| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group A |
| 3 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 4 | 20 mm |
| 5 | 25 mm |
| 6 | 32 mm |
| 7 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 8 | Blanking Plate |
| 9 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 10 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 11 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 12 | 3 x 1.5 sq. mm |
| 13 | 3 x 4 sq. mm |
| 14 | 6 x 25 sq.mm. |
| 15 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 16 | 8 way (4 + 24), Double door |
| 17 | Supplying and fixing following rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 18 | Single pole 5 A to 32 A |
| 19 | Triple pole (40A-63A) |
| 20 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 21 | 125 A,36KA,FPMCCB |
| 22 | Supplying & fixingConnecting , testing & commissioning, of fully automatic star delta starter for 25 HP electric submersible pump including 4 pole ML contactors and MN5, overload relay single phasepreventer ON-OFF LED indicator, Amp. & voltmeter etc, 415 V, 50Hz, 3 phase in sheet steel enclosure L&T make Cat no.CS96008COEOor it\"s equivalent approved make as required complete. |
| 23 | S & F, connecting and commissioning 4 pole Front handle operated in sheet steel enclosure On Load changeover switch of following capacity etc. as reqd. |
| 24 | 125 Amp |
| 25 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 26 | Supplying and laying of one no. 3.5 x70.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 27 | in ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 28 | In Pipe |
| 29 | In open duct |
| 30 | On Surface |
| 31 | Supplying and laying of one no. 3.5 x185.0 sqmm PVC insulated, XLPE steel armoured aluminium conductor power cable of grade 1.1 kVas required complete in following manners. |
| 32 | In ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 33 | In Pipe |
| 34 | In open duct |
| 35 | On Surface |
| 36 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 37 | 3½ X 70 sq. mm (38mm) |
| 38 | 3½ X 185 sq. mm (57mm) |
| 39 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 40 | Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. |
| 41 | Providing, laying and fixing following dia G.l. pipe (medium class) in ground complete with G.l. fittings including trenching (75 cm deep)and re-filling etc as required |
| 42 | 80 mm dia |
| 43 | Supply & Laying of32 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete. |
| 44 | in ground I/c excavation, sand cushioning, protective covering and refixing the trench etc as reqd |
| 45 | Supplying and Fixing following size angle iron in required shape and size i/c cutting, welding, painting etc. as reqd. |
| 46 | 50 x 50 x 6 mm |
| 47 | Supply and fixing of following LED light fixture with efficiency >100 lumen/ watt, P.F. >0.95, THD<10%,Electronic driver,LED lamp, reflector, diffuser, MS body/housing holder etc. complete with all fixing accessories and lamp as required complete. |
| 48 | 1 X 20W Box type LED tube with fitting |
| 49 | Supply and fixing testing and commissioning of10 wattLED bulkhead fixture with Electronicdriver, lamp, reflector, diffuser, MS body/housing holder etc. complete with all fixing accessories and lamp as required complete.(eq. To Cromptoncat. no.LBHE-10-CDL |
| 50 | Supplying and fixing, following LED street light luminaries with pressure die cast aluminiumIP65 housing, driver etc. complete with all accessoriesas required. |
| 51 | 25 Watt LED street light luminaries |
| 52 | Supply Installation, testing and commissioning of following ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 53 | 1400 mm sweep |
| 54 | Supplying and fixing exhaust fan shutter for following sizes exhaust fan on rag bolts as reqd complete. |
| 55 | for 300 mm / 12\" sweep |
| 56 | Supply, Installation testing and commissioning of following seep, copper wound, 900 RPM, 220 volt AC, 50 Hz exhaust fan in the existing openingetc as required complete. |
| 57 | 300 mm / 12\" sweep |
| 58 | Fabricating, supplying & fixing of box of required size and shapemade out of 2mm thick CRCA sheet duly powder coated, Locable & openable from or front, top or bottomas required complete. |