingandcommissioningofONLINEUPS SYSTEM,SinglePhase230V,50Hzwith2hourbackupSMF battery bank as per specification
4362 KVA
437ProvidingandlayingStranded/FlexibleAnnealedeBarecopper conductor,XLPE/PVCinsulatedsuitablylaiduptogetheroverall polystertapedAl(innersheatedGISteelwireMylar/Drainwire) alongwithATCdrainwire,round/steelarmouredoverallPVC sheathed (ST-1) overall screenedCore armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.
43824 CORE, 1.0 sq. mm.
4394 CORE, 1.0 sq. mm.
440ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. (2 Pair * 0.75SQMM)
441Providing,Installation,TestingandCommissioningofUltrasonic LevelTransmitter:Principle:TimeofFlight/SensorMOCPP/ PowerSupply:24VDC/Output:4-20mA/Display:Integral displayforprogrammingandDisplayReading/IP66/Accuracy ±1%
4420 - 8 Mtr.
443Providing,Installation,TestingandCommissioningofPressure Transmitter : Range:0-10Bar / Power Supply:24 V DC / Output: 4-20mAwithHART/Diaphragm:SS316L/ProcessConnection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67
444Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material ofsensorandotherwettedparts:SStype316,Housing:Diecast aluminum,Switchtype:Microswitch,Repeatability:±1%ofspan, Switch Contacts: 2 NO + 2 NC
445Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes,Probeinsulation:Teflon,Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum
446Rigid for lengths from 3 - 10 Mtr.
447Supply,Installation,TestingandComissioningofISOcertified companymadeAirCooledHiWallsplittypeAirconditionerswith lateststarratingsystemasperBEEamendeduptodatecomplete withIndoorunit(IDU),Outdoorunit(ODU),surface/concealed copperRefrigerantpipingwithinsulation(closedcellelastomeric nitrile rubber tubular pipe section)upto 3 Mtr (IDUto ODU), copper powercableupto3.5Mtr(IDUtoODU),R-32/R-410/R-407Green Refrigerant,wirelessRemotecontrol,suitableforworkingbetween 180-260Vwithlow&highvoltagecutoffand50hz,1phaseAC supplycapableofperformingcooling,dehumidification,air circulation of following capacitywith Scroll / rotarycompressor. Min 5 year OEM warranty both compressor and PCB. NABL accredeated asperIS/ISO/IEC17025standards/CPRI/ERDAlabtesting reportsasperIS1391(Part-2)2018withOEMcertificatemust submittedtoengineerin-charge.Allasperpreapprovedby Engineer in-charge.All asper pre approvedbyEngineerin-charge. Foradditionaltechnicalparametersofproducts/work,refer Annexure \"A\" attached with this BSR . Non InvertorType1.8/2.0TRwith3starratingofBEE(ISEERnot less then 3.5 )
448Supply, Installation, testing and commissioning of SCADA System at MasterControlCentrecompletewithPCserver,monitor, communication modules, printers, 2 Nos. of 60\"LED Display of latest resolution and configuration, 4 Nos of 32\"\" Operator console ( 1 No. of Engineering, 1 No. of operator console, 1 No. of Historical and 1 No. of Web Server) including control desk, chairs, storage racks etc., requiredhardware,softwarecompletewithallaccessoriesandin line with Technical Specification.
449Providing,installation,testingandcommissioningofONLINEUPS SYSTEM, 3 Phase 415 V, 50 Hzwith2 hour backup SMF battery bank as per specification
45010KVA
451LocalDataLogger-PCbasedDataAcquisitionSystemwithSAM WILicenseSoftwaresuitableforStoring,Logging,Reporting, PrintingdatafromaboveofferedAnalysers.PCwithspecifications as under: Intel Core i5 5th Generation Processor, 8 GB RAM, 1 TB HDD+250 GB SSD, CD/DVD Combo Drive, 32\"Monitor, Minimum 6 USBports(USB3.0/2.0),WINDOWS-7orhigherCompatiple Operating System, standard keyboard, mouse with pad and with A3 & A4 Color Laser printer.
452CentralDataLogger-PCbasedDataAcquisitionSystemwithXR Premium License Software suitable for Storing, Logging, Reporting, Printingdata,Validationandcommunicatingwithaboveoffered LocalDAS.PCwithspecificationsasunder:IntelCorei55th GenerationProcessor,8GBRAM,2TBHDD+250GBSSD, CD/DVDComboDrive,32\"Monitor,Minimum6USBports(USB 3.0/2.0),WINDOWS-7orhigherCompatipleOperatingSystem, standardkeyboard,mousewithpadandwithA3&A4ColorLaser printer.
453Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document.
454Solar panels more than 10 KW and up to 50 KW at a single location.
455Dholpur
456Kotra
457Jugarwar
458Kishangarbas

