Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-08-2025 | 80235 Corrigendum No. 14 date | Date | 28-08-2025 |
| 2 | 12-08-2025 | 80235 Corrigendum No. 13 | Financial Bid | 25-08-2025 |
| 3 | 08-08-2025 | 80235 Corrigendum No 12 | BOQ | 25-08-2025 |
| 4 | 08-08-2025 | 80235 Corrigendum No. 12 | BOQ | 25-08-2025 |
| 5 | 05-08-2025 | 80235 Date Corrigendum No. 11 | Date | 25-08-2025 |
| 6 | 29-07-2025 | 80235 Date Corrigendum No. 10 | Date | 14-08-2025 |
| 7 | 21-07-2025 | 80235 Date Corrigendum No. 9 | Date | 07-08-2025 |
| 8 | 15-07-2025 | 80235 Date Corrigendum No. 8 | Date | 31-07-2025 |
| 9 | 08-07-2025 | 80235 Date Corrigendum No. 7 | Date | 24-07-2025 |
| 10 | 01-07-2025 | 80235 Date Corrigendum No. 6 | Date | 17-07-2025 |
| 11 | 23-06-2025 | 80235 Date Corrigendum No. 5 | Date | 10-07-2025 |
| 12 | 18-06-2025 | 80235 Date Corrigendum No. 4 | Date | 03-07-2025 |
| 13 | 10-06-2025 | 80235 Date Corrigendum No. 3 | Date | 26-06-2025 |
| 14 | 03-06-2025 | 80235 Date Corrigendum No. 2 | Date | 19-06-2025 |
| 15 | 28-05-2025 | 80235 Date Corrigendum No. 1 | Date | 12-06-2025 |
| Sl. No. | Item Description |
| 1 | Schedule \"A\"PART - I : PRE-ENGINEERED BUILDING (PEB) HANGAR WITH ANNEXES are not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. |
| 2 | Design and Construction of Pre-Engineered Building Hangar of size 60mx45m (clear size excluding steel stanchions/ columns), 10m height with RCC pile foundation, RCC framed structure up to plinth level including plinth beam along with Annexes on either side of the hangar with RCC pile foundation and RCC framed structure with RCC roof, AAC block masonry, etc. complete all as specified and as shown on drawings and as directed. Details in brief are as given below:(A)Main PEB Hangar (i) Excavation in hard and dense soil(ii) PCC 1:4:8 type D2 as in foundation concrete(iii) Sub Structure : RCC M-30 design mix and epoxy coated reinforcement in piles, pile caps, columns & plinth beam. ATT treatment, RFR, filling under floor etc.(iv) Super structure: Superstructure is to be of steel PEB (as shown in drawing), PEB Structure is to be designed duly considering the Design parameters and soil investigation report attached as Appendix \"A\" & Appendix \"B\" to Schedule \"A\" respectively. Galvalume sheet wall cladding with over lap of 150 mm shall be provided to enclose the front and rear side of hangar. Motorized Hangar gates of size as shown on drawing shall be designed to withstand the wind loads. |
| 3 | (v) Roof & cladding:Galvalume sheet roofing 0.5mm TCT, coated with camouflage pattern fixed to the structural steel sections as per manufacturer\"s instructions (vi) Flooring : Flooring inside hangar shall be of Anti static flooring over 220mm thick PQC with flexural strength of 45 Kg/cm² over 1.0mm thick transparent polythene sheet over 10 mm thick sand cushioning over 125 mm thick dry lean concrete of M-10 grade over 150 mm thick WMM in two layers each layer of compacted thickness of 75 mm thick over 200 mm thick granular sub base over compacted/rammed sub base, including forming dummyjoints 6-8 mm wideand 100 mm deep by sawing and filled with sealing compound, including forming expansion joints filled with 20-25 mm thick approvedjoint filer board and sealed with sealing compound including construction joint 10 mm wide and 25 mm deep including sealing compound all complete as specified.(vii)Plinth protection of PCC 1:3:6 type C2 over 100 mm thick hard core on rear side only |
| 4 | (B) ANNEXES(G+1)(i) Excavation in hard and dense soil(ii) PCC 1:4:8 type D2 as in foundation concrete(iii) Sub Structure : RCC M-30 design mix and epoxy coated reinforcement in piles, pile caps, columns & plinth beam etc, ATTtreatment RFR, filling under floor etc.(iv) Superstructure : RCC framed structure in M-30 mix design with RCC roof, AAC block wall;and with finishes, UPVC windows/ ventilators, wooden doors,and all finishes as shown Sch of finishes drg. |
| 5 | Schedule \"A\" Part – I-A to Schedule \"A\" Part – XV:NOTE: Schedule \"A\" Part – I to Part – XV are prepriced by MES. Bidders shall insert their Lump sum amount in Green coloured field under Column - 6 only |
| 6 | Lump sum price worked out by the contractor for \"Buildings & Structures\",as listed in Schedule \"A\" Part – I-A |
| 7 | Lump sum price worked out by the contractor for \"EARTH WORK AND SITE CLEARANCE\",as listed in Schedule \"A\" Part – II |
| 8 | Lump sum price worked out by the contractor for \"INTERNAL WATER SUPPLY\",as listed in Schedule \"A\" Part – III |
| 9 | Lump sum price worked out by the contractor for \"INTERNAL ELECTRIC SUPPLY, AVIATION OBSTRUCTION LIGHT\",as listed in Schedule \"A\" Part – IV |
| 10 | Lump sum price worked out by the contractor for \"EXTERNAL WATER SUPPLY\", as listed in Schedule \"A\" Part – V |
| 11 | Lump sum price worked out by the contractor for \"EXTERNAL ELECTRIC SUPPLY, STANDBY POWER SUPPLY\", as listed in Schedule \"A\" Part – VI |
| 12 | Lump sum price worked out by the contractor for \"SEWAGE DISPOSAL\",as listed in Schedule \"A\" Part – VII |
| 13 | Lump sum price worked out by the contractor for \"AREA DRAINAGE, SUB SURFACE DRAINAGE\", as listed in Schedule \"A\" Part – VIII |
