| 1 | Supply and laying 100 mm bore GI tubing medium grade including all fixture/ fittings for connection laid in trenched as per site requirement and directed by Engr-in-charge. |
| 2 | Supplying and fixing cast iron sluice valves ISI marked with hand wheel suitable for cast iron pipe of 100 mm bore, both ends flanged rating PN-1.6 with SS spindle as in repairs including jointing with New MS nutsand bolts, washers and gasket etc all as per IS No. 14846. |
| 3 | Supply and fix Non Return Sluice Valve 100 mm dia complete all as specified & directed by Engr in Charge. |
| 4 | Construction of brick masonary valve pit of size 1200x1200x1200mm (Internal dimension) incl necessary earth work and MS sheet 3 mm thick cover with angle iron frame 40 mm x 40 mm x 6mm including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer all as shown in drg held with GE office incl of tapping of 100 mm GI pipeline from existing 150 mm GI pipeline complete all as specified directed by Engr in Charge. |
| 5 | S&F Submersible pump, electric driven 415 V, TP up to 10 HP suitable for 200/250 mm dia bore well ( Casing pipe size 200/250 mm) with all accessories, fittings and hanging with nylon rope in bore well complete all as specified and directed by Engr-in-Charge. |
| 6 | Supply and fixing fully automatic star delta starter suitable for submersible pump 10 HP capacity, having overload relay range 8.0 A to 12A complete all as specified and directed |
| 7 | Supply and fixing PVC insulated submersible cable flat type, 10 sqmm, 3 core 1100 volts grade complete all as specified and directed |
| 8 | S&F Submersible pump, electric driven 415 V, TP up to 7 HP suitable for 200/250 mm dia bore well (Casing pipe size 200/250 mm) with all accessories, fittings and hanging with nylon rope in bore well complete all as specified and directed by Engr-in-Charge. |
| 9 | Supply and fixing fully automatic star delta starter suitable for submersible pump 7 HP capacity, having overload relay range 8.0 A to 12A complete all as specified and directed |
| 10 | Supply and fixing Nylon rope twisted, Virgin Polypropylene, 10-20mm, suitable size for hanging submersible pump complete all as specified and directed |
| 11 | S&F of SMC/GRP Panel tank for water storage confirming with IS 14399:1996 (Part I & II) and IS-4249:1967 for fire retardant & NSF UK certified of 50,000 ltr capacity of size 5.00X5.00X2.00 Mtr complete including necceassary connection of all inlet, outlet pipes with pump &all other neccessary fitments requiredat site for installation on ground complete all as specified and directed by Engr-in-Charge.Note : Standard Non – Insulated SMC Panels Hot pressed moulded UV stabilized made from Sheet Moulding Compounds (SMC) composing of glass fiber and formulationSMC PANELS - Made by Hot pressed process mouldedBottom Panel - SMC Panel 1000 x1000 x 70 mm, convex shapeDrain Panel & Outlet Panels - SMC Panel 1000 x1000 x 70 mm Special design for complete drainSide panel - SMC Panel 1000 x1000 x 70 mm, 1000 x 500 x 70mmCeiling panel - SMC Panel 1000 x1000 x 70 mmManhole -SMC Panel 1000 x1000 x 70 mm with 700 mm x 700 mm locable lid.Thickness of the Panels - As per IS 14399 (Part I & II) |
| 12 | SPECIAL ACCESSORIES:Corner Frame - HDG Steel Vertical Corner Angle at Four cornersSealing Tape – Non Toxic 3mm thick with high level of resistance to ageing and superior recovery from compression (Make : Norseal by Saint Gobain)Steel Bolts for Panel Joints - HDG Nut-bolts – 8.8 Grade – M12 x 40mm – 8 nos. per sideAir Vent – PVC - Air vent dia 100mm with insect proof mesh in sideWater Level Indicators - Aluminium body level indicator – transparent tube typeExternal reinforcement - ISI marked painted C channel supports at every 1-meter except in the corner of steel with anti corrosive paint and it is tie with top external painted tie rods.Internal roof supports - FRP square hollow section for roof supports – 50x50x5mmLadders External ladder with wall mounting arrangementInternal ladder FRP (if tank height is more than 1 meter)Connection fixing - Inlet/ Outlet/ Overflow/ Drain Inlet, Outlet, overflow & drain – 50NB (as per table D – BS10)G.I. Flange type with 9” long thread and Nipple.Base frame Grillage - As per site condition, suitable for tank size and capacity. Made out from M.S. Channels/ beams with anticorrosive paints.Base frame shall be measured & paid separately under relevant items. |
| 13 | S&F of SMC/GRP Panel tank for water storage confirming with IS 14399:1996 (Part I & II) and IS-4249:1967 for fire retardant & NSF UK certified of 98,000 ltr capacity of size 7.00 X 7.00 X 2.00 Mtr complete including necceassary connection of all inlet, outlet pipes with pump &all other neccessary fitments requiredat site for installation on groud shall be part of job at no extra cost complete all as specified and directed by Engr-in-Charge.Note : Standard Non – Insulated SMC Panels Hot pressed moulded UV stabilized made from Sheet Moulding Compounds (SMC) composing of glass fiber and formulationSMC PANELS - Made by Hot pressed process mouldedBottom Panel - SMC Panel 1000 x1000 x 70 mm, convex shapeDrain Panel & Outlet Panels - SMC Panel 1000 x1000 x 70 mm Special design for complete drainSide panel - SMC Panel 1000 x1000 x 70 mm, 1000 x 500 x 70mmCeiling panel - SMC Panel 1000 x1000 x 70 mmManhole -SMC Panel 1000 x1000 x 70 mm with 700 mm x 700 mm locable lid.Thickness of the Panels - As per IS 14399 (Part I & II) |
| 14 | SPECIAL ACCESSORIES:Corner Frame - HDG Steel Vertical Corner Angle at Four cornersSealing Tape – Non Toxic 3mm thick with high level of resistance to ageing and superior recovery from compression (Make : Norseal by Saint Gobain)Steel Bolts for Panel Joints - HDG Nut-bolts – 8.8 Grade – M12 x 40mm – 8 nos. per sideAir Vent – PVC - Air vent dia 100mm with insect proof mesh in sideWater Level Indicators - Aluminium body level indicator – transparent tube typeExternal reinforcement - ISI marked painted C channel supports at every 1-meter except in the corner of steel with anti corrosive paint and it is tie with top external painted tie rods.Internal roof supports - FRP square hollow section for roof supports – 50x50x5mmLadders External ladder with wall mounting arrangementInternal ladder FRP (if tank height is more than 1 meter)Connection fixing - Inlet/ Outlet/ Overflow/ Drain Inlet, Outlet, overflow & drain – 50NB (as per table D – BS10)G.I. Flange type with 9” long thread and Nipple.Base frame Grillage - As per site condition, suitable for tank size and capacity. Made out from M.S. Channels/ beams with anticorrosive paints.Base frame shall be measured & paid separately under relevant items. |
| 15 | PCC 1:3:6 type C-2 using 40mm stone agg as in foundation, filling and mass concrete on retaining walls complete all as specified and directed by Engr-in-Charge. |
| 16 | Material and labour for providing PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in platform, filling and mass concrete, complete all as specified ansd as directed. |
| 17 | Pre-cast cement concrete hollow block masonry type 1:3;6, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L rendering 15mm thick on Brick masonary in internal surfaces in CM 1:4 finished even and smooth with sagol finishcomplete all as specified and directed. |
| 19 | M&L for preparation of plastered surfaces & applying two coat of cement base paint complete all as specified and directed by Engr in Charge. |
| 20 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core. |
| 21 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core. |
| 22 | Excavation in tranches in soft loose soil not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth for laying of pipes in tranches and getting out including levelling of bottom surface and trimming of sides after removal of existing GI/HDPE pipes and fittings complted all as specified and directed. Note rate of removal of existing GE/HDPE pipes find fitting shall be included in the above items. |
| 23 | Returning filling in including spearing levelling, waering and well ramming in layers not exceeding 25 cm thick each excavated soft/hard soil in trenches after the pipes havew been laid and tested competed all as specified and directed. |
| 24 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge |
| 25 | M&L for Sand cushioning on under ground cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as specified and directed |
| 26 | Supply and lay well burntclass ‘B’ bricks as mechanicalprotection to under ground cables laying with length of the bricks equal to the width of the trench all as specified and directed |
| 27 | M & L for Tubes, \"light grade\" 80 mm dia, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 28 | M&L for Earthing in replacement / renewal complete with galvanised steel earth plate electrode 600x600x6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised strip of size 32 x 6 mm earth continuity coductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR-I 2009, connected to main switch board all as specified. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20 mm dia GI Pipe medium grade, funnel with wire mesh and lugs, complete all as specified and directed by Engineer-in-Charge. (Earthing for LT Panel) |
| 29 | Supply, install, testing and commissioning LT cubical Panel of outdoor type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 45 cm long embedded in PCC 1:3:6 type C2 complete with aluminium bus bar ofrating 1.5 times the rated capacity of incomer, IP 65 protection, suitable cable gland for incomming and outgoing cables with lugs and connections etc required nuts ,bolts and washer incl complete control wiring with suitable size PVC copper conductor cable and provn of cable lugs etc. Including provision of following accessories/eqpt incl cable gland etc and suitable for fixing of under mentioned items:-Incommer(a) MCCB 125 A, 415 V ,4 pole with over load short circuit protection, breaking capacity 35 KA - 01(b) Multi function meter for measuring V,A,F,kW,KVAincludingCTs of suitable capacity - 01(c) LED Phase Indication lamp (RYB) - 01 Set(d) Single phase preventer(e) Water level autocut for motorOutgoing(a) MCCB 63 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 25 KA - 02(b) Wiring of above accessory with suitable size of copper conductor cable |
| 30 | S&F of MS Work as in base frame of water storage tank using channel/ girders complete all as specified & directed by Engr in charge. |