| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge (2.6.1 of DSR 1997) |
| 2 | Filling available excavated earth ( excluding rocks) in plinth side of foundation, under floors in layers not exceeding 20 cm in depthincluding, watering, ramming consolidating and dressing completelead up to 50 m and lift up to 1.5 m. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level.1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level.1:5:10 (1 Cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and fixing up to floor five level precast cement concrete solid block,including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete :1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarsesand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings and bases for columns. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars |
| 12 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) with local wood |
| 13 | Providing wood work in frames of false ceiling, partition and other frames fixed in positionlocal wood |
| 14 | Providing and fixing panelled or panelled and glazed shutters doors, windows and clerestory windows including ISI marked black enameled M.S. butt hinges with necessary screws (screws should be of stainlesss steel and brand Magnum/ Nettlefold/Amul) excluding, panelling which will be paid for seperately (Thickness of shutters should be 35mm) |
| 15 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 16 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws; 30 mm thick shutters: With ISI marked M.S. pressed butt hinges of required size: First class local wood (Tita champa/Pine/tiger) |
| 17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. complete. |
| 18 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than gradeAC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :250x16 mm |
| 19 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10mm |
| 20 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :100x10mm |
| 21 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :Size 125mm |
| 22 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :Size 100 mm |
| 23 | Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 24 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. |
| 25 | Provided & fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-charge) 0.50 mm +/- 5% total coated 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of thickness (TCT), Zinc coating 120gsm as per IS:the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or withpolymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 26 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Ridges plain (500 - 600mm) |
| 27 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 28 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 29 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two or More Coat |
| 30 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 31 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
| 32 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 33 | P/F 8mm dia C.P/S.S. Jet with flexible tube upto 1 meterlong with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer -in charge |
| 34 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm |
| 35 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White |
| 36 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia |
| 37 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 40 mm dia |
| 38 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm |
| 39 | Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 40 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 41 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. PN - 16 Pipe, 20mm OD (SDR-7.4)External work |
| 42 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 43 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 44 | Providing and fixing C.P . brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 45 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 46 | Providing and fixing PTMT grating of approved quality and colour. Circular type 125 mm nominal dia with 25 mm waste hole |
| 47 | Providing & supplying ofU / L clips with washer, nut and bolts complete for fixing of wooden column. (Non scheduled item). Double U-clip set of 5mm thickness, length 22\" and width 2\" inner column fixing 4\",along with nuts/bolts of dia 1\"/1.5\" and length 5\"-6\"\" |
| 48 | Providingand fixing 6 mm thick commercial water proof plyof approved quality in false ceiling. |
| 49 | Providingand fixing 6 mm water proof PVC Wall Panelincluding fixation of interlocking Gavalized channel etc Complete. |
| 50 | Providing and fixing precoated galvanisedaluminim sheet 0.91mmThe sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required. |
| 51 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet |
| 52 | Providing and fixing soil waste pipe and vent pipe : 100mm dia PVC pipe |
| 53 | Providing and fixing plain bend of required degree 100mm dia PVC socketed pipe |
| 54 | Providing and fixing 100 mm dia P trap. as per IS:3989 |
| 55 | Providing and fixing PVC/ UPVC pipes : 100 mm dia PVC/UPVC |
| 56 | Providing and fixing 100 mm PVC grating for gully trap. |
| 57 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 58 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 59 | Wiringforlight/powerplugwith 2X4sq.mmFRLSPVC insulatedcopperconductorsinglecorecableinsurface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 60 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 61 | Supplying and fixing 3pin, 5A ceiling rose on the existing junctionbox/woodenblockincludingconnectionsetc.as required. |
| 62 | Supplyingandfixingbrassbatten/angleholderincluding connection etc. as required. |
| 63 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 64 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep |
| 65 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 66 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDBcompletewith connections, testing and commissioning etc. as required. Single pole |
| 67 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 68 | Providing and laying 3.5 Core 25 sqmm electric cable including trenching and refilling the trence |
| 69 | Supplying and fixing Led light 9 w 2 fit long make Havells , surya, phillipsetc as required. |
| 70 | Supplying and fixing Led light 20 w 4 fit long make Havells , surya, phillipsetc as required. |
| 71 | Suppying of 1400 RPM Turbo Force Grey Exhaust Fan 450 mm Sweep make Havells , Crompton, Bajajetc as required. |
| 72 | Suppying of Exhaust Fan 300 mm Sweep make Havells , Crompton, Bajajetc as required. |
| 73 | Carrying out Digital survey and preparion Lay Out Plan:- Carrying out detailed topographical survey and preparing Lay out planby marking all existing features, boundaries, buildings, carriageways, trees, electric/telephone lines, footpath, drains, sewer lines, water supply lines, ponds, hillocks, marshy lands, approach road, main road etc by using total stations, digital instruments and making contour plan preparing of drawings marking the position of the existing structures with plinth levels, calculation of the land areas, design of drainage pattern and preparing proposed LOP for BOP showing foot prints of all the proposed buildings, internal road, bulk service like street light, water supply lines,sewer line, retaining walls, helipad, boundary wall, gate etc as per requirement of client. And provide 8 set of all the colour drawing in A-3 size paper and also supply of AutoCAD generated file in Pen Drive in the requisite scale including transportation charge of men and machinery to site and return back after completion of work including mobilization charge and GST. |