| 1 | (A) Jija Bai, ITI for Women, Sirifort(B) I.T.I Malviya NagarSUB HEAD (A) - I (EI & fans i/c Compound light)Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a)Group C |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a)Group C |
| 3 | Supplying and fixing following size/ modules, GI box as reuired on the site alongwith modular base & cover plate for modular switches in recess/surface etc. as required. (Make: Anchor/Havells/Northwest/Legrend) |
| 4 | 12 Module |
| 5 | 8 Module |
| 6 | 6 Module |
| 7 | 1 or 2 Module |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 9 | 5/6 A switch |
| 10 | 3 pin 5/6 A socket outlet |
| 11 | 15/16 A switch |
| 12 | 6 pin 15/16 A socket outlet |
| 13 | 6 Amp 3 Pin Plug top with indicator |
| 14 | 16 Amp 3 Pin Plug top with indicator |
| 15 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 16 | 3 x 1.5 sq. mm |
| 17 | 3 x 2.5 sq. mm |
| 18 | 3 x 4 sq. mm |
| 19 | 3 x 6 sq. mm |
| 20 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 21 | 20 mm |
| 22 | 25 mm |
| 23 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 24 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 25 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 26 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)a)12 way (4 + 36), Double door |
| 27 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 28 | Single pole |
| 29 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 30 | 100 A |
| 31 | Supplying and replacement, installation, testing & commissioning of 15watt capacity surface/recess mounted LED downlighter luminaires with aluminium housing having lumen output > 100 lumens/watts, surge protection> 2.5 KV, cool light (5700 k to 6500k) power factor> 0.90, CRI> 70 with integrated electronic driver, testing & commissioningi/c connection of wires with 1.5 sqmm FRLS PVC insulated wires i/c credit of old dismantle material etc complete as required as reqd. |
| 32 | Supplying and replacement, installation, testing & commissioning of 4 feet, 20-22watt capacity wall mounted LED batten fitting with extruded aluminum housing having lumen output> 100 lumens/watt in cool daylight (5700 k to 6500k) power factor> 0.90 CRI> 70 surge protection >, 2.5 kv with integrated electronic driver suitable for mirror light i/c connection of wires with 1.5 sqmm FRLS PVC insulated wires i/c credit of old dismantle material etc complete as required as reqd. etc complete as reqd. |
| 33 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 34 | Supplying, installation, testing & Commissioning of 80Watt TURBO LED Flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminum extrusion with IP66 i/c connection with all accessories i/c credit of old dismantle material etc. complete as required. |
| 35 | Taking out submersible pump set with GI pipe submersible cable, rope wire etc from the bore well with the help of chain pulley block and tripod etc complete as reqd. |
| 36 | Replacement, Lowering , testing & commissioning 5 HP35 stage 3 phase 415 volts Submersible pump set ,Head – 120Mt. in the existing bore well with help of chain pulley block tripod i/c credit of old dismantle material etc.complete as reqd. |
| 37 | Replacement and Fixing lowering of following size of G.I. pipe, medium class i/c providing & fixing 6mm thick G.I. flange duly welded on both ends of the pipe at 3mtr interval complete with rubber packing , nuts and bolts for making water tight connections i/c credit of old dismantle material etc as reqd. |
| 38 | a) 50mm dia |
| 39 | Supplying and Fixing 3 core 4 sq mm PVC insulated PVC sheathed flat cable copper conductor for submersible Motor complete i/c credit of old dismantle material etc as reqd. |
| 40 | Replacement and fixing following accessories in the existing delivery pipe line i/c cutting threading i/c less credit of old dismantle material etc. complete as reqd. :- |
| 41 | 50mm dia Gate valve |
| 42 | 50mm dia NRV |
| 43 | Replacement and fixing Submersible Pump Controller for 5 H.P capacity in Sheet Enclosure type MU-G (motor rating AC-3 Duty, 415Volt, 50 Hz,3 Phase i/c connection , testing i/c credit of old dismantle material etc. as reqd. |
| 44 | Supplying and fixing of 3mm thick phenolic laminated sheet i/c cutting the sheet as per required size etc. complete as required. |
| 45 | Replacement of recess type 34W to 36W Full window glarefree opal Diffuser LED Panel of size 595X595mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 34W to 36W LED should be 3300 or above in Cool day Light(5600K to 6500K), Power factor>0.90, CRI (Ra) >80, Complete with all accessories as required with connections i/c credit of old dismantle material etc. complete as required. |
| 46 | Replacement of surface type 34W to 36W Full window glarefree opal Diffuser LED Panel of size 595X595mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 34W to 36W LED should be 3300 or above in Cool day Light(5600K to 6500K), Power factor>0.90, CRI (Ra) >80, Complete with all accessories as required with connections i/c credit of old dismantle material etc. complete as required. |
| 47 | SUB HEAD (B) - I (EI & fans i/c Compound light)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(a) Group C |
| 48 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required.(a) Group C |
| 49 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel / PVC conduit as required. |
| 50 | 3 X 1.5 sq.mm |
| 51 | 3 X 4 sq.mm. |
| 52 | 3 X 6 sq.mm |
| 53 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 54 | 5/6 A Switch |
| 55 | 3 Pin 5/6 A Socket Outlet |
| 56 | 15/16 A Switch |
| 57 | 6 Pin 15/16 A Socket Outlet |
| 58 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required |
| 59 | 20 mm |
| 60 | 25 mm |
| 61 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 62 | 8 Module (125 mmX125 mm) |
| 63 | 12 Module (200 mmX150 mm) |
| 64 | Replacement of recess type 34W to 36W Full window glarefree opal Diffuser LED Panel of size 595X595mm suitable for Armstrong/POP/GB ceiling with MS Powder coated White Housing. Total system Lumen of 34W to 36W LED should be 3300 or above in Cool day Light(5600K to 6500K), Power factor>0.90, CRI (Ra) >80, Complete with all accessories as required with connections. |
| 65 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 66 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 67 | Replacement of 900 rpm 300mm sweep exhaust fan metal bodycomplete with louvers/ shutters in the existing opening i/c making the hole to suit the size of the above fan making good the damage & connections etc. as reqd. |
| 68 | Replacement of Surface/Wall Mounted 1 X 20W LED Tube With4 feet MS Batten Fitting, LED Tube should have extruded aluminium housing for efficient heat dissipation. Total system Lumen of 20W Led should be 1700 or above in Cool day Light(5700K to 6500K), Power factor>0.90, CRI>80. Complete with Mounting Brackets & accessories as required with connections. |
| 69 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as required. |
| 70 | Single Pole |
| 71 | Single Pole and Neutral |
| 72 | Double Pole |
| 73 | Replacement of 120WattLED Flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminum extrusion with IP66 i/c connection with all accessories etc. complete as required. |
| 74 | S/I/T/C of weatherproof box made out of hot moulded SMC sheet with clamp, neutral link, strip, gland, thimble and 1 No. 10 Amps. SP MCB complete with inter connection, earthing etc as reqd.(Box Size: 300mm X 200mm X 105mm) |
| 75 | Replacement of wall mounted cabin fan 400 mm sweep suitable for operating on 230 volt single phase AC supply i/c connection with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable earth etc as reqd. |
| 76 | Replacement of 2.50 mfd fan condensor for ceiling fan i/c connection testing etc. complete as required. |
| 77 | Supplying and fixing of 3mm thick phenolic laminated sheet i/c cutting the sheet as per required size etc. complete as required. |
| 78 | SUB HEAD (B)- II (AMC of DG Set)AMC of following capacity Kirloskar Make DG Set installed at ITI Malviya Nagar, New Delhi i/c monthly visit at site, attending breakdown complaint on 24 X 7 basis cleaning of filters, checking of lubricat oil, checking of spare parts, recording of preventive maintenance parameters i/c 2 No. B check services etc. as per given terms and conditions.a)125 KVA DG Set - 1 No |
| 79 | Repair and replacement of following parts of 125 KVA DG Set Kirloskar Make i/c testing etc. as reqd. |
| 80 | Spin on Filter for Lubricating Oil (06.436.1.0.00) |
| 81 | Primary Element (3H.132.01.0.00) |
| 82 | Secondary Element (3H.132.02.0.00) |
| 83 | Element Air Cleaner (F6.986.11.0.00) |
| 84 | Safety Element Air Cleaner (F6.986.12.0.00) |
| 85 | K Cool Super Plus Premix 26 Lts. Can (82.020.35.1.26) |
| 86 | Koel Care Premium Oil 20 Lts. |
| 87 | Radiator Descaling Charges |
| 88 | Battery Water 5 Lts Cane |
| 89 | SUB HEAD (B)- V (Credit of old dismantle material)Less Credit offollowing Old dismantle materials as and where basis etc. complete as required. |
| 90 | Assorted Copper wire |
| 91 | 20 Watt Fitting |
| 92 | Exhaust Fan |
| 93 | Flood Light |
| 94 | Ceiling Fan |
| 95 | Recess Fitting 2 X 2 Fitting |
| 96 | Wall Fan |
| 97 | Switch/Socket/Regulator(Assorted) 5A/16A |
| 98 | MS Box/Conduit/Angle iron Board/Strip, rusted DB etc. |