| 1 | NOTE (Applicable for all items) :-(i) The bidders/contractorsare advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) The bidders / contractors are advised to quote same rate for same items as mentioned in both parts of BOQ If quored rates are different for same items, lower quoted rate shall be considered for same items as mentioned in BOQ. For this account nothing extra shall be admissible by this Deptt.SCHEDULE \"A\" PART-I (B/R works) |
| 2 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and directed |
| 3 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead complete all as specified and directed |
| 4 | S&F Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer- in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre complete all as specified and directed (Note : cost of M.S. angle, C.C. blocks shall be paid separately) |
| 5 | M&L for Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in positionusing structural steel etc. as required : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar workscomplete all as specified and directed |
| 6 | M&L Painting New Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture complete all as specified and directed |
| 7 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed |
| 8 | Demolishing brick work built in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed |
| 9 | M&L for Brick work with Fly ash Bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed |
| 10 | M&L 15 mm thick cement plaster in cement morter 1:4on brick work finished even and smooth complete all as specified and directed |
| 11 | M & L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat weather coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 12 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 13 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead for coping and column complete all as specified and directed. |
| 14 | Providing and laying 20 mm nominal size graded stone aggregate 1:2:4 cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. excluding the cost of centering, shuttering and finishing complete all as specified and directed. |
| 15 | M&L for Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 16 | M&L for providing and laying in position cement concrete 1:4:8 stone aggregate 40 mm nominal size for mass concrete complete all as specified and directed. |
| 17 | M&L for Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level1:1.5:3 graded stone aggregate 20 mm nominal size complete all as per specified and directed |
| 18 | M&L for Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth Beam and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 graded stone aggregate 20 mm nominal size complete all as per specified and directed |
| 19 | M&L for Stone (polished) work Granite 16-18 mm thick of any colour and shade for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete all as specified and directed. |
| 20 | Supply and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement complete all as per specified and directed |
| 21 | M&L for Steel reinforcement of Thermo-Mechanically Treated bars of grade Fe-500D or more. for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete all as specified and directed. |
| 22 | M&L for Centering and shuttering including strutting, propping etc. and removal of form for Plinth Beam, Columns, Pillars, Piers, Abutments, Posts and Struts complete all as specified and directed. |
| 23 | M&L for Centering and shuttering including strutting, propping etc. and removal of form for Edges of RCC band and breaks in floors and walls Under 20 cm wide complete all as specified and directed. |
| 24 | M&L for Plain cement concrete 1:3:6 (using 20mm size stone aggregate) all complete as specified and directed. |
| 25 | M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors, including rubbing and cleaning etc. complete, over 20 mm thick bed of cement mortar 1:4 all complete as specified and directed. |
| 26 | Dismantling and stripping the unsound/weak concrete RCC structural members i,e Column, beam & slab etc. Including covering plaster by light chiseling & other manual methods until sound concrete surfaces comes up. Any trace of loose plaster, oil, grease, andfunguses if any or other materials that might affect adhesion are to be removed by wire brushing.Loose concrete/aggregate including all debris are to be desposed ofout side of MOD landThe entire exposed surface shall then be washed thoroughly with Clean water and then allowed to drycomplete as specified and directed. |
| 27 | Supply and Application Cementitious Grouting Admixture with the Cement slurry at a dosage 225gm per bag of cement and injecting with high pressure by a Pressure grouting Pump through non return PVC nozzles Prefix with rapid setting cementitious plugging mortar at a C/C Distance of 300mm to fill all possible pores and gaps left within the old concrete mass. When the flow of grout stops or shows refusal or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick-setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surfacecomplete as specified and directed.. Make-FOSROC /SIKA/STP/Choksy as approved by GE. |
| 28 | Material and labour for exposing the corroded reinforcement of any dia completely along its full circumference,. Cleaned to remove all loose scale and corrosion deposit, applying rust removing chemical followed by removing the rust by water paper and cleaning the area thoroughly by water and allow it to dry as per manufacture\"s instructionMake-FOSROC /SIKA/STP/Choksy as approved by GE. |
| 29 | Supply and Application of Epoxy Zinc Rich primer on the Prepared Reinforced surface after electro welding of it’s sectional area by brush , the primer should have a minimumspecific gravity 1.75. Minimum Wet film thickness /coat 100 microns & Dry film thickness / coat40 microns. Minimum Adhesive bond strength with steel is 1.5 N/mm2complete as specified and directed.Make-FOSROC /SIKA/STP/Choksy as approved by GE. |
| 30 | Supply and Application of New TMT bars of approved Brand of requisite diameter by electro welding of length 25 to 5d on both the sides with the existing bar to required size and shape complete all as specicifed and directed. |
| 31 | M&L formwork of smooth finish surfaces of column, beam, fascia,slab etc. with required bracing / support incl. fixing and striking out after pouring of concrete at all levels complete as specified and directed. |
| 32 | S&F for Epoxy Bonding agent to be applied on the concrete surface before the application of free flow non-shrink cementitious micro concrete mortar. The bonding agent should have minimum compressive strength 40 N/mm2 as per BS6319 Part 7. Minimum Flexural Strength 25 N/mm2 as per BS 6319 Part 3 and minimum bond strength as per ASTM C88111 N/mm2complete as specified and directed. Make-FOSROC /SIKA/STP/Choksy as approved by GE. |
| 33 | Supply and Application Free flow non-shrink cementitious Micro Concrete to the Affected Beam, Column etc. where major spelling has taken place even the core concrete affected. The Micro concrete should have a Minimum 1day Compressive strength of 10 N/mm2 and 7day Compressive strength of 35 N/mm2 And 28 days strength of 40 N/mm2complete as specified and directed.Make (Redwop, Sika, Fosroc etc) |
| 34 | Supply and Apply non shrink highly consistent light weight high grade polymer modified repair mortar for vertical and over head cementitious patch work mortar system where local spelling has taken place or shuttering is not possible. The mortar can be applied from a minimum 5mm to 15mm thickness in vertical and overhead applications. The mortar should have a minimum compressive strength 35 N/mm2 in 7 days and 45 N/mm2 in 45 days. Minimum flexural strength should be 6.5 N/mm2 in 28days. A modified styrene butadiene emulsion for use as a bonding aid and gauging liquid for cementitious system to be mixed with cement slurry before the application. The bonding agent should have minimum compressivestrength 24 N/mm2complete as specified and directed. Note :- 1.The rate is based on an Avg. thickness of 10mm. 3. This item shall be executed where shuttering is not possible or small patch repairs of structural elements 3. Make (polymer modified reinstatement mortar):- Renderoc S2 of FOSROC or equivalents solutions SIKA/STP/Choksy as approved by GE. |
| 35 | Supply and Application Two component high build polymer modified cementitious reinstatement mortar where local spelling has taken place or shuttering is not possible. The Mortar can be applied in thicknesses from 15mm to 40mm thickness in vertical and 25mm in overhead situations. The Mortar should have a minimum Compressive strength 7 N/mm2 in 1 Day and 20 N/mm2 in 28days. Minimum Flexural strength should be 4.5 N/mm2 in 28 days. Minimum Tensile strength should be 1.7 N/mm2 in 28days. A modified Styrene Butadiene Emulsion for use as a bonding aid and gauging liquid for cementitious system to be mixed with cement slurrybefore the application of two componentmicro concrete to be used@ 6 Ltr./bag of cement. The bonding agent should have minimum compressive strength 24 N/mm2. Note :- 1.The rate is based on an Avg. thickness of 25mm. 3. This item shall be executed where shuttering is not possible or small patch repairs of structural elements 3. Make (polymer modified reinstatement mortar):- Renderoc S2 of FOSROC or equivalents solutions SIKA/STP/Choksy as approved by GE. |
| 36 | Material , labour forapplying of high efficiency polymeric resin base filmforming curing agent/compoundover concretesurfaceandmaximum coverage area 5.00 Sqm per litre as per manufacturers instruction complete all as specifiedandas directed.Make:- Concure LP90 of FOSROC or equivalents solutions SIKA/STP/ Maruti / Choksey chemicals. |
| 37 | M&L for6 mm cement plaster of mix : 1:3 finished even andsmooth (without using extra lime or cement complete all as specified and directed. |
| 38 | M & L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat weather coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) complete all as specified and directed. |
| 39 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis,M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of structure (length/breadth of building X height of building) of the scaffolded area shall be measured for payment purpose.(2) The payment shall be made once time only for execution of all times each face of building/structure.(3) After completion of work all scaffolding materials shall be removed from building / structure by the contractor and the same shall be removed from building/ structure by the contractor and the same shall be the property of the contractor and accordingly rate shall be quoted. |
| 40 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 41 | M&L for steel work welded in built up sections/framed work including cutting,hoisting,fixing in position using structural steel etc as required in gratings,frame,guard bar,ladder,railings,brackets,gates and similar works complete as per direction. |
| 42 | M&L for painting new steel work with multi surface paint to give an even shade.Two or more coat applied @ 0.890 lit/10 Sqm over an under coat of primer applied @ 0.80 lit/10 Sqm of approved brand and as per manufacturers instruction complete all as directed. |
| 43 | NOTE (Applicable for all items) :-(i) The bidders/contractorsare advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.(ii) The bidders / contractors are advised to quote same rate for same items as mentioned in both parts of BOQ If quored rates are different for same items, lower quoted rate shall be considered for same items as mentioned in BOQ. For this account nothing extra shall be admissible by this Deptt.SCHEDULE \"A\" PART-II (E/M works) |
| 44 | Dismantling 150 mm C.I.water pipe with fittings and clamps including stacking the material within 50 metres lead complete all as specified and as directed. |
| 45 | Dismantling 100 mm C.I.water pipe with fittings and clamps including stacking the material within 50 metres lead complete all as specified and as directed. |
| 46 | Dismantling 80 mm C.I.water pipe with fittings and clamps including stacking the material within 50 metres lead complete all as specified and as directed. |
| 47 | Supply and fixing 150 mm dia Ductile Iron Double Flanged(Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329including EPDM gaskets of same size, complete all as specified and as directed. |
| 48 | Supply and fixing 100 mm dia Ductile Iron Double Flanged(Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 including EPDM gaskets of same size, complete all as specified and as directed. |
| 49 | Supply and fixing 80 mm dia Ductile Iron Double Flanged(Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 including EPDM gaskets of same size, complete all as specified and as directed. |
| 50 | Material and labour for DI bends,Tees, Collar, Tail piece etc(any type & shape and angle) tapers of any type (straight, bend, increasing decreasing or double socket etc ) Tee pieces single branch,Y junction double branch, cross(all sockets or socket& spigot) collars caps and plugs suitable for DI pipe upto 150 mm dia complete all as specified and as directed. |
| 51 | Supply and fix in repair Sluice Valves, flanged of class 1.6 PN150 mm (6”) dia complete with bolts, nuts, rubber insertions etccomplete all as specified and as directed. |
| 52 | Supply and fix in repair Sluice Valves, flanged of class 1.6 PN100 mm (4”) dia complete with bolts, nuts, rubber insertions etccomplete all as specified and as directed. |
| 53 | Supply and fix in repair Sluice Valves, flanged of class 1.6 PN80 mm (3”) dia complete with bolts, nuts, rubber insertions etccomplete all as specified and as directed. |
| 54 | Supply and fix in repair butterfly Valve, conforming to IS 13095,150 mm (6”) dia complete all as specified and as directed. |
| 55 | Supply and fix in repair butterfly Valve, conforming to IS 13095,100 mm (4”) dia complete all as specified and as directed. |
| 56 | Material and labour in replacement for level indicator in over head Tank made up of scaling arrangement in GI sheet of 1800x150x3 mm with string and ball arrangement complete all as specified and as directed. |
| 57 | S&F in repair Clamps and M.S. stays including bolts and nuts for 80-150 mm pipe fixing complete all as specified and as directed. |
| 58 | Supply, laying, connecting, testing and comissioning cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm2 coreincluding connection cable glands, aluminium lugs etc complete all as specified and as directed. |
| 59 | Excavation in trenches, foundations n. exc 1.5 m wide and n.exc 1.5 m in depth for laying of cables,poles and getting out in soft/ loose soil complete all as specified and as directed. |
| 60 | Returning,filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cmcomplete all as specified and as directed . |
| 61 | Removing excavated soil to a distance not exceeding 50 metre anddepositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and as directed. |
| 62 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to desired thickness complete all as specified and as directed. |
| 63 | M&L for laying of fly ashbricks locally availablefor cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cableall as directed. |
| 64 | Supplying and embedding, in replacement 32 mm dia G.I. pipe (medium class) in pole collar/ foundation (during casting)/PCC /Hard standing/drain line cutting for cable entry including bending the pipe to the required shape complete with making good distrurbed surfaces of walls, floors etcas requiredcomplete all as specified and as directed. |
| 65 | S&F in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 66 | Supply & Fixing in repairs cable junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 155x210x92 mm and suitable for LT under ground cable any size/capacity including bracing clamp,bolts,nuts & washers complete all as specified and as directed. |
| 67 | M&L for in replacement, PVC copper cable of size 2x1.5sq mm for junction box to street light fitting connection complete all as specified and as directed. |
| 68 | M&L for in replacement, 20mm dia Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed. |
| 69 | M&L for in replacement, flexible hose pipe of size 20mm protection of copper wire complete all as specified and as directed. |
| 70 | Taking down Sub main/ circuit wiring of any type and size including conduit/capping casing/batten wiring for necessary repair/replacementcomplete all as specified and as directed. |
| 71 | M&L for circuit/ submain wiringusing two runs of FRLSH grade PVC insulated unsheathed stranded copper conductor cable of size2.5 sqmm and one run of 2.5 sqmm FRLSH grade PVC insulated unsheathed stranded single corecopper earth wire to be drawnin and including at least 20 mm size steel conduit(medium grade)in surface/ recessed with all fittings as requireddolly for over head tank complete all as specified and directed. |
| 72 | Materials and labour for in repair earthing with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4 mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge. |
| 73 | Material and labour in replacement for Galvanised iron strip 25 x 4 mm from ground to overhead tank complete all as specified and directed. |
| 74 | S&F in replacement LED type obstruction light at top of the water reserviour of cap upto 50,000 GL Protection : Weather proof IP 56Material of construction: Cast aluminum (L.M 6) Transparent part : toughened clear, transpare, borosilicate hard glass. Gasket : Endless neoprent. Total weight : Less than 5Kg Cable entry : ET 19 mm (at base), Colour : Redviewing angle:All direction.Total integrated Candela:2000+ candelasIntensity of each LED : 250 - 300 mcd.Total power consumption : 15W at 230VMax. Forward current : 150 mAInsulation resistance : 100M ohm at 500VEarthing : Terminal provided.Input voltage Fluctuation:Can with stand +25% 12/24/36/48V DC version available with all necessary electric connection complete all as directed, (Fitting shoule be yellow painted die-cast aluminium alloy housing with 5 parallel circuits with accessories.) |
| 75 | M&L forin replacementtest point terminal blocks made out of gun metal (or) phosphorus bronze size 75x75x25mm drilled and screwed with and including 3 Nos 8mm dia 25mm long hexagonal head screws complete all as specified and directed. |
| 76 | M&L forin replacement Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 77 | S&F forin replacement Air termination single pointed aluminiumrod 12mm dia 300mm long fixed on PCC blocks of size 300x300x300mm by means of GI pipe of 40mm dia light grade complete. Note: GI pipe for mounting of air termination rod shall be considered seperately |
| 78 | Materials and labour for in repair galvanized iron Tubing light grade of size 40 mm dia for mounting of air termination rod etc complete all as specified and directed |