Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-05-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-05-2025 |
| 2 | 09-05-2025 | Corrigendum01 | BOQ | 22-05-2025 |
| Sl. No. | Item Description |
| 1 | Labour for repair/servicing of ceiling fan of any capacity complete with strip opening of ceilling fan for repair/cleaning/varnishing and removing of old lubricating substances from bearing/ bush by using Kerosine oil, carrying out fresh lubrication , greasing andto make the ceiling Fan noise free and smooth functioning, including replacement of worn out/unserviceable minor spare parts split pin,fan body bolts,spring washer,fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired ceiling fan andtesting to the entire satisfication of engineer in charge and refifixing in its orginal position all as specified and directed.Note: - Replacement of Spares flexible wire etc/rewinding of ceiling fan/shall be measured and paid seperately under respective item as supply only for material and labour cost. |
| 2 | Description all as per Srl item No. 1 here-in-before but for exhaust fan of any type and any sweep complete all as specified and as directed. |
| 3 | Rewinding ofceiling fan, of any make/type and size (1200 sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufactures specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stater/rotor, connection and testing complete all as specified and as directed. |
| 4 | Rewinding ofceiling fan, of any make/type and size (1400 sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufactures specification, including replacement of all insulationmaterials, varnishing, heating, drying, assembling of stater/rotor, connection and testing complete all as specified and as directed. |
| 5 | Description all as per Srl item No. 4.00 here-in-before but for exhaust fan of any make/type but of size 300 mm sweep complete all as specified and as directed. |
| 6 | Description all as per Srl item No. 4.00 here-in-before but for exhaust fan of any make/type but of size 450 mm sweep complete all as specified and as directed. |
| 7 | Labour for remetalling of worn out shaft of fan, cutting,bracing,machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in repair of bushing system in ceiling fan and assembling the same and testing to the entire satisfaction of Engineer-in-Charge to ensure smooth and noise free operation (bearing shall be measured and paid seperately) complete all as specified and as directed. |
| 8 | Supply only ball bearing of any size and type, suitableforceiling fan complete all as specified and as directed. |
| 9 | Description all as per item No. 8.00 here-in-before but for exhaust fan of any type/make and size complete all as specified and as directed. |
| 10 | Supply only capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and Rated capacity 2.5 MFD for ceilling fan and exhaust fan complete all as specified and as directed. |
| 11 | Description all as per item No. 10.00 here-in-before but of rated capacity 3.15 MFD for Ceiling fan and Exhaust Fan complete all as specified and as directed. |
| 12 | Supply only PVC insulated, unsheathed multistranded, three core twisted copper flexible cable of size 1.5 Sqmm as required complete all as specified and as directed. |
| 13 | Supply only bush of suitable size for exhaust fan of any type/size as per existing type complete all as specified and as directed. |
| 14 | Supply only PVC connector 4 way 6 Amps with connection screws, nuts complete all as specified and as directed. |
| 15 | Supply only PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and as directed. |
| 16 | Supply only GI/ MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole complete all as specified and as directed. |
| 17 | Supply only MS clamp for down rod of suitable size including gromet / reeltype rubber pad with bolts, nuts, split pin and washers suitable for housing ceiling fan complete all as specified and as directed. |
| 18 | Supply only ceiling fan down rod 12 mm dia and 30/45 cm long complete with MS Clamp rubber reel, split pin nut bolts etc. complete all as specified and as directed. |
| 19 | Supply only Printed circuit board (PCBs) suitable for BLDC ceiling fans of 1200 mm complete all as specified and as directed.Notes for Ser Item No 8.00 to 19.00: - Labour component is deemed to be included in unit rates quoted by biddewr in respect of Ser item No\"s 1.00 and 2.00 (as applicable) here-in-before. |
