Tender For Dismantling And Shifting Of 2 X 7 Tr Precision Type Pac Units From Old Ocb, Ctx And Itc At Txn Room, Third Floor, Te Attingal
Tender Value
3.77 Lakhs
Estimated cost
Bid Submission
13 May 2025
0 days left
EMD
7550
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
attingal → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Dismantling And Shifting Of 2 X 7 Tr Precision Type Pac Units From Old Ocb, Ctx And Itc At Txn Room, Third Floor, Te Attingal Pac Ac Shifting Work
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of the existing 7 TR Package AC (Precision) unitinstalled in IInd floorof Central Telephone Exchange, TVM, both indoor and out door unitsalong with required accessories, supports, required qty of condensor platform, piping, cables, cable trays including removing the foundation / mounting bolts, removing electrical cable connections, supply air connections, Drain line connections and Refrigerent line connections,including pumping down of refrigerent gas to the extent possiblewithout any damage, as directed by the Engineer in charge as required. |
| 2 | Shifting and Transportation ofthe above dismantled Package type precision AC unit , both indoor and out door unitalong with its accessories like refrigerant pipe, supports, condensor platform, cables, trays etc from Second floor of Central Telephone Exchange, TVM toTE Attingal i/c loading from the respective locations, unloading at TE Attingal, shifting of indoor units and accessories toTXN Room in Third floor,shiftingand positioning of the Outdoor Unit and condensor platform to the designated area in third floor, withoutmaking damages to the unit/ buildingetc as required. Note: The job includes arranging necessary scafoldings / chain block arrangements, tools etc as required for shifting and positioning of the Indoor /Outdoor Units and nothing extra will be paid on this account |
| 3 | Servicing of the existing 7 TR Package AC (Precision) units including cleaning of Fine and Coarse filters of the indoor unit, water cleaning of condensor unit, through cleaning of the indoor and outdoor units, lubrication of bearings of evaporator, condensor fan etc complete as required. (Except supply of consummables like cleaning agents and grease, supply of spares not included in the scope of this item) |
| 4 | Installation , testing and commissioning of microprocessor controlled 7 TR High precision package AC units complete with indoor and outdoor unit with all components and controls etc.fixing the indoor unit on the existing MS Stand i/c modifying and fixing the existing MS stand, if required, P/F anti vibration pads, installing the shifted outdoor platform, installation of outdoor unit on the platform, i/c Pressure testing, vaccumising, purging etc as per standards, checking the units for all functional parameters, checking of refrigerant lines and cable connections , satisfactory testing of the unit etc as required ( Note 1:- Each 7 TR Unit is having one indoor unit with two compressors of 3.5 TR and one single circuit Outdoor unitwith three fans) |
| 5 | Supplying and fixing of copper refrigerant piping of minimum 18 G thick and suitable diameter as per industry standards and manufacturer\"s recommendations for the Precision PAC unit for hot gas and liquid lines of a single circuit, with all accessories and including cutting, jointing, brazing etc.in existing MS perforated trayi/c insulating the refrigerant lines inside the AC area with suitable fire retardant polythene foam etc complete as required as per specifications attached .(Measurement shall be taken on linear basis for hot gas and liquid linetogether of a single circuit) |
| 6 | Supplyand filling suitable refrigerant gas recommended by the manufacturer etc as required |
| 7 | Relaying the existing copper refrigerant piping available at site ( Hot gas and liquid line together) including cutting, bending, jointing, brazing, providing extra necessaryaccessories as required , painting etcfor a single refrigerant circuit, on the existing MS cable tray including insulating the refrigerant lines inside AC area with suitable fire retardant polyurethane foam etc complete as required |
| 8 | Relaying the existing MS cable tray of size 200 mm/300 mm/450mm width after necessary alteration, including, cutting, welding, fixing, dedusting,removing rust ,providing all accessories, painting etc complete as required. |
| 9 | Supplying and laying armoured copper cable of following size in the existing cable tray/surface of wall i/c end terminations with brass compression glands and copper lugs, making connections etc. as required. |
| 10 | 4x6 sq.mm |
| 11 | 3x2.5 |
| 12 | Relaying of following size PVC insulated, armoured cableavailable at siteon surface of wall/ existing tray includingend terminations with brass compression glands and copper lugs connection etc as required |
| 13 | 4x6 Sqmm |
| 14 | 3x2.5 Sqmm |
| 15 | Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular ducting complete with neoprine rubber gasket, elbows, hangers supports etc as per approved drawings and specifications of following sheet thickness complete as required |
| 16 | 0.8 mm |
| 17 | 1.0 mm |
| 18 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required |
| 19 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 20 | Supplying and fixing of following Members for Modification of existing Iron Structure workavailable at site (Shifted from CTX) for installing Indoor / Outdoor units / Hand rails / Mesh etcincluding, cutting, welding, painting etc. as required. (Design shall be got approved from Engineer - in - Charge before commencement of work) |
| 21 | 40mm x x40mm x 5mm MS Angle |
| 22 | 50 x 5 mm MS Flat |
| 23 | 32 mm Dia B Class GI Pipe |
| 24 | 40 mm Dia B Class GI Pipe |
| 25 | GI Wire mesh with mesh size 0.5 to 1 sq Inch and wire thickness not less than 4 mm |
| 26 | S/F of single Phase, 230 VAC, 50 Hz, outdoor duty, axial flow condensor fan motors suitable for the existing 7 TR Precision type PAC units including dismantling the old fan motor, installing the new motor testing commissioning etc as required |
| 27 | Providing and fixing following heavy duty rigid PVC pipes of suitable size with all accessories and supports including painting etc. complete as reqd. |
| 28 | Drain pipe 40mm |
| 29 | Supplying and fixing of following ways surface/ recess mounting, Vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 30 | 4 way (4 + 12), Double door |
| 31 | Supplying and fixing Following rating 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 32 | Four Pole 63 A |
| 33 | Tripple Pole 32 A |
| 34 | Demolishing of following type brick work manually / by mechanical means including stacking of servicable materials and disposal of unserviceable material within 50 meters lead as per direction of Engineer - in - charge. |
| 35 | In cement mortar (External envelope of the building on the third floor). NB: Dismantling and removing of debris shall be done with utmost care so as to cause no damage to the building, or the adjecent buildings or the occupants of the buildings |
| 36 | Providing plastering to the cut edges of the wall using 1 : 4 cement mortar to a neat finish including painting the plastered area with distember matching with the wall colour including supplying of all materials |
AI Tender Summary
Tender Timeline
May 01, 2025
11:30 IST
Tender Published
Tender notice published.
CompletedMay 13, 2025
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 14, 2025
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer