| 1 | Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holder etc by unscrewing from board carefully and keep aside for schedule of credit to contactor including making good of the disturbed surfaces, all as specified and directed. |
| 2 | Taking down only old u/s items such as normal/modular tupe switches, Bell push, call bell, ceiling rose, sockets, switch sockets, regulator, lamp holderetc by unscrewing from board carefullyincluding making good of the disturbed surfaces, all as specified and directed. |
| 3 | Material and labour for point wiring (surface type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC casing-N- caping (medium duty) double lock type,size of casing caping as required at site but not less than 20mm with fittings and accessories pressed steel sunken terminal box in concealedmade out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick bakelite sheet cover for fixing switches, sockets, regulator etc and earth continuty conductor shall be connected to common earth and earth dolly for one light/fan/call bell point controlled by one way switch complete all as specified and as directed.Note for item Nos.3 to 6: (i)Cost of cutting of wall, if any, for housing of metal box and also making good the disturbed surfaces are deemed to be included in unit rate(ii) Wire should be used in proper colour code red/yellow/blue for phase, black for neutral & green for earth |
| 4 | Ditto- all as per item No 03 here in above but for One 3/5pin 6Amp Socket outlet on the same board with other switches complete all as specified and as directed. |
| 5 | Ditto- all as per item No 03 here in above but for One 3/5pin 6Amp Socket outlet on the independent board complete all as specified and as directed. |
| 6 | Ditto- all as per item No 03 here in above but with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 2.5 sqmm (nominal area) for phase,neutral & earthfor One 3/5pin 16Amp Socket outlet on the independent board complete all as specified and as directed. |
| 7 | Material and labour for point wiring (concealed type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate sizeand accessories pressed steel sunken terminal box in concealedmade out of 1.6 mm thick MS sheet duly painted with two coats of synthetic enamel paint of approved colour over a coat of red oxide zinc chrome primer and covered with 3 mm thick bakelite sheet cover for fixing switches, sockets, regulator etc and earth continuty conductor shall be connected to common earth and earth dolly for one light/fan point controlled by one way switch complete all as specified and as directed. Note for item Nos.7 to 8: (i)Cost of cutting of wall, if any, for housing of metal box and also making good the disturbed surfaces are deemed to be included in unit rate.(ii)Cost of chase cuttingforconduit wiring shall be to be included in unit rate.(iii) Wire should be used in proper colour code red /yellow/blue/black |
| 8 | Ditto- all as per item No 07 here in above but with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 2.5 sqmm (nominal area) for phase,neutral & earthfor One 5pin 16Amp Socket outlet on the independent board complete all as specified and as directed. |
| 9 | Supply and fix switch piano flush button 6 Amp single pole, one way complete all as specified and as directed . |
| 10 | Supply and fix socket out let 5 Pin, 6 Amps flush typecomplete all as specified and as directed. |
| 11 | Supply and fixSwitch socket combination5 Pin, 6 Amp flush type complete all as specified and as directed.. |
| 12 | Supply and fix switch socket combination 5 Pin 6/16 Amp flush type with complete all as specified and as directed. |
| 13 | Supply and fix ceiling rose surface bakelite, 65 x 50mm, three terminals all as directed. |
| 14 | Supply and fix bell push, flush type 6 Amps complete all as specified and as directed. |
| 15 | Supply and fix electronic fan regulator stepped (5 step) rotary socket type flush type AC 240 voltcomplete all as specified and as directed.. |
| 16 | Supply and fix call bell Ding Dong, AC, 230V single pole all as specifiedas directed. |
| 17 | Material and labour for sub main wiringwith two single core PVC insulated cable with Copper conducter unsheathed cable (FRLS) of size 6.0 sqmm drawn through & including PVC conduit with 6.0 sqmm PVC insulated copper wire single core for continuous earthing after taking out old unservicable submain wiring complete all as directed. |
| 18 | All as per item No 17 here in above but with Copper conducter unsheathed cable (FRLS) of size 4.0 sqmm complete all as directed. |
| 19 | Supply and fix in replacement powder coated sheet metal enclosure (in concealed) single pole & neutral for DBs (Double door)4 way with 200 amps rated busbar DIN channel, neutral link & earth link superlineall as specified as directed.(Chase cutting & make good disturb surface is included in unit rate). |
| 20 | All as per item No 19 here in above but for 8 way SPN DB. |
| 21 | All as per item No 19 here in above but for 12 way SPN DB. |
| 22 | Supply andfix MCB single pole6 to 32 amps, 240 volts, 10 KA, \"C\" series with all incoming / outgoing connections with proper size of lugs complete inculdingtaking down the old unserviceable one all as specified as directed. |
| 23 | Supply andfix MCB single pole & neutral 6 to 32 amps, 240 volts, 10 KA, \"C\" series with all incoming / outgoing connections with proper size of lugs complete inculdingtaking down the old unserviceable one all as specified as directed |
| 24 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver and integrated tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Including taking down old unserceable light fittingcomplete all as specified and as directed. |
| 25 | Supply and fixing LED light fitting 2 feet, 10 watt 220 V AC decorative type with driver integrated tube light connecting including connecting up with three core flexible copper conductor cable of suitable size complete ncluding taking down old unserceable light fitting complete all as specified and as directed. |
| 26 | Supply and fix Modular switch 1 way 6A, 1 module complete all as specified and as directed. |
| 27 | Supply and fix modular Socket, 6A -3 pin combined 2 module, complete all as specified and as directed. |
| 28 | Supply and fixr for modular type Fan step regulator, 120W - 2 modulecomplete all as specified and as directed. |
| 29 | Supply and fixing sub-main wiring with PVC conduit insulated & unsheathed 4 run of 10 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade along with two run of 10 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade connected to common earth dolly as earth continuity conductor drawn through steel conduit after and including taking down existing sub main wiring complete all as specified and as directed Note (i) 6 run of 10 Sqmm cable andone run of conduit shall be measured as one unit. Note : (ii) Wire should be used in proper colour code red/yellow/blue for phase, black for neutral & green for earth |
| 30 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete including taking down old unserceable light fitting all as specified and directed. |
| 31 | Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100mm C/C both way and two Nos lifting handle made of 12mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete all as specified in electrical plate No 3 of SSR Part-I including taking down old earthing. |
| 32 | Supply and fix lamp holder insulatedbodywith back plate suitable for batten fittings complete all as specified & directed. |
| 33 | S & F for sheet metal enclosure single pole and neutral with two pin and earth plug & top complete with one single pole MCB 20 Amps 240 volt including taking down old one all as specified as directed. |
| 34 | Supply and fix sheet metal enclosure /TPNDBs (Double door) 4 way with 200 amps rated busbar suitable for MCB including taking down old unserviceable enclosure one complete all as specified as directed. |
| 35 | Supply andfix MCB triple pole & neutral 63 amps, 240 volts, 10 KA, \"C\" series with all incoming / outgoing connections suitablefor4 waytype TPN DB in double door with proper size of aluminium lugs completeall as specified as directed. |
| 36 | Supply and fix in replacementof 4 way vertical type TPN DB in double door suitable for four pole MCCB (63A/100 A)as incomer including make good of damaged surface/wall including re-connection with existing earth wire to DB all as specified and as directed.Note:- MCCB shall be measured and paid seperatly. |
| 37 | Supply andfix in replacementMCCB triple pole & neutral 63 amps,,16 KA,with all incoming / outgoing connections suitablefor fix 4 way vertical type TPN DB in double door twith proper size of aluminium lugs complete all as specified as directed. |
| 38 | Supply and fix LED lamp (B22 Base type) of 1x9 W after taking down the old unserviceable CFL/GLS lamp complete all as specified and as directed. |
| 39 | Supply and fix LED light fitting, 1x10/12w bulk head luminaries, with LED lamp, etc. complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size, including taking down the old unserviceable fitting complete all as specified and directed. |
| 40 | NOTES :-1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2.Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule \"A\" notes for details. |