|
| 1 | Provision for Conducting Geo-Physical Survey charges. |
| 2 | Sinking of well below water level including all incidental charges using special tools and plants such as air compressor, helmet etc. complete including bailing out of water in silt or clay pocket for 6.00 m internal dia. |
| 3 | Ist depth |
| 4 | IInd depth |
| 5 | IIIrd depth |
| 6 | IVth depth |
| 7 | Vth depth |
| 8 | VIth depth |
| 9 | Supplying and erecting centering for sides and soffits including supports and strutting up to 3.29 m height for plain surfaces such as RCC slabs rectangular beams Tee or L beams lintels, stair case beam etc. in all floors with all cross bracing using mild steel sheets of size 90x60 cm and BG10 gauge stiffended with welded mild steel angles of size 25x25x3 mm for boarding laid over silver oak country wood joists of size 10x6.5 cm spaced at about 90 cm center to center and supported with casurina props of 10 cm to 13 cm dia spaced at 75cm center to center etc. complete complying with standard specification in all floors. (for curved surface) |
| 10 | 0 to 3.30 m |
| 11 | Supplying and erecting shuttering including necessary supports plain surfaces in foundation and basement in all floors for reinforcement cement concrete works such as pedestal bed blocks, staircase steps, RCC column, grade beams, plinth beam etc. using mild steel sheets of size 90x60 cm and B.G. 10 gauge stiffened with welded mild steel angles of size 25x25x3mm for boarding laid over silver oak country wood joists of size 10x6.5 cm spaced at about 90 cm center to center and supported with casurina props of 10 cm to 13 cm dia spaced at 75 cm center to center at suitable intervals etc. complete complying with standard specification. (for square surface) |
| 12 | Supplying, fabricating and placing in position of Steel Reinforcement using Mild steel or ribbed tar steel rods, for all RCC works as per the design given by the departmental officers including cost of steel cutting, bending, placing in position and binding with binding wire and all labour charges for cutting, bending, tying and placing in position etc, complete. |
| 13 | Reinforcement Cement concrete 1:1½:3 (one cement one and a half sand and three aggregates) using machine broken granite jelly of 20 mm size for all reinforced cement concrete works excluding cost of centering shuttering strutting and also cost of reinforcement grill in position but including laying vibrating with mechanical vibrators using finishing etc complete, as directed by the departmental officers etc complete complying with standard specification. |
| 14 | Porous concrete in cement concrete 1:4 (One cement and four hard broken stone of size 20 mm metal) for steening of infiltration well including cost and conveyance of all materials and labour charges etc complete as directed by the departmental officers |
| 15 | Supply and delivery of 7.5 HP submersible pump set having a duty condition of 75 lpm discharge against head of 150 metre confirming to IS specification with ISS marking suitable for installation panel board including cost of all materials and all conveyance charges etc complete as per standard specification. |
| 16 | Supply and delivery of wall mounting type control panel board of Ammeter, Voltmeter single phase prevents insulator-indicating lambs, STAR DELTA / DOL starter. Suitable for 7.5 HP suitable certificate pump set including all charges. |
| 17 | Labour charges for the erection of submersible pump set in bore well / open well including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges up to the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pump set and trail run for 10 days. |
| 18 | Supply and delivery of flat type 6 sq mm PVC sheathed 3 core conductor cables conforming to IS 694 / 1990 with ISI marking suitable for submersible pump sets etc complete. |