| 1 | Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etcup to 10m height complete all as specified and directed. |
| 2 | M&L for rendering 10mm thick in CM 1:6 other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cementcomplete. |
| 3 | M&L for rendering 5 mm thick in CM 1:4 on ceiling other than fair faces of brick work or concrete surfaces finished without using extra cementcomplete. |
| 4 | M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper over one coat ofwall care putty complete all as specified. |
| 5 | M&L preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 6 | Complete removal of existing treatment by scraping, rubbing , brooming down,washing with water etc of old decorated surfaces plastered or unplastered surface of wall and applying two coat of oil bond distemper over one coat of putty on wall complete all as spcefied and as directed by Engr-in-charge. |
| 7 | M&L preparation of Old or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 8 | M & L for preparation of Old or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. |
| 9 | S & F for Aluminium drapery Rod 25mm dia Powder Coated including wooden side caps, brackets, and rings @ 120mm c/c complete all as approved by Engineer-in-charge. |
| 10 | Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 11 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet coverfor housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge. |
| 12 | One light/fan point controlled by oneway switch |
| 13 | One bell /buzzer point controlled by one bell push |
| 14 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 15 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board |
| 16 | All as per item No 11 above but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge. |
| 17 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall& including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover/Modular cover for terminal boxes also including porvision of earth wire PVCinsulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following : |
| 18 | One light/Exh fan point controlled by oneway switch |
| 19 | One bell /buzzer point controlled by one bell push |
| 20 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on independent board. |
| 21 | One 3 pin 5 Amps socket outlet point controlled by oneway switch on same board |
| 22 | All as per item No 13 above but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge |
| 23 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 1 module / 2 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etcincluding make good of disturbed surface complete all as specified and directed by Engineer in charge.Note-Switch,socket, regulator will be paid separately. |
| 24 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 3 module / 4 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etcincluding make good of disturbed surface complete all as specified and directed by Engineer in charge.Note-Switch,socket, regulator will be paid separately. |
| 25 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 6 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc.including make good of disturbed surface complete all as specified and directed by Engineer in charge.Note-Switch,socket, regulator will be paid separately. |
| 26 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 8 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etcincluding make good of disturbed surface complete all as specified and directed by Engineer in charge.Note-Switch,socket, regulator will be paid separately. |
| 27 | M&L in replacementswitch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 28 | M&Lin replacement switch modular type 6amp SP two way, 1 module complete all as specified and directed by Engineer in charge. |
| 29 | M&L in replacement Modular Bell pushbutton SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 30 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 31 | M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. |
| 32 | M&L in replacement Modular socket outlet 2/3 pin 6/16Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 33 | M&L in replacement modular stepped type electronic fanregulator 120W, 2 module all as specified and directed by Engineer in charge. |
| 34 | M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge. |
| 35 | M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge. |
| 36 | M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge. |
| 37 | M&L in replacement switch piano flushbutton type single pole 16 Amps complete all as specified and directed by Engineer in charge . |
| 38 | M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. |
| 39 | M&L in replacement socket outlet6 Amp flush button type complete all as specified and directed by Engineer in charge. |
| 40 | M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. |
| 41 | M&L in replacement bell electric (dingdong) 230 volt, SPall complete all as specified and directed by Engineer in charge . |
| 42 | M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge. |
| 43 | S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge . |
| 44 | M&L in replacement sheet metalenclosure, single pole and neutralwith a two pin and earth plug and socket 240 Volts grade20Amps complete with onesingle poleMCB \"B\" series 10/20 A capacity complete all as specified and directed by Engineer in charge. |
| 45 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, > 2400 systems lumen outputwith lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1,Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed completeallas specified and directed. |
| 46 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 47 | Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 25,000 burning hours at L70 criteria,Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 48 | S&F in replacement of decorative type wall mounted luminaire (Comet)with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge . |
| 49 | Supply and fix surface ceiling mounted, LEDdown light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 25000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driverwithvoltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed completeallas specified and directed. |
| 50 | Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 51 | Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 52 | Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link completeall as directed by Engineer -in- Charge. |
| 53 | Supply and fixMCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link completeall as directed by Engineer -in- Charge. |
| 54 | Supply and fixin repair MCB DP 63 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge . |
| 55 | Supply and fixin repair MCB DP 40 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge. |
| 56 | Supply and fixin repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ \"C\" curve complete all as specified and directed by Engineer in charge |
| 57 | Supply and fixing Ventilating Fan250 mm sweep, 1250 RPM, non metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 58 | Supply and fixing Exhaust fan300 mm sweep(steel Body) , 1250 RPM, metallic resin body,single phase 240 volts AC 50 Hzand connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan completeall as specified and as directed. |
| 59 | Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed. |
| 60 | S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tankmaterial of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure completeall as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating with minimum two year warrant on product.Note : old unservicable geyser will be deposoted in MES yard. conversion against low rating to 5 star rating. |
| 61 | Supply and fixing ceiling fans complete with blade, down rods, with remote and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM, BEEfive star rated voltage range 140 - 280 volts with brushess direct current motor (BLDC)all as specified and directed by Engr in Charge. (Against BLDC converson). Old fan deposited to MES yard. |
| 62 | Supply and fix in repair MCCB 125 Amps, FP 415 volts 16KA , 4 Pole, 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. |
| 63 | Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. |
| 64 | S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 65 | Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduitin walls all as specified and as directed. |
| 66 | Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through drawn through and including 25 mm dia non metallic rigid PVC conduitin walls all as specified and as directed. |
| 67 | Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through drawn through and including 25 mm dia non metallic rigid PVC conduitin walls all as specified and as directed. |
| 68 | S&F plug top, 3 pin,20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge. |
| 69 | S&F socket 3 pin20 amp earth metal clad(ISImarked) complete all as specified and directed by Engineer in charge . |
| 70 | S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 71 | S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 72 | S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge. |
| 73 | M & L forin replacement onlysingle core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 74 | M & Lin replacement foronlysingle core PVC insulated cable2.5Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 75 | M & Lin replacement foronlysingle core PVC insulated cable4Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 76 | M&L in replacement copper cable flexible 2 corePVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. Length of wire of each roll is not less than 90 mtr. |
| 77 | Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed. |
| 78 | Supply only heating element of 2 KW any type with nut bolt washercomplete all as directed. |
| 79 | Supply only heating element of 1.5 KW any type with nut bolt washercomplete all as directed. |
| 80 | Supply only replacement of capacitor 3.15 Mfd,240 V complete all as specified and directed. |
| 81 | M & L for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out /unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge. |
| 82 | Supply only replacement of capacitor 2.5 Mfd,240 V complete all as specified and directed. |
| 83 | S&F LED 2 X 2 ft backlite surface mounted fitting 36 Wattsnot less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours ,Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed. |
| 84 | S&F not less than 35W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover.System level efficacy of the Luminarieshould more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected.It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision ofsuitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 85 | supply only hole fastner madeup of MS 6\" long with complete nut bolt all as specified. |
| 86 | Schedule of Credit |