| 14 | Lump sum price worked out by the contractor for \"DISPERSAL/ TAXI TRACK\",as listed in Schedule \"A\" Part – IX |
| 15 | Lump sum price worked out by the contractor for \"ROAD/ PATH/ CULVERT\",as listed in Schedule \"A\" Part – X |
| 16 | Lump sum price worked out by the contractor for \"FIRE FIGHTING, FIRE DETECTION AND FIRE ALARM SYSTEM\",as listed in Schedule \"A\" Part – XI |
| 17 | Lump sum price worked out by the contractor for \"TV & TELE SOCKET & CONDUIT\",as listed in Schedule \"A\" Part – XII |
| 18 | Lump sum price worked out by the contractor for \"LIGHTNING PROTECTION\",as listed in Schedule \"A\" Part – XIII |
| 19 | Lump sum price worked out by the contractor for \"COOLING APPLIANCES\",as listed in Schedule \"A\" Part – XIV |
| 20 | Lump sum price worked out by the contractor for \"PILE FOUNDATION FOR BUILDINGS/ STRUCTURES OTHER THAN PEB HANGAR & ANNEXES\",as listed in Schedule \"A\" Part – XV |
| 21 | Schedule \"A\" Part - XVI: [Miscellaneous Items] [Internal Water Supply, Internal Electric Supply & Aviation light, External Water Supply, External Electric Supply, Standby Power supply, Sewage Disposal, Area drainage & sub surface drain, Dispersal/ Taxi track, Road/ Path/ Culvert, Fire fighting, fire detection & fire alarm system, TV & Tele socket & conduit, Cooling appliances, Pile foundation, Motorised MS sliding gate, Washing pump, Air conditioning, Swivel lights, Boom barrier] |
| 22 | S&F Bib taps, Two-way, 15mm bore, cast copper alloy, fancy type, chromium plated with crutch handle, long body with wall flange, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed. |
| 23 | S&F Heavy duty (Fully Metal construction) wall mount Air Circulator fan 450mm sweep, 1440 rpm, 4 speed control with regulator, single phase, 230 volts AC, 50 Hz consisting of powerful circulator motor with spiral guard design ensures high air thrust, high torque gear box with safety clutch, broad blade profile for low noise, resettable thermal overloaded protector, oscillating mechanism including making electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete, fixed to PEB structural members with suitable clamping arrangement all as specified and directed. |
| 24 | S&F Wall mounted fan 400mm sweep, 230V, AC with built-in regulator and swing function including electric connection from ceiling rose to fan connector with PVC insulated 2 core copper cable of size 0.75 sq.mm complete, fixed to PEB structural members with suitable clamping arrangement or building walls all as specified and directed. |
| 25 | S&F Modular white cover plate with frame 10 Module for mounting modular type switch/ sockets |
| 26 | S&F Modular white cover plate with frame 12 Module for mounting modular type switch/ sockets |
| 27 | S&F Modular white cover plate with frame 16 Module for mounting modular type switch/ sockets |
| 28 | S&F sheet steel powder coated distribution board Vertical type TPN 4 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting MCCB/ RCCB up to 160 Amps as incomer and MCBs as out going complete fixed flush to the wall surface all as specified and as directed.[Note: MCCB/ RCCB & MCBs shall be measured and paid separately] |
| 29 | S&F sheet steel powder coated distribution board Vertical type TPN 12 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting MCCB/ RCCB up to 160 Amps as incomer and MCBs as out going complete fixed flush to the wall surface all as specified and as directed.[Note: MCCB/ RCCB & MCBs shall be measured and paid separately] |
| 30 | S&F Next generation, energy saving, environment friendly & robust design high bay LED light fitting of 200W with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy up to 300 lm/W complete including hanging arrangement from ceiling to maintain 8m height from FFL with suitable clamping & down rodincluding connecting up with suitable size three core copper conductor cable all as specified by Engineer-in-charge. |
| 31 | M&L for 1.1 kV grade copper conductor, PVC insulated, PVC sheathed cable conforming to IS 7098 (Part 1): 1988, having stranded copper compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, size 3 core 4 sq.mm including necessary clamping / dressing with cable ties and termination complete all as specified and directed by Engineer-in-charge. |
| 32 | S&F of 200 mm X 50 mm X 1.6 mm (L X D X T) size of perforated painted with powder coating MS cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with MS suspenders including bolts, etc. complete all as specified and directed by the Engineer-in-charge. |
| 33 | Supply and fixing Integral LED aviation light 12 W comprising of aluminium housing with polycarbonate enclosure with connection by suitable size 3 core copper flexible wire to the nearest available electric connection complete all as specified and as directed. |
| 34 | M&L for 1.1 kV grade copper conductor, PVC insulated, PVC sheathed cable conforming to IS 7098 (Part 1): 1988, having stranded copper compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, size 3 core 2.5 sq.mm including necessary clamping / dressing with cable ties and termination complete all as specified and directed by Engineer-in-charge. |
