| 1 | Taking down carefully copper / aluminium point wiring (light / fan/ socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfacesall as specified and directed. |
| 2 | Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of same size ie.1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and drawing into existingconduit and replacement of modular metal flush box of suitable size with modular white cover plate, frame, blanking plate etc as reqd at site and making good the disturbed surfaces to match with the existing complete all as specified and directed for one light point controlled by one, one way switch 06 Amps complete all as specified and directed. |
| 3 | All as per the description of serial item No 02 here-in-before but for one bell point controlled by one bell push switch 06 Amps. |
| 4 | All as perthe description of serial item No 02 here-in-before but for one ceiling / Exhaust fan point controlled by one, one way switch 06 Amps. |
| 5 | All as perthe description of serial item No 02 here-in-before but for one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch. |
| 6 | All as perthe description ofserial item No 02 here-in-before but for one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch. |
| 7 | All as perthe description ofserial Item No 02 above but for point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sqmm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 8 | Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of same size ie.1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box of suitable size with modular white cover plate, frame, blanking plate etc as reqd at site and making good the disturbed surfaces complete all as specified and directed for one light point controlled by one, one way switch 06 Amps complete all as specified and directed. |
| 9 | All as per the description of serial item No 08 here-in-before but for one bell point controlled by one bell push switch 06 Amps. |
| 10 | All as per the description of serial item No 08 here-in-before but for one ceiling / Exhaust fan point controlled by one, one way switch 06 Amps. |
| 11 | All as per the description of serial item No 08 here-in-before but for one 3 pin, 06 amps socket outlet point on independent board controlled by one, one way 06 Amps switch. |
| 12 | All as per the description of serial item No 08 here-in-before but for one 3 pin, 06 amps socket outlet point on same board controlled by one, one way 06 Amps switch. |
| 13 | All as per the description of Serial Item No 08 above but for point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sqmm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 14 | Supply and fixing modular switch, 06 amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed. |
| 15 | Supply and fixing modular bell push with indicator, 06 amps, single pole, one way, 230 volts,complete all as specified & directed. |
| 16 | Supply and fixing modular switch, with indicator, 16 amps, single pole, one way, 230 volts, one module complete all as specified & directed. |
| 17 | Supply and fixing modular socket outlet 05 Pin, 06 amps, 02 module with shutter complete all as specified & directed. |
| 18 | Supply and fixing modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 amps, 02 module with shutter complete all as specified & directed. |
| 19 | Supply and fixingding dong bell, AC, 230 volts, single pole complete all as specified & directed. |
| 20 | Supply and fixing ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts, duly ISI marked complete all as specified & directed. |
| 21 | Supply and fixingceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm sizecomplete all as specified & directed. |
| 22 | Supply and fixingin replacement lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 9W LED bulbcomplete all as specified & directed. Note for item no 14 to 22. |
| 23 | Supply and fixing in replacement decorative wall mounting,fixture with opal PC diffuser suitable for 10/12 watt LED Lamp, lamp holder, including 12 Watts LED bulb of 6500 K , and all accessories pre-wired including connecting up complete all as specified and directed. |
| 24 | Supply and fixing in replacementsurface and wall mounted LED batten 10 watt 2 feet longextruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drivesuitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed. |
| 25 | Supply and fixingin replacementsurface and wall mountedLED batten with polycarbonate housing and initigarated electronic drive 20 Watt fixture 4 feet provided for efficient heat dissipation with policorbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete all as specified and directed. |
| 26 | Supply and fixing in replacementgarden light fitting 18 watts,rated LED, alluminium lighting fixture, Acrylic Defuser, stanless steel screws, corrosion & UV RAys Reasitant coatting. Bollard light with and including of brick/PCC work all as requad at side but not less than in size as directed by GE |
| 27 | Supply and fixing in replacementgarden light fitting 9/12 watts,rated LED, alluminium housing, powder coated, PMMA Diffuser. with and including of brick/PCC work all as required at site but not less than in size as directed by Engr.in Charge. |
| 28 | Supply and fixing in replacementLED post top lantern with die cast aluminiumlighting fixture, polycarbonate diffuser, sillicon rubber gaskat, stainless steel screws, corrosion and UV rays resistant coating and IP 65/66 with andincludingall fixing and connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections complete all as specified and directed. |
| 29 | Supply and fixing in replacementLED post top lantern with die cast aluminium spigot spun aluminium powder coated top cover aluminium clear acrylic and IP 65/66 with and including all fixing arrangment and connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections complete all as specified and directed. |
| 30 | Supply and fixing in replacement of size 6/8 inches dia and up to 18 Volt round LED panel recess/surface mountingdownlight in CDL with integrated driver to delivered superior light output and uniformity utilising the latestLED technology, ceiling cutout 145mmmm dia hight max 35mmrecess luuminaries all as specified and directed. |
| 31 | Supply and fixing in replacementLED flood light 120 watt 230 watt AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection, with impact and corrosion resistant complete with driver and lamp. and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete. all as specified and directed |
| 32 | Supply and fixing in replacementLED luminaire 600mm x 600mm, 35/36 watt, 220 volt AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size with connector block complete all as specified and directed. |
| 33 | Supply and fixing in replacementenergy saving LED security light fittingof 45 watts versatile pressure die-cast aluminium houseing IP65/ 66 with high power LED as light source comprising with electronic driver and all accessories pre-wired with and incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and suitable GIbracket for mounting of light fitting, bend to shapeand fixed to wall by means of suitableflat iron clamps, nuts, bolts and washers etc complete all as specified and directed. |
| 34 | Supply and fixing in replacementventilating fan wall mounted type of 250mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by GE. |
| 35 | Supply and fixing in replacementventilating fan wall mounted type of 200mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by GE. |
| 36 | Supply and fixing in replacementwall mounted fan of 400mm sweep, 230 volts, AC, 50 Hz capacity, including all arrangements for mounting of fan with and including connecting up with provision of PVC insulated flexiblecopper conductor cable 1.5 Sqmm, 2 core as required for connections complete all as pecified and as directed. |
| 37 | Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 4 Sqmm copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25mm dia, medium grade or higer with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces complete all as specified & directed, including taking down old sub main wiring. Note:- Two run for neutral and phase and one run for continuous eart wire for earthing shall be measured as one unit. |
| 38 | All as per the description of srl item No 37 here in beforebut 06 sqmm nominal cross sectional area, |
| 39 | All as per the description of srl item No 37 here in beforebut 10 sqmm nominal cross sectional area, |
| 40 | Supply and fixing in replacementindustrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, \"C\" curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. |
| 41 | Supply and fixing in replacementsheet metal enclosure distribution board, duble door type single pole and neutral, AC, 230 volts, 08 way, with 200 amps rated copper bus barwith IP - 43 & IK 09 protection along with cable end boxand flush to wall including all cutting etc in wall and making good to the disturbed surfaces complete all as specified directed. |
| 42 | S&F (in replacement) sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 415 volts, 04 ways with 200 amps rated copper bus bar and metal double door suitable for MCCB 125 amps as incomer and MCB SP as outgoing along with cable end boxand flush to wall including all cutting etc in wall and making good to the disturbed surfaces complete Note :- MCCB & MCB SP will be measured seperately |
| 43 | Supply and fixing in replacementMCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete all as specified & directed. |
| 44 | Supply and fixing in replacement240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning by using suitable copper lugs complete all as specified and drected. |
| 45 | SP 5 to 32 Amps |
| 46 | SPN 40 to 63 Amps |
| 47 | Supply and fixing in replacementMCB, TPN , AC, 415 volts of 40/63amps capacity \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. |
| 48 | Supply and fixing in replacement40 amps 4 Pole30mm RCD add on block 10 KA rated conditional short circuit current (Icc) 35 sqmm terminals, dual position DIN Clip, confirming to IEC 60947-2 and 40 Amps 4 pole\"C\" type MCB confirming to IS/CE Marked as per IS/IEC60898-1, rated short circuit breaking capacity Icn 10 KA, enerergy limitation class 3, line load reversiblity, 35 sqmm terminals, biconnect terminals all as specified and directed by Engr-in-charge. |
| 49 | Supply and fixing in replacementexhaust fan, steel body, AC, single phase, 230 V of size 300mm sweep complete with blades, frame & louver having 1400 RPM speed, 1600 CMHincluding making of holes of suitable size and taking down old exhaust fan and depositing to MES store yard making good to the disturbed surfaces completeall as specified and directed. |
| 50 | Supply and fixing in replacement, Installation, Testing and Commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with brush less Direct Current (BLDC) Motor, class of insulation: B, 3 Nos. blades, 30cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete and taking down old/unserviceable fan and deposit in E/M store yard complete all as specified and directed |
| 51 | Supply and fixing in replacementLED cast iron base pole, of 3m height with die cast aluminiumlighting fixture, polycarbonate diffuser, sillicon rubber gaskat, stainless steel screws, corrosion and UV rays resistant coating and IP 65/66 including of brick/PCC workas vecommended by the manufacturer allasspecified and directed and connecting up with and includingprovision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections complete all as specified and directed. |
| 52 | Supply and fix electric water heater, storage type 25 ltrs capacity, BEE star rated, vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode having adustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minium two year warranty on product, minimum three years on heating element complete all as specified and as directed. |
| 53 | Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cm x 60cm x 6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 4.0mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part-I (2009) and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mm x 40mm x 3mm frame for pit cover including testing on completion complete all as specified and directed. Note:- On testing after completion if desired earth resistance is not obtained, the earlting will be redone at no extra cost. |
| 54 | S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed. |