| 20 | Supply and fixing in repair of louver shutter made out of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made of MS flat strips of size 25mm x 3mm includidng heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall at ground/First/Second floor etc complete with using fastener bolt,driling for exhust fan up to 400 mm sweep incl taking down old one complete all as specified and as directed. |
| 21 | Cleaning of ceiling fan assembly of any type/size and carrying out two coats of spray painting with first quality synthetic enamelled paint of approved colour complete all as specified and as directed. |
| 22 | Description all as per Ser item No. 21.00 here-in-before but for exhaust fan upto 450 mm complete all as specified and as directed. |
| 23 | Supply only PVC Canopy set of two pieces for ceiling fans of any size complete all as specified and as directed. |
| 24 | Supply only ceiling fan blade set of three pieces suitable for 1200/1400 mm sweep of White/Brown/Ivory colors complete all as specified and as directed. |
| 25 | Taking down old unserviceable copper/aluminium point wiring concealed / batten (light,fan, socket or power) complete, including fixture and fittings such as switches, sockets,ceiling roses, regulators, switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 26 | Material and labour for point wiring for one light/fan/call bellpoint controlled by one 5 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into concealed PVC rigid/steel conduit and CI/pressed steel terminal boxes including 3.00mm thick hylum brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed.Notes: - (a) wiring shall be done by using proper colour coding(b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge.(d) Rates are inclusive of cutting chassis and making good to disturbed surfaces in cement mortar. |
| 27 | Supply only switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and as directed. |
| 28 | Supply only stepped type electronic fan regulator flush type , 120 watt , 240 volts complete all as specified and as directed. |
| 29 | Material and labour in repair for Sub main wiring with proper colour coding , insulated , unsheathed , multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and as directed.Note: - (a) Wiring shall be done in proper colour coding.(b) Rates are inclusive of cutting chassis and m,aking good to disturbed surfaces in cement mortar. |
| 30 | Supply and fixing in repair MS hooks for hanging ceiling fan with down rod and fix the same down the roof of suitable size complete all as specified and as directed. |
| 31 | Taking down and strip opening to geyser of any make and capacity 25 / 35 / 50 ltrs including disconnection of all water pipe connection and taking out water inlet / outlet assembly, removing glass wool, the inner tank, descaling the assembly and tank, detecting the leakage, welding / brazing the defective parts, repacking the glass wool and refixing the same after making it functional including replacement of worn out nuts, bolts, washers etc complete all as specified and as directed.Note: - Defective parts shall be measured and paid under respective items as supply only. |
| 32 | Supply only water inlet and outlet geyser assembly of existing make as required at site with rubber gasket suitable for geyser of 25 / 35 ltrs capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc complete all as specified and as directed. |
| 33 | Supply only thermostat, switch for electric water heater storage type of capacity 25 / 50 ltr, 230 Volts of existing make of geyser complete all as specified and as directed. |
| 34 | Supply only heating element with triangular base / round base, single phase, 230 Volt, capacity 2 KW of existing make complete all as specified and as directed. |
| 35 | Supply only heating element with triangular / round base, single phase, 230 Volt, capacity 1.5 KW of existing make complete all as specified and as directed. |
| 36 | Supply only pressure release valve conforming to relevant IS 15mm bore suitable for fixing with GI pipe / tubing 15mm bore complete all as specified and as directed. |
| 37 | Supply only heavy duty PVC connection (For Hot water) nylon threaded 450mm large (18\") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed. |
| 38 | Supply only heavy duty PVC connection (For Cold water) nylon threaded 450mm large (18\") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed. |
| 39 | Supply only indicator lamps round / rectangular type 230 Volt AC suitable for geyser of any capacity including providing electric connections complete all as specified and as directed. |
| 40 | Supply only water storage inner tank of stainless steel heavy duty confirming to ISI suitable for 25 ltrs capacity geyser, with provision for fixing 15mm dia galvanized air release valve complete all as specified and as directed.Notes for Ser item No 32.00 to 40.00: - Labour component is deemed to be included in unit rates quoted by bidder in respect of Ser item No 31.00 of BOQ. |
| 41 | Supply and fixing in repair MCB SP 32 Amps, 240 Volts, rupturing capacity 10 KA, \"B\" series complete all as specified and as directed. |
| 42 | Material and labour in repair Non return Valve 15mm dia, made up of brass complete all as specified and as directed. |
| 43 | Supply only water storage inner tank of stainless steel heavy duty confirming to ISI 50 ltrs capacity geyser with heating element assembly 2 KW triangular type, thermostat, indicators, 15mm dia galvanized air release valve, suitable to fix any type of water heating geyser of capacity 25 Ltrs complete all as specified and as directed.Notes for Ser item No 43.00: - Labour component is deemed to be included in unit rates quoted by bidder. |
| 44 | Repair / maintenance / servicing to solar water heater system having a capacity 100 to 200LPD complete with descaling / cleaning to flat plate, collector plate, solar heater water tanks, toughened solar glass panels, welding / breazing to solar tanks, Repair / rectification of leakage in inlet / outlet water tubing GI, checking and repair to electric system, Repair of water make up tank and make the system function cable after repair / servicing and rectification of the fault complete with and including replacement of minor spare parts complete all as specified and as directed.Note: - The spares replaced shall be measured and paid under respective items as supply only. |
| 45 | Supply only union medium grade 20mm dia complete all as specified and as directed. |
| 46 | Supply only rubber hose pipe with MS clamp of suitable size complete all as specified and as directed. |
| 47 | Supply only metal gate / globe valve 20mm dia complete all as specified and as directed. |
| 48 | Painting to steel structure base frame of solar water heater of 100 to 300 LPD capacity complete all as specified and as directed. |
| 49 | Supply only float valve PVC 20 mm dia complete all as specified and as directed. |
| 50 | Supply only toughened glass panel suitable for 200 LPD solar water heater complete all as specified and as directed. |
| 51 | Supply only electrical heating element threaded type 3 KW, single phase suitable for solar water heater complete all as specified and as directed. |
| 52 | Supply only fasteners 80 -100mm long for fixing of geyser of capacity upto 50 ltrs including grouting completed works in wall as per site requirement with the floor complete all as specified and as directed. |
| 53 | Supply only chromium plated bib cock 15mm dia conforming to ISI complete all as specified and as directed. |
| 54 | Supply only gun metal glove / gate valve 15mm dia internal threaded with iron wheel head conforming to ISI complete all as specified and as directed.Notes for Ser item No 45.00 to 47.00 and 49.00 to 54.00: - The labour component shall be deemed to be included in unit rates quoted by bidder in respect of Ser Item No 44.00 above. |
| 55 | Material and labour in repair of tubing GI \"medium grade\" with all fittings laid in floor or trenches including taking out old unserviceable pipe of size 15mm dia complete all as specified and as directed. |
| 56 | Material and labour in repair of tubing GI \"medium grade\" with all fittings laid in floor or trenches including taking out old unserviceable pipe of size 20mm dia complete all as specified and as directed. |
| 57 | Material and labour for fixing in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, fixing on wall suitable for geyser connection complete all as specified and as directed. |
| 58 | Material and labour in repair of Rotational moulded polyethylene water storage tanks of 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and as directed. |
| 59 | Material and labour in repair of submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required 2x6.0 sq. mm + 1x 6.0 sq. mm earth wire complete all as specified and as directed. |
| 60 | Material and labour for repair/Maint to desert coolers complete with and including cleaning,scrapping/ rubbing old rusted surface ,filling cavities and painting with two coat of high quality aluminium paint over a coat of red oxide primer externaly and black paint internally with synthetic enamelled paints complete with replacement of necessary nut,bolts,rubber pads for fan motors and writing MES No/unit name complete all as specified and as directed by the Engineer-in-Charge. |
| 61 | Supply and fixing in repair of desert cooler fan motor copper wound 90 watt,1400 RPM,3 speed,230 volt 50 Hz single phase conforming to ISI complete with fan blade and capacitor of suitable size complete all as specified and as directed. |
| 62 | Supply and fixing in repair of Desert Cooler submersible pumping set single phase 230 volt , 50 Hz of 0.25 HP conforming to ISI complete with lead complete all as specified and as directed. |
| 63 | Supply and fixing in repair of desert cooler fan motor blade of existing size made out from MS heavy duty complete with key bolt complete all as specified and as directed. |
| 64 | Supply and fixing in repair cable PVC insulated and sheathed of size 1.0 sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI complete all as specified and as directed. |
| 65 | Supply and fixing in repair cable PVC insulated and sheathed of size 1.5 sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI complete all as specified and as directed. |
| 66 | Supply and fixing in repair cable PVC insulated and sheathed of size 2.5 sqmm 3 core FRLS 230 volt, 50 Hz conforming to ISI complete all as specified and as directed. |
| 67 | Supply and fixing in repair of plug top 3 pin 5 Amp 230 volt 50 Hz complete all as specified and as directed. |
| 68 | Supply and fixing in repair of plug top 3 pin 15 Amp 230 volt 50 Hz complete all as specified and as directed. |
| 69 | Supply and fixing in repair of Desert Cooler ON/OFF rotary selector switch of suitable size for speed controller complete all as specified and as directed. |
| 70 | Supply and fixing in repair of unserviceable Khas Khas/Grass pad for desert cooler Set of three pieces complete all as specified and as directed. |
| 71 | Repair/ Maint/ Servicing to refrigerator/ deep freezer/ water coolers/ AC\"s of any capacity and model by replacing capillary tubing, gas chargings, rectification of leakage in capillary tubing/ Chiller plant/ water tanks, condensing coils, repair to wiring, flushing/ cleaning condensing/ cooling coils/ internal/ External unit of split AC, greasing to blower motors, replacement of spare parts, fan belts and make refrigerator/ deep freezer/ water coolers/ AC\"s in serviceable condition complete all as specified and as directed by Engineer-in-Charge.Note:- Spare/ Gas charging shall be paid separately as supply only under respective items of BOQ. |
| 72 | Supply only sealed compressor unit, seamless welding, as per manufacturer with refrigerent gas conforming to relevant ISI as under:- |
| 73 | For refrigerator 165/286 Ltr capacity |
| 74 | For refrigerator 290/320 Ltr capacity |
| 75 | For Deep Freezer 100/200 Ltr capacity |
| 76 | For Deep Freezer 300/400 Ltr capacity |
| 77 | For Water Cooler 40/80 Ltr capacity |
| 78 | For Water Cooler 60/120 Ltr capacity |
| 79 | Split/Window AC 1.5 Ton Capacity |
| 80 | Supply only condensing fan motor 1/5 HP 1440 rpm Single phase 230 Volt 50 HZ with double blade and shaft end with fan belts for windows AC/Split AC conforming to ISI of capacity 1.5/2.0 ton complete with vibration parts etc. complete all as specified and as directed. |
| 81 | Supply and charging refrigerant 134a/412a in sealed compressor unit of refrigerator/deep freezer/water coolers/AC\"s of any type and capacity after flushing the complete system with carbon tetrachloride (CTC) and vacuumise the complete system with vacuum pump and testing on full load including replacement of filter, strainer complete all as specified and as directed. |
| 82 | Supply only starting relay for refrigerator/ deep freezer/ water coolers/ AC\"s of any capacity. |
| 83 | Supply only overload protector for refrigerator/ deep freezer/ water coolers/ AC\"s of any capacity. |
| 84 | Supply only Thermostat switch for refrigerator/ deep freezer/ water coolers/ AC\"s of any capacity. |
| 85 | Supply only Defroz switch for refrigerator/ deep freezer/ water coolers/ AC\"s of any capacity. |
| 86 | Supply only starting capacitor 45 mfd for water cooler. |
| 87 | Supply only running capacitor 60/120 mfd for water cooler. |
| 88 | Supply only push cock chromium plated 15 mm with nipple 6\"\" long for water cooler.Notes for Ser item No 72.00 to 72.16: - The labour component shall be deemed to be included in unit rates quoted by bidder in respect of Ser Item No 71.00 above. |
| 89 | Taking out old / unserviceable water cooler and Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 60/120 liters complete all as specified and as directed. |
| 90 | Taking out old/unserviceable voltage stabilizer and Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA complete all as specified and as directed. |
| 91 | Taking out old/unserviceable keeping away from site, depositing to MES Store and Supply, installation, commissioning of Metal Top Deep Freezer Double door 320 liters, single phase 240 volt, 50 Hz complete all as specified and as directed. |
| 92 | Taking out old/unserviceable and Supply and fix refrigerator, electric driven (single phase), capacity 185/190 Litres, BEE 5 star rated, 240 V, 50 Hz complete all as specified and as directed. |
| 93 | Material and labour in repair/maintenance/servicing to DG Setinstalled at pump house/site complete with entire cleaning checking of fuel pipe, lub oil pipe, rubber hose, panel wiring, fan belt, earthing strip, nut, bolts, exhaust pipe, battery pads, radiator hose, measuring instruments and tightening all nuts, bolts, MS rubber hose clamps and to make the system leak proof and serviceable complete with including replacement of fuel filter elements all types as under and minor spare parts, nuts, washer, radiator top cap, battery terminal brass bolts type and changing engine oil incl cleaning to oil sump and testing on full load after servicing, of capacities as under: -Note: - Spare parts shall be measured and paid separately as supply only under respective items of BOQ. |
| 94 | 15 KVA to 40 KVA |
| 95 | 63 KVA to 100 KVA |
| 96 | 100 KVA to 200 KVA |
| 97 | Supply only fuel filter primery with \"O\" ring for DG set of capacity: - |
| 98 | 15 KVA to 40 KVA |
| 99 | 63 KVA to 100 KVA |
| 100 | 100 KVA to 200 KVA |
| 101 | Supply only fuel filter secondary with \"O\" ring for DG set of capacity: - |
| 102 | 15 KVA to 40 KVA |
| 103 | 63 KVA to 100 KVA |
| 104 | 100 KVA to 200 KVA |
| 105 | Supply only lub oil filter with \"O\" ring for DG set of capacity: - |
| 106 | 15 KVA to 40 KVA |
| 107 | 63 KVA to 100 KVA |
| 108 | 100 KVA to 200 KVA |
| 109 | Supply only lub oil by pass filter with \"O\" ring for DG set of capacity: - |
| 110 | 15 KVA to 40 KVA |
| 111 | 63 KVA to 100 KVA |
| 112 | 100 KVA to 200 KVA |
| 113 | Supply only air cleaner element for DG set of capacity: - |
| 114 | 15 KVA to 40 KVA |
| 115 | 63 KVA to 100 KVA |
| 116 | 100 KVA to 200 KVA |
| 117 | Supply only fan belt set for radiator, alternator and water pump etc. for DG set of capacity: - |
| 118 | 15 KVA to 40 KVA |
| 119 | 63 KVA to 100 KVA |
| 120 | 100 KVA to 200 KVANotes for Ser item No 77.01 to 83.03: - The labour component shall be deemed to be included in unit rates quoted by bidder in respect of Ser Item No 77.00 above. |
| 121 | Supply only battery lead copper heavy duty having length 1.5 mtr each complete with one side banjo bolt and other side brass battery terminal bolt type (set of 2 pcs) of suitable size complete all as specified and as directed. |
| 122 | Supply only rubber hose pipe for radiator, water pump, set of 01 RM complete with MS clamp of suitable size complete all as specified and as directed. |
| 123 | Repair/ servicing of self starter 12 volts DC complete with and including replacement burnt/unserviceable spare parts, clutch assembly, carbon brush, solenoid switch, plunger, armature and refix in repairing for DG set of capacity: - |
| 124 | 15 KVA to 40 KVA |
| 125 | 63 KVA to 100 KVA |
| 126 | 100 KVA to 200 KVA |
| 127 | Dismantling/repair/over hauling of water pump assembly of DG set by replacing defective part like pump, shaft, impeller CI, mechanical seal, water set gasket, hub for pulley, set screw, bearing grooves nuts, spacers and spring washer and metling /machine work if any and refix in repairing after repair, for DG set of capacity: - |
| 128 | 15 KVA to 40 KVA |
| 129 | 63 KVA to 100 KVA |
| 130 | 100 KVA to 200 KVA |
| 131 | Dismantling/repair/over hauling of charging alternator (dynamo) of DG setand replacement of unserviceable/defective parts like carbon brushes, bearing, pulley, spacer, commutator assembly, armature, washer etc. and refitting after repair for DG set of capacity: - |
| 132 | 15 KVA to 40 KVA |
| 133 | 63 KVA to 100 KVA |
| 134 | 100 KVA to 200 KVA |
| 135 | Material and labour for engine oil servo super grade 20/40W of indian oil including cleaning of oil sump thoroughly complete all as specified and as directed. |
| 136 | Dismantling/taking down radiator assembly for repair/servicing of DG set and carry out complete internal cleaning, brazzing to tubing and rectification of leakage and refitting including replacement of minor spare parts like inlet/outlet rubber hose with MS clamps, pipe for thermostate to radiator washer, nut, bolts all as specified and directed of following capacity: - |
| 137 | 15 KVA to 40 KVA |
| 138 | 63 KVA to 100 KVA |
| 139 | 100 KVA to 200 KVA |
| 140 | Disconnecting FIP pump of DG set of following capacity and carry out complete servicing/calliberation from authorised service centre, and refitting after calibration including replacement of injector nozzle, delivery valvs, gasket, fuel pump gear, flange assembly, plunger, copper washer, adaptor, set both etc. as required to make the FIP serviceable: - |
| 141 | 15 KVA to 40 KVA |
| 142 | 63 KVA to 100 KVA |
| 143 | 100 KVA to 200 KVA |
| 144 | Supply and fixing in replacement self starter 12 volts, copper wound suitable for DG set125 to 200 KVA complete all as specified and as directed. |
| 145 | Supply and fixing in repair of battery charger heavy duty, 150/180 AH, 24 volts with lead, volt/Amp meter complete all as specified and as directed. |
| 146 | Supply and fixing in repair set of high pressure of fuel pipe of engine complete nut, set volt, clamp and spring washer etc complete all as specified and as directed. |
| 147 | Supply and fixing in repair of oil sump gasket complete all as specified and as directed. |
| 148 | Supply and fix in repair of water temp switch suitable for DG set upto 200 KVA complete all as specified and as directed. |
| 149 | Supply and fixing in repair of AVR suitable for DG set upto 200 KVA complete all as specified and as directed. |
| 150 | Supply and fixing in repair of diode and rectifier for alternator suitable for DG set upto 200 KVA complete all as specified and as directed. |
| 151 | Supply and fix in repair of OFF load open execution change over switch 4 pole 415 volts 100 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fix in repairing on wall and angle iron bracket of size 40x40x6mm thick as per size requirement or complete all as specified and as directed. |
| 152 | Supply and fix in repair of OFF load open execution change over switch 4 pole 415 volts 160 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fix in repairing on wall and angle iron bracket of size 40x40x6mm thick as per size requirement or complete all as specified and as directed. |
| 153 | Supply and fix in repair of OFF load open execution change over switch 4 pole 415 volts 200 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fix in repairing on wall and angle iron bracket of size 40x40x6mm thick as per size requirement or complete all as specified and as directed. |
| 154 | Labour for Dismantling to alternator from the engine of DG set of following capacity by opening nut and bolt and transport to work shop for repair/maint and rewinding with supper enameled heat resistent copper winding wire of existing size and nos of turn complete with insulating material i.e. varnishing,bamboo strips,cotton thread/tape,leather paper etc and drying the winding complete with checking,realignment,welding,grinding,earth work and polishing the alternator rotor shaft and refitting the alternator with engine after repair/rewinding and testing on full load all as specified and directed.Note: - Copper winding wire will be measured and paid separately. |
| 155 | 15 KVA to 40 KVA |
| 156 | 63 KVA to 100 KVA |
| 157 | 100 KVA to 200 KVA |
| 158 | Supply only ball bearing of alternator heavy duty conforming to ISI suitable for DG set alternator upto 200 KVA complete all as specified and as directed. |
| 159 | Dismantling all incoming/outgoing electric connection carefully of transformer, voltage stabilizer, LT panel, switch, change over etc and repair the cable, fix in repaired properly with proper aluminium thimble/lugs including preparation of cable end for jointing (incoming/outgoing cable connection for each cable will be measured as one job each). thimble shall be measured separately under respective items complete all as specified and as directed. |
| 160 | Labour for disconnecting all incomming /outgoing electric connction carefully of fully automatic servo voltage stabilizerand transport to work shop for repair/servicing and including,dismantling top cover of stabilizer and taking out the coil,drain out the transformer oil and refilling after dehydration of transformer oil,cleaning internaly, incl replacement of unserviceable body nut, bolts, washers, top gasket of cork sheet 6mm thick,replacement of internal circuit wiring if any suitable size of copper wire and painting of stabilizer with heat resistant smoke grey synthetic enameled paint including preparation of old rusted surfaces and writting MES NO, SM MES No, capacity, Ser No, Location etc and reinstallation/ connecting electric connection with replacement of proper size Aluminium lugs and testing on full load at site, of following capacity: - |
| 161 | 30 KVA to 50 KVA |
| 162 | 125 KVA to 200 KVA |
| 163 | Supply and fix in repair synchronous motor single phase 230 Volt suitable for servo voltage stabilizer having capacity of following capacity: - |
| 164 | 30 KVA to 50 KVA |
| 165 | 125 KVA to 200 KVA |
| 166 | Supply and fix in repair PCB suitable for servo voltage stabilizer having capacity: - |
| 167 | 30 KVA to 50 KVA |
| 168 | 125 KVA to 200 KVA |
| 169 | Supply and fix in repair dimmer motor suitable for servo voltage stabilizer capacity: - |
| 170 | 30 KVA to 50 KVA |
| 171 | 125 KVA to 200 KVA |
| 172 | Supply and fix in repair toggle On/Off switches for stabilizer capacity: - |
| 173 | 30 KVA to 50 KVA |
| 174 | 125 KVA to 200 KVA |
| 175 | Supply and fix in repair Volt meter 0-500 Amp 96mm squre type 3 phase 230 volt 50 Hz complete all as specified and as directed. |
| 176 | Supply and fix in repair Ampere meter 0-400 Amp, 96mm square type 3 phase 230 volt 50 Hz with CT of suitable ratio complete all as specified and as directed. |
| 177 | Supply and fix in repair selector switch for volt/Ampere meter suitable for capacity upto 200 KVA complete all as specified and as directed. |
| 178 | Supply and fix in repair gun metal Gate or Globe valve 20 mm for drain out of oil complete all as specified and as directed. |
| 179 | Supply and fix in repair unserviceable brass/gun metal stud bush suitable for 30 KVA to 200 KVA complete with connecting rod of suitable lenth and dia with necessary nut, bolt, washer, bushing packing to prevent the leakage from bushes and necessary connection complete all as specified and as directed. |
| 180 | Dehydration of Transformer oil and dielectric strength of oil achieved not to be less than 40 KV at 2.5 mm gap complete all as specified and as directed. |
| 181 | Supply and filling of new tranformer oil for top up upto Automatic servo voltage stabilizer including heating and dielectric strength not to be less than 60 KV complete all as specified and as directed. |
| 182 | Taking out main coil of voltage stabilizer for repair/rewinding with super enamaled copper winding wire of existing gauge including PVC insulated sheet sleeve,varnishing etc all as required and refix in repairing to the stabilizer after testing all as required at site or complete all as specified and as directed by Engineer-in-Charge. |
| 183 | Supply and fix in repair MCCB TPN250 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu, overload adjustable short circuit adjustable type including complete connection all as per direction of Engineer-in-Charge. |
| 184 | Supply and fix in repair MCCB TPN160 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu, overload adjustable short circuit fix in repaired type including complete connection all as per direction of Engineer-in-Charge. |
| 185 | Supply and fix in repair MCCB TPN100 Amps, 415 Volts, 16 KA, 4 POLE, Ics=100% Icu, overload adjustable short circuit fix in repaired type including complete connection all as per direction of Engineer-in-Charge. |
| 186 | Supply and fix in repair MCCB TPN63 Amps, 415 Volts, 10 KA, 4 POLE, Ics=100% Icu, overload adjustable short circuit fix in repaired type including complete connection all as per direction of Engineer-in-Charge. |
| 187 | Taking out old/unserviceable keeping away from site, depositing to MES Store and Supply and fix refrigerator, electric driven (single phase), capacity 285 Litres, BEE 5 star rated, 240 V, 50 Hz complete all as specified and as directed. |