AI Tender Summary

OUR REF NO 49065013
AUTHORITY Government Departments
TENDER VALUE 2386.57 Crore
LAST DATE 16-09-2026
Authority
Authority Name Public Health Engineering Department
Work Description Work of “Construction of Intermediate CWPH at Kotra (Baseri), laying of Clear Water transmission main From Kotra to Naroli, Nadbai via junction 2 at Naroli, IPS Nadbai, Nagar, Ramgarh, Kishangarhbas Tijara (Jairolı) and Bhiwadi, from Kishanbas to Mandawar and Upto Behror, from Naroli Jn to KNP Bharatpur and Naroli Construction of CWR and Intermediate Pump Houses and Offtakes Construction of terminal CWRS at Bhiwadi and Behror inculding all alied works under Jal Jeevan Mission with 10 years O&M including one year defect liability period (Chambal Alwar Project Package-II) on Hybrid Annuity Model (HAM)”
Basic Detail
Tender No 05/2024-25
Bidding Type Tender
Location
City dholpur
State Rajasthan
Key Dates
Publish Date 15 Jun 2026
Submission Date 16 Sep 2026
Open Date 17 Sep 2026
Finance
Tender Value 2386.57 Crore
Tender Fee 1.18 Lakhs
EMD 47.73 Crore
Exemption Available
Document List
7182da0f-aedc-438c-8bc5-cc650f29a000.html
BOQ_835611.xls
TD5F.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 28, 2025
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 28, 2025
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 28, 2025
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 08, 2025
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 29, 2025
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 16, 2026
18:00 IST

Corrigendum-7 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 27, 2025
18:00 IST

Corrigendum-8 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 16, 2026
18:00 IST

Corrigendum-9 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 18, 2026
18:00 IST

Corrigendum-10 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 16, 2026
18:00 IST

Corrigendum-11 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 16, 2026
18:00 IST

Corrigendum-12 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 29, 2025
18:00 IST

Corrigendum-13 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 27, 2025
18:00 IST

Corrigendum-14 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 08, 2025
18:00 IST

Corrigendum-15 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 18, 2026
18:00 IST

Corrigendum-16 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 18, 2026
18:00 IST

Corrigendum-17 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 28, 2025
18:00 IST

Corrigendum-18 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 18, 2026
18:00 IST

Corrigendum-19 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 18, 2026
18:00 IST

Corrigendum-20 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 16, 2026
18:00 IST

Corrigendum-21 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 16, 2026
18:00 IST

Corrigendum-22 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 29, 2025
18:00 IST

Corrigendum-23 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 16, 2026
18:00 IST

Corrigendum-24 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 72 days
Oct 27, 2025
18:00 IST

Corrigendum-25 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 08, 2025
18:00 IST

Corrigendum-26 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 16, 2026
18:00 IST

Corrigendum-27 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 72 days
Sep 16, 2026
18:00 IST

Corrigendum-28 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 72 days
Jul 28, 2025
18:00 IST

Corrigendum-29 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 16, 2026
18:00 IST

Corrigendum-30 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 72 days
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 72 days
Sep 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 73 days

Tender Documents

Download All (ZIP) ↓
html

7182da0f-aedc-438c-8bc5-cc650f29a000.html

xls

BOQ_835611.xls

pdf

TD5F.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders