| 1 | Dismantling of old Exisiting plaster I/C disposal ofrefuse as directed by Engineer-in-charge. |
| 2 | Dismentling of old Door or windows i/cchaukhats with hold fast I/C stacking of material asa directed be the eng.-in-charge. |
| 3 | Dismantling brick work or stone work in lime or cement mortar & I/C stacking of material asa directed be the eng.-in-charge. |
| 4 | Dismantling cement concrete or brick work or granolithic floors I/C base conc. All comp. of work. |
| 5 | Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-incharge. |
| 6 | Filling of carted earth. |
| 7 | Conc with 4 Cm gauge Stone ballast Coarse sand of 2.20 FM and cement in proportion of (1:4:8) in foundationand under floors including supply of all materials. |
| 8 | M-150 class brick work (1:6) with cement & fine sand mortar in sup-structure foundation plinth I/c all comp of work . |
| 9 | R.C.C. (1:1.5:3) with cement ,approved coarse sand &2 cm gauge stone girt for beam |
| 10 | R.C.C. (1:1.5:3) with cement ,approved coarse sand &2 cm gauge stone girt for Slab |
| 11 | M.S. item work such as R.C.C. Completion of work as per S.I. No. 504 |
| 12 | 12 mm thick cement plaster (1:6) cement & fine sand on fair side of wall i/c propercompletion of work. |
| 13 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover |
| 14 | Providing and fixing Top cover for rolling shutters. |
| 15 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm |
| 16 | Trimixing of the Surface of the Cement Concrete Laid |
| 17 | Supply and fixingof flushdoors commercialqualityconformingtoI.S. 2202 Part I (1983) includingfixingof woodencleats and stoppers and including ixing andadjustmentstoppers and including ixing andadjustmentof hinges, bolts,locks, handle, springs and other Fittingwith necessaryscrews to be supplied departmentally. |
| 18 | Providing & fixing of hold fast for chaukhatsof doors and windows. |
| 19 | Providing & fixing of door / windows grill. |
| 20 | Z-Section steel windows (openable) |
| 21 | Angle ironchaukhats (35*35*5) |
| 22 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 12 mm mild steel U beading |
| 23 | (a) Door chaukhats |
| 24 | (b) Window chaukhats |
| 25 | Provinding Wall Cement Based Putty on New Surface |
| 26 | Distempering of Ist Quality Acrylic Distemper |
| 27 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 28 | Provinding Two Coat Primer |
| 29 | Centering and Shuttering (Slab) |
| 30 | Centering and Shuttering (Beam) |
| 31 | Providing and laying\"brick coba\" 12mmthick laid with M.150 class brick bat coba7.50cm. Thick with gap of 15mm to each other.over 20mm. Thick base of cement morter 1:4cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete waterproofing compound filed gaps of coba & top of cobamortar mixed with water proofing compoond.in 1:4 cement & coarse & morter finished smooth & top mashed false square 30cmX30cm.& side wall parapet shall be mono tythicplaster wall up to 30cm.higher & junction & corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc. com.for proper completion of work. |
| 32 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete. |
| 33 | Earth Work in Filling with cartage |
| 34 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401. |
| 35 | S/Laying of 80mm thick precast cement concrete I-shape Interlocking pane blocks with to layer of minimum 8mm thickness having plan dimension 200x(160+120mm) of O.P. cement ,smooth high gloss finish, skid resistant manufactured from ruber moulds thriugh vibro-compression mechanisam, the compressive strength of concrete paver block shall not be less than 30Mpa(M-30)and weight 5kg per nos.confiming to IS15658-2006 I/c cost material,with ablanket layer of 4.00 Cm thick fine sand labour,T&P and Vat ctc required for proper completion of the work.Si no-N.Item. |
| 36 | Wiring point for light,fan /fresh air fan (light duty exhaust fan) & call bell with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
| 37 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealedM.S. box including supply of all material, labour T & P etc required for proper completion of work. |
| 38 | Supply & wiring of submains with two number2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. |
| 39 | Supply & wiring of submains with two number4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. |
| 40 | Supply and wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in20mm dia heavy duty (2mm thick ) PVC conduit partly concealed in wall and partly laid in slab along with reinforcement befor concreting with one number 4.0 Sqmm FRLSH PVC Multistand copperearth contunity wire including colour wash etc. complete in all respects. |
| 41 | Supply & fixing of single wall bracketon matching M.D.F.E.G.boardbase etc. complete in all required. Cat. A |
| 42 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.1 X 22 WCAT-AAA |
| 43 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system.BEE 5 Star rated-1200mm sweep |
| 44 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve5 - 32 amps.Cat. A |
| 45 | Supply and fixing of 6Amp to 32 Amp DP MCB(10KA)C Curve |
| 46 | Supply and fixing of 40 Amp. 4 Pole MCB (10KA) |
| 47 | 8 Way SPN Cat. A |
| 48 | pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in |
| 49 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects. |
| 50 | Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
| 51 | SANITARY FIXTURES & ACCESSORIES |
| 52 | SOIL WASTE & VENT PIPES AND FITTINGS - II |
| 53 | EXTERNAL WATER SUPPLY SYSTEM -II |
| 54 | Septic Tank(Size :- L = 3.0 M. W = 2.00M Total D =3.00M) |
| 55 | Drilling with Suitable rig having8/10\"dia bore size all kind of strata expect hard Rock. |
| 56 | Cartage Charges Approx Pump Fitting |
| 57 | Pump fitting |
| 58 | Supply & Fixing of Kirloskar KS4AN-1014 HP 4 inches borewell water filled Summerseble PUMP 11780100480 |
| 59 | Supply & Fixing of 100 mm dia UPVC Plain Plain Pipe |
| 60 | Tubewell Fitting like bail plug cap, clamp etc. |
| 61 | Supply & Fixing of electrical pannel Board. |
| 62 | Supply & Fixingof 2.50 sqmm wire for sumersebile pump. |
| 63 | Providing & Laying of 1 1/2\" UPVC coloumn pipe Astral |
| 64 | Supply & Fixingof PVC coated wire ropesqmm wire for sumersebile pump. |
| 65 | Providing & Laying of 1 1/2\" dia pump fitting like elbow, nipple clamp, adopter |