Tender For Renovation Of Existing Buildings At- Resham Nideshalay , Lucknow Uttar Pradesh
Tender Overview
Project Description
Renovation Of Existing Buildings At- Resham Nideshalay , Lucknow Uttar Pradesh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-May-2025 | DATE EXTEND | Date | 21-May-2025 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 2 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete, excluding cost of form- work,in foundation and floors. |
| 3 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.R.C.C. work Upto plinth Lvl.(M-25) |
| 4 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.R.C.C. work Above plinth Lvl.(M-25) |
| 5 | Providing and fixing roofing consist of 0.8 mm thick galvanized steel deck sheet confirming to IS 277:1992 used as permanent shuttering over which MS wire mesh 3 mm laid at 100x100 mm grid including edge trim covered with concrete. This metal deck will be supported on structural steel beam with shear studs. (Structural steel like Beam, column, joists etc. & concrete of different grade as per design will be paid separately |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Providing and laying vitrified floor tiles of size 1200x1200 mm (make: Simplo, Kajaria, or equivalent as approved), having water absorption less than 0.08% and conforming to IS:15622, in approved shades and colours. The tiles shall be laid over a 20 mm thick cement mortar bed in the proportion of 1:4 (1 part cement : 4 parts coarse sand), with grey cement slurry applied at the rate of 3.3 kg/sqm for proper adhesion. Joints shall be filled and grouted with white cement mixed with matching pigments to ensure a seamless and uniform finish. The work shall be executed with precision and in accordance with the manufacturer\"s recommendations and the instructions of the Architect, including proper alignment, level, and finish, complete in all respects. |
| 8 | 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone |
| 9 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes |
| 10 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 11 | DOUBLE SKIN ROOF SHEETING Providing & fixing Top layer of LYSAGHT Trapezoidal TRIMDEK profile sheet of 1015 mm effective cover width and nominal28.5mmdeepribswithsubtlesquare fluting in the five pans at nominal 200 mm centre to-centre. The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The feed material is manufactured out of nominal 0.50 mm Total Coated Thickness (TCT), Hi-Tensile steel with min. 550 mpa yield strength, metallic hot dip coated with Aluminum-Zinc alloy (55% Aluminum, 45% Zinc) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides). Thereafter providing sub girt in 0.5 mm thicknessin Z shape of 50 mm web and 20 mm flange overbottom skin sheet shall bePanel rib profile of LYSAGHT to be installed over purlins directly with self drilling & tapping screws. to make air gap of 50 mm for providing sandwich insulation of 50 mm thick rock wool pads having density of 48 kg/mtr cube with HDPE vapor liners on both top and bottom surface of Rock wool. Complete job with all hardware, accessories, material and labour. |
| 12 | Providing and fixing in position factory made non asbestos fibre reinforced aerated cement sandwich wall/roof/floor light weight solid core panels made of light weight cement concrete core composed of OPC cement, pulverized flyash, quick lime, cotton pulp & Gypsum in mortar state mixed with aeration agent in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board Type B , cate - III confirming to IS 14862:2000. These solid wall panels are installed using Galvanized iron steel tracks/C channel of 1mm thick of required sizes as recommended by manufacturer\"s and fixed to floor and RCC soffit in plumb to each other with steel screw/fasteners. The panel shall be fixed vertically with tongue & groove joint with cement based polymer modified jointing compound. The exposed surface finished with fibre mesh/glass fibre tape with polymer based jointing compound having superior flexibility. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge (Cost of all the material is included except tracks/C channel\" which will be paid separately)\" |
| 13 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 14 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 15 | Providing and fixing stainless steel handles with screws etc. complete for 600mm long(Make : Ozone/Saint Gobain/Emerald) |
| 16 | Providing and fixing Ozone make lock for toughened glass including cost of material labour etc complete.(Make : Ozone/Saint Gobain/Emerald) |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 18 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 19 | Suspended floors, roofs, landings, balconies and access platform |
| 20 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 21 | Interior Work |
| 22 | Providing and fixing 75 mm overall thickness partition up to ceiling height consisting of G.I. frame with top cover of 12 mm commercial ply conforming to BWR grade of Greenply/Century ply or similar makes on both side with edge profiles, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diametermeter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm diameterbolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and or ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing. Inclusive of all - fixtures, fittings, hardware, hanging system, electrical, mechanical or any other mechanism required to make it functional. |
| 23 | Provding and fixingMetal partition ofCNC 4-8mm MS Plate Fixed in a 50mm thk. Orginal second class Teak wood frame with finish of Physical Vapor Decomposition coating , design as per drawing and approval of architect in charge. |
| 24 | P& F full ht\" Storage racks for Saree Display of 40mm thk. Teak wood supported in 40x10mm SS Flat with Decorated wooden buttress and with polyutherene polish over teak woodwith back panelling of banana craft jali andfinished design as per drawing and approval of architect in charge (C-4) |
| 25 | P& F Full Ht\" Hanging Display of MS pipe of 10mm with the finish of Physical Vapour Decomposed Coating with bending and welding design as per drawing and approval of architect in charge. (C-11) (Bluearch/Artisan or equivalent) |
| 26 | P & Flow height wooden storage of 18 mm thickness with 40mm thk Magnifera wood shutters with 8mm deepbrass inlay work inspired by the tarkashi Art of Mainpuri design as per drawing and approval of architect in charge .(C-9) |
| 27 | Providing and Finishing wall with Stucco Texture paint (Terracotta Finish ) (WF-2) (Asian/Nerolac/Berger or Equivalent) |
| 28 | Providing and finishing Artistic Paint should be of high-quality, eco-friendly, water-based acrylic or enamel paints, suitable for both interior and exterior applications. It will be hand-painted or stenciled using high-pigment paints for vibrant finishes, with options for texture effects such as marbling or glazing. Custom color mixing is required to match the design palette, and specialty finishes like metallic, pearl, satin, or textured effects will be incorporated as per the design. A protective clear coat will be applied to seal the design and provide long-lasting durability, ensuring resistance to UV exposure, moisture, and wear. Paints used should be non-toxic, low in VOCs, and comply with environmental safety standards. A minimum 5-year warranty against fading, cracking, or peeling is required, along with detailed maintenance instructions. All paints and finishes must be pre-approved by the project architect, with samples and mock-ups provided to test color and finish quality. |
| 29 | Providing and fixing false ceiling at 900mm from slab level ; maintain clear height of 4350mm from FFL including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm diameterx 50mm long with 6mm diameterbolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm diameterx 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint , all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cut-outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum moisture resistant plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks)Inclusive of all - fixtures, fittings, hardware, |
| 30 | Providing and fixing of wooden louvered parametric false ceiling comprising sectional members of size 40 mm x 150 mm, fabricated from seasoned hardwood or BWP plywood as per design. The louvers shall be cut and shaped to achieve the desired parametric profile and fixed securely to a suspended MS framework or wooden grid, duly treated with anti-corrosion/anti-termite coating. All exposed surfaces shall be sanded, finished, and polished with melamine or PU polish in approved shade. Installation shall be carried out as per approved design, pattern, and instructions of the Architect, ensuring proper alignment, spacing, and overall finish. |
| 31 | Proving and installation of Wooden deck with 19mm board (Century / Green or equivalent),1mm laminated & 12mm rubber wood alldesign as per drawing and approval of architect in charge. |
| 32 | Providing and Fixing of Billing counter 750/1100 high with curvilinear wooden tops andglass mountingSize 2400*1100 as per drawing with 4mm Veneer over 19 mm Ply water Proof. Plywood conforming to international formaldehyde emission standards)and post formed edges finished and duly Melamine/ PU polished on outer surface and inner surface finished with micaapproved by the Architect, with mobile storage unit and wire management. |
| 33 | Providing and fixing of 900 mm high display table of size 1800mm x 900mm with curvilinear louvred and flat wooden tops, made from 19 mm BWP plywood conforming to international formaldehyde emission standards, finished with 4 mm decorative veneer and post-formed edges. Outer surfaces to be melamine/PU polished and inner surfaces finished with 1mm thick approved mica. The table shall include a concealed hardwood/MS frame, integrated mobile storage units with branded hardware (Hettich/Häfele or equivalent), and wire management provisions. All work to be done as per approved design and instructions of the Architect. |
| 34 | Café Chairs (kkita – Teakwood Dining / Arm Chair with Shadow Grey Fabric) (Geeken/Godrej or Equivalent) |
| 35 | Vinyl print with Installation - Providing & Fixing Printed Vinyl Graphics on Punned or Levelled Surface of (3M or Equivalent) ,overPlywood /MDF or Laminate. Cost to include cleaningfor any stains, scffolding for height upto 8000mm from FFLApproved Make - 3M, LG, Avery/Equivalent |
| 36 | Providing and Fabrication of Powder coated stucture with base like spec stand Polycarbonate / Corian printed graphic Translation Works - English text will be provided by the client. Hindi and Punjabi translation to be done. |
| 37 | Providing & Fixing of Signage/Graphics for all floors (BlueArch/Arstisan or Equivalent) |
| 38 | Visual Design, graphics, branding, Wayfinding and graphics for Retail store(BlueArch/Arstisan or Equivalent) |
| 39 | Providing & fixing of parametric front facade including Fabrication, Hoisting and Installation ofSign Board on Front Façade complete with all accessories(BlueArch/Arstisan or Equivalent) |
| 40 | P & F of laser cut logo on rear wall with back lighting (1M X 1 M) and acrylic letters with alumnium casingon front Wall /Café Counter as per drawing and approval of architect in charge etc all complete in direction of Architect / Engineer in charge. (BlueArch/Arstisan or Equivalent) |
| 41 | CCTV and Security |
| 42 | Electrification Work |
| 43 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 44 | Group - C |
| 45 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 46 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 47 | 20mm dia PVC conduit |
| 48 | 25mm dia PVC conduit |
| 49 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 50 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 51 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 52 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 53 | 2 X 6 sq. mm + 1 X 4 sq. mm earth wire |
| 54 | 4 x 6 sq.mm + 2 x 6sq.mm. earth wire |
| 55 | 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire |
| 56 | 4 x 16 sq.mm + 2 x 6sq.mm. earth wire |
| 57 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 58 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 59 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 60 | Providing and Fixing 6 SWG dia G.I. Wire on surface or in recess for connection etc. as required. |
| 61 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 62 | Single pole |
| 63 | Triple pole and neutral |
| 64 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 65 | 8 way Double door |
| 66 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 67 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 68 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 69 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |
| 70 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 71 | Upto 450 mm sweep |
| 72 | Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. |
| 73 | PROVIDING AND FIXING CIRCULAR/ HEXAGONAL G.I. BOX FORCEILING FAN CLAMP, OF INTERNAL DIA 140 MM, 73 MMHEIGHT, TOP LID OF 1.5 MM THICK G.I. SHEET WITH ITS TOPSURFACE HACKED FOR PROPER BONDING, TOP LID SHALL BESCREWED INTO THE G.I. BOX BY MEANS OF 3.3 MM DIA ROUNDHEADED SCREWS, ONE LOCK AT THE CORNERS. CLAMP SHALLBE MADE OF 12 MM DIA M.S. BAR BENT TO SHAPE AS PERSTANDARD DRAWING |
| 74 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan |
| 75 | Supplying and drawing following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. |
| 76 | 2 Pair |
| 77 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 78 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. |
| 79 | Telephone socket outlet |
| 80 | TV antenna socket outlet |
| 81 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 82 | 75mm X 75 mm X 60mm Deep |
| 83 | Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. |
| 84 | 1 or 2 Module (75mm X 75 mm) |
| 85 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 86 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 87 | 1 run of cable |
| 88 | Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 89 | Above 185 sq.mm. and up to 400 sq.mm. |
| 90 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 91 | Up to 35 sq.mm. |
| 92 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required |
| 93 | Above 185 sq.mm. and up to 400 sq.mm. |
| 94 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required |
| 95 | Upto 35 sq. mm (clamped with 1mm thick saddle |
| 96 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 97 | Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. |
| 98 | 2 X 6 sq. mm (19mm) |
| 99 | 3½ X 240 sq. mm (62mm) |
| 100 | 4 X 10 sq. mm (25mm) |
| 101 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 102 | 100mm dia |
| 103 | 150 mm dia |
| 104 | PART C - NON - SCHEDULED ITEMS (AS PER MARKET RATES ) |
| 105 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. |
| 106 | Telephone socket outlet |
| 107 | LED Track Light Leander-10W(Black,4000K) LED Track Lights(DL01-10083) (Philips/Panasoni or Equivalent) |
| 108 | Uranus-1 Meter Black LED Track (TR01-10002) (Philips/Panasoni or Equivalent) |
| 109 | Black LED Track straight connector (TR01-10006) (Philips/Panasoni or Equivalent) |
| 110 | Track Suspension Kit(TR01-10013) (Philips/Panasoni or Equivalent) |
| 111 | Surface LED Revolving COB Downlights (DL01-10142) Stratosphere -10W(Black/Gold, 4000K) (Philips/Panasoni or Equivalent) |
| 112 | Wall Light (Ten spot) (Philips/Panasoni or Equivalent) |
| 113 | Pendant Light (Peacemaker Large(Built-in- LED) (Philips/Panasoni or Equivalent) |
| 114 | Supplyof AC 230/250 Volts, 50 Hz 60 w 1325 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO L.D. JET DLX(Philips/Panasoni or Equivalent) |
| 115 | 300mm sweep. |
| 116 | Supply and Laying of 2 Core 1.5Sqm. Copper Cable (Philips/Panasoni or Equivalent) |
| 117 | Supply and fixing of 40 Amp. 4 Pole MCB (10KA)(Philips/Panasoni or Equivalent) |
| 118 | S&F of 100 Amp 4 pole MCB (10 KA) (Philips/Panasoni or Equivalent) |
| 119 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required.(Philips/Panasoni or Equivalent) |
| 120 | RJ-45 Jack With Cat 6 -2M |
| 121 | Supplying telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required.(Philips/Panasoni or Equivalent) |
| 122 | 10 Pair |
| 123 | S/f of 10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same (Philips/Panasoni or Equivalent) |
| 124 | Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment (Philips/Panasoni or Equivalent) |
| 125 | 3.5 x 240 sq.mm. |
| 126 | 4 x 10 sq.mm |
| 127 | 2 x 6 sq.mm, |
| 128 | SPLIT AC |
| 129 | Supply & Installation of split direct expansion air conditioners suitable for operation on AC supply single phase 50Hz 230 V with hermetiaclly sealed compressor, with air colled condenser with DCinverter technology, motor capacitor and start run capacitors,relay and over load protection unit,with one indoor and outdoor unit wiil be plaved outside the room on the tessace to avoid noise including standard lenght of suitable size copper tubing covered with insulation tube ( High wall chorded/cordless) suitable capacity 3 Core sheathed /PVC copper cable and a operated wireless remote unit |
| 130 | 1.5 TR. |
| 131 | Supply & installation testing commissioningof Voltage Stabilizer Complete in all respect. |
| 132 | Supply.installation testingandcommissioning of interconnecting high pressure copper refrigerant piping work suitable for refrigerant R 410A duly insulated with elastomeric nitrile rubber type tubular insulation of density 55+/- 10% Kg/m3 betweenindoor & outdoor units as per specifications. |
| 133 | 12.7 mm O.D. (Min. Wall Thickness- 0.80 mm. insulation -13 mm thick) |
| 134 | 6.4 mm O.D. (Min. Wall Thickness- 0.80 mm, insulation- 13 mm thick) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender