}

Tender For Re-Electrification Work Of Office Building Of State Tax Department (G.S.T) In Dist.Amroha. - Rewiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq, amroha-Uttar Pradesh

Public Works Department has published Tender For Re-Electrification Work Of Office Building Of State Tax Department (G.S.T) In Dist.Amroha. - Rewiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq. Submission Date for this Tender is 15-05-2025. Electrification Work Tenders in amroha Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

49059083
Tender For Re-Electrification Work Of Office Building Of State Tax Department (G.S.T) In Dist.Amroha. - Rewiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq
Open Tender
NCB
Uttar Pradesh
Amroha
15-05-2025

Tender Documents

Tender Details

Tender For Re-electrification work of office building of State Tax Department (G.S.T) in Dist.Amroha. - Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C 2 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) 3 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.3 Module (100mmX75mm) 4 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm) 5 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.6 Module (200mmX75mm) 6 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.8 Module (125mmX125mm) 7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch 8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6 A switch 9 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 10 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.1x1.5sq. mm (for inverter wiring ) 12 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X 1.5sq. mm + 1 X 1.5 sq. mm earth wire 13 same as above but for 2X 2.5sq. mm + 1 X 2.5 sq. mm earth wire 14 same as above but for 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 15 same as above but for 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 16 same as above but for 2X10 sq. mm + 1X6 sq. mm earth wire 17 same as above but for 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 18 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 19 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 20 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 21 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 22 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 23 Supplying & fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 24 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 25 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 26 Supplying and fixing call bell/ buzzer suitable for single phase, V, complete as required. 27 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door 28 same as above but for 12 way , Double door 29 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door 30 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4way (4 + 12), Double door 31 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 32 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 33 S&F of 40 Amp. SP MCB (10 KA)Cat A 34 S&F of 40 Amp. DP MCB (10 KA)Cat A 35 S&F of 63Amp. SP MCB (10 KA)Cat A 36 S&F of 63Amp. DP MCB (10 KA)Cat A 37 S&F of 63Amp. TP MCB (10 KA) C Curve Cat A 38 S&F of 63 Amp. 4 pole MCB(10 KA)C Curve Cat A 39 S&F of 80to 100 Amp4 pole MCCB (16 KA)Thermal Magnetic release Cat A 40 S&F of 160Amp4 pole MCCB (16 KA)Thermal Magnetic release 41 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 42 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 43 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 44 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 45 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm) 46 same as above but for 4 X 16 sq. mm (28mm) 47 same as above but for 3.5 X 70 sq. mm (38mm) 48 same as above but for 185 Sqmmx3.5 core 49 SupplyandlayingofaluminiumconductorPVCinsulatedarmouredservedsheathedcables1100Volts gradeon wall/surface the cable run shall be fixedon M.S. clamps etc. of suitable size or asdirectedbytheEngineer-Incharge, completeinall respect.Thearmouringofthecableshallbeproperly connected with the earth conductor by clamps etc.10 sq. mmX 2 Core 50 same as above but for 16 sq. mmX4 Core 51 same as above but for 70 sq. mmX3.5 Core 52 same as above but for 185 sq. mm 3-1/2 core 53 Supply, Installation, Testing and Commissioning of LT Panel vermin proof floor mounting , M.S. channelbase with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided a accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA C Curve. Cubicle type switch board shall be Cat-A and B only. Incoming 400 Amp MCCB -1 No& outgoing 200 A MCCB-1 no., 100 A MCCB-2 nos. & 63 A MCCB-1 no. 54 Supply and fixing of 18-22W LED Batten fitting with Extruded Aiuninumn housing, special polycarbenate difluser for glare free light distnbution and suitable mounting for on both surface & suspended. Compelete in all respect. 1980-2420 syslem lumens, >110 Lm/W, PF>0.95, THD<10%, CRI >80, with 3 year warranty. 55 Supply and fixing of LED Tube Light with heavy duty Metal Box type batten Light fitting 2x22 watt suitable for upto 2x22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended Complete in all respect. 2x2640 sy stem lumens, >120 Lm/W, PF>0.95, THD<10%, CRI >80, sheet thickness min. 0.8mm, Tube with aluminium heat sink. >300V over voltage protection, 2.5 KV internal Surge Protection, with 5 year warrantee CAT-AAA 56 S/f of IP 20, Front Lit, Mid Power SMD type LED light, recessSurface mounting round 10 Watt to 15 Watt , Cut out Min 125 mm, Height Min 40 mm,, LED Down Lighter having Powder coated die cast aluminiun housing with heat sink, High purity transmisivity UV Stabilized Non yellowish diffuser Reflector for unifom light distribution, detachable driver set, stable for 24 Hr Continous Operation, Complete in All respect 1100-1650 system lumen, >110 Lm/W, PF>0.95, THD <10% at full loàd, CRI >80, with 3 years warranty. 57 S/F of Water tight oblong 10wLED Bulk Head luminaire havingDie cast Alluminium housingwithdriver set confirming to IP 65 and above protection ,suitable for 24 Hrs. Continuous operation,complete in all respect.1100 system lumens, 110 Lm/W. PF>0.95, CRI>70, with 3 year warranty.Cat AA 58 Supply and fixing of LED Street light Fitting withmandatory driver set having die cast aluminium body with toughend glass/ UV stabilized PC Cover and lenses suitablefor 75 Watt. to 90 Watt and Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respect including Labour.9000-10800 system lumens, High Power LED with lenses,120 Lm/W, PF>0.95, THD <10% at full load, CRI >70,,Potted driver Set in Metal housing (Not Circuitory) Phase to phase Protection at 440V & >300V auto cut and re-startfeature, with 5 years warrantee. 59 S/F of LED Bulb 12 Watt 60 Supply of Fresh Air Fan300 mm Sweep metalic Complete in all respect. 61 Supply of Heavy duty Exhaust fan 300 mm sweep 900/1400 RPM 62 S&Fof200Amp.fourpolechangeoverswitchon50mmx 50mmx6mmangleironframe,includingthecostoflabour, T&P,paintingandothermaterialrequiredforproper completionoftheworkasperdirectionandsatisfactionofEngineer in charge. 63 S/F of Rubber matting1800x900x12 mm tested and chequred 64 Supplyandfixingoffireextinguisher,ABCType4.00 kg.capacity(ISIMarkedIS: 15683& TACapproved) complete with initial charge and wall bracket, along with supply of all materials andlabour for proper completion of work. 65 Supply andfixingofC02typefireextinguisher4.5kg. capacity (ISIMarkedIS:2878&TACapproved) complete with initial charge and wall bracket, along with supply of all materials andlabour for proper completionof work.

Key Value

Document Fees
INR 854 /-
EMD
INR 173000.0 /-
Tender Value
INR 17.24 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail