}

Tender For Dr.Mvr Rtpp-Stage-I-Emmrt-Procurement Of Lt Make And Tc Make Power Contactors Only, kadapa-Andhra Pradesh

Andhra Pradesh Power Generation Corporation Limited has published Tender For Dr.Mvr Rtpp-Stage-I-Emmrt-Procurement Of Lt Make And Tc Make Power Contactors Only. Submission Date for this Tender is 19-06-2025. Contactors Tenders in kadapa Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48931854
Corrigendum : Tender For Dr.Mvr Rtpp-Stage-I-Emmrt-Procurement Of Lt Make And Tc Make Power Contactors Only
Tender
Indian
Andhra Pradesh
Kadapa
19-06-2025

Tender Details

Dr.Mvr Rtpp-Stage-I-Emmrt-Procurement Of Lt Make And Tc Make Power Contactors Only , Power Contactor: Type:Ml1.5:Coil Voltage:240V Ac:Current:25 A, 2No Plus 2Nc. Is/Iec 60947-4-1.,Power Contactor: Type:Ml4: Coil Voltage:110V Ac: Current:70A, 2No Plus 2Nc.Is/Iec 60947-4-1.,Power Contactor: Type:Ml4: Coil Voltage:415V Ac:Current:70 A, 2No Plus 2Nc.Is/Iec 60947-4-1.,Power Contactor:Type:Ml4:Coil Voltage:240V Ac, Current:70A,2No Plus 2Nc.Is/Iec 60947-4-1.,Power Contactor, Type:Ml10,Coil Voltage :240V Ac,Current:200A ,2No Plus 2Nc.Is/Iec 60947-4-1.,Relay,Overload:Current Range:3-5 A:Make: L And T:Additional Information:Mn2.Is 13947-4-1.,Relay,Overload:Current Range:9-15A:Make:L And T:Additional Information:Mn2. Is 13947-4-1.,Relay,Thermal Overload,14-25A,Mn2. Is 13947-4-1.,Relay,Thermal Overload,30-50A,Mn5.Is 13947-4-1.,Relay,Overload:Type:Thermal:Current Range:45-75 A:Model:Mn5.Is 13947-4-1.,Bimetal Overload Relays, 90-150A, Model:Mn12.Is 13947-4-1.,Power Contactor:Type:Ml1:Current 16A: Coil Voltage:415V.Is/Iec 60947-4-1.,Relay For Dol Starter :Current:6-10 A:Make:L And T:Model:Mk1, Is 13947-4-1.,Over Load Relay Range:4.5 - 7.5A, Type: Mn2,Make: L And T, Is/Iec Code:60947-4-1,Bimetal Overload Relays 20-33A Mn5, Make:L And T, Is/Iec Code:60947-4-1,Contactor,Ml1.5,25A,W/Coil 110Vac,Power Contactor: Type:Ml6: Coil Voltage:240V Ac: Current:110 A,2No Plus 2Nc. Is/Iec 60947-4-1,Coil For L And T Power Contactor Type: Ml6: Coil Voltage: 415 V Ac, Is/Iec 60947-4-1.Make: L And T,Air Break Power Contactor,Ac3,32A,Coil Voltage: 240V Ac : Aux Contacts: 1 No Plus 1 Nc: Cat Ref: Tc1-D32. Is Code: Is/Iec 60947-4-1:2009 And Bis Is 13947-4-1:1993(R2004).,Air Break Power Contactor,Ac3,18A,Coil Voltage: 240V Ac : Aux Contacts: 1 No Plus 1 Nc: Cat Ref: Tc1-D18. Is Code: Is/Iec 60947-4-1:2009 And Bis Is 13947-4-1:1993(R2004).,Spare Coil Suitable For Contactor Model: Tc1-D32: Coil Voltage 240V Ac. Is Code: Is/Iec 0947-4-1:2009 And Bis Is 13947-4-1:1993(R2004).,Spare Coil Suitable For Contactor Model: Tc1-D18: Coil Voltage 240V Ac. Is Code: Is/Iec 60947-4-1:2009 And Bis Is 13947-4-1:1993(R2004).,Spare Coil Suitable For Contactor Model: Tc1-D12: Coil Voltage 240V Ac. Is Code: Is/Iec 60947-4-1:2009 And Bis Is 13947-4-1:1993(R2004).,Over Load Relay, 2.5-4 A, Reference: Tr2-D09308, Make: Tc. Is Code: Is 3842:Part4:1996(Reaffirmed 2016) And Is/Iec 60255:Part8:1990.,Thermal Over Load Relay Contactor Mounting Current Setting Range: 12- 18.0A,Cat Ref: Lr1-D25321. Is Code: Is 3842:Part4:1996(Reaffirmed 2016) And Is/Iec 60255:Part8:1990.,Thermal Over Load Relay Contactor Mounting Current Setting Range: 18- 25.0A,Cat Ref: Lr1-D25322. Is Code: Is 3842:Part4:1996(Reaffirmed 2016) And Is/Iec 60255:Part8:1990.,Switch Disconnector Fuse Unit Without Fuses, 250 Amp, 3P,415V, Din Type,Make: C And S (Cssdf-250D3),,Switch Fuse Unit Without Fuses,400A,415V, Two Phase,Din Type, Model: Cssd400dm2,Power Contactor,3P,09A,110V Ac, With 1No Plus 1Nc. ,Type:Lc1d09f7-3.,Add On Block For Power And Aux.Contactor,Type:Ta1dn22,2No Plus 2Nc . Iec 60947-5-1: Low-Voltage Switchgear And Control-Gearpart 5 Control Circuit Devices And Switching Elementssection 1 Electromechanical Control Circuit Devices

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-06-2025 3rd due date extension 12-06-2025
2 12-06-2025 4th due date extension 19-06-2025
3 13-05-2025 1st due date extension 27-05-2025
4 28-05-2025 2nd due date extension 27-05-2025

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail