| 1 | Supplying and erecting G.I. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation |
| 2 | Making Cement concrete foundation including excavation (45 x 45 x 120)cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45)cm/ 45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (for 6m pole) |
| 3 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty |
| 4 | Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty |
| 5 | Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty |
| 6 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results |
| 7 | Supplying and erecting electronic type Driver for Outdoor LED fittings upto 46W-75W suitable to operate on 230V A.C. 50 Hz. having p.f>0.95 and THD<10% |
| 8 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. |
| 9 | Supplying, erecting & terminating PVC armoured cable 4 core10sq mm aluminium conductor withcontinuous5.48 sq mm (12 SWG) G.I. earth wire completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe |
| 10 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete |
| 11 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe |
| 12 | Supplying and erecting PVC insulated PVC round sheathed FR 2.5 sq.mm (50 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV |
| 13 | Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall alongwith DIN bar for mounting MCB |
| 14 | Excavating Hard rock or bituminous road by chiselling for preparing pit for pole/ stay/ earth plate/ for laying cable/ pipe & clearing the site by removing debris & making the site as required complete |
| 15 | Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board |
| 16 | Supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm complete |
| 17 | Supplying & erecting three phase, 415V, street light control panel upto the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation |
| 18 | Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling |
| 19 | Supplying and erecting 25mm dia. corrugated flexible polypropylene conduit |
| 20 | Supplying and erecting iron work, sheet metal work consisting of MS sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. |
| 21 | Supplying, erecting, testing & commisioning bus bar chamber triple pole with neutral with four copper bars, 500V, 100A having 10mm ( width) x 1.6 mm (thickness), with 99.9 % copper purity as per E91E grade & current density 1.6 A per sq mm compliance to IS 5082 and enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC insulators and accessories of suitable rating and two nos of separate earthing terminals complete |
| 22 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board |
| 23 | Supplying, erecting & marking DP MCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board |
| 24 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB/TP MCB /FPMCB/ RCCB/ RCBO complete erected on provided angle iron/GI frame. |
| 25 | Painting of pipe pole upto 6 m length along with street light / pole brackets / clamps etc by scrapping the existing paint complete. |
| 26 | Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6 m in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads |
| 27 | Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places |
| 28 | Supplying and erecting acrylic sheet 3 mm thick for covering wall entries including cutting, drilling and fixing with nut bolts / screws etc. complete. |