| 1 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kind of soil |
| 3 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 4 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering,shuttering,finishingandreinforcement-All workuptoplinthlevel:1:1.5:3(1cement:1.5coarse sand : 3 graded stone aggregate 20 mm nominal size) (beams up to Plinth Level) |
| 5 | Reinforcedcementconcreteworkinbeams,suspended floors,roofshavingslopeupto15°landings,balconies, shelves,chajjas,lintels,bands,plainwindowsills, staircasesandspiral staircasesaboveplinthlevel , upto floorfivelevel,excludingthecostofcentering, shuttering, finishingandreinforcementwith aggregate 20 1:1.5:3(1 cement : 1.5 coarse sand : 3 graded stonemm nominal size ). (beams above to Plinth Level) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering,shuttering,finishingandreinforcement-All workuptoplinthlevel:1:1.5:3(1cement:1.5coarse sand : 3 graded stone aggregate 20 mm nominal size) (Columns up to Plinth Level) |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering,finishing and reinforcement : 1:1.5:3 (1 cement : 1.5coarse sand : 3 graded stone Aggregate 20 mm nominal size) (Columns above Plinth level) |
| 8 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricksofclassdesignation7.5infoundationandplinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Brick work with common burnt clay F.P.S. (non modular) bricksofclassdesignation7.5insuperstructureabove plinth level up to floorV level in all shapes andsizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 11 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand. |
| 12 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 13 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 14 | angle iron 40*40*6 mm.Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. ) |
| 15 | Painting or Vanishing two coat on iron work in small areas or new wood work with one coat of ready mixed priming paint and one coat of approved superior ready mixed paint of clear synthetic varnish including supply of all materials, labour, T & P etc. required for proper completion the work. Paint to be used should confirm to the I.S.I. No. 103 1950. |
| 16 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metrelength, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for:Beams,Plinth beams |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for:Columns |