Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SITE CLEARENCE AND COMPOUND WALL |
| 2 | 2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil |
| 3 | 50.2.33.5 Cutting branches of trees overhanging above any structures of girth between 40cm to 60cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete. |
| 4 | 50.2.33.6 Cutting branches of trees overhanging above any structures of girth between 60cm to 90cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete |
| 5 | 50.2.33.7 Cutting branches of trees overhanging above any structures of girth between 90cm to 120cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete. |
| 6 | 50.2.33.8 Cutting branches of trees overhanging above any structures of girth beyond 120cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete. |
| 7 | 15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 8 | 6.1.1 Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 9 | 50.6.1.2 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete. |
| 10 | od5120/2025_2026 Cleaning the surface and removing dirt,dust,greese,oil,algae,fungus including washing the surface with the help of required srubbers and cleaning with machine operated water jet etc. Without causing any damage to the existing structure |
| 11 | 14.17 Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead. |
| 12 | 4.1.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) |
| 13 | 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 14 | 13.111.1 Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 15 | 13.99.1 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work |
| 16 | 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 17 | od5133/2025_2026 Taking out demolished compound wall fencing including cutting and stacking within 50 metres lead:Of area 3 sq. metes and below |
| 18 | 15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 19 | 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm |
| 20 | 15.13.1 Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metes and below |
| 21 | 15.6 Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 22 | od5149/2025_2026 Engaging labour for petty work |
| 23 | od5153/2025_2026 Taking out and stacking damaged cover slabs of existing drain at Arjunan master round |
| 24 | od5154/2025_2026 Taking out roofing sheets without damaging structural frame work and stacking the material within 50 metres lead of :G.S. Sheet at Arjunan master ground |
| 25 | 10.25.2 Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 26 | od5159/2025_2026 Cleaning the drains by removing debris such as accumulated sand, mud, clay, plastic, decayed vegetation, overgrown vegetation etc. inside the drain including all labours lift upto 1.5m ang lead upto 50m and disposal of debris upto a distance of 5km etc. complete as per the direction of departmental engineers in charge (based on 2.8.1- Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.) |
| 27 | od5160/2025_2026 Removing the existing cover slabs of average carefully without damaging the cover slab for the purpose of cleaning the drain and relaying the slab after cleaning, including all labours etc. complete as per the direction of departmental engineer in charge |
| 28 | 5.9.16.1 Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 29 | 5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 30 | 5.22.1 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars |
| 31 | od5164/2025_2026 Engaging labour for Cleaning Of common areas,yard and toilet at kaloor market |
| 32 | 30.2.2 Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 33 | 30.2.3 Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment). |
| 34 | 15.2.2 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) |
| 35 | 15.19 Dismantling steel work manually / by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per directions of Engineer -in-Charge. |
| 36 | STAGE AND BUILDING |
| 37 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 38 | 50.2.3.1 Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete |
| 39 | 4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 40 | 15.7.1 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In mud mortar |
| 41 | 60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site |
| 42 | 7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 43 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 44 | 4.3.1 Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 45 | 5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 46 | 5.9.16.1 Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 47 | 5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 48 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size |
| 49 | 50.6.1.4 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete |
| 50 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 51 | 5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 52 | 5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 53 | 5.9.7 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) |
| 54 | 50.6.1.6 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete |
| 55 | 50.6.3.2 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete |
| 56 | 5.9.3 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 57 | 5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 58 | 11.20.1 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement |
| 59 | 10.26.1 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube |
| 60 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 61 | 5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 62 | 6.1.1 Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 63 | 14.1.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) |
| 64 | 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 65 | 13.8 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 66 | 13.16.1 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 67 | 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 68 | 9.17A.3 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). |
| 69 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 70 | 9.48.1 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 71 | 9.121 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 72 | 9.122.1 Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. |
| 73 | 9.141 Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (±0.2mm), made out of single piece extruded PVC profile, with mitred cut joints and with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8x100 mm long anchor fasteners complete, all as per manufacturer\"s specification and direction of Engineer-in--charge. |
| 74 | 9.142.1 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded solid PVC ( ±0.2 mm) thick, having styles & rails (except lock rail ) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinges side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm x 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm x 100 mm of cross section size 35 mm x 17 mm s 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm x 35 mm, out of which 95 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer\"s specification and direction of Engineer-in-charge.Non decorative finish (matt finish) |
| 75 | 9.165.1 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm |
| 76 | 9.70.1 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete:125x64x1.90 mm |
| 77 | 9.101.1 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper |
| 78 | 21.11.1 Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.205 x 19 mm |
| 79 | 21.15.2 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium |
| 80 | 9.97.3 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm |
| 81 | 0.9.15.2 Supplying and fixing 300 mm Aluminium aldrop |
| 82 | 13.48.3 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 83 | 12.1.1 Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 84 | 12.7.1 Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2 |
| 85 | 10.6.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 86 | od5170/2025_2026 supplying , providing and fixing V board vertical panels as per required size with aluminum channel frame work with screws as per direction of engineer in charge |
| 87 | od5172/2025_2026 Providing and fixing CNC Sheets for required design made of 4 mm thick Sheet with GI pipe frame , welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 88 | od5173/2025_2026 Water proofing on the terrace roof using Berger paints home shield PU roofkoat white. Including cleaning, dust removal and crack filling using crack filler available in market. Applying 3 coats of PU roofkoat while 1st coat 50% dilution as priming coat 2nd and 3rd coat without dilution.(13.61.1) |
| 89 | od5174/2025_2026 Finishing walls with 100% Premium acrylic emulsion paint having VOC lessthan 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungalTinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and includingpriming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 90 | 10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 91 | 13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 92 | od5176/2025_2026 Dismantling tile work in vertical walls laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 93 | 15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 94 | PLAY & GYM EQUIPMENTS |
| 95 | od5096/2025_2026 Supplying and fixing TRIPLE SWING SET including cost of materials, transportation and fixing charge- QUOTATION FROM PLAYZONE or Equivalent |
| 96 | od5097/2025_2026 Supplying and fixing Double swing for children - SW03 - MT Industrials or Equivalent |
| 97 | od5099/2025_2026 Supplying and fixing CLIMBER PLAY EQUIPMENT - TC03 - MT INDUSTRIALS or Equivalent |
| 98 | od5100/2025_2026 supplying ,providing and placing of outdoor seat twister at site with primer and required finishes of paint including loading , unloading ,carriage etc and as per direction of officer in charge. at Arjunan master Ground |
| 99 | od5102/2025_2026 supply, providing and placing of outdoor single cross trainer at site with primer and required finishes of paint including loading, unloading, carriage,etc and as per direction of officer in charge at arjunan master ground |
| 100 | od5104/2025_2026 supplying and fixing MULTI PLAY STATION (FRP & GI) LFO MPS 06 as per the direction of engineer in chargeat Arjunan master cultural centre |
| 101 | PLUMBING |
| 102 | 18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 103 | 18.52.1 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore |
| 104 | 18.8.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes |
| 105 | 18.8.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes |
| 106 | 5) 18.9.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work25 mm nominal outer dia pipes |
| 107 | 18.9.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work32 mm nominal outer dia pipes |
| 108 | od5109/2025_2026 Supply, installation, testing & commissioning of Water lifting pump, with pumps (2 nos on a 1duty + 1 standby basis) with control panel,automatic changover switch, with all necessary valves, flexible connections, pressure gauges, strainers, supports, fixings and fittings electrical/ control panels, power and control cabling , cable trays, automatic level controller, etc. as specified and as shown on drawings and complying to relevant standards. |
| 109 | 18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 110 | 18.17.1A Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore |
| 111 | od5117/2025_2026 Supply, installation, testing and commissioning of high pressure float valve with bronze construction, brass floats, with screwed end fittings with all supports and fixings all as specified and as shown on drawings and complying to relevant standards32mm dia |
| 112 | od5119/2025_2026 Supply, installation, testing and commissioning of high pressure float valve with bronze construction, brass floats, with screwed end fittings with all supports and fixings all as specified and as shown on drawings and complying to relevant standards20mm dia |
| 113 | 17.81 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 114 | 17.7.9 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked |
| 115 | 17.4.1 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 116 | 50.17.1.1 Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 117 | 16) 50.17.1.2 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 118 | 50.17.1.4 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. |
| 119 | 17.34.1 Providing and fixing toilet paper holder:C.P. brass |
| 120 | od5136/2025_2026 Supply, installation and commisiioining charges for Floor Drain Outlets including, accessories, bolts/screws, washers, etc. as applicable, complete including making good the wall as per Architectural drawings and as relevant standards.125X125 1.2mm thick SS 304 grade lockable type floor drain |
| 121 | 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 122 | od5152/2025_2026 Providing and placing a polyethylene water storage tank :ISI 12701 marked,in UG tank with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. od 18.48 |
| 123 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 124 | 18.61.4 Providing and fixing C.I dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373 :20 mm dia |
| 125 | 18.37.1 Constructing masonry chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand) for water meter complete with C.I double flap surface box 400x200x200 mm ( inside ) with locking arrangement and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grades stone aggregate 20 nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 |
| 126 | 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 127 | 4.1.11 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) |
| 128 | od5165/2025_2026 Supply and fixing of CI manhole frame and cover of lockable type ( Double Sealed ) over openings of under ground sump, overhead tank,rain water Sump, soak pits.600X600 Manhole cover with medium duty |
| 129 | 50.18.9.14.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall |
| 130 | 50.18.9.16.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall |
| 131 | 50.18.9.17.1 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall |
| 132 | 50.18.9.18.1 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 133 | 50.18.9.20.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow |
| 134 | 50.18.9.20.3 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow |
| 135 | 50.18.9.20.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend |
| 136 | 50.18.9.21.7 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 137 | 50.18.9.22.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 138 | 50.18.9.22.3 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 139 | 50.18.9.22.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 140 | 50.18.9.22.8 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 141 | 50.18.9.22.10 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap |
| 142 | 50.18.9.9.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 143 | 50.18.9.19.1 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 144 | 50.18.8.8.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2 |
| 145 | 50.18.9.8.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2 |
| 146 | od5171/2025_2026 Supply, Installation, testing and commissioninh of drainage fixtures and accessories including cutting and making good the wall/slab all in accordance with the drawings and relevant standards.uPVC deep seal multiple floor Trap |
| 147 | 19.4.1.2 Providing and fixing square-mouth S.W. gully trap class SP -1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith Sewer bricks conforming to IS: 4885 |
| 148 | 19.7.1.2 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885 |
| 149 | od5175/2025_2026 Providing and placing Ferro cement UG soak pit with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per the direction of engineer in charge. 40 flush capacity od 51.19.ST1 at Arjunan master cultural centre |
| 150 | od5177/2025_2026 Providing and placing Ferro cement UG septic tank with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per the direction of engineer in charge. 40 flush capacity od 51.19.ST1 At Arjunan master ground |
| 151 | od5178/2025_2026 Providing and placing Ferro cement tank, in UG water tank with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per the direction of engineer in charge od 18.48 |
| 152 | 16.78.1 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 |
| 153 | INTERIOR WORKS |
| 154 | 50.9.12.1 Providing and fixing Thomson Multi wood board or equivalent make, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately) as per the direction of site Engineer-in-charge. |
| 155 | 21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 156 | 9.79.1 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.40 mm |
| 157 | 9.8 Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. |
| 158 | 9.114.2 Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters, including fixing with necessary screws etc. complete.Double strip (horizontal type) |
| 159 | 9.165.1 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm |
| 160 | 9.70.1 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete:125x64x1.90 mm |
| 161 | Electrical Works-Stage Building |
