| 1 | Supplying, installation,Testingandcommissioning of thepassenger/goods/Stretcher or Bed elevator having following mainfeatures: (a) MOTOR : Gearless lift drive comprising of high starting torque lift duty, 3 phase 440 Volts A.C. permanent magnetic synchronous motor of proper rating with high efficiency shall be used. (b)Operation/Drive : Microprocessor based /PLC, AC Variable Voltagevariable frequency variable speed (V3F) vector control drive with encoder feedback closed loop system shall be used for lift car and door operationwhich shall be full collective selective operation hall call demand response, UP/Down hall stops, main, Up/Down contactor with overload and phase reversal relay and safety controls. (c) Traction Media: main hoist flat coated steel belt / rope. Thimbles of spring permit adjustment of uniform tension for smooth operation of the elevator Pulse belt monitoring system to avoid the cut in the belt. |
| 2 | (d) Car :car should be with M S platform with bracings of adequate sizeandtosustaintheimpactloadcabinpluspassengerswith safetyfactoroffireforsteelwithAnti-skidPVCflooringand side panels should be of Stainless steel with hair line finish of sheet of grade 304 duty with S.S. handrails . Car ceiling shall be steel finish with aesthetic appearances with LED ceiling lights .The size of the carshallbetakenasperavailableliftwellsizeand relevantBIS code of lifts. Car panel will also be ofS S 304 grade finished with emergency stopdevice,emergency alarm, mechanicaldoor safety device, fulllength infra-redcurtain in car door,facility of auto/attended mode.Allcarpanelbuttonsandall floor switches must be with brail language as per lift act. Agency shall also provide &installoneNo.2MP,IR,IPbased ceilingmountedDome Camerain thecarcompletewith connectingcables&accessories (To be connectedwithexisting CCTV systemin theBuilding) .The inspection unit shall be provided at the top of the car. (e)LandingDoors:Alllandingdoorshallbefully automatic centre opening/telescopicmadeofhairlinefinishstainless steelgrade 304 with key holes and infrared curtains with unlocking facility from outside. (f) Emergency light: Appropriate rechargeable battery operated LED emergencylightinthecarandalongwithalarmswitchshall be provided. |
| 3 | (g) ARD: Automatic rescue Device (ARD) shall be provided accordingtopassengercapacitywithSMFbatteriesof approved brands as per BSR. (h)Audio-VisualIndication:Audiovisualindicationintheliftcar, showing overloading suchthatdoors kept opentill excess loadis removed. (i) Scrolling Indicators: Digital scrolling indicator system for up-down arrowwithfloorpositionindicatorshallbeprovidedinsidethe car and at all stops/floors. (j)Buffers: Spring buffers/PUBuffersshallbeprovided. (k)CarFan: ENERGYEFFICIENTCarfan/blowerwith automatic sleep timer shall be provided. (l) Voice Annunciator: Voice annunciator with suitable music shall be provided in lift car. (m)Self diagnostics system for operational and safety parameters shall be provided in control panel. (n)Mechanical/Electronic over speed governor, door key holes in the floor doors, fireman switch shall be provided. (o)Lift machine hoisting arrangement in the lift machine room, counter balance to promote smooth and economic operation complete with steel guide rails for the car & counter weight, Trap Door, Lifting hooks as required and monkey ladders for lift pit should be provided by the agency along with all other steel structure works, foundations for the machine etc as required. |
| 4 | (p) Permanent wiring in lift machine room and in lift well with providing and fixing of electrical distribution board complete with SP & TP MCB\"s, proper numbers of light points, with LED fixtures, exhaust fan, 2 nos copper plate /chemical earthing with 8 SWG copper earth wire and plug points shall be provided by the agency. (Power supply of 3 phase 440 V shall be made available by department in lift machine room.) (q)All civil work related to installation of lift like finishing, cleaning and levelling of lift pit, white wash of lift well and in machine room shall be done by the lift erecting agency without any extra cost. (r) Granite or marble cladding around all landing door openings shall be in the scope of lift installation agency andadditional payment shall be made according to the actual measurement/schedule by the department to the lift agency. (s)Agency has to provide all working drawings and documents to comply latest BIS specifications and make proper liaison services for obtaining all necessary permissions. |
| 5 | 8 passengers/544 Kg, 3 stops, rated speed adjustable up to 1.0 mtr /sec with 2 years comprehensive maintenance / DLP |
| 6 | All in all comprehensive maintenance after defect liability period of the passenger/bed cum stretcher /goods elevator having various speed as per OEM guidelines and maintenance manual including car with all car accessories, hoist way accessories and complete with machine room accessories but excluding replacement of diffused battery bank of ARD system as per following details.8 Passenger, 544 Kg Elevator up to 5 Stops with Machine Room |
| 7 | Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 8 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 9 | 25.0 Sq. mm |
| 10 | 3.5 core |
| 11 | Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV gradedirect in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) ,with procedure as per followingpoints:- (a) Make a river sand bed of height 125 mm along the trench,(b) Lay the cable in the middle of the trench,(c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thicknessand 225 mm widejust above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 12 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 13 | Glazed door (Three phase) IK-09 and IP-43 with Metal end box |
| 14 | 8 Way |
| 15 | Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 16 | Four pole Isolator |
| 17 | 80 A/ 100 A rating |
| 18 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 19 | Single pole MCB (With B/C curve tripping Characteristics) |
| 20 | 6 A to 32 A rating |
| 21 | Earth work in excavation, including stacking/disposal of surplus material with all lifts and lead up to 50 meters, exclusive of compensation of earth [MoRTH specification : Clause 301 to 305] In ordinary Soil Mechanically by power shovel, including mechanical loading and carriage up to 50m. |
| 22 | Providing and laying in position cement concreet including curing, compaction etc completein specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8( 1 cement:4 Coarse sand: 8 graded stone aggregate 40 mm nominal size) |
| 23 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix. |
| 24 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 25 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 26 | Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricksCement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 27 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Zed BlackAbove 3601 Cm2 Slabs |
| 28 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 29 | Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick |
| 30 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete |
| 31 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding.New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 32 | Providing and Fixing Aluminium composite panel ofapproved make 3mm thick with 0.5mm thick skin & PVDF coated approved shade for wall panelling. Main framing work to be done using 50mmx25mmx1.6mm tubular section of approved make. Stainless steel screw to be used to fix the ACP panel to be fixed to the main frame with industrial adhesive tape and panel groove to be sealed with weather proof silicon sealant suitable for glass/aluminium etc. complete in all respect as approved by Engineer-in-charge. |