Heavy Industries and Public Enterprises Government Departments Closing in 0 days TDR #49034001

Tender For Upgradation Of Street Light And High Mast System With 03 Years Amc At I.A. Panki Site-4 Kanpur City

Issued by Government Departments · panki, Uttar Pradesh
Tender Value
73.70 Lakhs
Estimated cost
Bid Submission
04 Jun 2025
0 days left
EMD
1.74 Lakhs
Bank guarantee accepted
Document Fee
3387
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
panki → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Upgradation Of Street Light And High Mast System With 03 Years Amc At I.A. Panki Site-4 Kanpur City

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 28-May-2025 Extension of Date Date 04-Jun-2025

BOQ

Name of Work: Upgradation ofStreet light & High Mast system with 3 years AMC at IA Panki Site 4 Kanpur City
Sl. No. Item Description
1Supply and fixing of LED Street light fitting having die cast aluminium body and diffuser with driver set suitable for 120 watt confirming to IP 66 protection complete in all respects (With 5 Year Gaurantee(3+2) . Catt. AA as per UPPWD Sch. No.1424 (Bajaj /Philips/Crompton/Wipro Make)
2Supply & Fixing of 32 MM Dia 1.20 Mtr long G.I Pipe Bracket For Fixing of LED lights complete in all respects with clamp etc.
3Supply & fixing of as per Design Suitable for Fixing Shackle Insulator , Made out of size 50x6 mm M.S.flat Including all bolts with nuts and washers etc. complete in all respect as per UPSIDC Sch. No. 13.1
4Supply & fixing of 100 x 110 mm shackle insulator 100 x 80 mm pin insulator including GI volt spindle, nuts etc. as pre UPPWD Sch. No. 621
5Supply, sagging, jointing and binding of insulated ACSR Weasel conductor including cost of aluminium tape binding and jointing sleaves etc. complete in all respect.
6Supply, sagging, of GI wire 6 SWGon ST Pole For Earth Wire. complete in all respect rate as perUPSIDC Sch. No. 11
7Supply & wiring of submain with 2 Nos. of 2.5 sqmm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cables in existing conduit complete with supply of all material labour and T&P required for proper complation of the work as directed as site byEngineer I/C as Per UPPWD sch No. 289(Polycab /KEI/ Havells/ Grandley/Gloster Make )
8Supply & laying 35 sq mm 3.5 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V garade in existing HDPE pipe laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(k) & 507 (Polycab /KEI/ Havells/ Grandley/Gloster Make)
9S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connectedwith the earth as per direction of Engineer-incharge as per UPPWD sch. no. 503 (k) 35 sq. mm 3.5 core
10S/F of palm or pin type copper tin plated cablesocket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (f) 35 sq. mm
11S/F of following capacity of automatic street light cubical cantrol panel painted with anti corrosive alkali and acid proof paint consisting of timer switch TSO 100 / Digital with ML-4 Contractors HRC fuses, isolating switch metering instuments box with CTS etc. as per UPPWD Sch. No. 807(f-ii) (40 Amp. TPN)
12Supply and fixing 25amp.TPN Capacity of Automatic street light cubicle control panel painted with Anti corosive alkali and acid proof paint, consisting of time switch TSO 100 serices/ Digital with ML-4 Contractor, HRC Fuses Isolating switch, metering Instrument & Instrument box with C.T. etc. Complete in all respect\"s.as per UPPWD Sch. No.807(f)(ii)
13Strengthening of ST/Octogonal pole/High Mast/Panel, foundation by providing new concreting including broken of weak foundation,excavation below upto Ground level,Surface finishing and painting with white cement and dark yellow colour cost of all material men and T&P complete in all respect.
14Painting of ST pole and all mountings on it with two coats of aluminium paints with an under coat of red oxide paint upto10 M. support above the ground level as per direction of Engineer in-charge of work/site including T&P , men & material required for proper completion of work.UPSIDC Sch. No.24.20.(A)
15Painting letters (Pole no.) 2.5 cm upto 8.0 cm size complete on street light pole/panel/other electrical properties under UPSIDA including cost of all material men and T&P complete in all respect.
16Supply&Fixxing of of UPSIDA LOGO Plate (Retro-reflective) on High Mast including cost of clamp nut & bolts all material men and T&P complete in all respect.
17Supply and fixing of 200 watt factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for confirming to IP 66 protection complete in all respects. Make as per direction of the Engineer- incharge Catt. AA as per UPPWD Sch. No.1455 (Bajaj, crompton, Philips, Wipro Make)
18Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. make as per direction of the Engineer- incharge as per UPPWD Sch. No.652, (Bajaj, crompton, Philips, Wipro Make)
19Dismantling & re-grouting of Street light 12 Tilt/sick bend/STP pole in 1:3:6 ratio cement concrete with stone pad including stranthening of pole by providing additional 04 nnos. Support of 65X65X6mm or higher size MS angle in suitable length with the help of welding/cutting as per tecnical specification.
20Tree Branches Triming for removing dark spots including cost of all material men and T&P complete in all respect.
21Supply laying and Fixing 50 dia Gi pipe trench less Through manual Boggi including trenching 90 C.M. dccp and refilling etc.Ann-2
22supply & Fixing of LED light strip with off-white colour light complete with driver etc.complete in all respect . warranty one years, ( Philips, Bajaj, Crompton, Wipro Make)
23Fabrication,Supply & Fixxing of work information board in M.S frame made by 50 mm dia sqaure pipe of stainless steel grade SS-304 &16 mm thick base plate with back supporting of bracing by MS flat of 25x6 mm and 2.85 Mtr. Long supporting leg made from 65mm pipe SS-304 grade with proper grouting arrangement. The board should be Retro reflective type in green colour with white letters as required and shall be fixed at a height of 1.2 Mtr. from ground by providing 0.45x0.45x0.60 Mtr. cement concrete stone pad
24(AMC)Supply & laying 16 sq mm 2 core Al. conductor PVC insulated armoured, served, sheathed cable 1100 V grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand alround and protected with burnt brickson sides ant top. On surface the cable run shall be fixed on MS clamps of suitable size or as directed by Engineer in-charge. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501(c)(Polycab /KEI/ Havells/ Grandlay/Gloster Make)
25S/F of brass nickel Plated compression gland for PVC insulated and armoured served sheated ,underground cable including rubber ring etc. comlete in all respects.the armouring of the cable shall be properly connectedwith the earth as per direction of Engineer - incharge as per UPPWD sch. no. 503 (c) 16 sq. mm 2 core
26S/F of palm or pin type copper tin plated cablesocket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (d) 16 sq. mm
27Dismantling & re-grouting of street light 12 tilt/sick bend/STP pole in 1:3:6 ratio cement concrete with stone pad including strengthening of pole by providing additional 04 nos sopports of 65x65x6 mm or higher size MS angle in suitable length with the help of welding /cutting as per technical specification
28Supply and laying of 25 mm x 3mm G.I. strip from earth electrode directly in the ground as required respects as per UPPWD Sch. No. 716
29Charges for maintenance ,proper watch and ward of entire electrical system of Street Light and High Mast Tower,cables,conductors,poles,panels etc and all other available material as per direction of engineer in charge for road lightng in IA to cover the general supervision for execution of work including dismantling and re fixing of all street light of UPSIDA during the period of AMC for 3 years(01 Helper+1 Electrician ) as per approvedrate of UPSIDA
30Cost of all material, spares wire fuses,small accessories required for general maint.,cleaning,oiling etc.to keep the entire installation in perfect working order during AMC period complete in all respect.
31Supply & fixing of driver suitable for 70 to 110 watt LED street light fittings as per make installed at Site complete in all respect
32Supply & fixing of MCPCB with LED & Lance ( 70 to 110 watt) for suitable installed LED street light fittings complete in all respect .
33Supply & Fixing of Glass suitable for installed LED street light fittings complete with rubber gasket etc. complete in all respect .
34Supply & fixing of LDR suitable for installed LED street light fittings complete in all respect.
35Supply & fixing of special protection device (SPD) suitable for 70 to 110 watt LED street light fittings as per make installed at Site complete in all respect.
36Dismantaling & Re- Fixing of LED Street Light / Flood Light For Repairing UPPWD 1455
37S/F of ML-4 contactor MDS/L&T make complete including all T&P man and material required for proper completion of work.
38S/F of mounting time switch (timer clock) L&T/MDS make complete including all T&P men and material required for proper completion of work.
39Supply and making straight through joint with cast resin compound including ferrules and other joints materials for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor 16 sq.mm 2 core cable of 1100 v grade complete.

AI Tender Summary

OUR REF NO 49034001
AUTHORITY Government Departments
TENDER VALUE 73.70 Lakhs
LAST DATE 04-06-2025
Authority
Authority Name Uttar Pradesh State Industrial Development Corporation Limited
Work Description Upgradation Of Street Light And High Mast System With 03 Years Amc At I.A. Panki Site-4 Kanpur City
Basic Detail
Tender No ED_IV_23_15042025
Bidding Type Tender
Location
City panki
State Uttar Pradesh
Key Dates
Publish Date 28 May 2025
Submission Date 04 Jun 2025
Open Date 05 Jun 2025
Finance
Tender Value 73.70 Lakhs
Tender Fee 3387
EMD 1.74 Lakhs
Exemption Not Available
Document List
b68ef10f-75f0-4449-9905-827606790b4c.html
Amcgeneraltermsandconditi_1.pdf
BOQ_1878154.xls
etenderdocuments.pdf
FEEFORMAT.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 28, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 04, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 04, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 05, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b68ef10f-75f0-4449-9905-827606790b4c.html

pdf

Amcgeneraltermsandconditi_1.pdf

xls

BOQ_1878154.xls

pdf

etenderdocuments.pdf

xls

FEEFORMAT.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders