| 1 | Taking out/ cleaning/ sludge/mud/silt from manhole, septic tanks of any size and capacity manual or mechanically including dewatering septic tank and manholes when ever required including removing of sludge/mud/siltin a closed container vehicle to a distance outside MD land and buried in pits by making necessary excavation for filling of sludge and covering by earth on top properly complete all as specified and directed. |
| 2 | Taking out muddy/ sewage water from soakage well/ soakage pit by using of mechanical sewage/ mud water diesel pump set of 5 HP power and disposed off it through delivery pipe of required size more than 50m away from soakage pit/ soak well complete all as specified and directed . Notes for item No 1 & 2 :- (a)Sludge/mud/silt shall be measured before taking out from manholes/septic tank.(b)All labour and T&P i.e. mechnical sewage/mud water pump set, diesel, transportation of pump set from one place to other place, suction pipe, delivery pipe and manpower etc required for above work, shall be deemed included in unit rates quoted by the contractor and nothing extra shall be admissible on this account.(c) The contractor shall provide suffecient labourers (minimum 1 highly skilled &3 skilled labour at the daily basis) for the above works and they shall report daily to AGE B/R jassai, in the morning at 09:00 AM and in the evening at 05:00 PM. (d)Based on complaint received daily, complaint slip will be issued to the contractor accordingly. After completing the complaint, user\"s signature shall be obtained in complaint slip by the contractor and handed over to the complaint cell, AGE B/R Jasai (concerned JE).(e) If a labour and supervisor / contractor does not comply with the orders of concerned JE and Engg-in-charge, the contractor shall be responsible for such carelessness, as well as on the basis complaint of the concerned JE/AGE, the penalty will be recovered from the contractor bills for the irresponsibility of which to recover rate will be determined by Accepting officer. |
| 3 | Removing of blockage from WC/floor trap/Nahani trap and line up to 1st manholes by opening grating and refixing after removing all greese, muds,sludge,silts etc complete all as specified and directed.Notes for item No 3(a) The contractor shall provide minimum 2 labourers (safaiwala) (minimum 1 highly skilled &others skilled labours for day to day complain) for the above works and they shall report daily to AGE B/R jassai, in the morning at 09:00 AM and in the evening at 05:00 PM. (b)Based on complaint received daily, complaint slip will be issued to the contractor accordingly. After completing the complaint, user\"s signature shall be obtained in complaint slip by the contractor and handed over to the complaint cell, AGE B/R Jasai (concerned JE).(c) If a labour and supervisor / contractor does not comply with the orders of concerned JE and Engg-in-charge and does not attend the office/absent, the contractor shall be responsible for such carelessness, as well as on the basis complaint of the concerned JE/AGE, the penalty will be recovered @ 2000/day from the contractor bills for the irresponsibility. |
| 4 | Cleaning of sewage pipe line of 100 mm dia by roding from manhole to manhole and flushing with water, after cleaning and refixing the man hole cover complete all as specified and directed. |
| 5 | Cleaning of sewage pipe line of 150 mm dia by roding from manhole to manhole and flushing with water, after cleaning and refixing the man hole cover complete all as specified and directed. |
| 6 | Cleaning of sewage pipe line of 200 mm dia by roding from manhole to manhole and flushing with water, after cleaning and refixing the man hole cover complete all as specified and directed. |
| 7 | Excavation in trenches notexceeding 1.5m wide and not exceeding 1.5m in depth,for foundation,laying of sewar line etc.,and getting out in any type of soil complete all as specified and directed. |
| 8 | Excavation over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed |
| 9 | Excavation over areas,exc 1.5 m and n exc 3 m depth and getting out in any type of soil complete all as specified and directed |
| 10 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of any dia, set in cement mortar including PCC in bed and haunching against side including removing debris and rubbish outside MD landcomplete all as specified and as d |
| 11 | S & F 150 mm bore Reinforced cement concrete pipes, with collars, class NP2, laid in trenches and jointed complete all as specified and as directed . |
| 12 | M & L Salt for glazed stone ware (SGSW) drain pipes 100 mm internal dia laid in trenches on concrete bed and jointed, complete all as specified. |
| 13 | M&LPCC 1:4:8 type D-2 by using 40 mm graded crused stone aggregate as in bed to 150 mm bore salt glazed stone ware drainpipeor reinforced concrete drain pipes, includingpacking under and haunching against the side ofpipe after they are laid and tested complete all as specified and as directed . |
| 14 | M&LPCC 1:4:8 type D-2 by using 40 mm graded crused stone aggregate as in bed to 100 mm bore salt glazed stone ware drainpipeor reinforced concrete drain pipes, includingpacking under and haunching against the side ofpipe after they are laid and tested complete all as specified and as directed . |
| 15 | Returning, filling in, including spreading, leveling, watering and well ramming inlayer not exceeding 25cm thick in any type ofsoil complete all as specified and as directed . |
| 16 | Removal of excavated soil to a distance not exceeding 50 mtr and depositing where directed at a levelnot exceeding 1.5 mtr above the starting point complete all as specified and as directed . |
| 17 | Demolition of stone / boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed. |
| 18 | M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM (1:6) complete all as specified as directed. |
| 19 | M&L Walling of random rubble masonary well bonded,bedded and solidly hearted built in cement mortar 1:4 brought up to courses except stone complete all as specified and directed |
| 20 | M&L for precast-cement concrete block masonary with solid blocks type D-1 ,1:3:6 (20mm graded aggregates) exc 10 cm in width and setting in CM 1:6 ,complete all as specified and directed |
| 21 | M&L for Walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed |
| 22 | Extra over stone walling for hammer dressing to face granite or trap stones with maximum depression on face from a straight edge held against the dressed surface not exceeding 20mm and dressing face beds and joints as specified of random rubble walling un |
| 23 | Taking down cement plaster any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 24 | M&L for 10mm thick rendering on wall surface, in CM 1;4 On concrete surface finish even and smooth without using extra cement complete all as specified and directed Note:- WPC will be measured and paid separately |
| 25 | M&L rendering 15mm thick in CM 1:6on stone masonry surfaces, finished even and fair without using extra cement mixed with water proofing compound as per manufacturer instructionscomplete all as specified and directed. Note :- WPC will be measured and paid seperately. |
| 26 | M&L for preparation of new plastered surfaces of walls and applying two coat of cement based paint over a coat of primer complete all as specified and directed. |
| 27 | Supply onlyliquidwater proofing compound ( For external new plaster surfaces) |
| 28 | S & F in repairs vitreous china wash down water closet pan [Pedestal pattern], white [excluding flushing cistern and flush pipe] including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium |
| 29 | S & F in repairs white vitreous china squatting pan \"Orissa pattern\" of size 580 mm X 440 mmwith integral foot rests and PVC \"P\" or \"S\" trap includingprovision of cement concrete bedding 1:5:10 type E2 complete all as specified and as directed. |
| 30 | S&F in repair 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on trenches or in floors /wall complete all as specified and as directed. |
| 31 | S&F in repair 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid ontrenches or in floors/wall complete all as specified and as directed. |
| 32 | S & F in repair of stack clamps made out of 50 X 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110mm bore pipescomplete all as specified and as directed. |
| 33 | S & F in repair of110 mm bore PVC [SWR] vent cowl complete all as specified and as directed. |
| 34 | S&F PVC (SWR) bend any radius 110mmcomplete all as specified and directed. |
| 35 | S&F PVC (SWR) bend any radius 75mm complete all as specified and directed. |
| 36 | S&F in repairs 110 mm bore PVC [SWR] Junction single [single \"T\" or \"Y\"] equal or unequal, completeall as specified and as directed. |
| 37 | S&F in repairs 75 mm bore PVC [SWR] Junction single [single \"T\" or \"Y\"] equal or unequal, complete all as specified and as directed. |
| 38 | S&F in repairs 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 39 | S&F in repairs Stainless steel gratings 100mm bore size fixed with cement motar. |
| 40 | Demolition of reinforced cement concrete on roofs,floors ( other than ground floors), beams,staircase,landing, chajjas and similar suspended work complete all as specified and directed |
| 41 | M&L Nominal mixreinforced cement concrete type B1 (1:2:4) using 20 mm graeded stone aggregate as in roof slabs supported on walls surfaces of concrete flat all as specified. |
| 42 | M&L form work to soffits of suspended slabs such as roof slab landings and similar works n exc 100mm thick (horizontal or slopping) fair finished surfaces of concrete flat all as specified |
| 43 | M&L form work to edges of concrete flates ,treads break in floors ,window cills ,concrete railings , openings in concrete walls, floor and roofs n exc 20 cm wide and sisides of RCC/PCC bands in walls, horizontal or sloping and ssimilar work exc 10 cm but n. exc 20 cm wideroughfinished surface of concrete |
| 44 | M&L for RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in precast manhole/drain covers including demolition of RCC slab, manhole/drain cover in any position complete all as specified and as directed. |
| 45 | M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified (GRADE FE-410-W,Gde.E-250 quality-A ) |
| 46 | Dismantling of posts or struts (wood, steel or RCC) any section embadded in concrete, including taking out embedded portion and making good disturbed ground complete all as specified and as directed. |
| 47 | Dismantling fencing wire mesh, any type complete all as specified and as directed. |
| 48 | Supply only chain link MS galvanized fencingsize or type all as specified by Engr-in-charge. |
| 49 | Fixing only chain link fencing including line wires any mesh size and type of standard rails complete all as specified and as directed. |
| 50 | S&F Mild steel in flat, round or square bars, in available lengths, Fe 290 (Gde E-165) complete all as specified and as directed. |
| 51 | M&L mild steel screw bolts (machine Made) with hexagonal or square heads at one end and screwed the other to be fitted with washer and one hexagonal or square nut exc 15cm and n exc 22.5cm long, dia of neck 11-15 mm complete all as specified and as directed. |
| 52 | S & F mild steel work as in angle iron , Tee etc as in posts & strut in fencing including cutting tops to shape, drilling holes notching for wire etc flat iron fillets for securing wire mess etc including all necessary drilling, bolting or riveting etc and similar works conforming to Fe-410-0 or Fe-310-0 (Make Tara or equivilant) |
| 53 | Excavation in post holes in any type of soil, n exc 0.50 cum in each post, getting out returning, filling in and ramming earth or broken rubble mix with earth around in layers n exc 25 cm watering and removing surplus soil to a distance n exc 50 M and making good surface and all as specified. |
| 54 | M & L cement concrete 1:4:8 of type D2 (using 40mm graded stone aggregate) incl demolition as in filling and mass concrete |
| 55 | M&L PCC (1:2:4) type B-1 (using 20mm graded stone aggregates) as in coping,benching/ channels ofmanholes including demolition of existing pcc etc complete all as specified and directed |
| 56 | M&L for Cement concrete Type B0 1:2:4 (12.5 mm graded aggregate) in surface channels and drains incl demolition complete all as specified and as directed. |
| 57 | Dismantling structural steel work including doors, gates but excluding framed trusses complete all as specified and as directed. |
| 58 | S&F framed work as in gate etc of angle,tubularor other section with gusset plates, braces etc complete drilled for fixing of steel sheeting or other covering prepared for hanging or sliding with and including either hooks & hinges for steel hanging door fitings complete all as specified and as directed. |
| 59 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces including prepration of new steel surfaces of any description over 10cm girth or width complete all as specified and as directed. |
| 60 | M&L non skid ceramic tiles, white, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to matchwith the colour of tiles including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 complete and including demolition of tiles completeall as specified and as directed. |
| 61 | S&F Non-Skid ceramic Coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 15mm thick screed bed in CM 1:4 including demolition of tiles. complete all as specified. |
| 62 | M&L for 300mmx300mmx10mm thick non skid polka dots parking floor paver tiles with grey cementandpigment, over and including 15mm thick screed in CM (1:4), set jointed & pointed in neat cement slurry in floors including demolition of tiles complete all as specified and directed. |
| 63 | M&L 80 mm thickness machine pressed rubber moulded precast interlocking paver block anyshape and size conforming to IS - 15658-2006 ofM-40 grade with grey cement and no pigment complete all as specified and directed |
| 64 | M&L for 60mm thickness machine pressed rubber moulded precast interlocking paver block anyshape and size conforming to IS - 15658-2006 ofM-40 grade with grey cement and no pigment complete all as specified and directed |
| 65 | M&L for sand filling25mm thick under floors or in foundations inc. watering and consolidation |
| 66 | Demolition of stone slabs, paving stones and tiles of any description and thickness in floors, aprons, laid, bedded and pointed in any mortar complete all as specified and as directed. |
| 67 | M&L 100mm thick cement concrete type D-2, 1:4:8 (40mm graded crushed stone aggregate) finishing cement concrete surface even and smooth without using extra cement as specified and directed. |
| 68 | Demolition of concrete in ground floors and paving n exc 15cm thickness (below or above ground level ) complete all as specified and directed |
| 69 | Demolition for ( Rcc jali)ashlar facings,dressed stonework,precast concrete articles and precast concrete block walling complete all as specified and directed |
| 70 | M&L for providing precast cement concrete louvres and jallies incl pillars of type B0 1:2:4 (12.5MM GRADED AGGREGATE) set in cement mortar 1:4, of40mm thick (measured solid), including all mould-ings but excluding frame (pre castframe shall be measured separately and paid for under item 4032) complete all as specified and directed |
| 71 | S&F in repair galvanized 2 strand steel barbed wire 2.00mm dia barbed with 2mm dia barbs at 75mm spacing & straining & fixing to any type of standards rails straining bolts including securing or tying at crossing with & provn of galvanized mild steel wire complete all as specified and as directed. |
| 72 | Cleaning of SWT by manually/pumping out water sludge mud with suction pumps including one coat of white washing,sprinkling of antibiotic powder etc and disposemud/ sludge out side MD land complete all as directed and as specified.Note:- 1. Rate quoted is deemed to include the cost of all safty/ protective gears required for workers employed by contracor.2.Payment shall be made based on stacked measurement of debries removed from SWT etc. |
| 73 | S&F in repair for stainless steel letters (any from A to Z) 300 mm height, 25mm width and 25 mm depth made of 0.79 mm thick (22 gauge) stainless sheet304 grade with seemless welding rubbed polished (Golden/Silver/Rose Gold) and edges made smooth with necessary fixing devices like SS screws or as per manufacturer\"s instructions to fixed on ACP sheet, wall or stone complete all as specified and directed by Engr in Charge. |