| 162 | 1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 163 | 1.55.3 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 164 | 1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 165 | 1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 166 | 1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 167 | 1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 168 | 4.1.2 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 169 | 1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 170 | 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 171 | 1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch15/16 amp switch |
| 172 | 1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 173 | 1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 174 | 90.10.3.33 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 175 | 1.24.6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 176 | od5115/2025_2026 Supply and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.RJ 45 Socket Outlet |
| 177 | 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 178 | 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 179 | 1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 180 | 1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 181 | 1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 182 | 1.27.5 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 183 | 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 184 | 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door |
| 185 | 90.11.1.10 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required.4 way (8+12) - three phase double cover (IP 42/43) |
| 186 | 2.5.1 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (but without MCB\"s and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door |
| 187 | 2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 188 | 2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 189 | 2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 190 | 2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 191 | 2.15.1 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 192 | od5139/2025_2026 Supplying and fixing following 25 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 193 | od5141/2025_2026 Supply, Installation, Testing and Commissioning of 250mm sweep Light Duty Exhaust fan in plastic body with self opening louvers working on 230 V single phase A/C. |
| 194 | od5144/2025_2026 Supply, Installation, Testing and Commissioning of 380 mm sweep, 900 rpm Heavy Duty Exhaust fan with louvered shutter working on 230 V A/C supply. |
| 195 | od5146/2025_2026 Supplying and fixing of modular type 32 A DP switch with indicator on the existing modular plate & switch box including connections etc. as required. |
| 196 | od5147/2025_2026 Supply, Installation, Testing & Commissioning of 400mm sweep 5 star rated BLDC Wall mounting oscillating type fan of approved make with remote control including all accessories of approved make as required for use on 240V AC supply. |
| 197 | od5148/2025_2026 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated BLDC ceiling fan of approved make without remote control complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C. |
| 198 | od5150/2025_2026 Supplying and fixing of 40 A to 63A rating, 415V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple Pole Neutral |
| 199 | od5151/2025_2026 Supply & fixing of 9 W LED bulb including angle batten holder with advanced international interlock configuration of approved make |
| 200 | od5155/2025_2026 Supply, Installation, Testing & commissioning of 10 W LED Bulk head fixture of approved make complete with all accessories as required suitable for 240V AC supply. |
| 201 | od5156/2025_2026 Supply, Installation, Testing & commissioning of 20 W LED Batten of approved make with output of minimum 2000 lumen complete with all accessories directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required suitable for 240V AC supply. |
| 202 | od5157/2025_2026 Supply, Installation, Testing and Commissioning of 1 KVA, single phase UPS with 12 V battery of 15 minutes back up including all accessories of reputed make |
| 203 | 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 204 | 2.18 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 205 | od5162/2025_2026 Supply, Installation, Testing & Commissioning of 1 HP monoblock pump with all related accessories complete as instructed by engineer in charge. |
| 206 | od5163/2025_2026 Supply, Installation, Testing & Commisioning of 2HP, 38mm outlet, water filling type borewell submersible pumpset, having a head range of 23 to 106mts and a corresponding discharge rate range of 90 to 17LPM and capable of discharging 3000lts/hr at a head of 86mts, suitable for borewells of size 100mm or more and for operation on AC single phase supply. The pump is fitted with Noryl impellers and motor body is Stainless steel. Capacitor box consisting of AC contactor, suitable value Start / Run capacitors, ammeter / voltmeter, suitable for 2HP borewell submersible pumpset. |
| 207 | MORTH ITEM |
| 208 | 55.22 Supplying and laying interlocking tile 100 mm or nearest size thickness, minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc.; complete. |
| 209 | LANDSCAPE WORK |
| 210 | 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 211 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 212 | 60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site |
| 213 | 7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 214 | 50.6.1.8 Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete |
| 215 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 216 | 5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 217 | 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size. |
| 218 | 8.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm |
| 219 | 8.3.2 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work |
| 220 | 5.9.16.1 Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 221 | 5.3 Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 222 | 5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 223 | 13.7.2 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) |
| 224 | 13.8 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 225 | 9.121 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 226 | 9.122.1 Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames. |
| 227 | 21.1.1.3 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPolyester powder coated aluminium ( minimum thickness of polyester powder coating 50 micron ) |
| 228 | 21.1.2.1 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately).Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15) |
| 229 | 21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness |
| 230 | 9.48.1 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding |
| 231 | 10.15.1 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular /L-Type sections, made of 1.60 mm thick M.S. Sheet,joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 232 | 10.5.1 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
| 233 | 13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 234 | 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm): |
| 235 | od218568/2024_2025 Logo making in steel plate with vinyl |
| 236 | od218569/2024_2025 For making of Stainless Steel Letters 304 grade in vinyle plate |
| 237 | 10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 238 | 12.1.1 Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2 |
| 239 | 10.26.1 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.M.S. tube |
| 240 | 15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 241 | 4.1.5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 242 | 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 243 | 6.2.1 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 244 | 11.20.1 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Light shade pigment using white cement |
| 245 | 4.6.1 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size) |
| 246 | 16.91.1 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 247 | od218573/2024_2025 Providing and laying factory made grass lock edge Cement Concrete paver blocks in footpath, parks, lawns, etc, of required strength,thickness & size/ shape, made by table vibratory method usingPU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layerlayer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern at arjunan master ground walkway. |
| 248 | 13.52.2 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work |
| 249 | od218574/2024_2025 Supplying, Providing & placing of park seating benches with cast iron frame with wooden seating and of size 60\" L, 16\"W, 20\" H at site with primer and required finishes of paint including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. |
| 250 | od218575/2024_2025 Supplying and fixing ready made waste bins at necessary location - 22inch width and 3 ft height |
| 251 | 15.23.2 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm |
| 252 | 15.7.4 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 253 | 50.6.2.1 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete |
| 254 | 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 255 | od218576/2024_2025 Engaging labour for petty repair works.coolie |
| 256 | 15.60 Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 257 | GARDENING |
| 258 | od218539/2024_2025 Planting CALADIUM PLANTS by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.90cm height |
| 259 | od218542/2024_2025 Planting by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of RAPHIS EXCESSA,40CM HEIGHT |
| 260 | od218543/2024_2025 Planting trees by Digging pit in all kinds of soil and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods, covering the stem with necessary hay etc., caring and protecting the plants transported and unloaded at site till planting in pits of size 120 cm diameter, and 120 cm deep, TERMINALIA VARIEGATED. Appropriate Length of softwood props shall be provided as supports for the plants as directed. The trees have to be maintained for a period of 3 months after the entire planting of trees is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete.TERMINALIA VARIEGATED 180CM |
| 261 | od218546/2024_2025 Planting trees by Digging pit in all kinds of soil and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods, covering the stem with necessary hay etc., caring and protecting the plants transported and unloaded at site till planting in pits of size 120 cm diameter, and 120 cm deep, DRACAENA FRAGRANS 1.80 M HEIGHT . Appropriate Length of softwood props shall be provided as supports for the plants as directed. The trees have to be maintained for a period of 3 months after the entire planting of trees is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 262 | od218547/2024_2025 Planting HIMENOCALLIS LITTORALIS b by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 263 | od218548/2024_2025 Planting PHILADENDRON SELLOUM PLANTS by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 264 | od218549/2024_2025 Planting ALPINIA PURPORATA 6 by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 265 | od218551/2024_2025 Planting trees by Digging pit in all kinds of soil and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods, covering the stem with necessary hay etc., caring and protecting the plants transported and unloaded at site till planting in pits of size 120 cm diameter, and 120 cm deep, PLUMARIA OBTUSA - 2.5 M . Appropriate Length of softwood props shall be provided as supports for the plants as directed. The trees have to be maintained for a period of 3 months after the entire planting of trees is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 266 | od218552/2024_2025 Planting EZHILAM PALA 1.2 M by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 267 | od218555/2024_2025 Planting Burmuda grass by excavating planting bed 30 cm deep at specified area shown in the planting plans and preparing the same with thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying and planting Grass Buffalo grass sod, machine cut at a uniform soil thickness of 15 mm, plus or minus 6 mm, at the time of cutting, measurement for thickness shall exclude top growth and thatch. Individual pieces of Buffalo grass sod shall be cut to the supplier’s standard width and length. Maximum allowable deviation from standard widths and lengths shall be plus or minus 15 mm on width and plus or minus five percent on length. Broken pads and torn or uneven ends will not be acceptable. Standard size sections of Buffalo grass sod shall be strong enough that it can be picked up and handled without damage. Buffalo grass sod shall not be harvested or transplanted when its moisture content (excessively dry or wet) may adversely affect its survival. Before harvesting, the turfgrass shall be mowed uniformly at a height of 25 to 60 mm on winter season grasses and 20 to 40 mm on summer season. Grass turfgrass sod should be transported unloaded at site with care and protection and without any damage. The planted Grass turfgrass have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Grass , cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 268 | od218557/2024_2025 Planting HELICONIA PSITTACORUM PLANTS by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 269 | od218558/2024_2025 Planting CALATHEA LUTAE PLANTS by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 270 | od218559/2024_2025 Planting WHITE CLEMATIS VINES by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. |
| 271 | od218560/2024_2025 Planting HELICONIA PSITTACORUM by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the plants transported and unloaded at site. The plants have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete.45cm height |
| 272 | Electrical Works-Exterior |
| 273 | 14.15.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal) |
| 274 | 90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 275 | 90.6.5.13 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm |
| 276 | 90.12.5.38 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm |
| 277 | 90.12.5.39 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm |
| 278 | 90.12.5.40 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm |
| 279 | 90.12.5.41 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm |
| 280 | 90.12.7.39 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm |
| 281 | 90.12.7.40 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 282 | 90.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 283 | 90.16.1.11 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG) |
| 284 | 2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 285 | od226190/2024_2025 Supply, Installation, Testing and Commissioning of Nickel coated Copper bonded electrode made from low carbon steel. Earth rods and molecularly bonded with 99.9 % pure electrolytic copper with 250 micron coating, 17.2 mm dia with pressed contact including stainless steel nut, bolts and washers.Copper bonded rod of size (17.2mm x 2000mm) with chemical bag with all accessories.The earth rod should be properly covered with UV resistant earth pit Chamber complied to IEC62561-5 including boring of earth pit suitable for the earthing to be done as per the dimension of earth rod. |
| 286 | od226191/2024_2025 Supply, Installation, Testing and commissioning of Architectural LED Bollard (8W-15W) upto one metre height suitable for on ground installation is made of extruded/die cast aluminium body with powder coating in standard colour as approved by engineer in charge. The luminaire shall have ingress protection of minimum IP 65 rating. The Luminaire should have min luminaire efficacy of 45 lm/W and system lumen o/p of min. 700 Lumen, CRI >70, with CCT of (3000-4000)K. The LED chip shall be comply to LM80-08 standard with estimated LED life time L70 @ 50,000 hours. The BIS certified driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 140V to 280V, I/P frequency range of 50-60Hz with 4 KV built-in surge protection and with power factor 0.90 with total harmonic distortion (THD) of less than 10%. |
| 287 | od226192/2024_2025 Supplying and laying of 25 mm weather proof Corrugated PVC flexible conduit of approved make |
| 288 | od226193/2024_2025 Supply and Installation of outdoor weather proof IP66 rated Junction Box including associated accessories of approved make. |
| 289 | od226194/2024_2025 Supplying and making end termination with aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required for input and output of cable 3 x 4 sq.mm in flush terminal box of pole.. |
| 290 | od226195/2024_2025 Supplying and making end termination with aluminium lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1KV grade as required for input and output of the cable 4 X 4 Sq.mm in flush terminal box of pole. |
| 291 | od226837/2024_2025 Dismantling of existing light/electric poles and fitting whether required without damage and transportation and stacking of all materials to respective store of concerned department as per the instruction from engineer in charge. |
| 292 | od226838/2024_2025 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (22mm) |
| 293 | 9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 294 | 9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 295 | od226196/2024_2025 Supplying and fixing of following sizes of heavy duty class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 296 | od226198/2024_2025 Supply, Installation, Testing & Commissioning of 7W Outdoor type step lights of approved make |
| 297 | od226738/2024_2025 Supply, Installation, Testing & Commissioning of LED Gate piller light suitable for post top mounting having 45 Watts, with the body of aluminium, tempered glass fixed on to the body, IP66 optical & control gear compartments, overall system efficiency of 115 lm/ W at correlated CCT of 3000-4000K, CRI > 70 and L70 rated lifetime of 50,000 hours, Impact resistance IK08, optical tightness IP66. Electrical Class I, rated voltage 240 Vac, power factor>0.95, with BIS certified potted driver having internal surge protection of 4 KV and an additional surge protection of 10KV. |
| 298 | od226739/2024_2025 Supply, Installation, Testing, Commissioning of Post Top Mounting Type LED Decorative Luminaire having system wattage 40W with 120 lm/W having LED Chips of CREE/ NICHIA/ OSRAM/ SEOUL/ LUMILEDS make.The housing material should be spun Aluminium and polycarbonate protector, CCT of 3000-4000K, CRI 70, LED Life expectancy @L70 > 50000 hrs, IP66 ingress protection, Impact ressitance - IK09, Constant Current LED having Efficiency > 85%, Power Factor>0.95, THD< 10% Operature Temperature -10 deg C to + 50deg C. Systemwhich offers Protection against Short Circuit, Over- Voltage & Over- Current with in-built surge protection up to 4kv and an additional surge protection device of 10kV. LM report should be submitted from UL Authorised Laboratory. Sample should be submitted for approval from concerned engineer-in charge. |
| 299 | od226740/2024_2025 Supply, Installation, Testing & Commissioning of LED High bay light with system wattage of 150 Watts, Ingress Protection of IP65, Luminous Flux ≥ 130 LM ±10% / per watts, CRI ≥ 80 Ra, Kelvin color temperature of 3000K-4500K, THD <10% ± 10%, 6 KV surge protected of reputed make. |
| 300 | od226741/2024_2025 Supply, installation, testing and commissioning of 300 W LED Flood light output greater than 120 lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM 79 & 80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 301 | od226742/2024_2025 Supply installation testing and commissioning of Stadium Mast using Octogaonal Pole made of Monkey type ladder arrangement for mounting upto 6/8 nos. LED Flood Light Fixtures Complete with all related accessories excluding internal cabling work suitable for wind speed as per IS 875 including connector foundation bolt and lightening spike in existing RCC foundation. 12 Meters |
| 302 | od226743/2024_2025 Supply & Installation of 3M Height Architectural Post Top Pole along with Ornomental Cast Iron Components. The hot dip Galvanised pole should be provided with an inbuilt junction box to fix 32A connectors and 6A MCB, at the bottom - the inbuilt box should have a flush door of suitable size. The decorative pedastal to be mounted on a suitable size steel plate. This mounting steel plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole design. Pole & it\"s parts are painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint. |
| 303 | od226802/2024_2025 OUT DOOR HIGH MAST LIGHTING PANEL: Supply, Installation, Testing & Commissioning of Outdoor High Mast Lighting Panel cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 65, floor mounting, dust and vermin proof, outdoor type with canopy, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The panel shall be suitable for Bottom Entry & Exit cables.Incomer:40A,10kA FP MCB -1 no.Bus Bar:TPN bus bar chamber with 40 A, 10 kA Aluminium bus bar (P=N) + Cu earth bus.Instruments:Multifunction Meter, control MCB Indication Lamps,CTs as per SLD,ON/OFF/TRIP indication LampsOut goings:25A, 10kA MCB + 25A100mA DP RCCB -8 nos.General danger notice board/Name plates shall be provided. |
| 304 | od226803/2024_2025 MAIN SWITCH BOARD (MSB) : Supply, Installation, Testing & Commissioning of LT Main switch board cubicle made out of 2mm thick CRCA sheet, totally enclosed, IP 42, Wall/floor mounting as per the requirement, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be suitable for top entry & exit cables.Incomers:63A FP COS- 1 set63A 16 kA, FP Microprocessor based Moulded Case Circuit Breaker-1 NoType 1+2 SPD -1 no.Bus Bar:TPN bus bar chamber with 63 A, 16 kA Aluminium bus bar (P=N) + Cu earth bus.Instruments:Multifunction Meter, control MCB Indication Lamps,CTs as per SLD,ON/OFF/TRIP indication LampsOut goings:40 TPN MCB-2 no.25A TPN MCB-3 nos.General danger notice board/Name plates shall be provided. |
| 305 | od226804/2024_2025 METERING PANEL: Supply, Installation, Testing & Commissioning of LT Outdoor Metering Panel cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 65, wall / floor mounting, dust and vermin proof, outdoor type with canopy, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc. The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The panel shall be suitable for top entry cablesIncomer:63 A cut out fuse - 3nos.Provision for LT TOD Meter with CTs (0.5S),PT(0.5) ,63/5AInstruments:Control MCB, RYB Indication Lamps, CBCT & ELR (30-300 mA)- 1 set as per the SLD, ON/OFF/TRIP indication as per SLD,Out goings:63A 16 kA TP+NL Thermal Magnetic based Moulded Case Circuit Breaker - 1Nos.General danger notice board/Name plates shall be provided. |
| 306 | od226817/2024_2025 LANDSCAPE LIGHTING PANEL: Supply, Installation, Testing & Commissioning of LTLandscape Lighting Panel cubicle made out of 2mm thick CRCA sheet, totally enclosed, IP 42, Wall mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing & specification. The Panel shall be suitable for top entry & exit cables.Incomer:25A,10kA FP MCB -1 no.Suitable contactor and Timer arrangement withstanding total load current.-1 setBus Bar:TPN bus bar chamber with 25 A, 10 kA Aluminium bus bar (P=N) + Cu earth bus.Out going16A, 10kA, 100mA FP RCBO -6 no16 A 10 kA 100mA DP RCBO- 2nosGeneral danger notice board/Name plates shall be provided. |