| 1 | Taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings., etc) and Supply and Laying underground LT CableXLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 16 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified and directed. Note item No 01 & 02 :-(a) Excavation, Concrete cable protection cover, pipe, PCC work for road crossing/hard standing and Sand for cushioning will be measured and paid separately.(b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), new nut, bolt and washers of required size/description are deemed to include in this rate. |
| 2 | All as per item No 01 here in before but of size 4 core 10 sqmm complete. |
| 3 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard / dense soil getting out and leveling of bottom surface to required level for laying UG cable / erection of poles complete all as specified. |
| 4 | Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft / disintegrated rock getting out and leveling of bottom surface to required level complete all as specified and directed |
| 5 | Excavation in trenches by cutting of road crossing / PCC hard standing, under boundary wallfor laying of pipe / cable including making good the existing surface with same finish to match the original finish complete all as specified and directed. |
| 6 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 7 | Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed. |
| 8 | Supply and Laying Double walled corrugated pipe (DWC) confirming to IS 14930 heavy duty 63 / 50 mm bore for cable protection as a guard pipe including required accessories etc including taking down existing PVC pipe any type complete as specified and directed. |
| 9 | Supply and fix or laying in trenches / on wall / poles / structures of GItubing 50 mm dia light grade for road crossing/for cable protection / fixing of pigmi lights etc including necessary provision for cable entry if required in pigmi lights pole, fixing screws and taking down existing old GI tubing complete all as specified and directed. |
| 10 | S & F in repair Street light bracket made out of GI tubing 32 / 40 mm dia of approx 1.2 mtr length, light grade bend to shape suitable for security / street light / Pigmi light fittings with necessary fixing arrangements by using GI flat of 40 x 6 mm size including nut, bolt, washers etc complete all as specified. |
| 11 | S & F Energy efficient LED street Light 100 Watts 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65 / 66 protection, Individual LED must have peanut lenses for better throw with luminaries efficiency of greater than 100 lumen / watt. The luminaries should have 5 KV surge protection, PF>0.95 and total harmonic distortion of THD <10% voltage range of 140-280V should be provided. The manufacture\"s LOGO must be embossed / Engraved in the housing of the luminaries complete all as specified and directed. |
| 12 | Supply & transporting and erecting in replacement octagonal hot dipped galvanised mild steel pole with grey powder finish 7 meter long complete withtop dia of size 70 mm and bottom dia of sie 130 mm including base plate of size 200X200X12 mm, foundation nuts bolts including RCC foundation of suitable size to withstand the said pole and GI bracket for mounting on top of the pole for fixing street light including dismantling of existing RCC pole with ACSR conductor, MS cross arms, clamps, nut / bolts etc complete all as specified and directed by Engr-in-Charge. Note:-(a) Cost of Excavation for removing of old RCC pole of required length, width and depth are deemed to include in this rate.(b)Cost of Excavation for fixing of New octagonal pole of required length, width, depth and construction of suitable RCC platform, bolts and nut as per manufacture specification, drawing etcare deemed to include in quoted rate.(c) Old unserviceable RCC post and MS clamps, nut & bolts etc obtained from site to be taken in schedule of credit items respectively. |
| 13 | S &F in repair PVC unarmoured 1100V grade three core multi stranded copper conductor cable of size 2.5 Sqmm including lugs on both ends and including connection complete all as specified and directed. |
| 14 | S & F sheet moulding compound junction box (SMC) suitable for terminating 2 Nos 4 x 6/10/16/Each sqmmUG cable including one in Nos MCB SP 0.5 Ampsincluding cable glands of 2 Nos, and two way connector 1 No, including dismantling old one complete all as specified and directed.Note:-MS Clamp, nut, bolt and washer measured and paid separately. |
| 15 | Supply, Installation, Testing, Programming and commissioning of AMF panel (outdoor type) factory made weather, dust and vermin prooffree floor each mounted, paneled double door(both side opening) totally enclosed made out of 3.15mm thick CRCA steel, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer,sheet as size having opening and locking arrangement with cable tray of size not less than 20 cm CPRI approved factory made suitable for IP 54 protection complete internal wiring with suitable size copper conductor cable lugs, ferrules and cables and external connection suitably for 82.50 KVA capacity DG set operation bypass arrangement having Main voltage / Generator voltage and frequency monitoring, automatic start / stop, Load transfer control, Alarm for fault indications such as Main failure, Generator failure to Start, Overload, Low Oil pressure, High Engine Temperature, Battery Low Voltage and configurable timers and delaysincluding copper busbar size 25x06 mm,fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories described under SL No 15.01:- |
| 16 | (i) Contractors (02 Nos), MCCB of 125 Amp (03 Nos), 4 Pole with add on block and Mechanical interlock having MCCB 125. (ii) Indicator lamps (LED type) -01 Set (iii) Suitable no of ON / OFF / RESSET push buttons with element. (iv) Control MCB SP 4Amp \"C\" curve 10 KA. (v) SMPS 5 A rating - 01 No.(vi) Micro controller base intelligent AMF are lay to monitor parameters viz. voltage current, frequency, energy suitably for all engine parameters.(vii) Battery with battery charger for powering the panel for a minimum 60 minutes in case of supply failure of approved make.(viii)Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments - 01 lot |
| 17 | S & F in replacement VTPN 12 way TPN distribution board with provision for MCCB Win break 1 as incomer & 1 Win trip outgoing, suitable for Flush monitoring and surface mounting with 100 Amp copper Busbar for each phase with 2 Neutral bar, 2 Earth bar and cabletiles for cable management fully insulated Busbar & shrouded Neutral bars in proved Pan assembly forease of installation Profited masking sheet reversible Door for IP 43 & IP 54 DB\"s including provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP code : CSDBMCCB 125PDD12 S complete all as specified and directed. |
| 18 | S & F MCCB 63 Amp, 3 phase, 4 pole 415 volts, 50Hz with thermal magneticrelease with braking capacity 25 KA, positiveIsolation, Trip free mechanism, Neutral with 100% rated current, bounce free contact structure complete including dismantling of existing unserviceable MCCB and connection any descriptioncomplete all as specified and directed |
| 19 | S & F 240 V,10 KA \"B\" curve miniature circuit breaker (MCB) of single pole and currant carrying capacity5 to 32 Amp, including connection, testing & commissioning and dismantling of existing unserviceable MCB and connection any descriptioncomplete all as specified and directed |
| 20 | S & F MCB DB , Isolator of double pole and currant carrying capacity 40 KA, in MCB DBincluding connection, testing & commissioning and dismantling of existing unserviceable MCB and connection any descriptioncomplete all as specified and directed |