Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | INDOOR SPORT\"S COMPLEX |
| 2 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 3 | Cement concrete 1:6:12 With brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type 10.8 a ii |
| 4 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (10.16) |
| 5 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 6 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 i) |
| 7 | ReinforcedcementconcreteM-25mechanicalybatchmixedusingbatch typeconcretemixerasperIS:1791andvibratedbyneedlevibratorbut excluding steel reinforcement centring and shuttering in supersturcture. (10.21) |
| 8 | Extra Rate for First Floor |
| 9 | Extra Rate for Second Floor |
| 10 | Centring and shuttering for Columns ( Square or Rectangular or plygonal in plain) in superstructure |
| 11 | Extra Rate for First Floor |
| 12 | Extra Rate for Second Floor |
| 13 | Centringand shutteringfor sidesand soffitsof beam,beams launchingsgirders bressumers, lintels |
| 14 | Extra Rate for First Floor |
| 15 | Extra Rate for Second Floor |
| 16 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 17 | Extra Rate for First Floor |
| 18 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 19 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 20 | Extra Rate for First Floor |
| 21 | Extra Rate for Second Floor |
| 22 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. (11.6) |
| 23 | Extra rate for First Floor |
| 24 | Extra rate for Second Floor |
| 25 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement sand mortar in super structure. |
| 26 | Damp proof course 4cm thick of cement concrete 1:2:4 with water proofing compound as per manufactures guidelines. (10.27) |
| 27 | 12.5 mm thick cement plaster 1:5 (15.10) |
| 28 | Extra Rate for First Floor |
| 29 | Extra Rate for Second Floor |
| 30 | 20mm thick cement plaster 1:5 in two coat work (15.21) |
| 31 | Extra Rate for First Floor |
| 32 | Extra Rate for Second Floor |
| 33 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. |
| 34 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735includingjointingcompleteasperspecificationsandtothe entire satisfaction of Engineer- in- charge. UPVC 110 mm bend |
| 35 | Providingand fixing110 mmdia SWRU.P.V.C Coupling/Socketefor Rain water pipe as per IS:14735including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 36 | Topkhurra0.6mx0.6mforrainwaterpipein25mmthickcement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (13.45) |
| 37 | Providing and fixing in position gratings 150mmx150mm for gully trap. PVC grating |
| 38 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. (13.51) |
| 39 | Terracingconsitingoftiles22.86x11.43x3.83cmlaidover25mmmud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing (13.13 (i)) |
| 40 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (13.55) |
| 41 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 42 | Earth filling under floors with surplus ordinary soil or soil containing gravel orkankarupto 40%excavatedfromfoundationandtakenonlyfrom outsidethebuildingplinthin15cmlayersincludingramming,watering and consolidating lead upto 30 metres. |
| 43 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material(14.3) |
| 44 | Screedof50mmthickcementconcrete1:8:16withstoneaggregate 40mmgaugetobelaidbelowthetoppingusingmechanicalmixerfor mixing of material(14.11) |
| 45 | Extra Rate for First Floor |
| 46 | Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles ofthickness 12mm to 15mm Slabs sizes above 0.50 sqm(14.74 (iv) (b)) |
| 47 | Extra Rate for First Floor |
| 48 | Providing and laying vitrified floor tiles in different size in light colour shades made using Full Body Technology (thickness to specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement :4 fine sand ), complete. (Full body vitirified tiles have pigment in entire body/ thickness of which make chips and scratches less noticeable and na ideal choice for high traffic zones)Size 600x600 mm CSR 14.115 a |
| 49 | Extra Rate for First Floor |
| 50 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm. |
| 51 | Kota stone slab 20-25 mm thickflooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :(14.84) |
| 52 | Extra Rate for First Floor |
| 53 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing(14.86) |
| 54 | Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness and colouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects. (14.142) |
| 55 | Providing and laying Polished Granite stone 18 mm thickflooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.(14.89 b) |
| 56 | Providing and laying Laminate wooden flooring (Grade AC4 or AC4+ laminates) 6 mm to 12 mm thick, having a good backing layer made up of plastic laminate or melamine, core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminum oxide finish that protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer. |
| 57 | Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.) |
| 58 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge.(14.135) |
| 59 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : |
| 60 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.( 620+20%) |
| 61 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)Float glass panes of 5 mm thickness |
| 62 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm 5.0mm thick Plate glass (INDIAN) |
| 63 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 64 | Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop .. |
| 65 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.(755+20%) |
| 66 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position(18.4) |
| 67 | Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer\"s specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge. |
| 68 | Providing & fixing 30mm thickFactory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steelprimers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC \"C\" Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent cement adhesive etc. complete as per manufacturer\"s specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge. |
| 69 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 70 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 71 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm |
| 72 | Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects. |
| 73 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 74 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 75 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 76 | Finishing walls with Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 77 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti ncluding finishing the surface to required finish complete. |
| 78 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 79 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 80 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 81 | Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge) The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metallic coated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.60 mm (+ 0.05 %) thick(712+30%) |
| 82 | Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:-Above 15.00 mt. Span including the cost for machinery i.e. Hydra cranes etc. for hoisting in position. |
| 83 | Providing and Fixing multilayer Polyuerthane flooring (10+2mm) consisting of primer on asphault surface, elastic layer SBR matt (5-12mm), Pore sealer(0.1mm), Cast coating (2-3mm), Antiskid multitop (0.5mm) incliding making of Ground Approvedby ITF on already laid Flooring System complete in all respect |
| 84 | Providing and instalation ofintegrally weighted movable Badminton Posts. The badminton posts shall allows regulation net height to be achieved detachable front upright. It shall be manufacture from 47x47mm square pipe 4mm thick. Base shall made up of strong pipe and shall have weight stock of cast/mild steel 70kg each side. Wheels shall non marking with bearing inside and the wheel shall have 100 mm dia. Complete with rubber feet to protect the playing surface and grip on wooden& synthetic floor. The poles shall either powder coated or spray painted.The net shall made up of nylon material ,suitable for all weather use.The four sides of net shall be covered with white waterproof vinyl tapes. |
| 85 | Supply ofset of Moveble Basket Ball Poles having minimum weight 600kg on each side of pole and having adjustable height extension. Each Pole shall consist of Fibre board of size 1.05x1.8mtr and 25mm thick and shall consist of 2 nos dunking rings with net as per Standard Design |
| 86 | Providing and Fixing of Turbo Fan /Non Electric Exhaust Fan 21\"/22\" dia to be fitted on roof top/shed etc. with imported polycarbonate body base complete in all respects upto to the entire satisfaction of the Engineer-In-Charge of the work |
| 87 | Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.)in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 88 | Construction ofPlinth protection complete |
| 89 | Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layerswithcompactionincludingdisposalofallsurplussoilas directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing andto theentire satisfication of Engineer In-Charge. |
| 90 | CementConcrete1:8:16with40mmguagestoneaggregateusing mechanical mixer.(10.6 b ii) |
| 91 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (11.3 (i)) |
| 92 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material(14.3) |
| 93 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).(14.6) |
| 94 | 12.5mmthickcementplaster1:5 completeinallrespectas perspecifcation,drawingand tothe entiresatisficationof Engineer-In-Charge.(15.10) |
| 95 | 400 mtr Synthetic Track |
| 96 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 97 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, as required for IAAF approved Track With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 - (150mm thick layer) |
| 98 | (A) MATERIAL Providing, laying, spreading and compacting stone aggregates of Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant , to site of work , laying in uniform layers with paver in sub base / base course on well prepared surface andcompacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specification. CSR 24.13 |
| 99 | Providing and applying primer coat with bitumen emulsion SS on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.85kg/sqm complete as per technical clause 502 of MORT&H specifications |
| 100 | Providing and laying dense graded bituminous macadam 50mm to 75mm thick with Continuous type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 4.5%, laying with a Paver Finisher Mechanical to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete as per technical clause 505 of MORT&H specifications 24.20 b |
| 101 | Tack Coat @ 0.40kg per sqmProviding and applying tack coat with penetration grade bitumen VG-10 using bitumen pressure distributor at the rate of 0.40 kg per sqm on the prepared bituminous surface/granular surfacetreated with prime coat after cleaning the surface complete as per technical specifications24.16 b |
| 102 | Providing and layingbituminous concreteon the prepared surface with specified graded crushed stone aggregate for wearing course including loading of aggregate with FE loader and hot mixing of stone aggregate, filler and bitumen in hot mix plant, transporting the mixed material by tipper to paver and laying the mixed materialwith paver finisher fitted with electronic sensing deviceto the required level and grade and rolling by road roller as per IAAF Approved track specifications, to achieve the desired density, but excluding the cost of primer / tack coat. 30 mm compacted thickness with bitumen of grade VG-30 @ 5.4% and lime@ 2% (percentage by weight of total mix) |
| 103 | Precast Cement Concrete Kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 104 | Providing and laying Synthetic Athletic Track of FULL PUR with FULL EPDM System having a minimum thickness of 15mm with valid product approval certificate and laboratory test certificates from World Athletics (IAAF) for minimum 15mm thickness, including markings on the surface all complete as per requirements/ specifications laid down by World Athletics (IAAF) and Class-I certification. The agency should have supplied and installed at least 5 World Athletics (Earlier IAAF) Certified class 2 facility track Cast in situ in the last 5 years, out of which one should be Full PUR Full EPDM with the same proposed product/brand including complete sub base in India from the last day of previous month from tender floatation in their individual capacity and not as a Joint Venture. The proposed product should be certified by World Athletic (Earlier IAAF) for a minimum thickness of 15MM for Class I Track. The proposed product/brand should be of European/American/Australian origin only. |
| 105 | Supply and fixing of Track field equipment: As per IAAF approved. Long jump/ triple jump Take off board- As per IAAF approved |
| 106 | Construction of sand filling Jumping pit for long jump/ triple jump. As per IAAF approved. |
| 107 | Construction of steeple chase water jump pit at inside the North D portion . As per IAAF approved. |
| 108 | Pole -vault box with cover |
| 109 | Shotput throwing circle of dia 2.135m |
| 110 | Stop board for shotput circle |
| 111 | Discuss throwing circle of dia 2.50m |
| 112 | Hammer throwing circle of dia 2.50m |
| 113 | Hammer throwing cage incl. Poles and net. |
| 114 | Discuss throwing cage incl. Poles and net. |
| 115 | Aluminium kerbing-400m standard track |
| 116 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cuttingin streets or open areaincluding trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.Earth work upto 1.5 m. Depth for Ordinary soil having gravel upto 40% |
| 117 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, C57testing for water tightness and making good the leakages and defectsincluding cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.200 mm o/d pipes |
| 118 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.dia 75mm o/d pipe of 10 Kgf. / sqcm |
| 119 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 90x150 cm and 120 cm deep |
| 120 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type. |
| 121 | First class burnt brick work laid in cement sand mortar 1:4 in foundation & Plinth. |
| 122 | 12.5mm thick cement plaster 1:4. |
| 123 | Reinforced cement cocrete M-25 Mechnicaly batch mixed using batch type concrete mixer as per IS: 1791 and vibrator by needle vibrator but excluding steelreinforcement, centering and shuttering in foundation and plinth. |
| 124 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc when curved. |
| 125 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 126 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer -in-charge. |
| 127 | OUTER STRUCTURE |
| 128 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 129 | CementConcrete1:8:16with40mmguagestoneaggregateusing mechanical mixer.(10.6 b ii) |
| 130 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 131 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (10.15) |
| 132 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 133 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.(10.20) |
| 134 | Centring and shuttering for Columns ( Square or Rectangular or plygonal in plain) in superstructure |
| 135 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 18.18 |
| 136 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.11.6 |
| 137 | 12.5mm thick cement plaster 1:5.(15.10) |
| 138 | 20 mm thick cement plaster 1:5 in two coats work.(15.21) |
| 139 | PARKING |
| 140 | Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications |
| 141 | Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications (CSR 24.7) |
| 142 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant,laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications CSR 24.13 |
| 143 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Non traffic Areas and streets having width less than 3.05 mt.( Also not to used over footoaths). |
| 144 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. |
| 145 | Precast Cement Concrete Kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 146 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 147 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over an including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 148 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 149 | Applying priming coat with metal primer onnew steel or iron work including preparation ofsurface. |
| 150 | Iron grated doors, including pintle hinges & arrangements. |
| 151 | LIFT |
| 152 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 153 | Cement concrete 1:6:12 With brick ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type 10.8 a ii |
| 154 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (10.16) |
| 155 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. |
| 156 | ReinforcedcementconcreteM-25mechanicalybatchmixedusingbatch typeconcretemixerasperIS:1791andvibratedbyneedlevibratorbut excluding steel reinforcement centring and shuttering in supersturcture. (10.21) |
| 157 | Extra Rate for First Floor |
| 158 | Extra Rate for SecondFloor |
| 159 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc when curved. |
| 160 | Extra Rate for First Floor |
| 161 | Extra Rate for SecondFloor |
| 162 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 163 | Extra Rate for First Floor |
| 164 | Extra Rate for SecondFloor |
| 165 | Chain Link Fencing |
| 166 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 167 | Cement Concrete 1:8:16 with stone ballast of size. 40 mm guage.mixing by mechanical means using concrete mixer volumetric type |
| 168 | CC 1:2:4 with stone ballast |
| 169 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 170 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts & nuts or screws or welding rod, complete fixed in position. |
| 171 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 172 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 173 | Providing & fixing wire mesh GI Chain link 10 gauge mesh size 50mm ISI 2721:1979 fixed with nut and bolt on vertical post and touch welding on horizontal member complete in all respects as per specification and as desired by engineer in charge |
| 174 | Dismantling |
| 175 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doorsof area 3 sqm and below. |
| 176 | Dismantling brick work tile, masonry or tile lining In cement |
| 177 | Add for roof trusses of iron or wood, (rafters, purling etc.) in case of item Nos. 8.10 and 8.11. |
| 178 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 179 | Dismantling concrete Reinforced cement concrete |
| 180 | Credit |
| 181 | Brick bats from well burnt or burnt bricks. |
| 182 | Bricks from dismantling Brick |
| 183 | GI sheet |
| 184 | Credit of Steel and iron |
| 185 | Public Health |
| 186 | Sub Head-1 Tubewell |
| 187 | Drilling of 500mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. complete in all respect. Drilling of 500mm dia bore with Reverse Rotatry Rig Upto 150 m depth BGL. |
| 188 | Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect |
| 189 | Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.Make :- Jindal / Tata or Equilant Make150mm nominal diameter (weight 21.6 kg per metre) 5.4 mmthickness |
| 190 | Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest with SS socket to connect Strainer to Strainer Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore. 150mm Steel Strainer (slot size 0.75mm) 5.00 mmthickness |
| 191 | Supplying, fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest,ISI Marked Duly Welded with suitable grade S,S welding electrode to lower the strainer into the Tubewell bore complete in all respect.150mm internal diameter |
| 192 | Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect. |
| 193 | 150mm internal diameter |
| 194 | Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect. |
| 195 | 150mm internal diameter (weight 21.6 kg per metre) 5.4 mmthickness |
| 196 | Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect |
| 197 | 150mm internal diameter |
| 198 | Supplying & fixing of M.S. Clamp of size 200mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 199 | Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 200 | Supplying at quarry site of gravel of 1/6\" to 1/8\" sizes including pouring and packing in the annual space between the pipe assembly & the bore. The gravel should be free from dust, dirt, or the vegetable manner as per IS 4097-1967 with latest amendments (to be paid as per actual length of pipe) Note: The rates including loading & unloading charges. Carriage from quarry site will be paid extra as per actual |
| 201 | Supplying and fixing mild steel centering guides made out of 32mm X 6mm thick M.S bar complete in all respect |
| 202 | Local /Tibba Sand Incluyding Carriage |
| 203 | Sanitary Seal |
| 204 | Collection of water sample for Heavy metal/Uranium from different strata of sample from approved laboratory (Physical & Chemical Analysis) |
| 205 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) |
| 206 | Drilling trail bore with hand boring machine including rate for electric logging (electric Logging shall be carried out by Contractor up to full depth) complete in all respect water sample of water wearing strata which are suitable for pumping out water shall be tested for Physically & Chemically analysis heavy metal & Uranium. The rates for testing will be separate paid against Tubewell relevant item of this bid carried |
| 207 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. Capacity of Air compressor 300 cfm at250 PSI |
| 208 | Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 209 | Providing & installing,testing & commisioning of 1 noelectrically driven Submersible Pump set of 5 BHP (KSB / crompton equilent make capable of delivering 180LPM against a head of 61 mtr complete in all respect as per specifications |
| 210 | Providing and laying, jointing, fixing, testing ISI MarkedG.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. 50mm i/d |
| 211 | Providing & fixing 2.5mm2 core cable to Submersible Pump complete in all respect as per specifications |
| 212 | Providing and Installing Electric Control panel board consisting of electrical appliances such as automatic star Delta Push Button or oil immersed starter, Main switch, VM, Ampere Meter, ELCB, shut capacitor. Single phase, preventer, indicating laps, Kit-Kat etc. complete ina all respets. |
| 213 | Providing and installing 80 mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber asper standard design complete in all respects |
| 214 | CONSTRUCTION OF V-NOTCH HAUDI.(size 1.80 m x 0.90 m) excluding cost V-notch asper standard design & drawings of public health department. |
| 215 | Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & paintingcomplete in all respects as per standard Drawing |
| 216 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm |
| 217 | Construction of Masonary Gate Pillar including cost of MS Steel Gate size 1.22 mtr x 1.37 mtr as per standard drawing with including D-4 complete in all respects. |
| 218 | Providing & fixing M.S Sign Baord as per standard size of DWSS as per drawing D-20 |
| 219 | Construction of toe wall around water works side as per standard drawing & design |
| 220 | CHLORINATION & DISINFECTION |
| 221 | Providing, installing, testing and commissioning one no. electrically actuated diaphragm operated, meteringsystem,chemicaldosingchlorinator, suitablefordelivering0.5 to 6 ltr. o f bleaching powder solution/ sodium hypo solution per hour under maximum delivery pressure up to 7kg cm2, and suction lift not less than 1.5m, as per DWSS standard specification ( Make: Milton Roy or equivalent Make) |
| 222 | ConstructionofbrickmasonryPumpchamberforwaterworksmeasuring3.05mtx3.70mtht covered with RCC roof slab , lintels , beams doors and windows flooringinternal / external plastering and cost of electric wiring and recessed fittings / accessoriesas per standard design complete in all respects. including sanitary toilet facility of 1.25 mt x 1.50 mt size |
| 223 | Sub Head-2 Estate Water Supply |
| 224 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cuttingin streets or open areaincluding trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. |
| 225 | Earth work upto 1.5 m. Depth All classes of soil except rocky |
| 226 | For 90mm o/d pipe of 10 Kgf. / sqcm |
| 227 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as perspecifications. |
| 228 | 90mm o/d pipe of 10 Kgf. / sqcm |
| 229 | Providing,Laying , fixing & jointing of ISI Marked H.D.P.E. Pipes as per ISI - 4984 along the Trenches andlayingthesameinTrenchestocorrectalignmentandgradients,cutting, jointingandtesting complete as per specifications. (Pipes for Filling OHT Line & External Garden Hydrant)H.D.P.E pipe of 10 Kg. PE-100 40 mm o/d |
| 230 | 50 mm o/d |
| 231 | 63 mm o/d |
| 232 | ProvidingISIMarkedG.MferruleasperIS:2692,drillingandtappingcastironpipelinesofall diametres and screwing in Ferrule and connections complete in all respect. (Making connection from HDPE Lines for Garden Hydrant) 25mm i/d Ferrule heavy duty |
| 233 | Making connection with theexisting DI/G.I.branch mainup to40mm sizepipeincludingcutting of existingpipeline,threadingofpipelinesfrombothendsandfixingofG.I Teeetc.inthepipeline (including cost of G.I Tee) complete in all respects. (Connection from DI/GI main to Hdpe for garden line) |
| 234 | Providing&fixingC.Iindicatingplatesofsize100mmx100mmforSV/FHincludingsynthetic enammelpaint&lettersinwhiteenamelpaint,fixinginthegroundwithangleironofsize 25x25x5mm, 230mm height from ground including concrete block complete in all respect as directed by Engineer-in-Charge. |
| 235 | Providing connection, laying, jointing, fixing, testing MDPE pipe (as approved by Engineer in charge), includingcostofexcavation,refilling,thetrench,CIbibcockasperIS:210withstainlesssteel spindle, 15 mm o/d MDPE pipe 2.50 meter (length on average basis) 15mm o/d GI pipe 2.00 mtr, 3” i/duPVC clamp, GM ferrule ISI marked, connection of 15 mm i/d ferrule medium, specials such as tees, bends, sockets, elbows, nipples (100mm & 150mm), union couplings, GI hooks etc. and gun metal peet valve (heavy pattern) with hand wheels on MDPE/GI pipe line laid in the ground, cutting, threading, making holes in wall and testing in trenches in the ground. All material should be approved make(tobeapprovedofEngineerincharge).Completejobinallrespect(forexternalirrigation/ landscape purpose only) |
| 236 | Sub Head-3 Internal Water Supply System |
| 237 | CONCEALEDIN WALL: Providing and fixing ChlorinatedPolyvinylChloride(CPVC)pipesasper IS15778(ISImarkedwiththepriorapprovalof Engineer-in-Charge),havingthermalstabilityfor hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 238 | Detail attached as per Table-2 |
| 239 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 240 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 241 | CPVC SDR 11 Pipe & fitting 40mm o/d |
| 242 | CPVC SDR 11 Pipe & fitting 50mm o/d |
| 243 | Cuttingchaseinbrickwallsincementorinfloor forembeddingG.I.orC.Ipipeslinesandmaking good the same to its original condition.Size 75mm x 75mm |
| 244 | qty same as cpvc Pipe 20mm i/d to 40 mm |
| 245 | Cuttingholesupto23cmsquarethroughB.B.in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 246 | Through wall 11.43 cm thick Detail as per Table-2 |
| 247 | Through wall 22.86 cm thick Detail as per Table-2 |
| 248 | Providing,fixingandjointing CPVC Union Couplings with Cpvc Pipes complete in all respect. |
| 249 | 20mm i/d cpvc. Union |
| 250 | 25mm i/d cpvc Union |
| 251 | 50mm i/d cpvc Union |
| 252 | Providing,fixingandjointing CPVC Ball valve on CPVC Pipe Lines Including All carriages |
| 253 | 20mm i/d Ball valves |
| 254 | 25mm i/d Ball valves |
| 255 | 50mm i/d Ball valves |
| 256 | Sub Head-4 Internal Sewerage System |
| 257 | ProvidingandfixinginpositionsinglesocketSWR UPVCsoilwasteorantisyphonagepipesasperIS 13592 of E.D.C manufacture or of any other reputedfirmincludingcutting,jointing,wastage, but excluding cost of jointing.Single Socket Type B |
| 258 | 110mm o/d SWR UPVC pipe lines laid complete |
| 259 | 90mm o/d SWR UPVC pipe lines laid complete |
| 260 | ProvidingandfixinginpositionSWRUPVCspecial forsoilwasteventorantisyphonagepipesasper asperIS-14735includingcuttingandwastage etc.cuttingholesinwallsroofsorfloorsetc.and making good to its original condition but excluding cost of lead joining. |
| 261 | For 110mm i/d pipes |
| 262 | Elbow 90 Degree (All side socketed) |
| 263 | Vent Cowls |
| 264 | Coupler |
| 265 | Single Tee With Door |
| 266 | Floor Trap 110mm x 90mm With 90mm i/d outlet deep seal at Ground Floor |
| 267 | Elbow 90 degree (all side socket) |
| 268 | Vent Cowls |
| 269 | Coupler |
| 270 | Single Tee With Door |
| 271 | ProvidingPVCsolventcementjointstoSWRPipes andspecialsincludingcostofPVCsolventcement andtools etc ofapprovedmake(totheapproval of Engineer-in-charge) |
| 272 | 110mm o/d |
| 273 | 90mm o/d |
| 274 | Providing & Fixing in position M.S or heavy flat iron clampsmadeoutof M.Sflatironnotlessthan5 mm of the approved design for fixing C.I. soil waste,ventorantisyhonagepipestowalls complete in all respects including cutting and makinggoodthewallsandfloorsetc.and painting. |
| 275 | M.S. Holder bats clamps for 100mm i/d as per table-1 |
| 276 | M.S. Holder bats clamps for 75mm i/d as per table- 1 |
| 277 | Providingandfixinginposition PVC gullytrapsfixedin cementconcrete1:4:8completewithGrating 150mmx150mm,coverandframeclearopening 300mmx300mmandoutofsidesize330mmx 330mmandchamberincludingcostofallbricks workincementmorter1:5cementconcrete1:2:4 in coping around cover and frame etc.as per standarddesignminimum depthofwatershould be 150 mm with a minimum seal 50mm. |
| 278 | 100mminternalDiametre PVC.gullytrapwith andframeclearopening 300mmx300mmandoutofsidesize330mmx 330mm as per table-1 |
| 279 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre averagedepthin1:5cementsandmortar, C.C.1:4:8(150mmthick)infoundation,cement concrete1:2:4 benching 12.50mmthick cement plaster1:2withafloatingcoatof1mmthickof neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x455mm,455mm x610mm insideR.C.C. inspection chamber cover and frame (Weight asperI.S.Ispecifications)paintedwith3coatsof black bitumastic paint conforming to I.S.I complete as per standard design. |
| 280 | 450mmx600mminsidewith455mmx610mm cover and frame light duty double seal |
| 281 | Sub Head - 5 Sanitary Installation |
| 282 | Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grabrails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 283 | Providing and fixing in position Chinaware European type watercloset P trap orS trap of approved make (to the approval of the Engineer-in charge) consisting of 10 ltr. PVC flushing cistern ISI marked,PVCshortbend32mmdiaincludingcost ofseatcovercompleteinallrespectandtothe entire satisfaction of Engineer-in-charge. |
| 284 | Providingandfixingjetspraywith2\"-6\"longPVC pipe.With C.P Brassnut |
| 285 | Providing & Fixing in position C.P. Brass Hexa Nipple15mmofapprovedmake(totheapproval of Engineer-in-charge ) complete in all respect. |
| 286 | Providingandfixingin positionvitreous chinaware white lavatory suites of approved make (to the approvalofEngineer-in-charge)consistingofC.P. brasswaste32mmdiawithoneC.P.brasspillar tapincludingRackBoltScrewPair115mmlong complete in all respect. Size 560mm x 450 mm (under counter oval) |
| 287 | Providing and fixing in position stainless steel sinksofapprovedmake(totheapprovalof Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.Double Bowl sink without drain board Overall size 1114 x 490 mm with bowl size 460 x 385x200mm including waste coupling |
| 288 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in charge)consistingofC.P.brassUrinalwaste Couplingdometype32mmouterlength75mm, C.P.brass UrinalSpreader Ocular-Regularand C.P. brass tube connection 300 mm long complete. |
| 289 | Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm |
| 290 | Providing and fixing in position vitreous Chinaware whitechannelofapprovedmake(totheapproval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. |
| 291 | Providing opening of required size & shape for washbasin/kitchensinkinkitchenplatform, vanity counter and similar location in marble/ granite/stonework,includingnecessaryholesfor pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 292 | Providing & fixing in position PVC flexible tube connectionofapprovedmake(totheapprovalof Engineer-in-charge ) complete in all respect.PVC tube connection of size 15 mm x 450 mm with CP Brass nut |
| 293 | ProvidingandfixingP.V.CWastePipeCollapsible 32mm complete in all respect. |
| 294 | Providingandfixing inposition towelrails/ring ofapprovedmake(totheapprovalofEngineer-in- charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. C.P brass towel ring |
| 295 | ProvidingandfixinginpositionC.P.brasssoap dish ofapprovedmake(totheapprovalof Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 296 | Providing & Fixing in postion 15 mm i/d bib cock of approved make(totheapproval of Engineer-in- charge )complete in all respect. C.P.brassBibcocklongnose/longbodywithout flange |
| 297 | C.P Brass bib cock foam flow without flange |
| 298 | Providing & Fixing in postion stop cock / Angle valveofapprovedmake(totheapprovalof Engineer-in-charge ) complete in all respect. C.P.brass 15mm Angle valve without flange |
| 299 | C.P.brass 15mm Concealed stop cock with flange For Jet Spray Connection + Over Head Shower |
| 300 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect. |
| 301 | Providing&FixinginpositionC.P.Brassextension piece 25mm long to 100mm long of approved make(totheapprovalofEngineer-incharge)with various fixtures complete in all respect.C.P.Brassextensionpiece,25mmlongto50mm long |
| 302 | Providing&Fixinginposition5mmthickbevelled edgemirrorofsuperiorglass(ofapprovedmake) complete with 4mm thick hard board backing fixedinwithrawlplugs50mm,C.P.brassscrews andwashersandS/SStudsontop completeinall respect(asrequiredbytheEngineer-in-Charge) (Size 600mm x 450mm) |
| 303 | Providing&FixinginpositionC.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge)fixedintowall withC.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 3 pegs |
| 304 | Providing&placinginpositiononterrace(atall floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with coverwithsuitablelockingarrangementand makingnecessaryholesforinlet,outletandover flopipesbutwithoutfittingsandbasesupportfor tank. Tripple Layer Tanks 2000 ltr Capacity |
| 305 | Providing and fixing in position automaticbrass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball 25 mm i/d |
| 306 | Providing,fixingandjointing CPVC Tank nipple in HDPE Water Storage Tanks . Complete in all respect. Cpvc. tank nipple 25mm i/d |
| 307 | Cpvc tank nipple 50mm i/d |
| 308 | Construction of Platform complete as per specification & as desired by Enginer-in-charge For 2000 ltr Water Tank |
| 309 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects |
| 310 | Providing and fixing in position C.P. Brass overhead shower 1 flow with shower arm with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 311 | Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve completeincluding fixing and testing complete in all respect. Vertical Type 25 litre capacity water heater |
| 312 | Sub Head-6 Flooring and Wall Tile |
| 313 | Base course of floor consisting of 100mmthick cement concrete1:8:16 withstone aggregate 40mmguageand100mmfinesandfillingusing mechanical mixer for mixing of material |
| 314 | Screed of 50mm thick cement concrete 1:8:16with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material First Floor |
| 315 | ProvidingandlayingRectifiedPorcelinfloortiles 400x400mmormore(thicknesstobespecifiedby themanufacturer)ofpremiumqualityconforming to IS:15622 of approved make in all colours laid on 20mmthickbedofCementMortar1:4(1Cement : 4 Fine sand) for new flooring complete . |
| 316 | Extra rate for First Floor |
| 317 | Providingandlayingwaterproofingtreatmentto verticalandhorizontalsurfacesofdepressed portions of W.C., kitchen and the like consisting of:i)Ist course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS:2645 in recommended proportions including rounding off junction of vertical and horizontal surface.ii)IIndcourseof20mmcementplaster1:3(1 cement : 3 coarse sand) mixed with water proofing compoundinrecommendedproportionincluding rounding off junction of vertical and horizontal surface.iii) IIIrd course of applying blown or residual bitumenappliedhotat1.7kgpersqmofarea.iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm). |
| 318 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/ Glosy/ Highly Gloss finish/ Highlighter/ emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 319 | Extra Rate for First Floor |
| 320 | ColouredGranitestonetiles15mmto20mmthick inskirting,risersofsteps,dadowallsandpillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixedwithpigmenttomatchtheshadeofstone, includingrubbingandpolishing includinglabour for fixing dowel pins and cramps.. |
| 321 | Extralabourforprojectednosingofstaircaseof any shape and design |
| 322 | SubHead-7DrinkingWaterCooler |
| 323 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge)includingcarriagecomplete in all respect.Water Cooler Full Steel Body 150/150 ltr without Stablizer |
| 324 | Supply and erection ofSingle phase copperwound Automaticvoltagestablizerofsuitablecapacity electronically controlled circuit with input voltage 140- 260voltssinglephaseACsupplyandoutputvoltage220 ±5%voltssinglephaseACsupplyhavingmainsilicon core copper woundstep uptransformer withsuitable nos. ofturnsonprimarysideandsecondarysidethe transformershouldbefullyinsulatedinsidetheMSsheet box ofsuitablesize.Thereshouldbepowercontrolrelay andsinglepoleMCB(C-curve,10kA)ofsuitablecapacity complete with internal copper wiring along with amp. meterandvoltmeter,highvoltagecutoff280voltinput (240volt output)and90 volt maximumboost and overloading protection to be provided:- Automatic Voltage Stablizer 2 KVA |
| 325 | Providing & fixing in position Commercial ROwithout reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 326 | Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineerin- charge ) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packageddrinking water bottles and carriage complete in all respect. |
| 327 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 328 | Sub Head-8 Estate Sewerage |
| 329 | Providing,layingin trenchestocorrectgradient and alignmentandjointingofUPVCpipeshaving ISIspecification IS:15328-2003 class-SN-8 marked make Supreme, Finolex,Kissan, Jain,Prince or equivalent good on them and laying the same intrenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 330 | 160 mm o/d pipes |
| 331 | 200 mm o/d Pipe |
| 332 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manuallydressing bed, trimming sides and side slopes for sewers andmanholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electriclines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.Fordepth exceeding3.0mbutnotexceeding4.5 m B.G.L. For all classes of soil except rocky |
| 333 | Constructing brick masonry manhole in cement mortar 1:5 (1cement:5coarse sand)R.C.C. top slab 20cm thick using M-20mix by using mixer and vibrator,TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand:8graded stone aggregate 40mm nominal size) inside plastering 12mm thick withcement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thickbenching incement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20mm nominal size) finished with floating coat of neat cement, Orange coloured PVC stepsincludingRCCcoverwithframecompleteas per standardInside size 90x150 cm and 120 cm deep |
| 334 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 upto 1.80 m increase in depth. Inside size 90x150 cm |
| 335 | SubHead 9 Roof Top Rain water Harvesting |
| 336 | Providing, Laying , fixing & jointing ofP.V.C. Pipes as perISI-4985(ISImarkedwiththepriorapprovalof Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting,jointingandtestingcompleteasper specifications.100mm o/d PVC pipe of 4 Kgf. / sqcm |
| 337 | 160mm o/d PVC pipe of 4 Kgf. / sqcm |
| 338 | 200mm o/d PVC pipe of 4 Kgf. / sqcm |
| 339 | Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc.night signals, profiles, pegs,sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing,refilling trenches, watering, ramming and restoration of surface to original level removal of surpluspoils from the site of works upto chain (15 m), complete in all respects.For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky |
| 340 | Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. |
| 341 | Construction of Haudi internal size 0.90mtr x0.90mtr & 0.90mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete1:8:16,RCCSlabcover75mmthickinside plaster,cementrendering&RCCmanholecover 450x600mmclearinsideopeningrectangularRCC Manhole cover with frame Light Dutycomplete as per Drawingattached&asdesiredbytheEngineer-in- charge |
| 342 | Construction of Haudi internal size 0.45mtr x0.45mtr & 0.45mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete1:8:16,RCCSlabcover75mmthickinside plaster,cementrendering&RCCmanholecover 450x450mmclearinsideopeningrectangularRCC Manhole cover with frame Light Dutycomplete as per Drawingattached&asdesiredbytheEngineer-in- charge |
| 343 | Construction of Rain water recharge well 3.00mtr dia with working depth 3mtr dia consisting of drilling bore 300mm dia 35mtr, supplying and lowering pvc perforated housing pipe 200 mm dia 10kgf/sqcm 50mtr sorrunded with filtermedia , galvanised stainer CI pipe Class LA 150mm i/d 4mtr duly plugged from top with bail plug, fixing MS clamp, MS socket, Well size 3.00 mtr internal dia, 4 mtr deep constructed with BB in 1:5 cement sand mortar,plastered from inside, RCC slab, filtered media in 3 Layers, 2Nos RCC Man hole cover conneted with collecting chamber size 1mtr x 1mtr x 1.20 mtr deep providing and fixing MS grating and all other relevent material required as per site complete in all respect as per drawing attached and entire satisfaction of the Engineer-in-charge . |
| 344 | Sub Head 10 Storm water Harvesting |
| 345 | Providing, Laying , fixing & jointing ofP.V.C. Pipes as perISI-4985(ISImarkedwiththepriorapprovalof Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting,jointingandtestingcompleteasper specifications. 160mm o/d PVC pipe of 4 Kgf. / sqcm |
| 346 | Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc.night signals, profiles, pegs,sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing,refilling trenches, watering, ramming and restoration of surface to original level removal of surpluspoils from the site of works upto chain (15 m), complete in all respects. For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky |
| 347 | Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. |
| 348 | Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick C.C 1:6:12 in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar (as specified in item No. 29.74) complete and to the requirement of the Single Road Gully chamber Size 610mm x 457mm x 1105mmRWH2 |
| 349 | Construction of Rain water recharge well 3.00mtr dia with working depth 3mtr dia consisting of drilling bore 300mm dia 35mtr, supplying and lowering pvc perforated housing pipe 200 mm dia 10kgf/sqcm 50mtr sorrunded with filtermedia , galvanised stainer CI pipe Class LA 150mm i/d 4mtr duly plugged from top with bail plug, fixing MS clamp, MS socket, Well size 3.00 mtr internal dia, 4 mtr deep constructed with BB in 1:5 cement sand mortar,plastered from inside, RCC slab, filtered media in 3 Layers, 2Nos RCC Man hole cover conneted with collecting chamber size 1mtr x 1mtr x 1.20 mtr deep providing and fixing MS grating and all other relevent material required as per site complete in all respect as per drawing attached and entire satisfaction of the Engineer-in-charge . |
| 350 | Sub Head 11 Fire Fighting |
| 351 | ProvidingandfixingofFIREEXTINGUISHERCO2 type as per IS:15683complete withall accessories as per manufactures sepcification. ISI Mark Complete in all respect.4.5kg capacity |
| 352 | ProvidingandfixingofFIREEXTINGUISHERABC powder type (Stored pressure) as per IS:15683 completewithallaccessoriesasper manufactures sepcification. ISI Mark Complete in all respect.6 Kg. Capacity |
| 353 | M.S PIPE(On Surface)Providing, laying, Fixing, testingand commissioning of \"C\" Class heavy duty MS pipe Confirming to Indian standard IS. 1239/3589 including fitting like tees, bends, sockets, elbows, flanges,tapers, nuts bolts, gasket etc. fixing the pipe on the wall/ ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete inall respects. Make:- Jindal 100mm i/d |
| 354 | HYDRANT LANDING VALVE:- Supplying,Installation, Testing & Commissiong of G.M Single headed hydrantvalvewithinstantaneousGunmetalpeetCouplingof63mmdiawithcastironwheelISI markedconformingtoIS5299(typeA)withblankGunmetalcapandchainincludungorificeplate madeof6mmthestainlesssteeltokeepthepressurenotmorethan3.5persqcmatanypointcomplete in all respect. |
| 355 | BRANCHPIPE:-Supplying,installation,testingandcommissionof63mmgunmetal Branch pipe(ISI marked) with 20mm(normal internal dia) size gunmetal nozzel confirming to IS 903, suitable for instantaneousconnectionto interconnection hose pipe coupling as required |
| 356 | FIREBRIGADEINLET:-Providing&fixingFireBrigadeinletconnectionofcastironbodywith gunmetal63mmdiainstantaneoustypemalecouplingswithbuilt-incheckvalvesand150mmdia, flangedoutletcompletewithbolts,nutsandrubberinsertionsasperIS:904.MAke:-Padmini,Life Safety,SafeGuard,OmexTwo way inlet connection |
| 357 | RRL HOSE PIPE:- Supplying , installation, testing and commission of RRL fire hose type A, IS: 636, 63mmdiax15m longwith gunmetal maleandfemalecoupling(ISI marked)bound&rivertedto hosepipeswith copperrivetsandcopper wireasrequired. |
| 358 | FIRSTAIDHOSEREEL:-Supplying,installation,testingandcommissioningofFirst-Aid-fireHose reelwithMSconstructionspraypaintedinpostofficered,confirmingtoIS884withoptodate amendmets,completewithrubberhosepipe(IS:444/1987)20mmdia30meterlongtype-2, hose reeldrumwithbracketasperIs:884,20mmdiaGMnozzleand20mmdiaGMgatesvalveas requiredwithcomplete withG.Ipipeconnectionwithmainpipecompleteinallrespect. |
| 359 | HYDRANT BOXSupply,installation,testing&Commissioningofweatherproofcabinetforhosefabricatedoutof 1.6mmthicknessM.Ssheetwiththefrontglassdoorhavinglockingarrangement,suitableto accomadate all the necessary pipes, accessories, fitting etc. including painting the metal portion with onecoatofreadymixedprimerpaintandtwoenamelcoatsofsyntheticpaintofallapproved quality,shade and sign writing etc. 750mm wide x 600mmhigh x 250mm deep |
| 360 | AIRVESSEL:- SupplyandfixingofAirvesselmadeoutof250mm.Dia,8mmthickMSsheet, 1200mmheightwithairvalvesonthetopandflangedconnectiontoriser,drainarrangementwith 25mmdiagunmetalwheelvalves,withrequiredaccessories,pressuregaugeandpaintimgwith synthetic enamel plant of approvedshades as required. |
| 361 | PRESSURE GAUGE:- Providing &fixing S.SPressureGuagecompleteasrequiredcompletein all respect. Diadiameter 100mm calibration 0-16kg. |
| 362 | WATERSTORAGETERRACETANK:-ProvidingandplacinginpositiononterraceHDPEwater storage tank of approved make ( to approval of Engineer-in - charge) with cover with suitable locking arrangement and making necessary holes foe inlet, outlets and over flow pipes but without fittings and base support tank. Make:- Sintax,DiplastTriple layer Tank |
| 363 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 364 | Supplying, Installation, Testing and Commissioning standard Fire Man\"s axe with heavy insulated rubber conforming to IS 936 complete in all respect. |
| 365 | Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.100mm i/d check |
| 366 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- Overall size 10sq.mm (4Core) Armoured |
| 367 | Providing & Fixing ofe pump in back pull out design having 50mm suction, 32mm delivery , CI Casing,bronze impeller and CS Shaft with gland packing arrangement on common baseplate to Kirloskar or equivalent make, 2900 RPM TEFC sq Cage induction motor suitable for 3 phase , 415V, 50 Hz AC supply Confirming to through suitable flexible coupling. The pump set is suitable for following duties: 450 LPM at 35mtr head. |
| 368 | Providing and Fixing of Electrical Control panel of cubical type floor mounted having MCB 50A 3P 10KA, Contractors MNX 32a , Relay 14-23-A, Add on block 2no+2NC, SP MCB 6,SPPR Relay 415V AC Digital Meter set, Hardware, Aluminium Bud Bar set, wire and thimble, Complete in all respect. |
| 369 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-incharge) in PVC Water storage tanks complete in all respect. |
| 370 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and PlasticBall 50mm i/d |
| 371 | Providing, Laying,Fixing, testing and Commisioning of Annunciation Panel, with LCD display(16*2) or without display having area wise display facility. The panel must be able to Assciates with any make of fire alarm panels. As per IS:2189, Compatable with all types of flow switches. Make:- Agni Devices,ASES , Lakshita. |
| 372 | Construction of Platform complete as per specification & as desired by Enginer-in-chargeFor 2000 ltr Water Tank |
| 373 | SUB HEAD 12 AIR CONDITIONING |
| 374 | Providing&Installing&Erectionsplittypewallmountedairconditionercapacity2.0tonne3StarMake:-Toshiba,MitsubishiElectric,Daikin,O\"General,Hitachi, voltas witharrangement forinstallingODunitson terraceincluding 3 mtr inletandoutletcoppertubeswithproperinsulationdrainage arrangementcablelinkbetweenIDunitandODunitsstandforODunitand connectionofconcealingofCopperpipesanddrainagepipe withinbuildingand installing charges complete in all respects |
| 375 | Providing&Installing&Erectionsplittypewallmountedairconditionercapacity1.50tonne3StarMake:-Toshiba,MitsubishiElectric,Daikin,O\"General,Hitachi, voltas witharrangement forinstallingODunitson terraceincluding 3 mtr inletandoutletcoppertubeswithproperinsulationdrainage arrangementcablelinkbetweenIDunitandODunitsstandforODunitand connectionofconcealingofCopperpipesanddrainagepipe withinbuildingand installing charges complete in all respects |
| 376 | Providinglayinghardsoftcopperconcealingofcopperpipesofdia12.7mm od (insulation=13mm)/9.5mmod(insulation=13m)asperrequirementandwall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / tapinglayinginchasecuttingofwallandrepairingthesamewithinthebuilding and installing charges complete in all respects. |
| 377 | AUTOMATIC VOLTAGE STABLIZER, TIMER:- Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided: Automatic Voltage Stablizer 5 KVA |
| 378 | Cuttingchaseinbrickwallsincementorinfloor forembeddingG.I.orC.Ipipeslinesandmaking good the same to its original condition.Size 75mm x 75mm |
| 379 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.uPVC Pipe 6 Kgf/cm2 |
| 380 | Providing And fixing powder coated angle iron stand heavy duty includinggrouting for outdoor unit complete in all respect |
| 381 | Providing Internal Electrical Installations in Indoor Sports Hall |
| 382 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: |
| 383 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point)and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 384 | Wiring fan point (With fan box) |
| 385 | Wiring light point |
| 386 | Wiring call-bell point |
| 387 | Wiring 6Amp. wall socket point |
| 388 | Wiring 6Amp. Plug control comprising wall socket point |
| 389 | Wiring 16/20Amp. power plug control point |
| 390 | Wiring light point with double control switches. |
| 391 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 392 | Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) andmodular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 393 | Wiring AC supply terminal point having1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 394 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPEWIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 395 | Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 396 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universalsocket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 397 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): |
| 398 | Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 399 | Wiring Telephone socket point RJ11 (one module) |
| 400 | Wiring Networking socket point RJ45 (one module) |
| 401 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 402 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 403 | Overall size 1.5sq.mm (Un-sheathed) |
| 404 | Overall size 2.5sq.mm (Un-sheathed) |
| 405 | Overall size 4sq.mm (Un-sheathed) |
| 406 | Overall size 10sq.mm (Un-sheathed) |
| 407 | Overall size 16sq.mm (Un-sheathed) |
| 408 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 409 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materialsetc., as per PWD General Specifications:- |
| 410 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 411 | Heavy Gauge PVC Conduit Pipe 32mm dia. (Flushed) |
| 412 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 413 | MINIATURE CIRCUIT BREAKERS: |
| 414 | Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specificationsincluding connections with suitable size of thimbles/lugs:- |
| 415 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 416 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 417 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 418 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB\"s/ RCBO\"s/ RCCB\"s: |
| 419 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mountingminiature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&Ndistribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&Nhorizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 420 | TP&N Horizontal Double Door Distribution Board 4 way each |
| 421 | TP&N Horizontal Double Door Distribution Board 6 way each |
| 422 | TP&N Horizontal Double Door Distribution Board 8 way each |
| 423 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB\"s as incomer and outgoings SP/TPminiature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 424 | TP&NDouble Door Vertical DB\"s 8 way each (With provision of upto FP MCCB125amp.) |
| 425 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): |
| 426 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 427 | Overall size 10sq.mm (2Core) Un-armoured (On-Surface) |
| 428 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE): |
| 429 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 430 | Overall size 10sq.mm (2Core) Un-armoured (Loose) |
| 431 | Overall size 25sq.mm (3½ Core) Un-armoured (Loose) |
| 432 | Overall size 150sq.mm (3½ Core) Un-armoured (Loose) |
| 433 | Overall size 16sq.mm (4 Core) Un-armoured (Loose) |
| 434 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: |
| 435 | Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 436 | Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) |
| 437 | Double Walled Corrugated HDPE Pipe 90/ 76mm (Outer/ Inner dia.) |
| 438 | COPPER EARTHING: |
| 439 | 8 SWG COPPER EARTHING : |
| 440 | Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 441 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 442 | COPPER EARTHING STRIP (As Additional Length): |
| 443 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 444 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 445 | COPPER EARTHING: |
| 446 | COPPER EARTHING (Upto 14 metre in Length): |
| 447 | Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc.,up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 448 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 449 | COPPER EARTHING STRIP (As Additional Length): |
| 450 | Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 451 | Additional Length 20mm x 3mm thick Copper Tape |
| 452 | SMC GLASS FIBRE INSPECTION BOXES: |
| 453 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangementcomplete in allrespect as approved and desired by the Engineer In-Charge at site:- |
| 454 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound)confirm to IS:14772, inner dimensions 300mm x 200mm x 105mm with hinged water tight cover with locking arrangement |
| 455 | SHEET METAL IRON CLAD SWITCHES: |
| 456 | Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure includingconnections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- |
| 457 | ICDP Switch 32amp., 415volts |
| 458 | MCCB\"s (FOR PANELS & SHEET ENCLOSURE): |
| 459 | Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevantPWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 460 | MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 461 | MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 462 | MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 463 | MCCB Four Pole 250amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
| 464 | ON LOAD CHANGEOVER SWITCH |
| 465 | ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): |
| 466 | Supply and erection ofOn Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- |
| 467 | On Load Change Over Switch Four Pole 250amp., 415volts |
| 468 | LT PANELS & MCCB\"s (MOULDED CASE CIRCUIT BREAKERS): |
| 469 | LT PANELS: |
| 470 | Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. |
| 471 | The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. |
| 472 | The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. |
| 473 | Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB\"s. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. |
| 474 | Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:- |
| 475 | LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB\"s40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm) (For High Mast and Street Lighting) |
| 476 | LT Panel enclosure having space for 1No. Incomer MCCB 400Amp. and 8Nos. outgoing MCCB\"s40amp. to 160amp. according to the requirement at site (Approx. size 1750 x 1750 x 400mm) (Main Panel) |
| 477 | SUPPLY AND ERECTION OF WIRING ACCESSORIES: |
| 478 | Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 479 | Ceiling Rose (Flush Piano type) |
| 480 | Bakelite Batten Holder (Large size) |
| 481 | HEAVY GAUGE WELDED CONDUIT PIPES: |
| 482 | Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 483 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. |
| 484 | Supply and erection of LED batten 20 Watt LED (including constant LED driver) withHigh quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per wattand operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 485 | Supply and erection of LED batten 36/40 Watt LED (including constant LED driver) withHigh quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per wattand operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 486 | Supply and erection of Slim Recessed mounted, Round downlighter 18 watt (including constant LED driver) with Pressure die cast aluminium housing with efficacy of LED fixture minimum 100 lumens per wattand operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 487 | Supply and erection of Surface mounted round downlighter 18watt (including constant LED driver) with Pressure die cast aluminium housing with efficacy of LED fixture minimum 100 lumens per wattand operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/ IEC standards) wattage of each low power LED less than 1watt input AC frequency 50 Hz ± 3 % with 5 year warranty including their drivers completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 488 | Supply and erection of Recessed Mounted 36 Watt LED 2x2 panel (including constant LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per wattand operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited labortary. |
| 489 | SupplyanderectionofCeilingmountedOccupancybasedPIRsensor(360degree) withinstallation height2.5mts,8.5Ampsresistiveload,Detectiondia8M, timedelay-5sto59mins,Lightlevel threshold-5to1275Lux, IP-20,SensitivityAdjustment,WalkLEDtest,withadditionaloptionslike walkthrough, daylight set point, vacancyetc.as required complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 490 | Supply and erection of High efficiency round highbay 150 Watt Surface mounted Weather proof corrosion resistant, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver)with pressure die cast or extruded aluminium housing with control gear (IP 66 protection) for industrial and other applications in exposed climates requiring higher degree of ingress protection, THD<10%, CRI minimum 70,High power LED (with wattage 1 to 5 Watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK 07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon\"ble Technical Advisor to Punjab Govt. vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 491 | Supply and erection of AC Ceiling Fan 1200mm (48\") BEE 3 Star Rating suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 218 CMM. The rated speed of the the product must be minimum of 350 revolutions per minute and 5Nos. of speeds. The approximate weight of the product should be 4Kg and 180gms.(without packing) or higher. The product should have a manufcaturer\"s guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer-in-charge at site. |
| 492 | Supply and erection of Wall Fan Plastic Body 400MM, 18\" including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. |
| 493 | Supply and erection of Air Circulator 600mm sweep wall mounting to be fitted on wall/ surface etc. making all the necessary connections including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. |
| 494 | Supply and erection of Heavy duty Exhust Fans 300mm sweep 900RPM complete with aluminium louver shutter Canon Make, double ball bearing, longer life including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. |
| 495 | Supply and erection of Heavy duty Exhust Fans 380mm sweep 900RPM complete with aluminium louver shutter Canon Make, double ball bearing, longer life including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. |
| 496 | Supply and erection of Heavy duty Exhaust Fans 450mm sweep 900RPM complete with aluminium louver shutter Canon Make, double ball bearing, longer life including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. |
| 497 | Supply and erection of LED Flood Light 120watt, Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver)with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70,High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon\"ble Technical Advisor to Punjab Govt. vide LetterION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 498 | Supply Installation, Testing, commissioning & Laying of Cat 6 Cable with conduit as required Category 6 Unshielded Twisted Pair 23 AWG:305mtr. ,4 pair 100W cable shall be compliant with ANSI/TIA/EIA-568-C.2 Additional Transmission Performance Specifications for 4-pair 100W Category 6Cabling. Tested upto 600 MHZ; Construction: 4 twisted pairs separated by internal X shaped, 4 channel, polymer spine / full separator. Half shall not be accepted.Sheath : FRPVC/LSZH, Outer Diameter 6.1 mm nominal;Temperature Range -20° to +60°C.Manufacturer should have ISO 9001:2008 Certification for Quality Management System.Manufacturer should have ISO 14001:2004 Certification for Environmental Management System.All UTP and Its Components should be from same OEM. complete in all respectsincluding warrenty and service for one years complete in all respect as desired by the engineer in charge at site. |
| 499 | Heritage & Culture Cess @ 1.00% |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy