Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #48971452

Tender For Repair And Maint Of Internal Electrification Including Fans Geysers And Solar Geysers At Appointment Houses Guest House Peacock Bay Mh Mess Jfc Area And Offrs Married Accn At D1 D2 And E3 Area At Nda Khadakwasla

Issued by Statutory Bodies & Commissions/Committees · khadakwasla, Maharashtra
Tender Value
40 Lakhs
Estimated cost
Bid Submission
21 May 2025
0 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
khadakwasla → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Repair And Maint Of Internal Electrification Including Fans Geysers And Solar Geysers At Appointment Houses Guest House Peacock Bay Mh Mess Jfc Area And Offrs Married Accn At D1 D2 And E3 Area At Nda Khadakwasla

BOQ

Name of Work: REPAIR/MAINT OF INTERNAL ELECTRIFICATION INCLUDING FANS, GEYSERS AND SOLAR GEYSERS AT APPOINTMENT HOUSES,GUEST HOUSE,PEACOCK BAY,MH MESS,JFC AREA AND OFFRS MARRIED ACCN AT D1,D2 AND E3 AREA AT NDA KHADAKWASLA
Sl. No. Item Description
1Repair / maintenance of internal light fitting of any typelike tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the compenents / parts, wiring etc, identifying and replacing the defective components like tube rod, side holders, holders, lamps etccomplete all as specified and directed .Note:(i)The rate against the above mentioned item is deemed for cost of labour only. (ii) Cost of spares like capacitor, lamp holder, connector, connection wire etc. replaced against above mentioned item will be measured & paid separately under respective items of Sch \"A\" here-in-below. (iii)The contractor\"s representative (supervisor) will report to concerned JE E/M at 0900hrs daily to collect the list of complaints and will submit the completion report on the same day before 1700hrs to the JE E/M.(iv) The contractor shall address all the given complaints within 24 hours from the time the list of complaints is handed over to him / his rep by the concerned JE E/M.In case the complaint is not addressed for whatsoever reason within the specified time limit (48 hrs), an amount of Rs 100/- per such complaint per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairer for each at D1 area, D2 area E3 area & Appointment houses/Guest houses (04 x teams).(v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for.(vi) The contractor shall maintain sufficient stock of spares / material required for repair / maint of light fittings with the concerned JE E/M against the supply only items here-in-below.(vii) During the contract period, if the same complaint is repeated, it will be regarded as a single complaint, and no additional payment will be made for addressing the repeated issue.
2Supply only following spares for light fittings of branded make as mentioned in the list of make enclosed with Particular specifications for replacement :- (a) PVC / polycarbonate lamp holders batten/Angle type
3S & Fin repair of switch piano flush type 6 Amps SP one way all as specified and directed.
4S & Fin repair of switch piano flush type 6 Amps SP two wayall as specified and directed
5M&L inrepair bell push, flush type 6 Amps all as specified and directed.
6M&L inrepair of pendent (Bed) switch 6 amps single phaseall as specified and directed.
7S&F in repair ofsocket 5/6 Amps flush mounted5 pinall as specified and directed
8S&F in repair ofsocket 5/6 Amps flush mounted2 pinall as specified and directed
9S & F in repair ofswitch socket combination 5/6 Amps flush mounted 5 pin multi purposeall as specified and directed.
10S & F in repair ofswitch socket combination with box of 5/6 Amps flush mounted 5 pin multi purposeall as specified and directed
11M&L in replacment of fan regulator switch/socket type electronic steptype suitable for 1200/1400 mm sweep fan as per the sample providedall as specified and directed
12S & Finrepair of switch piano type 20 Amps SP one wayall as specified and directed
13S&F in repair ofsocket 5/15 Amps flush mounted3/5 pin multi purposeall as specified and directed
14S & F in repair ofswitch socket combination 5/15 Amps flush mounted3/5 pin multi purposeall as specified and directed
15S & F in repair ofswitch socket combination with box of5/15 Amps flush mounted3/5 pin multi purposeall as specified and directed
16S&F in repair for ceiling rose, 2 to 3 terminals /PVC/Polycarbonate, isolated bodyall as specified and directed.
17S&F in repair plug top 3 pin, 6 amps, 230 volts, ISI marked heavy dutyconnection cordall as specified and directed.
18S&F in repair plug top 3 pin, 15/16 amps, 230 volts, ISI marked heavy duty for geyser connection cordall as specified and directed.
19S&F in repair plug top 2 pin, 6 amps, 230 volts, ISI marked heavy dutyconnection cordall as specified and directed.
20S&F in repair metal clade sockets 20 amps, 230 volts, ISI marked heavy dutyconnection cordall as specified and directed.
21S&F in repair metal clade plugs 20 amps, 230 volts, ISI marked heavy dutyconnection cordall as specified and directed.
22M&L in repair of door bell AC 230 volts single phase ding dong type all as specified and directed.
23M&L in repair of wire less door bell AC 230 volts single phase ding dong type all as specified and directed.
24S & F in repair of PVC unbreakable surface boxesof 1 gang boxall as specified and directed
25S & F in repair of PVC unbreakable surface boxesof 2 gang boxall as specified and directed
26S & F in repair of PVC unbreakable surface boxesof 3 gang boxall as specified and directed
27S & F in repair of PVC unbreakable surface boxesof 4 gang boxall as specified and directed
28S & F in repair of PVC unbreakable surface boxesof 5 gang boxall as specified and directed
29S & F in repair of PVC unbreakable surface boxesof 6 gang boxall as specified and directed
30S & F in repair of PVC unbreakable surface boxesof 7 gang boxall as specified and directed
31S&F in repair modular switch piano type 10 amps one way one moduleall as specified and directed
32S&F in repair modular switch piano type 10 amps two way one moduleall as specified and directed
33S&F in repair modular Bell push, 10 Amp with neon indicator one moduleall as specified and directed
34S&F in repair modular switch piano type 20 amps one way one module with neon indicatorall as specified and directed
35S&F in repair modular Socket, 6A - 2/3 pin2 moduleall as specified and directed
36S&F in repair modular Socket, 6/16A - 2/3 pin 2 moduleall as specified and directed
37S&F in repair of 1 module Blanking plates complete all as specifed and directed
38S&F in repair modular step type fan regulator 100W, 1/2 moduleall as specified and directed
39S&F in repairfor white cover plate with frame 1 or 2 moduleall as specified and directed.
40S&F in repairfor white cover plate with frame 3 moduleall as specified and directed.
41S&F in repairfor white cover plate with frame 4 moduleall as specified and directed.
42S&F in repairfor white cover plate with frame 6 moduleall as specified and directed.
43S&F in repairfor white cover plate with frame 8 moduleall as specified and directed.
44S&F in repairfor white cover plate with frame 12 moduleall as specified and directed.
45S&F in repairfor white cover plate with frame 16 moduleall as specified and directed.
46S&F inrepairfor white cover plate with frame 18 moduleall as specified and directed.
47S& F in repair PVC unbreakable surface boxes suitable for modular switches 1 or 2 moduleall as specified and directed.
48S& F in repair PVC unbreakable surface boxes suitable for modular switches 3 moduleall as specified and directed.
49S& F in repair PVC unbreakable surface boxes suitable for modular switches 4 moduleall as specified and directed.
50S& F in repair PVC unbreakable surface boxes suitable for modular switches 6 moduleall as specified and directed.
51S& F in repair PVC unbreakable surface boxes suitable for modular switches 8 moduleall as specified and directed.
52S& F in repair PVC unbreakable surface boxes suitable for modular switches 12 moduleall as specified and directed.
53S& F in repair PVC unbreakable surface boxes suitable for modular switches 16 moduleall as specified and directed.
54S& F in repair PVC unbreakable surface boxes suitable for modular switches 18 moduleall as specified and directed.
55S&F in repair for squre box, 2 to 3 terminals /PVC/Polycarbonate, isolated bodyall as specified and directed.
56S&F in repair for round plate, 2 to 3 terminals /PVC/Polycarbonate, isolated bodyall as specified and directed.
57S&F inrepair ofPVC insulated copper cable 1 Sqmm 3 core, served with inner sheathing of PVC tape and overall PVC sheathed including PVC Conduit ISI Marked 20mm including all necessary bends, couplings, tees, and other accessories.Surface Saddling of PVC Conduit on Wall using approved saddles and fixing screws. Spacing as per specifications ( 1-meter intervals). all as specified and directed
58Ditto all as per item no.57 above but 2,5 Sqmm 3 core
59Ditto all as per item no.57 above but 4 Sqmm 3 core
60S&F in repair of 1100 volts grade heavy duty service cable 2.5 Sqmm two core PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed including PVC Conduit ISI Marked 20mm including all necessary bends, couplings, tees, and other accessories.Surface Saddling of PVC Conduit on Wall using approved saddles and fixing screws. Spacing as per specifications (1-meter intervals). all as specified and directed
61Ditto all as per item no.60 above but 4 Sqmm 2 core
62Supply only 9 W WW LED Lamp for E14/E27/B22 Holdersall as specified and directed.
63Supply only 5 W WW LED Lamp for E14/E27/B22 Holdersall as specified and directed.
64Supply only 3 W WW LED Lamp for E14/E27/B22 Holdersall as specified and directed.
65Supply only 0.5 W WW LED Lamp for E14/E27/B22 Holdersall as specified and directed.
66S&F in repair of 10 watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed
67S&F in repair of 20 watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling roseall as specified and directed
68S&F in repair of 20 watt,230V3 IN 1 surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling roseall as specified and directed
69S&F inrepair of 20 watt,230V surface and wall mounted Inverter LED batten, automaticaily switched ON during a power cut and runs effiectively up to 3 Hrs,extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling roseall as specified and directed
70S&F inrepair of 36 watt,230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper condctor cable from ceiling roseall as specified and directed
71S&F in repalcement recess type LED Downlight lights 5 W Environmental friendly, energy saving, recess mounted downlighter withelectronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed.
72S&F in repalcement recess type LED Downlight lights 12 W Environmental friendly, energy saving, recess mounted downlighter withelectronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed.
73S&F in repalcement recess type LED Downlight lights 18 W Environmental friendly, energy saving, recess mounted downlighter withelectronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed.
74S&F in repalcement Surface type LED Downlight lights 10 W Environmental friendly, energy saving, recess mounted downlighter withelectronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed.
75S&F in repalcement Surface type LED Downlight lights 12 W Environmental friendly, energy saving, recess mounted downlighter withelectronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed.
76S&F in repalcement Surface type LED Downlight lights 30 W Environmental friendly, energy saving, recess mounted downlighter withelectronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully all as specified and directed.
77S&F in repalcement COB light 12W LED Tiltable surface mounting and Environmental friendly, new generation, energy saving, decorative IP 66all as specified and directed.
78S&Fin repair LED buildingsecurity light fiitting 30 W, IP-65 protection made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC cover having TOP opening seperate driver compartment complete all as specified and directed
79S&F in repair of 12 watt,230V surface and wall mountedwhite LED Mirror Lightincluding connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed Make- Luker LIMR13 3-IN-1 / or equivalent make as mentioned at list of makes in PS
80S&F in repair of 9 watt,230V surface and wall mountedwhite LED Mirror Lightincluding connecting up with twin core twisted flexible copper condctor cable from ceiling rose all as specified and directed
81S&F inrepair Decorative wall mountingWall Lamp with B22 LED 9W and connecting up with twin core twisted flexible copper conductor cable from ceiling roseall as specified and directed
82S&F inrepair Decorative hanging table lamp with B22 LED 9W and connecting up with twin core twisted flexible copper conductor cable from ceiling roseall as specified and directed
83S&F inrepair Decorative hanging with B22 LED 9W and connecting up with twin core twisted flexible copper conductor cable from ceiling roseall as specified and directed
84S&F in repalcement surface/recess mounted 2\" x 2\" LED Panel lights 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving,high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Note: The quoted price shall include the cost of Light and its driver.
85S&F in repair of indoor Profile LED strip of 12 watts/m linear flex ,with separate electronic drivers of suiatble and IP 65 protection complete ,Single phase,with aluminium profile includingmountingon the ceiling as reqd at the site complete all as specified and directedMake: Jaquar/Philips/Havells Note : Cost ofelectronic driver will be measured & paid for separately under respective items of Sch \"A\"
86S&F in repair of outdoorLED strip LED strip of 8 watts/m linear flex,with fixing tape and end capof suiatble and IP 68 protection complete ,Single phase, mountingon the ceiling/wall/piller as reqd at the site complete all as specified and directedMake: Jaquar/Philips/Havells/Luker Note : Cost ofelectronic driver and aluminium profile will be measured & paid for separately under respective items of Sch \"A\"
87S&F inrepair of aluminium profile with accessories includingmountingon the ceiling/wall as reqd at the site complete all as specified and directed
88S&F inrepair of connector outdoorLED strip of 220 Vmountingon the ceiling/wall/piller as reqd at the site complete all as specified and directed
89S&F inrepair of GI pipe bracket of 25 mm dia 1 mtr long bend to shape for street light fitting made out of 25 mm dia GI light grade pipe fixed on building/pole using suitable FI clamp including necessary new nut, bolt and washer complete all as specified and directed.
90S&F in repair of 200 watt integral SMD LED Highbay luminaire with aluminium reflector light fitting incl with inbuilt electronic drivers, necessary hanging arrangements as per site requirement including taking down the existing one all as specified and directedNote: 1. Ladders /Cranes shall be used and will be provided by contractor for dismantling /fixing of light fittings at roof and cost for the same is deemed to be included.Make Luker Cat part no. LOHY200 or equivalent make as mentioned at list of makes in PS
91S&F in repair of 50 watt integral SMD LED Highbay luminaire with aluminium reflector light fitting incl with inbuilt electronic drivers, necessary hanging arrangements as per site requirement including taking down the existing one all as specified and directed Note: 1. Ladders /Cranes shall be used and will be provided by contractor for dismantling /fixing of light fittings at roof and cost for the same is deemed to be included.Make Luker Cat part no. LOHY200 or equivalent make as mentioned at list of makes in PS
92Supply and Fixin repair Electronic Drivers, suitable for 9W, 10W, 20W, 30W, and 40W LED light/security light fittings, of compatible specifications and make as existing, including all necessary connections, testing, and commissioning, complete all as specified and directed
93Taking down copper/aluminium point wiring (light,fan, socket or power) complete, including fixture and fittings suchasswitches,ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
94M&L point wiring with 1.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed cable and including surface, Non metalic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for following :-(a) One light/Fan point controlled by one way switch 6 Amps 240 volts
95Ditto all as per item no.94 above butOne 3 pin 6 Amps socket out let point on independent board.
96Ditto all as per item no. 94 above butOne 3 pin 6 Amps socket out let point on same board.
97Ditto all as per item no. 94 above butOne bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size.
98Ditto all as per item no. 94 above butOne light point controlled by Two 2-way switches
99M&L point wiring with 2.5 sq mm copper conductor FRLSH (multistrand) PVC insulated ISI marked unseathed cable and including surface, Non metalic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unseathed FRLSH cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit complete all as specified and directed
100Supply and fixing in repair ofrigid non-metallic PVC casing capping, double lock type/PVC conduit (ISI marked) of size not less than 25mm, including all necessary accessories (e.g., bends, elbows, connectors, saddles, screws,round plate etc.) for securing loose wiring and repairing/re-routing point wiring and submain wiring, complete as specified and directed by the Engineer-in-Charge.This item Unit rate includes the following: a) Supply of 25mm or larger rigid non-metallic PVC casing capping/conduit (ISI marked). b) Supply of all necessary accessories (bends, elbows, connectors, saddles, screws, etc.).c )Securing loose wiring within the casing/conduit. d) Repairing/re-routing existing point wiring/submain wiring as needed. e) Making necessary connections and terminations.f) Testing of the wiring after completion. Notes: Rates shall include the cost of all materials, labor, tools, equipment, transportation, and any other incidental expenses required for the complete execution of the work.
101Supply and installation of flexible conduit pipes, ivory grey,white in colour, with a minimum internal diameter of 25mm. The conduit shall be of a type suitable for [Specify application, e.g., electrical wiring, data cabling, etc.]. Installation includes cutting, bending (where necessary), and securing the conduit as per the approved design and engineer-in-charge instructions complete all as specified and directed .
102Supply and fixingrepair ofrigid non-metallic PVC cable tray , double lock type (ISI marked) of size not less than 80x40mm, including all necessary accessories (e.g.,Bends (flat, internal, external),Risers,Couplers,Dividers,Support brackets, elbows, connectors, saddles, screws,round plate etc.) for securing loose wiring and repairing/re-routing point wiring and submain wiring, complete as specified and directed by the Engineer-in-Charge.This item unit rate includes the following: a) Supply of80x40mm or larger rigid non-metallic PVCcable tray. b) Supply of all necessary accessories (Bends (flat, internal, external),Risers,Couplers,Dividers,Support brackets, elbows, connectors, saddles, screws,round plate etc..c )Securing loose wiring within thecable tray. d) Repairing/re-routing existing point wiring/submain wiring as needed. e) Making necessary connections and terminations.f) Testing of the wiring after completion. Notes: Rates shall include the cost of all materials, labor, tools, equipment, transportation, and any other incidental expenses required for the complete execution of the work.
103Taking down Careful dismantling and removal of existing sub-main wiring, including cables, conduits, trunking, and all associated fixtures, regardless of type and size.This includes all necessary materials and labor to restore the surfaces to their original condition, or to an agreed upon condition.All work shall be carried out in accordance with the Engineer-in-charge\"s instructions and any relevant project specifications.If the wiring is to be salvaged, great care must be taken during removal complete all as specified and directed .
104M&Lsub main wiring with two single core PVC insulated FRLSHcables with stranded copper conductors 1.5 Sqmm , 1100 Volts grade in and including PVC Conduit/casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm continuous earth wirecomplete all as specified and directed Note: Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping/conduit shall be measured as one RM
105Dittto all as per item no 104 above 2 x 2.5Sqmm
106Dittto all as per item no 104 above 2 x 4 Sqmm
107Dittto all as per item no 104 above 2 x 6 Sqmm
108Dittto all as per item no 104 above 2 x 10 Sqmm
109M&L sub main wiring with Four single core PVC insulated FRLScables with stranded copper conductors 4 Sqmm , 1100 Volts grade in and including casing caping/conduit medium grade not less than 25 mm complete with accessories and copper cable 4 sqmm continuous earth wirecomplete all as specified and directed Note: Four runs of 4 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping/conduit shall be measured as one RM
110Dittto all as per item no 109 above but4 x 6 Sqmm
111S&F in repair factory made epoxy powder coated Distribution Board TP & N 4way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishescomplete all as specifiedNote:MCBs/ MCCBs will be measured and paid seperately under respective Sch A item in the schedule
112S&F in repair MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB\"s 240 voltswith 200 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directedNote - MCBs will be measured & paid separately under respective item of sch A, if required to be replaced.
113Dittto all as per item no 112 above but 08 way SPN DB (Double door)
114Dittto all as per item no 112 above but 04 way SPN DB (Single door)
115Dittto all as per item no 112 above but 04 way SPN DB (Double door)
116Dittto all as per item no 112 above but 02 way SPN DB (Single door)
117S&F inrepair of MCCB with rating of 125 Amps,415Volts 3pole with 16kA breaking capacity,thermal magnetic asdjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity(Icu).MCCBshould be with suitable spreaders and phase barriers for each terminals complete all as specified and directed .
118Dittto all as per item no 117 above but MCCB with rating of 125 Amps,415Volts 3pole with 16kA breaking capacity
119S&F inrepair of C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KAall as specified and directed.
120S&F inrepair of C Curve MCB DP 6-32 Amps working on 240 volts,50 Hz 10 KAall as specified and directed.
121S&F inrepair of C Curve MCB SPN 40-63 Amps working on 240 volts, 50 HZ,10 KAall as specified and directed.
122S&F inrepair of C Curve MCB TP 40-63 Amps working on 240 volts, 50 HZ,10 KAall as specified and directed.
123Supply and fix inrepair of C Curve MCB TPN 40-63 Amps working on 240 volts, 50 HZ,10 KAall as specified and directed.
124S&F in repair sheet metal enclosures Single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts complete with all accessaries etc all as specified and directed
125S&F inrepair sheet metal enclosures Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps, 240 volts complete with all accessaries etc all as specified and directed
126M&L in repair of earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc all as specified and directed
127Dismantling and removing rusted louverssuitable for 150/230/300/450/600 mm sweep exhaust fan S&F inrepair of MS louvers duly painted gray coloured suitable for 150/230/300/450/600 mm heavy duty exhaust fan alongwith four number mounting bracket with bolts, nuts washers etc all as specified and directed
128S&F in repair of GI pipe ceiling fan down rod of 15 mm dia up to 3 feet long for ceiling fan made out of 15 mm dia GI heavy grade pipe fixed on ceiling using suitableclamp including necessary new nut, bolt and washer complete all as specified and directed.
129Taking down ceiling fan/exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as specified and directed.
130Supply only capacitor of 2.5/4 mfd for ceiling fan/exhaust fan.
131Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for exhaust fan/wall mounted fan.
132Disconnecting and taking down existing userviceable geyser of 25/50/100 ltrs capacity of any make/brand, taking it to civil workshop for repairing.Opening the geyser and dismanting all parts and taking out inner tank/container,removing dents making to shape including welding / brazing the leakage portion, filling the portion between inner tank and out casing of geyser with new glass wool heat insulating material . Reassembling and painting the outer casing of geyser with two coats of superior quality synthetic enameled paintand re- fixing to original place all as specified and directed.Note :1.Cost of spares such as Thermostate,heating element etc will be measured and paid for separately under respective Item of sch A as supply only.
133S&F in repair thermostat and cutout set electronic type, temperature adjustable from 0-80⁰C suitable for geyser of 25 to 100 ltrs capacity all as specified and directed.
134S&F in repair heating element of capacity 2/3 KW of any type and shape suitable for Existing 25 to 100 ltrs capacity geysers as per sample provided all as specified and directed
135S&F in repair flow unit (inner pipe assembly) suitable for geyser of 25 ltrs capacity of any brand/make and for vertical/Horizontal type including rubber ring/gasket all as specified and directed.
136S&F in repair metallic flexible hot water connection 600/900 mm long including necessary washers suitable for geysers of 25 to 100 ltr capacity complete all as specified and directed.
137S&F in repair of neon lamp indicator square/round type after taking out old incl taking down old one all as specified and directed.
138S&F in repair NRV valve of size 15mm dia of Brass all as specified and directed
139Removal of the damaged or faulty inner tank from the geyser unit,Supply of a new inner tank of the correct size, material, and specifications, and its installation into the geyser unit. Include all necessary gaskets and seals.Implementation of protective measures to prevent damage to surrounding walls, floors, and fixtures during the inner tank repair all as specified and directed.
140Supply and application of Self Adhesive PVC Electrical Insulation Tape, capable of withstanding temperatures up to [100] °C, Dimensions 7.5 m x 18mmx 0.125mm, for insulating high- temperature electrical connections all as specified and directed.
141S & F in repair of Solar Water Heating System Flat Plate Collector type, size : (2.0 x 1.0) Mtr based on direct transfer of heat of capacity 100 Ltrs Per day with suitable electric backup of 2 KW complete all as specified and directed.Make : Skylark Thermal Energy System
142M & L for cleaning the hot water insulated tank of 100 ltrs capacity of Solar Water Heating System Flat Plate Collector Type by removing the sludge /foreign material from the tank and recifying the fault of water leakages all as specified and directed
143M & L for cleaning the Glass of Solar Flat Plate Collector Panel of size (2.0 x 1.0) Mtr by removing the mud/algee/foreign materials from the panel on half yearly basis all as specified and directed.Note : If any damages occurred to the solar panel during this job, contractor shall be responsible to make good without any extra cost to the deptt.
144Supply and install inrepair of Solar Flat Plate Collector Panel of size (2.0 x 1.0) Mtr, suitable /compatible to existing system complete all as specified and directed.Make : Skylark Thermal Energy System as OEM
145S & F inrepair of composite PEX-AL-PEX pipes as per ASTM F 128-2017 of size inner dia 15 mm and outer dia 20 mm, suitable/compatible to existing system complete all as specified and directed..Make : Kitec or its equivalent.
146Supply and installation in replacementof 16mm outer diameter CPVC pipes, conforming to relevant industry standardsfor [Specify application, e.g., hot and cold water distribution, etc.]. This includes cutting, jointing using approved CPVC solvent cement, and pressure testing as per specifications complete all as specified and directed.
147S & F inrepair of heating element of 3 KW capacity duly ISI marked, 1-ph, 240 volts suitable/compatible to existing solar heating system complete all as specified and directed.
148S & F inrepair Brass/Gun Metal Butterfly gate valve of 15 mm dia, ISI marked, suitable/compatible to extisting system complete all as specified and directed.
149S & F inrepair of SS pipe flange of 15 mm dia or suitable/compatible to existing solar Flat plate collector system including suitable size of nut bolts and washers etc complete all as specified and directed.
150M & L for Glass of Solar Flat Plate Collector Panel of size (2.0 x 1.0) Mtr by removing the existing broken glass and cleaning before installing new complete all as specified and directed.Note : If any damages occurred to the solar panel during this job, contractor shall be responsible to make good without any extra cost to the deptt.
151S&F 15mm bore bib taps, fancy type, cast chromium plated, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
152S & F inrepair of rubber gaskets 15 mm dia or suitable/compatible to existing solar Flat plate collector system complete all as specified and directed.
153S&F electrical meter box compartmentalized design suitable for 1 x energy meter and 1 x four way SPN DB, outdoor wall mounted type, weather proof fabricated out of not less than 2.0 mm thick CRCA sheet, powder coated in siemens grey colour, double door. The enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakelite sheet for mounting the energy meters and MCB DB. The enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables/wires. The overall size of the meter box should be as per site requirement complete with all accessories prewired twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.( For OMQ Qtrs)Note: quoted rate shall deemed toincluding for disconnecting existing circuits from DB\"s and energy meter and same has been refixed in new meter box

AI Tender Summary

OUR REF NO 48971452
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 21-05-2025
Authority
Authority Name Military Engineer Services
Work Description Repair And Maint Of Internal Electrification Including Fans Geysers And Solar Geysers At Appointment Houses Guest House Peacock Bay Mh Mess Jfc Area And Offrs Married Accn At D1 D2 And E3 Area At Nda Khadakwasla
Basic Detail
Tender No 8934/E8
Bidding Type Tender
Location
City khadakwasla
State Maharashtra
Key Dates
Publish Date 02 May 2025
Submission Date 21 May 2025
Open Date 23 May 2025
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
5ffddc2d-cb62-41e1-ac79-4744e83ca8c2.html
BOQ_791313.xls
TENDER1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 02, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
May 21, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 23, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

5ffddc2d-cb62-41e1-ac79-4744e83ca8c2.html

xls

BOQ_791313.xls

pdf

TENDER1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail