| 1 | Cleaning/ removal of blockage of floor trap/ nahani traps of 75 mm/100 mm bore in kitchen/ bathroom/ toilets etc., including removing PVC/ stainless steel grating and refixing the same with white cement and pigment to match the surface after making the floor/ nahani trap fully functional complete all as specified and as directed. |
| 2 | Cleaning/ removal of blockage of gully trap any size and any depth including removing RCC covers and refixing the same after making the gully trap fully functional complete all as specified and as directed. |
| 3 | Cleaning/ removal of blockage of Indian type WC and ‘P’/’S’ trap and making fully functional complete all as specified and as directed. |
| 4 | Cleaning/ removal of blockage of European type WC ‘P’/’S’ trap and making fully functional complete all as specified and as directed. |
| 5 | Cleaning/ removal of blockage of European type WC, ‘P’/’S’ trap including removing carefully of EWC and cleaning the trap completely and making fully functional and refixing the WC in same position including necessary bolts and making good to disturbed surfaces with white cement and pigment to match the existing surface complete all as specified and as directed. |
| 6 | Cleaning of sewage pipe lines of size upto 100mm dia bore at any depth and removing the blockage by rodding/ by using bamboo split or by mechanical means, between the manholes, Nahani traps to gully traps, gully traps to manholes including vertical stack pipes (where ordered), taking out all debries, sludge or any solid/foreign materials from sewage line and flushing with water and testing after cleaning for leakages/clogging, etc., complete including removing and disinfected the sludge within 50m distance including necessary excavation of pits and returning, filing in sprinkling of bleaching powder @ 0.50 kg/Sqm and dressing of surplus soil, ground to slope if required complete all as specified and as directed. |
| 7 | Cleaning of sewage pipe lines of size upto 150mm dia bore at any depth and removing the blockage by rodding/ by using bamboo split or by mechanical means, between the manholes, Nahani traps to gully traps, gully traps to manholes including vertical stack pipes (where ordered), taking out all debries, sludge or any solid/foreign materials from sewage line and flushing with water and testing after cleaning for leakages/clogging, etc. completeincluding removing and disinfacted the sludge within 50m distance including necessary excavation of pits and returning, filing in sprinkling of bleaching powder @ 0.50 kg/Sqm and dressing of surplus soil, ground to slope if required complete all as specified and as directed. |
| 8 | Cleaning of sewage pipe lines of size upto 200mm dia bore at any depth and removing the blockage by rodding/ by using bamboo split or by mechanical means, between the manholes, Nahani traps to gully traps, gully traps to manholes including vertical stack pipes (where ordered), taking out all debries, sludge or any solid/foreign materials from sewage line and flushing with water and testing after cleaning for leakages/clogging, etc. completeincluding removing and disinfacted the sludge within 50 metres distance including necessary excavation of pits and returning, filing in sprinkling of bleaching powder @ 0.50 kg/Sqm and dressing of surplus soil, ground to slope if requiredcomplete all as specified and as directed. |
| 9 | Cleaning of sewage pipe lines of size upto 300mm dia bore at any depth and removing the blockage by rodding/ by using bamboo split or by mechanical means, between the manholes, Nahani traps to gully traps, gully traps to manholes including vertical stack pipes (where ordered), taking out all debries, sludge or any solid/foreign materials from sewage line and flushing with water and testing after cleaning for leakages/clogging, etc., complete including removing the debries to outside MOD land complete all as specified and as directed. |
| 10 | Cleaning/ removal of blockage of upto 100mm bore pipes of any description fixed to walls including removing the access plate of bend door and refixing the same after making the pipes fully functional, including all necessary arrangement upto 7th floor complete all as specified and as directed. |
| 11 | Cleaning of blockage in sewage pipe lines between manhole to manhole of any bore of pipe and in any depth distance not exc 40m and removing the blockages using by vehicle mounted jet pressure or vaccum system cleaning of pipes and taking out all debries, sludge or any solid/ foreign materials from sewage line and flushing with water and testing after cleaning for blockages/ clogging etc., including removing and disinfacted the sludge within 50m distance including necessary excavation of pits and returning, filing in sprinkling of bleaching powder @ 0.50 kg/Sqm and dressing of surplus soil, ground to slope if requiredcomplete all as specified and as directed. |
| 12 | M&L for desilting and cleaning of manholes (as existing shape and size) of depth not exc 1m by pumping out the sewage water complete removing the sluge and other materials from manholes by mechanical means, roding or any other suitable means removing the accumulated night soil, sludge and other materials obtained from sewage lines and disinfacted the sludge within 50m distance including necessary excavation of pits and returning, filing in sprinkling of bleaching powder @ 0.50 kg/Sqm and dressing of surplus soil, ground to slope if required and well flushing the manholes with water complete all as specified and as directed by Engr-in-charge. |
| 13 | M&L for desilting and cleaning of manholes (as existing shape and size) of depth exc 1m but not exc 2m by pumping out the sewage water complete removing the sluge and other materials from manholes by mechanical means, roding or any other suitable means removing the accumulated night soil, sludge and other materials obtained from sewage lines and disinfacted the sludge within 50m distance including necessary excavation of pits and returning, filing in sprinkling of bleaching powder @ 0.50 kg/Sqm and dressing of surplus soil, ground to slope if required and well flushing the manholes with water complete all as specified and as directed. |
| 14 | M&L for desilting and cleaning of manholes (as existing shape and size) of depth exc 2m but not exc 3m by pumping out the sewage water complete removing the sluge and other materials from manholes by mechanical means, roding or any other suitable means removing the accumulated night soil, sludge and other materials obtained from sewage lines and disinfacted the sludge within 50m distance including necessary excavation of pits and returning, filing in sprinkling of bleaching powder @ 0.50 kg/Sqm and dressing of surplus soil, ground to slope if required and well flushing the manholes with water complete all as specified and as directed. |
| 15 | Demolition of Reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-charge.Note: All debris and rubbish shall be removed from MoD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state and local regulations. |
| 16 | M&L for providing precast cement concrete type B1 1:2:4 (Using 20mm graded stone aggregate) as in landings, chamber/ cover slabs for man holes etc and similar articles with plain faces and set in cement mortar 1:4 where required complete all as specified and as directed. |
| 17 | S&F TMT bars 10mm dia and over, cut to length, bent to shape required including cranking required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confirming to Fe-410 Gde E-250for stretched wire complete all as specified and as directed. |
| 18 | S&F in repairs mild steel plain black sheet, 1.6mm thick as in cladding, cut to required size, bending or turning up, mitred angles, etc., placed in position and welded complete all as specified and as directed. |
| 19 | Dismantling iron work of any description complete all as specified and as directed. |
| 20 | S&F for cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles (articles not exc 5 kg each) complete all as specified and as directed. |
| 21 | All as per item No.20.00 here-in-before but articles exc 5 kg each. |
| 22 | M&L for preparing of old chequered tiled and paver block surfaces /existing footpath by removing all the caked mud with wire brushes and cleaning surfaces with necessary acid and description not otherwise described and applying one coat of weather proof tile guard apex paint or equivalent of any colour complete all as specified and as directed. |
| 23 | S&F for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 24 | M&L for preparation of new or previously untreated steel and iron surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel (ordinary tint) paint over a coat of red oxide priming paint complete all as specified and as directed by Engr-in-charge. |
| 25 | Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for foundation manholes etc., and getting out in soft /loose soil complete all as specified and as directed. |
| 26 | Excavation in trenches not exc 1.5m wide and exc 1.5m but not exc 3m depth for foundation manholes etc., and getting out in hard/dense soil complete all as specified and as directed. |
| 27 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cms in solft/loose soil complete all as specified and as directed. |
| 28 | Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point soil complete all as specified and as directed . |
| 29 | M&L for 150mm bore double wall corrugated HDPE pipe (DWC HDPE) of stiffness class designation SN 8 (confirming to IS 16098 Part -2:2013Spigot and socket ended pipe) at site confirming to relevant IS and CPHEEO specification jointing with rubber gasket, along with all necessary fittings for jointing the pipe and including demolition and breaking up drain pipes and concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type complete all as specified and as directed.Notes for BOQ Item No 29.00 to 33.00: All debris and rubbish shall be removed from MoD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state and local regulations. |
| 30 | M&L for 200mm bore double wall corrugated HDPE pipe (DWC HDPE) of stiffness class designation SN 8 (confirming to IS 16098 Part -2:2013Spigot and socket ended pipe) at site confirming to relevant IS and CPHEEO specification jointing with rubber gasket, along with all necessary fittings for jointing the pipe and including demolition and breaking up drain pipes and concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type complete all as specified and as directed. |
| 31 | M&L for 150mm bore salt-glazed stoneware drain pipes laid in trenches and jointed and including demolition and breaking up drain pipes and concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type complete all as specified and as directed. |
| 32 | M&L for 200mm bore salt-glazed stoneware drain pipes laid in trenches and jointed and including demolition and breaking up drain pipes and concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type complete all as specified and as directed. |
| 33 | M&L for reinforced concrete pipes 300mm bore, class NP-3, laidand jointed complete with collers and including demolition and breaking up drain pipes and concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type complete all as specified and as directed. |
| 34 | S&F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 35 | Demolition of brickwork or stone/boulder/PCC block masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 36 | M&L for precast cement concrete block masonary with solid blocks, type C-1 1:3:6 (Using 20mm graded stone aggregate), exc 10 cm in width and setting in cement mortar in CM 1:6 complete all as specified and as directed. |
| 37 | M&L for providing precast cement concrete solid building blocks or slabs, type C-1, 1:3:6 (Using 20mm graded stone aggregate), 10cm thick (with plain or interlocking joints) setting in cement mortar 1:4 complete all as specified and as directed. |
| 38 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-charge.Note: All debris and rubbish shall be removed from MoD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state and local regulations. |
| 39 | M&L for 25mm thick PCC (1:2:4), type B0 using 12.5mm graded stone aggregate as in flooring, rough finish surfaces for receving top layer complete all as specified and as directed. |
| 40 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc., set and jointed in neat cement slurry over and including 15mm thick screed bed of cement mortar 1:6 and pointed with white or coloured cement to match complete all as specified and as directed. |
| 41 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm on vertical surfaces for skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in cement mortar 1:4 for backing of tiles complete all as specified and as directed. |
| 42 | M&L for coloured non skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm, in floors etc., set and jointed in neat cement slurry over and including 15mm thick screed bed of cement mortar 1:6 and pointed with white or coloured cement to match complete all as specified and as directed. |
| 43 | M&L for coloured glazed ceramic design tiles 350x250x7mm/ 450x300x7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 44 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including racking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed. |
| 45 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement complete all as specified and as directed. |
| 46 | M&L for neeru finish to plastering complete all as specified and as directed. |
| 47 | M&L for preparing new plastered surfaces and applying three coats of white wash on surfaces of walls complete all as specified and as directed. |
| 48 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations. |
| 49 | M&L for PCC 1:2:4, type B-0 (Using 12.5mm graded stone aggregate) as in coping and benching and the like including weathering slightly rounded or chamfered angle and throating complete all as specified and as directed. |
| 50 | M&L for 75mm thick PCC 1:2:4 type B1 (Using 20mm gradedstone aggregate) as in floor including finishing the surface even and fair complete all as specified and as directed. |
| 51 | M&L for 40mm thick cement concrete type B-0, 1:2:4 (Using 12.5mm graded stone aggregate) complete all as specified and as directed. |
| 52 | M&L for 75mm thick cement concrete type C-2, 1:3:6 (Using 40mm graded stone aggregate) as in flooring, plinth protection, bases of water tanks etc., complete all as specified and as directed. |
| 53 | M&L for PCC 1:3:6 type C2 (Using 20mm graded stone aggregate) cement concrete in surface channels and drains complete all as specified and as directed. |
| 54 | M&L for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified and as directed by Engr-in-charge. |
| 55 | All as per item No.54.00 here-in-before but add or deduct for each 25mm girth or part thereof over or under 30cm complete all as specified and as directed. |
| 56 | S&F in repair ball valves 20mm dia, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 20 mm-210gms/ 25mm-455gms/ 40mm - 690 gms) complete all as specified and as directed. |
| 57 | S&F in repair ball valves 25mm dia, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 20 mm-210gms/ 25mm-455gms/ 40mm - 690 gms) complete all as specified and as directed. |
| 58 | S&F in repairs 20mm ball valves, Brass, high pressure, with polythane float and flynut, screwed for iron pipe or brass ferrule complete all as specified and as directed. |
| 59 | S&F GI tubes 15mm bore, medium grade, with all fitting and fixed complete to walls and ceilings or laid in floors including taking up or down old steel tubing complete all as specified and as directed. |
| 60 | S&F GI tubes 20mm bore, medium grade, with all fitting and fixed complete to walls and ceilings or laid in floors including taking up or down old steel tubing complete all as specified and as directed. |
| 61 | S&F GI tubes 25mm bore, medium grade , with all fitting and fixed complete to walls and ceilings or laid in floors including taking up or down old steel tubing complete all as specified and as directed. |
| 62 | Supplying and laying of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors outer diameter of pipes in 16mm including taking up or down old pipe complete all as specified and as directed. |
| 63 | S&F UPVC 15mm dia pipe of pressure rating 10kg f/cm² fixed complete to walls, ceiling or in floor etc., including brass fittings and fittings., any type of pipe including taking up or down old pipe complete all as specified and as directed. |
| 64 | S&F UPVC 20mm dia pipe of pressure rating 10kg f/cm² fixed complete to walls, ceiling or in floor etc., including brass fittings and fittings., any type of pipe including taking up or down old pipe complete all as specified and as directed. |
| 65 | S&F UPVC 25mm dia pipe of pressure rating 10kg f/cm² fixed complete to walls, ceiling or in floor etc., including brass fittings and fittings., any type of pipe including taking up or down old pipe complete all as specified and as directed. |
| 66 | S&Fin repairs 100mm dia stainless steel gratings without hole /with hole of min weight 50 gms and fixing it with white cement complete all as specified and as directed. |
| 67 | Taking down rain water pipes including all fittings any size and pattern upto 7thfloors complete all as specified and as directed. |
| 68 | M&L for 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including all fittings complete all as specified and as directed. |
| 69 | M&L for 110mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls including all fittings complete all as specified and as directed. |
| 70 | M&L for 150 mm PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls as rainwater pipe including all fittings complete all as specified and as directed. |
| 71 | S&F 110mm dia, vent cowl complete all as specified and as directed. |
| 72 | S&F PVC (SWR) \"P\" or \"S\" trap 110mm bore all including demolition of floors and filling after fitting complete all as specified and as directed. |
| 73 | S&Fin repairs rimless single piece-WC with UF slim seat cover, hinges, fixing accessories and accessories set, cistern fittings, Size: 380x670x765 mm, S Trap - 300mmcomplete all as specified and as directed.Make: Jaguar FSS-WHT-29853S300UFSM or techno-commercially equivalent in HINDWARE/ PARRYWARE/ CERA/PRAYAG |
| 74 | S&F in repairs vitreous china wash basin, size 550x400mm white including brackets, and waste coupling and pipe of 32mm dia, brass, chromium plated for glazed ware sinks, basins white or tinted, etc., with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other and fixed complete all as specified and as directed. |
| 75 | S&F in repairs plastic water closet seat, white or tinted, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 76 | S&F in repairs PVC valveless, syphonic action type, flushing cistern of 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and as directed. |
| 77 | M&L for cleaning and removing all scale and dirt, etc., from PVC and RCC water tank of capacity exc 250 ltrs but not exc 500 ltrs including removing existing writing letters and rewriting letters as cleaned on Month and date by using stencil cutting with synthetic enamel paint (height of each letter not less than 5 Cm) as affected including wash the tank with water andbleaching powder after removing scale and dirt etc., complete all as specified and as directed. |
| 78 | M&L for cleaning and removing all scale and dirt, etc from PVC and RCC water tank of capacity exc 500 ltrs but not exc 1000 ltrs including removing existing writing letters and rewriting letters as cleaned on Month and date by using stencil cutting with synthetic enamel paint (height of each letter not less than 5 Cm) as affected including wash the tank with water andbleaching powder after removing scale and dirt etc., complete all as specified and as directed. |
| 79 | S&F in repair self threaded water tank lid /cover with frame \"cooltex type\" fixed to existing tank 500/1000 litrs capacity with joint nut and bolt complete all as specified and as directed. |
| 80 | S&F in repair vitreous china wash down water closet (Pedestal pattern, EWC), white including fixing bolts, Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 81 | S&F in repair vitreous china squatting pan, ‘Orissa’ pattern, size 630x450mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, with trap set and to flushing pipe, antisyphonage pipe, etc., including making good to floor (concrete) complete all as specified and as directed. |
| 82 | Removing old dumped junk/ building materials/ debris/ tree roots, trunk and branches of any size etc., to a distance of 30Km or beyond, out of premises of metropolitan area, including loading, unloading by manually or by mechanical means (JCB) and to be transported through tractor-trolly or tipper and stacking at the destination complete all as specified and as directed. |