| 1 | Akalpause PH 2 |
| 2 | Thorough checking for finding out the faultin Pumping machinery for Low discharge as per direction of EIC. |
| 3 | Carrying charges for carrying one nos 12.5 HP pump motor set from PHE office (purto Bhavan) to Akalpause water supply scheme including loading & unloaidng complete as per direction of E.I.C. |
| 4 | Supply & delivery of thefollowing materials. |
| 5 | Nylone rope 1\" |
| 6 | Hiring charges of derrick set for withdrawing of pumping machinery as per direction of EIC. |
| 7 | Withdrawing of 12.5 HP oldpump-motor setby hired derick arrangement after disconnection of all electircal and pipe line connection completeas per direction of EIC. |
| 8 | Installtionof supplied 12.5 HP pumping machinery & above supplied items by hired derick arrangement and making all electrical and pipe line connection complete as per direction of EIC. |
| 9 | Akalpause PH 1 |
| 10 | Supply & delivery of thefollowing materials. |
| 11 | Supply and delivery ofSubmersible Pumping Machinery, directly coupled with suitable size water proof motor having following specifications.P U M PDISCHARGE ( 36 m^3/H)H E A D (58 mtr.)S H A F T.Stainless Steel.OUTLET SIZE. 80 mm. PUMP EFFICIENCY IN PERCENTAGE: Minimum 65.M O T O R(12.5 HP), S/D startingSubmersible type, 3ph.50Hz, A.C.- 400Volt +10%,wet type winding, RPM-2900.Pump set should be energy efficient and equivalent BEE standard energy star rating (3-5) as per IS – 8034:2002Make-KSB/PLUGA/TEXMO/ Approved Make). |
| 12 | Nylone rope 1\" |
| 13 | Hiring charges of derrick set for withdrawing of pumping machinery as per direction of EIC. |
| 14 | Withdrawing of 12.5 HP oldpump-motor setby hired derick arrangement after disconnection of all electircal and pipe line connection completeas per direction of EIC. |
| 15 | Installtionof supplied 12.5 HP pumping machinery & above supplied items by hired derick arrangement and making all electrical and pipe line connection complete as per direction of EIC. |
| 16 | Kashipur PH 2 |
| 17 | Thorough checking for finding out the fault in Electrical system as per direction of EIC. |
| 18 | Supply & delivery of thefollowing materials. |
| 19 | FASD Three Phase415 v ,Submersible Pump starter contactor rating 16A with short circuit protection (with auto switch).(relay range 13.2-20 amp).make- BCH/approved make |
| 20 | Labour charges for fitting fixing of above items and testing complete as per direciton of EIC. |
| 21 | Kashipur PH 3 |
| 22 | Thorough checking for finding out the fault in Pumping machinery as per direction of EIC. |
| 23 | Carrying charges for carrying one nos 10 HP pump motor set from PHE office (purto Bhavan) to Kashipur water supply scheme including loading & unloaidng complete as per direction of E.I.C. |
| 24 | Supply & delivery of thefollowing materials. |
| 25 | 3 mtr long 80mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG. |
| 26 | 1.1 KV grade 4 sq.mm x 3 Core water proof flat submersible cable for above motor. |
| 27 | Nylone rope 1\" |
| 28 | 5/8\" X 3\" Nut Bolt with double washer |
| 29 | 12\" x 12\" Rubber Sheet |
| 30 | Hiring charges of derrick set for withdrawing of pumping machinery as per direction of EIC. |
| 31 | Withdrawing of 10 HP oldpump-motor setby hired derick arrangement after disconnection of all electircal and pipe line connection completeas per direction of EIC. |
| 32 | Installtionof supplied 10 HP pumping machinery & above supplied items by hired derick arrangement and making all electrical and pipe line connection complete as per direction of EIC. |
| 33 | Bundebaj PH 2 |
| 34 | Supply & delivery of thefollowing Items. |
| 35 | 80mm dia. Non-rising spindle sluice valve (PN-1.0 rating) as per IS14846 for wash out and delivry line,Make: IVI/Jupiter/cair/approved make.MOC & TC needed for valve. |
| 36 | 80mm dia. N.R.V (PN-1.0 rating) as per IS5312, Make: IVI/Jupiter/Cair/approved make. MOC & TC needed for valve. |
| 37 | Ø 3 \"Flanged tail piece |
| 38 | Steel Plug, M. S. Nipple, Flange, Nuts, Bolts etc |
| 39 | Labour charges for dismantling of damage parts and fitting fixing of above items and testing complete as per direciton of EIC. |
| 40 | Satgachi PH 1 |
| 41 | Thorough checking for finding out the fault in Pumping machinery as per direction of EIC. |
| 42 | Supply & delivery of thefollowing Items. |
| 43 | 100 Amp. Re-wireable type TPN main switch (CONFORMS: IS/IEC600947-1&3). (Make: Approve make of P.H.E. Dte.) |
| 44 | Labour charges for fitting fixing of above items and testing complete as per direciton of EIC. |
| 45 | Supply & fitting fixing of 45 watt, LED Fixture set for Phillips Model no. BRP 031 LED with 40mm. dia. × 2.5mtr. long G.I pipe bracket fixing on wall of the Pump House with 3nos. M. S. clamp properly grouting including making power connection with supply and drawing 2.5sq.mm. copper flexible cable wire with controlling sub switch and continuous earthing from nearest junction board all complete as per direction of E.I.C. |
| 46 | Putsuri PH 1 |
| 47 | Supply & delivery of thefollowing Items. |
| 48 | Ø3 \" X 1.0 mtr CIDF Pipe |
| 49 | 5/8\" X 3\" Nut Bolt with double washer |
| 50 | 12\" x 12\" Rubber Sheet |
| 51 | Service charges for dismantling of damage item andfitting fixing of above itemsand testing complete as per direciton of EIC. |
| 52 | Antpara PH 3 |
| 53 | Thorough checking for finding out the fault in Pumping machinery as per direction of EIC. |
| 54 | Supply & delivery of thefollowing Items. |
| 55 | Supply and delivery of 100 Amps male female kit Kat fuse unit. |
| 56 | 100 Amp. Re-wireable type TPN main switch (CONFORMS: IS/IEC600947-1&3). (Make: Approve make of P.H.E. Dte.) |
| 57 | Labour charges for fitting fixing of above items and testing complete as per direciton of EIC. |
| 58 | Gramdihi PH 2 |
| 59 | Thorough checking for finding out the faultin Auto panel as per direction of EIC. |
| 60 | Supply & delivery of thefollowing material for repairing of auto panel. |
| 61 | Digital Ammeter.make-approved make |
| 62 | Digital Voltmeter.make-approved make |
| 63 | Service charges for dismantling of damage parts andfitting fixing of above item No and testing complete as per direciton of EIC. |
| 64 | Add GST @ 18% |
| 65 | Add Cess @ 1% |