| 35 | S&F PP-R gate valve with brass insert, 90mm outer dia and fixed complete all as specified and directed. |
| 36 | Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental typeLT Panel of suitable size, conforming to IEC 61641, having front side openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. |
| 37 | PANEL-X (P1)The LT Panel shall comprise of the following:[A] BUS BAR CHAMBER[i] 01 Set (3L + N) of Aluminium bus bar of rated capacity 600 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connectionINCOMER :-(i) 400 Amp MCCB 4 Pole, 415 V, with Microprocessorrelease with breaking capacity 50 KA- 01 NoOUTGOING :-(i) MCCB250A 4P-3 Nos(ii)Digital type Ammeter, range 0 to 630 Amp with selector switch and CT -01 No(iii)Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01 No (iv)Indicator lamp RYB-01 set |
| 38 | Supply, installation, testing and commissioning of factory made, CPRI type tested, outdoor, cubical compartmental typeLT Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 3.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. |
| 39 | PANEL-A(P1)The LT Panel shall comprise of the following:[A] BUS BAR CHAMBER[i] 01 Set (3L + N) of Aluminium bus bar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connectionINCOMER :-(i) 250 Amp MCCB 4 Pole, 415 V, with Microprocessorrelease with breaking capacity 50 KA- 01 Nos OUTGOING :-(i) MCCB 160A 4P 415V -2 No(ii) MCB SPN 40A- 1 No(iii) MCB SPN 32A - 5 Nos(iv)Digital type Ammeter , range 0 to 400 Amp with selector switch and CT -01 No(v)Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01 No (vi)Indicator lamp RYB-01 set |
| 40 | Supply, installation, testing and commissioning of factory made, CPRI type tested, outdoor, cubical compartmental typeLT Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 3.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. |
| 41 | PANEL-B(P1)The LT Panel shall comprise of the following:[A] BUS BAR CHAMBER[i] 01 Set (3L + N) of Al bus bar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connectionINCOMER :-(i) 320 Amp MCCB 4 Pole, 415 V, with Microprocessorrelease with breaking capacity 50 KA- 01 Nos OUTGOING :-(i)MCCB250A 4P 415V-2 Nos.(ii)MCB SPN 32A230V.-2 Nos(iii)MCB TPN 63A 415 -2 Nos. (iv)Digital type Ammeter , range 0 to 400 Amp with selector switch and CT -01 No(v)Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01 No (vi)Indicator lamp RYB-01 set |
| 42 | Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental typeLT Panel of suitable size, conforming to IEC 61641, havingfront side openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. |
| 43 | BUILDING PANEL-1 (ALH) & BUILDING PANEL-2 CHETAK SQUADRONThe LT Panel shall comprise of the following:[A] BUS BAR CHAMBER[i] 01 Set (3L + N) of Al bus bar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connectionINCOMER :-(i) 250 Amp MCCB 4 Pole, 415 V, with Microprocessorrelease with breaking capacity 50 KA- 01 Nos OUTGOING :-(i) MCB TPN 63A 4P 415 V-8 Nos.(ii) MCB TPN 40 A 415 V-3 Nos(iii) MCB SPN 32 A ,230V-3Nos(iv)Digital type Ammeter, range 0 to 400 Amp with selector switch and CT -01 No(v)Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01 No (vi)Indicator lamp RYB-01 set |
| 44 | Supply, installation, testing and commissioning of factory made, CPRI type tested, outdoor, cubical compartmental typeLT Panel of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 3.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the engineer-in-charge. |
| 45 | Ext. light FEEDER PILLAR(OUTDOOR TYPE)The LT Panel shall comprise of the following:[A] BUS BAR CHAMBER[i] 01 Set (3L + N) of Al bus bar of rated capacity 200 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connectionINCOMER :- (i) MCB 63A FP 10 KA - 01 No.OUTGOING :- (i)MCB TP 25A 10 KA - 12 No.(ii)24 hour real timer for auto switching of load. - 06 No.(iii)Digital type Ammeter, range 0 to 200 Amp with selector switch and CT -01 No(iv)Digital type Volt meter, range 0 to 500 Volt with selector switch and PT-01 No (v)Indicator lamp RYB-01 set |
| 46 | Note for Item 31 to 35(i) Breaking capacity of MCCB and MCB shall be used as follows:(a) up to 125 A-16KA (b) 160A to 630 A -36KA(ii) Over load release of MCCB/MCB shall be used as follows:(a) up to 125 KA -Adjustable thermal release (0.7 to 1.0 In)(b) 160Ato 250 A-Adjustable thermal release (0.64 to 1.0 In)(c)400A to 630 A- Electronic release with over load zone of adjustment 0.4 to 1.0In(ii) Short circuit release of MCCB/MCB shall be used as follows:(a) up to 125 KA -Fixed magnetic type suitable for 10.0In(b) 160Ato 250 A-Adjustable magnetic release (3.5 to 10.0 In)(c)400A to 630 A- Electronic release with short circuitzone of adjustment 1.5 to 10.0In (Adjustment current with time) |
| 47 | S&F Hot dip Galvanized Octagonal street light Poles of 7.0 meter long, Top dia 70mm , bottom dia 130mm and sheet thickness 3mm including top bracket for light fitting complete with base frame plate, foundation bolt, nut and washers, top etc. Window- Plasma cut and duly chamfered opening window of 300 x 110 mm for terminal connection and mounting accessories with suitable capacity MCBs. Window cover is fitted with allen screws to the pole complete all as specified and directed by Engr-in-charge. |
| 48 | Design, supply, installation, testing and commissioning of LED elevated Omni Directional Taxi way Edge Lights with Blue 1W and Blue Lens, Breakable Coupling, Base Plate with Gasket, Suitable to operate with 2.8A, 6.6 AmpsInput complete . |
| 49 | Supply, Installation testing and commissioning of 5Kv grade isolation transformer -15 W 6.6/6.6 Amp complete. |
| 50 | Supply & installation of CI Transformer housing box 330mm dia X 450 mm Height for installation of elevated taxiway edge light complete. |
| 51 | Supply, Installation, testing & commissioning of 5 kv grade primary connector Kit suitable for 1C X 6 Sq.mm Aviation cable complete. |
| 52 | Supply, Installation, testing & commissioning of 5KV Grade, PVC Insulated, PVC sheathed copper conductor Primary Cable of size 1C x 6 Sq.mm complete. |
| 53 | Supply and lay 6 SWG GI earth wire complete. |
| 54 | Supply, installation, testing & commissioning Thyristor controlled constant current regulator (CCR) of capacity 4 KVA at 6.6 Amps output with 5 brightness stages complete. |
| 55 | S&F of 400 mm X 50 mm X 1.6 mm (L X D X T) size of perforated painted with powder coating MS cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with MS suspenders including bolts, etc. complete all as specified and directed by the Engineer-in-charge. |
| 56 | Supply, erect, testing & commissioning 15 Mtrs High Mast with following specifications and accessories:High mast sections with base plate, Lantern carriage suitable to fix 6 Nos of luminaries of capacity up to 210w. High mast accessories : Double drum winch, motor, SS wire rope 6mm dia (7/19 construction) (Grade-AISI 316), trailing cable, L-Stopper (03 Nos), the mast shall have integral power tool installed inside the base compartment for electric/ manual operating handle, motor mounting plates, lightning arrestors and earthing spikes (MS/GI), Junction box , galvanized lantern carriage arrangements suitable for 6 luminaires symmetrically with Double dome aviation obstruction light LED Type & control feeder pillar boxwith timer suitable for high mast along with necessary copper cable from timer/ control panel to high mast for motor and luminaires including necessary reinforced cement concrete foundation M-30 Grade (Design Mix) complete all as directed |
| 57 | Supply, installation, test and commissioning of silent, Diesel engine driven factory assembled, floor mounted generating set of capacity 250 KVA/200 KW at 0.8 power factor or nearest higher size, 3 phase, 4 wire, 50 Hz, 1500 RPM as per IS 10001/10002 to take 10% over load complete with safety control and metering equipments mounted on & including common base frame with acoustic enclosure (canopy), weather proof as per Latest CPCB norms, powder coated all as per manufacturer\"s instructions manual and all as specified and comprising of the items/ accessories listed hereinafter:- |
| 58 | (A) Prime Mover :Directly coupled diesel engine, water cooled suitably de-rated of matching BHP for driving 250 KVA capacity, alternator electric start, four stroke confirming to latest IS-10001/10002 for continuous running and capable for taking 10% over load for 01 hour complete with following accessories:-(i)Fly wheel to suit flexible coupling.(ii)Flexible coupling with guards.(iii)Air cleaner with filters.(iv) Lubricating oil filter(v)Heavy duty radiator assembly with fan.(vi)Anti-vibration pad as recommended by manufacturers.(vii)PT pump with electronic governor of suitable capacity.(viii)Self starter 12 volts DC.(ix)Necessary arrangement for charging battery.(x)Maintenance free battery12 volts , duly charged -01 No, capacity as supplied by manufacturer and as recommended by manufacturer along with flexible copper battery lead and connector. |
| 59 | (xi)Battery rack made out of MS angle iron 40 mm x 40 mm x 5 mm & 150 mm height - 01 No.(xii)Standard safety device. (xiii)Daily services fuel tank for full running capacity of DG set for min 12 hours enclosed within the canopy all as per CPCB with lever indicator inlet, fuel outlet drain plug, air vent and locking arrangements etc including fuel pipe connections with connected GI pipe medium grade from fuel tank to DG set and over flow from the DG set to fuel tank complete with gate valve.(xiv) Exhaust system with Retrofit emission control device as per CPCB norms shall be provided with thermal insulation by using fire retardant/ non igniting foam conforming to BS-4735 to prevent excess heat radiation on the engine and safe for operator.(xv)Mechanical panel having following accessories :-(aa)Digital Lubrication oil temperature gauge - 01 No.(ab)Digital Lubrication oil pressure gauge - 01 No.(ac)Digital Water temperature gauge - 01 No.(ad)Starting switch with key - 01 No.(ae)Battery voltmeter. |
| 60 | (af)Indicator lamp etc.(ag) Digital Ammeter DC-01 No.(ah) Digital RPM meter-01 No.(aj)Safety measures :(i)Low lubricant oil pressure trip. (ii)High coolant temp trip. (iii) Engine over speed trip. (iv) Battery charging alternator. (v) Emergency stop pressed.(B)Alternator : 250KVA at 0.8 power factor, self regulated 3 phase with neutral 415 volts 50 Hz 1500 RPM as per IS : 13364 complete with automatic voltage regulator and foot mounted including making cable connection. The salient feature of alternator are as under :- |
| 61 | (i)Voltage regulation under static condition + 1.5%.(ii)Class \"F\" insulation.(iii)Permanently lubricating bearing.(iv)Capable to take 10% over load for one hour for every 12 hours. (C)Repair tools and 2 years maintenance spare parts as per following:-Repair Tools :- (i) Ring spanner set of 10- 01 set. (ii) Screw driver 6”, 8”, 12”, 14” & 24”-02 each (iii) Spanner setof 01- 01 set. (iv) Adjustable spanner 12” – 04 Nos.(v) Cutting pliers – 01 No.(vi) Tacho meter- 01 No. (vii) Tools kit box (only box) – 01 No 2 Years Spare :-(a)Fan belt set complete - 01 No(b) Lub oil filter- 01 Set(c) Fuel filter- 01 Set |
| 62 | (d) Service manual and spare part catalog with guarantee card (e ) Sock treatmentchartdully framed - 01 Set(f) First Aid Box- 01 No(g) Fire extinguisher foam- 01 set(h) Fire extinguisher (electricity )- 01 set |
| 63 | (E)ACOUSTIC ENCLOSURE :-OEM made Acoustic enclosure (canopy) suitable for 250 KVA DG with the following provisions/ specifications :-(i)The enclosure fabricated out of CRCA sheet of 14 SWG suitable to accommodate the DG Set properly.(ii)Thesheet metal components shall be hot dip seven tank pretreated.(iii) It is pure polyester based powder coated (inside as wall as outside).All nuts/bolts/hardware are zinc coated with salt spray test as per ASTMB- 117.(iv) Battery shall be accommodated in a tray in the enclosure.(v)The doors shall be fitted with gasket with high quality EPON gasketed to avoid leakage of sound.(vi) Sound proofing of enclosure shall be done with high quality rock wool/ mineralwool conforming to IS 8131 of 50 mm thickness and density of 96 kg/cum.(vii) The wool is further covered with fiber glass cloth and perforated powder coated sheet, insulation level conforming to UL 94 HF1 class flammability.(viii)A special residential silencer is provided within the enclosure to control exhaust noise.(ix) Specially designed alternators are provided to control sound at air entry to the container and exhaust from the container.(x)Adequate ventilation is provided to meet requirement for combustion and heat removal.If required a blower is used to meet total air requirement and air changes. |
| 64 | (xi) Temperature of enclosure does not exceed beyond50°C of ambient temperature. (xii) The enclosure shall be provided with “high enclosure temperature” safety device. (xiii) There shall be provision of emergency shutdown from out side the enclosure.(xiv)There shall be arrangement for proper illumination inside the canopy. (xv)Noise level shall be 75 DB (A) at 1 mtr distance. (xvi)Approved by CPCB.Note :- (i)The quoted rate for DG Set is inclusive of PCC foundation.The foundation for DG Set shall be made of PCC 1:2:4 type B1 using 20mm graded stone aggregates below the floor level minimum 300mm and 300 mm above floor platform and of suitable size as per manufacturers recommendations complete all as directed by Engineer-in-Charge. |
| 65 | (ii) The DG Set shall be suitable derated to suit the climatic condition of so as to give desired output including 10% over load.(iii)The DG Set shall be suitable for auto main failure function.(iv) AMF panel (not included and will be measured & paid separately) shall be of same manufacturer as that of DG Set manufacturer (v) The DHPP (fuel) required for testing of DG sets is deemed to be included in above quoted rate .(vi) Phase I test will be carried out by Engineer-in-charge for no load and 100% load for 1 hour each and phase II test will be carried out in presence of SEI/EI/IEM/Rep of Accepting officer for no load, 25%, 50%, 75%, 100% for 11 hours and 110% for 1 hour over load.(v) CPCB Norms :- DG Set shall be as per Latest CPCB Norms. |
| 66 | Supply, installation, test and commissioning ofControl AMF Panel :AMF control panel inside the floor mounted acoustic enclosure. Suitable for 250 KVA DG set with by pass assessment including all necessary operating and control device (to meet the requirement of above capacity plus 25% over load) such as contactors, MCCBs, CT\"s, volts meter, Ammeter, indicating lamp, frequency meter, energy meter with protection fuses for panel instrument battery charging system with indicator and cut off relays low and high oil pressure, high speed over load and earth fault protection, reverse current protection duly wired copper conductor cable and cable connection with lugs/thimbles complete as recommended by manufacturers and as directed. |
| 67 | Supplying & laying HDPE pipes, Double wall corrugated (DWC) in trenches with necessary specials complete all as specified and directed for 150 mm internal dia of pipes. |
| 68 | Supplying & laying HDPE pipes, Double wall corrugated (DWC) in trenches with necessary specials complete all as specified and directed for 250 mm internal dia of pipes. |
| 69 | S&F SFRC manhole cover and frame (Heavy duty HD- 20 grade designation) internal size 0.9m dia circular/ 1.2x0.90m rectangular conforming to IS 12592, fixed in cement concrete 1:2:4 (using 20mm graded stone aggregate) including necessary form work complete all as specified and directed. |
| 70 | S&F for SFRC medium duty precast concrete cover slab of Size 600x740mm and thickness of 150 mm, frame & grating to withstandTest Load of 10 MT as per IS 12592 Part – I & II MHCF-18 all as directed. |
| 71 | S&F for SFRC medium duty precast concrete cover slab of Size 600x600mm and thickness of 80 mm, frame & grating to withstandTest Load of 10 MT as per IS 12592 Part – I & II MHCF-17 all as directed. |
| 72 | Supply & laying of 160.8mmouter Diaperforated HDPE pipe as sub surface drain including but fusion welding for jointing complete including necessary bends, Tees etc as directed. |
| 73 | Supply and filing of non-woven,Geo textile havingMin weight 285 gm/Sq.m, max apparent opening size 0.22 mm as per Table 700-3 of MoRTH 5th Revision and minimum geo textile strength property as per installation condition of Type-III of Table 700-1 of MoRTH 5th Revisioncomplete all as specified and as directed. [Note: Net area excluding the overlaps at joints shall be measured and paid] |
| 74 | M&L for Filter media with crushed stone aggregate as per MoRTH 5th Revision Table300-3(Class-01 grading) and complete as specified and directed by Engr-in charge. |
| 75 | Supplying and Laying ofPolypropylene (PP) Bi-axial Geo grid, made from virgin high density polypropylene, with an aperture size of 38mm x 38mm, LCR of 1.35 andjunction efficiency of at least 90%. The geo grid shall have an installation damage resistance of 95% and Provide tensile strengths of 10.5KN/m at 2% strain and 21 KN/M at 5% strain, making it suitable for base reinforcement application. The installation shall be completed in accordance with the approved drawings, technical specificationas per manufacturer\"s technical instructions and as directed by the Engr-in- charge. [Note: Net area excluding the overlaps at joints shall be measured and paid] |
| 76 | M&L for preparation of new bituminous/ concrete, flexible or Rigid surfaces over 10 cm width and applying two coats of water based runway marking paint(White/ Golden yellow) over a coat of primer as in lines/dashes, arrows, letters etc. with necessary painting rollers, all as specified and as directed. |
| 77 | S&F reflective convex mirror of dia 800mm and mounted over mild steel pipe 40mm bore and 2.50mtr long including erection in position in PCC 1:2:4 Type B-1 size 450x450x900mm including excavation in post holes as required complete all as directed. |
| 78 | S&F speed breaker made of ABS material, two highly reflective reflectors moulded in PMMA material are welded with ABS through ultrasonic welding process and then fixed on the speed breaker of size 350mm(W) x 50mm(H) x 500mm(L). The whole breaker is fixed along with epoxy and hardener and bolts complete all as specified and as directed. |
| 79 | M&L for providing and laying at or near ground level factory made kerb stone with saucer of M-40 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 80 | Providing & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps, steel support) of suitable dia for the engine. The pipe shall be provided with 12 mm thick supercera ceramic fibre rope |
| 81 | S&F 25mm dia gun metal air release valve with all fittings and forged ball valve on header complete as required and as directed |
| 82 | M&L for applying anti corrosive pipe wrapping tape of approved colour on MS pipes of dia up to 200mm complete all as directed. |
| 83 | Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type Motor Control Center (MCC) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation(1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary control wiring with PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed by the Engineer-in-charge. |
| 84 | The MCC shall comprise of the following:[A] BUS BAR CHAMBER[i] 01 Set (3L + N) of copper bus bar of rated capacity 500 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection[B] INCOMING[i] 200 A, 415 V, Ics = 100% Icu =25 kA, 50 Hz FP MCCB, conforming to IEC 60947-2- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs, On hrs & interrupts- 01 Nos.[iii] LED phase indicators (Red, Yellow, Blue)- 01 Set[C] OUTGOING[i] 160 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz FP MCCB, conforming to IEC 60947-2- 01 Nos. [for electric driven main fire pump][ii] Fully automatic digital soft starter suitable for electric driven main pump having adaptive acceleration control, built-in RTD & thermistor inputs, programmable auto start/stop, emergency run operation, fully programmable overload trip, etc. complete with contactors, push button, LED type indicators, auto/manual selector switch, current sensing type single phase preventer complete with all accessories and wiring etc.- 01 Nos. [for electric driven main fire pump] |
| 85 | [iii] 32 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz FP MCCB, conforming to IEC 60947-2 01 Nos. [for jockey pump][iv] Fully automatic DOL starter, suitable for the jockey pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.- 01 Nos. [for jockey pump][v] Control for diesel engine comprising of automatic / manual selector switch & three attempts starting device, timers and relays as required, push buttons, start / stop in manual mode, indicating lamp for high / low lubrication oil pressure, high water temperature and engine on indication, battery charger suitable for 12 V / 24 V DC with boost and trickle selector switch, 0- 30 V DC voltmeter and 0-20 A DC ammeter complete with all standard relays and accessories for automatic operation of the diesel engine - 01 Nos. [for diesel engine pump][vi] 32 A, 10 kA, 230 V, 50 Hz, SPN MCB- 01 Nos. [vii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interrupts- 02 Nos.[viii] LED phase indicators (Red, Yellow, Blue)- 02 Set |
| 86 | NOTES: [i] The Panel shall be purchased from the original equipment manufacturer (OEM) only.[ii] The contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, GADs, etc. for approval of the GE before placing order. |
| 87 | M&L for low smoke zero halogen (LS0H) fire survival control cables of the following size with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete all as specified and directed by the Engineer-in-charge: |
| 88 | 2 core, 2.5 mm² (for instrumentation) |
| 89 | 3 core, 2.5 mm² (for auto start/stop panel) |
| 90 | 12 core, 2.5 mm² (for diesel engine pump) |
| 91 | M&L for 1.1 kV grade copper conductor, XLPE insulated armoured cable conforming to IS 7098-1: 1988, having stranded copper compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanized steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by the Engineer-in-charge for the following size: |
| 92 | 3 core, 35 mm² |
| 93 | 3 core, 6 mm² |
| 94 | Supply and installation of ISI marked portable fire extinguishers CO₂ type 3 ltrs capacity and dry type chemical powder -5 kgwall mounted type, wall brackets complete in all respect, including fixing on walls complete all as specified and directed. |
| 95 | Supply and fixing of fire point comprising the following :-(a) Fire extinguisher dry chemical powder (ABC) Type 5 Kg capacity - 01 No.(b) Fire extinguisher CO₂ type5 Kg capacity - 01 No.(c) Ceiling hook - 01Nos(d) Fire man Axe - 01 Nos(e) Mechanical Foam 9 Litre -02 Nos |
| 96 | Supply and fixing of trolley mounted fire point comprising the following :-(a) Fire extinguisher mechanical foam type 50 ltr capacity - 01 Nos(b) Fire extinguisher dry chemical powder (ABC) Type 25 Kg capacity - 01 No.(c) Fire extinguisher CO₂ type25 Kg capacity - 01 No.(d) Fire extinguisher dry chemical powder (ABC) Type 5 Kg capacity - 01 No.(e) Fire extinguishers CO₂ type 3 ltrs capacity -01 no |
| 97 | Supply and fixing of steel conduit 25mm dia along with accessories in surface/recess including painting in case of surface conduit complete including necessary specials, fixing clamps etcas required. |
| 98 | S&F Telephone socket - double RJ11 - 1 module complete all as specified and directed |
| 99 | S&F Lan/CCTV Information socket - category 6-UTP - 1 module complete all as specified and directed |
| 100 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete. |
| 101 | M&L for Boring for Bored cast -in-situ piles 500mm dia in any strata except hard rock using DMC method (Direct mud circulation) or any other approved method and getting out and disposal of spoil to a place out side MD land complete all as specified and as directed. |
| 102 | M&L for Boring for Bored cast -in-situ piles 500mm dia through hard rock strata by any approved method duly supported by drilling fluids or casing pipesand getting out and disposal of spoil to a place out side MD land complete all as specified and as directed. |
| 103 | M&L for carrying out non destructive integrity test on 500mm dia piles all as per IS-14893-2001 or ASTM Std and all as specified including bringing all the required T&P on to site and removal of the same on completion of testing |
| 104 | M&L for carrying out initial load test (vertical load test)on 500mm dia piles all as per IS-2911 (Part-IV) - 2013 and all as specified including bringing all the required T&P on to site and removal of the same on completion of testing |
| 105 | M&L for carrying out lateral load test on 500mm dia piles all as per IS-2911 (Part-IV) - 2013 and all as specified including bringing all the required T&P on to site and removal of the same on completion of testing |
| 106 | M&L for carrying out pull out test on 500mm dia piles all as per IS-2911 (Part-IV) - 2013 (Part-I Sec 2) and all as specified including bringing all the required T&P on to site and removal of the same on completion of testing |
| 107 | M&L for carrying out routine load test (static load test)on 500mm dia piles all as per IS-2911 (Part-IV) - 2013 (Part-I Sec 2) and all as specified including bringing all the required T&P on to site and removal of the same on completion of testing |
| 108 | Supply, installation, testing and commissioning of Motorized powder coated MS telescopic gate of clear size 25m wide & 2.4m height, CE certified as per EN 13241 - 1: 2003+A1.2011, with 3 leafs of single side sliding with high precision sprocket and chain mechanism with option of partial opening including necessary sliding channels at bottom, SS 304 wheels, necessary SS bolts & nuts and necessary civil work as required complete with following specifications:(i) Design: standard tubular design(ii) Gate frame: MS tubular section of minimum 72x72x3.2mm thick(iii) Internal members: MS tubular section of minimum 32x32x2mm thick with 150mm c/c(iv) Full height column: MS tubular section of minimum 72x72x3.2mm thick(v) Bottom rail: Single track polished bright bar 20mm dia rail welded over bottom I beam ISMB 100x50 (SS304 bottom roller)(vi) Bottom rollers: Single track heavy duty bottom rollers with dual bearing mechanism for free sliding movement fixed at the bottom member of the gate frame(vii) Drive comprising: Electric motor of adequate capacity single/ three phase 50/60 Hz, inbuilt magnetic limit switch, inbuilt control panel, Protection class IP54, CE certified(viii) provision for emergency operation with rotating release device easy to operate & key protected(ix) Surface finish: powder coating |
| 109 | Supply and install washing pump with 3.2 KW single phase motor with jet pump of model: VK 2160 TS of make: Kranjile or equivalent complete including necessary cable connections and piping all as directed. |
| 110 | Design, Supply, Installation, testing and commissioning of variable refrigerant flow (VRF) Modular type condensing units of not less than 50 TR (variable as per design) for Annex Buildings of Hangar, each comprising of all inverter driven scroll High COP compressors, low noise propeller, Condenser coil with resistance to salt corrosion; the outdoor shall be full charge of green refrigerant gas (R-410a/ R-407), lubricating oil and all accessories as per the specifications. The system shall have refrigerant cooled/ lead free PCB, all necessary safety devices shall be provided to ensure safe operation of the system, unit should be equipped witha highly efficient oil separation system to ensure stable operation with long refrigerant piping. The condensing units shall be suitable to work up to 53°C on cooling mode only. Quoted price shall be inclusive of factory provided anti salt corrosion coating for air-cooled condensers. The condensing units shall be suitable for smooth operation on 415 ± 10% volts, 50Hz, 3 phaseACpower supply, 24x7 working, Minimum COP should be 3.4 at 100% load and 6.86 at 50% load condition for cooling in standard AHRI test condition, outdoor unit system should not have any duration in cooling capacity up to 39°C ambient temperature complete with mountingarrangement as per manufacturer standards. The VRF plant to be placed at terrace. |
| 111 | Note: (a) The schematic layout of building for copper pipe line & cables from Outdoor unit to four way cassette indoor units as per site condition to be prepared and submitted to GE(I) for approval prior to execution of work. The cost of same shall deemed to be included in quote rate. (b) Construction of Civil foundation for mounting the outdoor unit at terrace shall deemed to be included in quote rate.(c)All indoor units comprising with pre-filter, fan section with low noise fan multispeed motor, coil section with DX coil, outer cabinet, insulation, pipe connections, Wireless remote, Refnet joints indoor etc to make it functional.(d)The cost of Copper refrigerant piping (liquid & suction line) of various sizes with 19/13 mm thick nitrile rubber insulation, control cum transmission wiring to be properly laid in PVC conduit as per standards, drain piping insulated with thick nitrile rubber insulation and cabling work of suitable size from terrace panel to outdoor unit with necessary supports, cable/ pipe tray and clamps shall deemed to be included in quote rate.(e)02x Nos of earthing with 600x600x6mm GI plate and 24x 4mm GI Strip as shown in Plate no 3 of SSR Part I of 2009 shall be provided for each Outdoor unit.(f) Point wiring for each indoor unit shall deemed to be included in quoted rate.(g)Necessary LT control panels for outdoor units and indoor units and other components of VRF plant including necessary cabling/ wiring and MCCBs/ MCBs/ DBs deemed to be included in quoted rate.(h) Design of indoor/ outdoor units to be done as per the data sheet/ details of rooms to be air-conditioned provided.(i)All other items required to make VRF plant working satisfactorily shall deemed to be included in quote rate. |
| 112 | Supply and install manually rotating search light 250 watt LED with low voltage, high intensity weather & dust proof flood light in aluminum body complete with highly polished stainless steel mirror reflector, toughened front glass fitted in the cast aluminum front retaining ring, insulated handle and swiveling cradle with suitable base complete all as directed. |
| 113 | Supply, install, testing and commissioning manual Boom Barrier of length 6 meter of Stainless steel material with battery backup supply Including Electrical and civil works. Operating temperatures from -10°C to +55°C IP rating IP54Actuator weight41 kgControl unitLIBRA C MOPower supply230VMotor power supply24VAbsorbed power300WOpening or closing time:4 sec. / 2.5 sec (for toll naka) / 5 sec. |
| 114 | Supply, install, testing and commissioning of Tyre killer of length 6 meter, comprising hydraulic system to instantly deflate the tyres upon contact with specialized fail-safe puncture tool crafted from high-grade steel, working on 230 V power, 1 KW with remote operation complete including electrical and civil works. |