Tender For Road Safety Work On Noida - Greater Noida Expressway, Noida. - Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per som area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35-2015 The finished surface to be level, uniform and free from streaks and holes. 2 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface. (Repeated/ Tranvers bar) Providing and laying of hot applied thermoplastic compound 5 mm thick including reflectorising glass beads 500 gms per sqm area, thickness of 5 mm is exclusive of surface applied glass beads as per IRC:35-2015 The finished surface to be level, uniform and free from streaks and holes. 3 Solar Power road marker (Solar studs)The solar studs shall be made of Aluminum alloy and poly carbonate material which shall be absolutely weather resistance and strong enough to support a load of 13,635 Kg tested in accordance with ASTM D4280. Its colour may be white,red,yellow,green or blue or combination as directed by the Engineer. Its water resistance shall meet the requirements of IP 65 in accordance with IS:12063:1987 category 2 for protection against water ingress. The dimensions of solar studs shall not be less than 100mm X 100mmX10mm. It shall have super bright LEDs so as to provide long visibility from a distance of more than 800 m. Its flashing rate shall not be less than 1 Hz. Its should be able to give the prescribed performance in the temperature range-40*C to 55*C. Its life shall be not less than 3 years. The rate shall be include all materials, labour, equipments, fabrication, transportation,erection,installation and incidentals all complete as per direction of the Engineer-in-charge. 4 Reflective Raised Pavement Markers (Cat Eye/ Road Stud) Supply and fixing of raised pavement marker with Made of Plastic body of RPM/ Road Stud shall be moulded from ASA (Acrylic Styrene Acrylonitrite) or HIPS (High-Impact Polystyrene) or Acrylonitrile Butadien Styrene (ABS) or Any other suitable material approved by the Engineer. The Marker shall support a load of 13,635 kg tested in accordance with ASTM D4280.The Reflective panels shall consist of number of lenses contatning single or dual prismatic cubes capable of providing total internal reflection of the light entring the lens face. Lenses shall be moulded of methyl methecrylate conforming to ASTM D788 or equivalent. The slop or retro-reflecting surface shall preferably be 35+/-5 degree to base and the area of each retro -reflecting surface shall not be less than 13.00 sq.cm. marker height shall not be less than 10 mm and shall not exceed 20 mm & Width shall not exceed 130 mm. The base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name , trade or other means of identification of the manufacture. epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. The contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflectance of the reflecting panel , to the Engineer . In addition , a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers. In case the markers are displaced , damaged , get worn out or lose their reflectivity compared to stipulated standards , the contractor would be required to replace all such markers within 15 days of the intimation from the Engineer , at his own cost. The rate shall include all materials, labour, T&P, transportation,installation and incidentals all complete as per direction of the Engineer-in-Charge.As per SOR ch-26 SI no.-5 RPM with Shank 5 Flexible Median Marker as per IRC 79:20:19 Flexible Median Marker (FMM) should be used for improving median visibility during dark hours. Use ofMedian Marker provides safety against collision happening with medians during night time, or serve whether. Flexible Median Markers shall be provided with fluorescentYellow colour retro reflective sheeting type XI as per IRC 67, flexible Median Marker shall be of tough high impact resistant injection molded thermoplastic body with property of flexibility to provide high durability and U shape structure having rebound, bounce back property the sheeting shall be type XI confirming to IRC 67 and it should be own both the faces whereby providing maximum reflectivity at I, anger distance with adequate durability The logo of the manufacturer shall be embossed on either side of the body during the injection molding process FMM shall be fixed by a combinitation ofapoxy adhesive and grouting drilling on concrete Median of properly constructed solid medians. Height. The marker height shall be a median of 180mm, width 120mm and body thickness 6.5mm, the shanks shall not be less than 20mm and depth shall not be less than 30mm reflective area shall not be less than 90cm square proof of the same report shall be uploaded which quoting tender. The body of FMM shall bounce back to its original position of after 750 number of hits using pendulum of 1.8 kg confirming 40 ASTMD256 adhesion between the body and outer casing body of FMM shall with stand 50kg. Tensile loads confirming to ASTMD638 method, The rate shall be include all materials,labours, T&P transportation installation and incidentals all complete as per direction of the Engineer-In-charge . 6 Tubular Makers (Spring Post or Spring Bollard)S/Fof plastic Tubular bollards having 450 mm to 700 mm Height shall be attached to the pavemet to display the minimum 50 mm width of reflective bands to the approaching road users including labour material T&P etc. for proper completion of the work. 700 mm Height. 7 Road Delinator Delineator: Supply & Fixing of M S Delineator made of Mild steel with pure polyester powder coating with the minimum thickness of powder coating of not less than 40 micron for protection against corrosion. The surface should be conceated so that there should not be any exposed surface without powder coating. Alternatively, these metal guide poles can be concealed with thermoplastic body. The posts shall have lan ellipsoidal or circular design with the height of the pole shall be 800 to 900 mm above the ground with about 200 to 300 mm base which can be anchored onto the ground. Mild steel Guide Poles shall conform to Type XI sheeting specifications as per IRC:67 and ASTM D4956 which would ensure to obtainl clear visibility of the road alignment during night time.The Retro reflective sheeting shall be tested for A certificate of having the sheeting tested for coefficient of retro reflection, day time colour & luminance, shrinkage, flexibility, liner removal, adhesion,impact resistance,specular gloss & fungus resistance, 3 years outdoor weathering & its having passed these tests shall be obtained from International/ Government Laboratory / Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials,labour,T&P, transportation,installation & incidentals all complete as per direction of the Engineer-in-Charge MoRTH 805 (8.15) CH-26 LUCKNOW SOR 2020-21. 8 Aluminum-backed flexible prismatic sheeting shall be made of yellow colored flexible prismatic sheeting with non-metallic prismatic lens formed in a transparent, synthetic resin as retro reflective elements. This flexible prismatic sheeting shall have black and yellow stripes with aluminum backed flexible prismatic Type VI sheeting conforming to ASTM: D4956 . specifications and standards of coefficient of retro reflectivity, flexibility and impact resistance applicable for reboundable devices. This flexible prismatic sheeting shall have screen printed arrow/slant line pattern in black colour in a continuous roll format. Width of object marker shall be 300 mm.The rate shall include all materials, labour, T&P, transportation,installation and incidentals all complete as per direction of the Engineer-in-Charge. 9 Retro-reflectorised Traffic sign as per IRC-67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC 67-2012 made of high intensity grade sheeting type-IV vide clause 801 3, fixed over aluminium sheeting 15 mm thick supported on a mild steel angle iron post 75 mm X 75 mm X 6 mm firmly fixed to the ground by means of property designed foundation with M 15 grade cement concrete 45 cm X 46 cm X 60 Cm , 80 cm below ground level as per approved drawing. The reto reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, day time colour luminance shrinkage flexibility siner removal adhesion, impact resistance, specular gloss and fungus resistance 3 years outdoor weathering and its having passed these tests shall be obtained from international government laboratory institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition it should also be obtained from indian condition within 3 years of launching of product by the manufacturein abroad atternatively a certificate conforming to ASTM specification to 495609 on artificial accelerated weathering requirements from a reputed laboratory in india can be accepted provisionaly in such a situation the employer/cllient so could seek for a performance guranttee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 2012 Legends letters numerals and borders etc should as per McRth Specification No. 60137. Proof of the sama in form of government report shall be uploaded while quoting tender. 30X90 cm (Left/Right) Object Hazard. 10 providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67-2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Proof of the same in form of government report shall be uploaded while quoting tender.60 mm x 45 mm rectangular with diffinitation plate (20cm X 60cm) 11 providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67-2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Proof of the same in form of government report shall be uploaded while quoting tender. 60 cm circular with definition plate (20cm X 60cm) 12 providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67-2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Proof of the same in form of government report shall be uploaded while quoting tender. iii) 50X60 cm single chevron 13 Retro-Reflective sheeting type-IV with 4mm thick ACM single SideProviding & Fixing of reflective signs with a corrosion resistant 4mm thick with 0.4 to 0.5 mm both side aluminium skin aluminium composite panel face to be fully covered with High intensity prismatic sheeting type XI as per IRC-67:2012 retro reflective sheeting with back frame MS angle of 35x35x5mm Legenda, letters, numerals and borders etc should be as per MoRTH specification No-801.3.7. The Sheeting shall have a pressure- Sensitive adhesive of the aggressive lack type requiring no heat. solvent other preparation for adhesion to a smooth clean surface, in a manner recommended by the sheeting manufacture. The ACM (Aluminium Composite Materials) Shall be fixed on the Back frame MS Angle with riveting. Micro Prismatic type IV Retro reflective sheeting confirming to ASTM D4956-09 Shall be pressure fixed. The Retro reflective, daytime colour and luminance, shrinkage, flexiblitily, liner removal, adhesion, impact resistance, specular glass and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obrained from international/Government Laboratory/institute by the manufacture of the sheeting and in case the certificate is obtained from internation condition, it should also be obtrained from indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively a certificate conforming to ASTM Specification (D4956-09) on artifical accelerated weathering requirements from a reputed laboratory in india can be accepted provisionally, in such a situation, the Employer/Client. if so desires, could seek for a performance guarantee, in such a situation, the Employer/Client. if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials, labour, T&P, Transportation, installation and incidentals all complete as per direction of the Engineer-in-chage. 14 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete 15 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.The Contractor has to detect diffrent utilites like sewer line, etc.Using utility detecting machine before start of excavation and shall start excavation only after gettingpermission of Engineer-in- Charge. All kinds of soil. 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 17 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 18 Steel work welded in built up sections/framed work i/c hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.