|
| 1 | Dargah Chowk Barri Panchyat ke Antargat Gram Nawada Main Gangiya Bagmati Nadi Par Pul Nirman Karya |
| 2 | FOUNDATION |
| 3 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
| 4 | Providing and constructing temporary island 16 m diameter for construction of well foundation for 7 m diameter well |
| 5 | Assuming depth of water 1.0 m and height of island to be 1.25 m including Royality for earth @ Rs. 5526.40 for each Island. |
| 6 | Providing and constructing one span service road to reach island location from one pier location to another pier location including Royality for earth @ Rs. 330.00 per m for service Road. |
| 7 | Providing and laying cutting edge of mild steel weighing 40kg per metre for well foundation complete as per drawing and technical specification. |
| 8 | Plain / reinforced cement concrete in well foundation complete as per drawing and technical specification |
| 9 | Well Curb(i) RCC M-35 GradeCase-II : With Batching Plant, Transit Mixer and Concrete Pump |
| 10 | Well Steining(iii) RCC M-35 GradeCase-II : With Batching Plant, Transit Mixer and Concrete Pump |
| 11 | Bottom Plug(i) PCC Grade M-20Case-II : With Batching Plant, Transit Mixer and Concrete Pump |
| 12 | Intermideate Plug(i) PCC Grade M-20Case-II : With Batching Plant, Transit Mixer and Concrete Pump |
| 13 | Top Plug(ii) PCC Grade M-20Case-I : Using Concrete Mixer |
| 14 | Well Cap(ii) RCC Grade M-30Case-II : With Batching Plant, Transit Mixer and Concrete Pump |
| 15 | Sinking of 8 m external diameter well (other than pneumatic method of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specification. Depth of sinking is reckoned from bed level. |
| 16 | Sandy Soil(i) Depth below bed level upto 3.0 M. |
| 17 | (ii) Beyond 3 m upto 10 m depth |
| 18 | (a) Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter |
| 19 | (a) Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter |
| 20 | Sinking of 6 m external diameter well (other than pneumatic method of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specification. Depth of sinking is reckoned from bed level. |
| 21 | Sandy Soil(i) Depth below bed level upto 3.0 M. |
| 22 | (ii) Beyond 3 m upto 10 m depth |
| 23 | (a) Add 5% for every additional meter depth of sinking over the rate of sinking for the previous meter |
| 24 | (a) Add 7.5% for every additional meter depth of sinking over the rate of sinking for the previous meter |
| 25 | Sand filling in wells complete as per drawing and technical specifications |
| 26 | Supplying, fitting and placing un-coated HYSD bar reinforcement (Fe 415) in foundation complete as per drawings and technical specification. |
| 27 | SUBSTRUCTURE |
| 28 | R.C.C. grade M-30 in Substructure complete as per Dwg & Tech Specification |
| 29 | i) Upto 5m heightCase-II : With Batching Plant, Transit Mixer and Concrete Pump |
| 30 | ii) From 5m upto 10m height Case-II : With Batching Plant, Transit Mixer and Concrete Pump |
| 31 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 |
| 32 | Supplying,fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications. |
| 33 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 34 | Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 |
| 35 | Providing and laying filter media with granular crushedaggregates (Jhama Metal)as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8 |
| 36 | SUPERSTRUCTURE |
| 37 | Providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 |
| 38 | Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in superstructrue complete as per drawings and technical specification Clauses 1002, 1010 & 1202 |
| 39 | Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 |
| 40 | Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 |
| 41 | Drainage Spouts complete as per drawing and technical specifications Clause 1209 |
| 42 | P.C.C. M-15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specificatios Clauses 800 & 1211. |
| 43 | Reinforced Cement Concrete M-30 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 |
| 44 | Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm,complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer\"s instructions for installation.) |
| 45 | APPROACH Road |
| 46 | Clearing and Grubbing Road Land ( By manual means)including uprooting wild vegetation , grass ,bushes ,shrubs , saplings and trees ofgirth upto 300mm , removals of stumps of such trees cut earlier & disposal of unserviceable materials & stacking of serviceable materials to be used or auctioned upto a lead of 1000 m including removal and disposal of top organic soil not exeeding 150mm in thickness as per technical specification - clause 201.1 and direction of E/I |
| 47 | Construction of Embankment with material obtained from borrow pits with a lift upto 1.5 m , transporting to the site spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 . |
| 48 | Construction of Subgrade and Earthen ShouldersConstruction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. |
| 49 | Granular Sub-base with Well Graded Material (Table 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. |
| 50 | WBM Grading 3 (By Manual Means) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with threewheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. |
| 51 | Prime Coat (Low porosity)Providing and applying primer coat with Bitumen emulsion (SS-1)on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70- 1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. |
| 52 | Tack Coat Providing and applying tack coat with bitumen emulsion (RS ) using emulsion distributor @ 0.2 to 0.25 kg per sq m on the prepared bituminous surface cleaned with hydraulic broom as per technical specification clause 503. |
| 53 | Mix Seal Surfacing Type BProviding, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 Type B |
| 54 | Informatiry Sign BoardProviding and Fixing \"Logo\" of Projectinformayory sign board with Logo as per MORD specifications and drawing.Three MS plates of1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5 m size on back on edges.The lower plate will be welded with MS angle ironframe of25mm x 25mm 5mm.The angle iron frame of the lower mostplate and flat iron frame of middle plate will be welded to 2 Nos.75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600 mm,600 mm,600 below ground level.The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12SWG steel plate tube.All M.S will be stove enameled on both sides. Lettering and printing arrows, border etc, will be painted with ready mixed synthetic enamer paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 abd Annexure 1700.1. |
| 55 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous SurfaceProviding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. |
| 56 | Boundary PillarReinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704 |
| 57 | 1% LABOUR CESS= |
| 58 | SEIGNOIRAGEFEE10% = |
| 59 | 18% GST= |
| 60 | 1st Year Maintenance cost |
| 61 | 2nd Year Maintenance cost |
| 62 | 3rd Year Maintenance cost |
| 63 | 4th Year Maintenance cost |
| 64 | 5th Year Maintenance cost |
| 65 | 1% LABOUR CESS= |
| 66 | SEIGNOIRAGEFEE10% = |
| 67 | 18% GST= |