| 1 | Dismentling Doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, hold fasts etc. complete and stacking within 50 meters lead. |
| 2 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge |
| 3 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material |
| 4 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 5 | PCC Work:Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland / Portland Slag cement, admixtures in recommended propor-tions as per IS:9103 to accelerate /retard setting of concrete, to improve durability and work ability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 4.20.1 All works upto plinth level :4.20.1.4 Concrete of M25 grade with minimum cement content of 300 kg /cum |
| 6 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume,hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc.complete. |
| 7 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate ( 40 mm thick with 20 mm nominal size stone aggregate) |
| 8 | R.C.C Work in Super Structure:Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended propor-tions as per IS:9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement, 5.33.2 All works above plinth level upto floor V level 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 9 | Steel Reinforment Work Above Plinth Level:Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level. 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | 230THK Brick Work in Super Structure :Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 11 | Plaster on Internal Wall:12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 12 | Plaster on External Side:15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) |
| 13 | Oil Bound distemper:Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 14 | Premium Acrylic Smooth exterior paint:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: 13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 15 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. |
| 16 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. |
| 17 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 18 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 19 | FORM WORK:Centering and shuttering including strutting, propping etc. and removal of form for |
| 20 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 21 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end locks, mounted on specially desugned pipe shaft with brakets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of provinding and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454-part 1 and M.S. top cover of required thickness for rolling shutters. |
| 22 | Providing and fixing of ball bearing for Rolling shutters. |
| 23 | Making of 40 mm gauge brick ballast at |
| 24 | Staking of old bricks at site. |
| 25 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 26 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 27 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3(1 cement : 1.5 coarse sand : 3 stone aggregates) in lighterbeams i.e. having spans upto 6 m. excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than (M-20) |
| 28 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chaijjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the |
| 29 | As in item 3 above but in R.C.C. columns in 1:1.5:3 having strength not less than [1 cement :1.5 coarse sand :3 stone aggregate] M-20 |
| 30 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of |
| 31 | As in item 3 abovebut inR.C.C.Work in footing / foundation and footingwithapproved stone ballast.(Using1:1.5:3Mix concrete) [1 cement :1.5 coarse sand :3 stone aggregate] M-20 |
| 32 | TMT Fe-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 33 | M-150 brick work in 1:6 (one cement and four coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 34 | M-150 brick work in 1:4 cement and coarse sand of 2.25 coarseness modulus mortar in super-structure. Above plinth level up to floor two level (up to two storey) including necessary cutting and molding of brick work as required and also including honey combed brick work in thickness of wall 12cms. |
| 35 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand (2.25 F.M.) |
| 36 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 37 | Providing and applying white cement based putty of average of thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 38 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 39 | Foundations, footings, bases of columns, etc. for mass concrete |
| 40 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 41 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 42 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 43 | Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works) |
| 44 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 45 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required. |
| 46 | 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 47 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 48 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 49 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: |
| 50 | Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. |
| 51 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 modular switch, connection etc. as required. |
| 52 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required. |
| 53 | Supplying and fixing brass batten/angle holder including connectionetc. as required. |
| 54 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required. |
| 55 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C\" series,miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. |
| 56 | Supply and fixing following rateing four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 57 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC shearhed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 58 | Providing, Laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I fitting including trenching (75 cm deep) and refilling etc. as required. |
| 59 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq. |
| 60 | Supply of 12 W Led BULB complete in all respect. Make-Philips or Eq |
| 61 | Supply of LED Tube Light with battern suitable for up to 1x20 watt LED tube light complete including tube etc. on surface / Pendent complete in all respect. Make-Philips or Eq. |